Loading...
HomeMy WebLinkAbout8103_Rutherford_Central_MSWLF_CDLF_July2021LFG_FID1588419_20210709NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Rutherford County Landfill South - MSWLF (CLOSED) Permit Number: 8102-MSWLF Sampling Dale _9 --I - a'` _ NC Landfill Rule (.0500 or.1600): Sample Collector Name & Position: Jeff Nicholson - Field Services Manager 0.500 //—�1 Gas Meter Type &Serial Ntiit�k�er: GEM 5000 S/N 51 0S I d- Gas Meter Calibration Date: Field Calibration Date & Time: Field Calibration Gas Type (15115 o 5/50): Field Calibration Gas Canister Expiration Date: 2 3 Gas Meter Pump Rate: N/M Ambient Air Temperature: r)Z Barometric Pressure (in. or mmHg): O•OS Weather Conditions: Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume) x 20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped (sec) Initial 9/6LEL Stabilized % LEL % CH4 (volume) % 02 (volume) % CO2 (volume) % H2S* (volume) f NOTES Building #1 1 1; 0a. 60 Q O ®•d C90 0,40 Building#2 O 0,0 d� Building #3 1 : (� 60 Q 0.0 do ,I 0.0 (9 OA.as LFG - 11 i , �� d 6 LFG - 10 % to 0^^ O = a /�:. ,4 3,4 LFG -8VENT "� ,t(S v V a-q Ic-%A LFG -7VENT 1 1 ,5° by © 9 0. y add 0.°7 c7q•3i LFG-6 9,64 60 0 d 0.0 ItA 1.6 LFG - 5 1 `l S � � O 'D . 0 1 A LFG - 4 VENT �',Ot^ p60 U`) 9,0 lI . �j . a `� 0 a' a , atj LFG - 3 q L9 i1pl i �`� � �i 0 aa• LFG - 2 tt �- �� UV 00 � I • o NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >I% by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certific iian including the possibility of a fine and imprisonment. Field Services Manager SIGNAT TITLE Revised —February 4, 2020 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1 As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Rutherford County Landfill South - MSWLF (CLOSED) Permit Number: 8102-MSWLF Sampling Date: '1 " -a ( NC Landfill Rule (.0500 or.1600): 0.500 Sample Collector Name & Position: Jeff Nicholson - Field Services Manager Gas Meter Type & Serial Number: GEM 5000 S/N C, Sb 85 la Field Calibration Date & Time: T-) _ - 4P Gas Meter Calibration Date: 0" 7 ' ?o Field Calibration Gas Type (15115 or C50) Field Calibration Gas Canister Expiration Date: 8 - 31. �Y Gas Meter Pump Rate: N/M Ambient Air Temperature:_Barometric Pressure (in. or mm Hg): 0-S• 29' Weather Conditions: Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume) x 20 = % LEL. *ffydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Wei ID Sample Purge ge Time of y Time Pumped (see) Initial /o LEL Stabilized /o LEL % CH4 (volume) % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES LFG - 1 00% ( �0 0pp ® ©.0 1514 '1. `1 V as . -. LFG - 13 1 �. el bo V 6 Q. , Q ao.a O � � ah . IS LFG -12 I ,Sa 0 a' tW.1 01 - d4,, LFG - 14 I 167 60 4 0 0.0 20 "1 01- 0 0 9A, LFG -15 a.; � ��qo ��•1 {A �p,) D LFG - 16 ��� rr61) b0 ©: ku. i �. \ 0 LFG -09 q� 1'�!, l� 0 010 %0.-1 010 (0 9A.1-i NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. M, JCL Field Services Manager SIGI+I U TITLE Revised —February 4, 2020 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: Phis form and any information attached to it are "Public Records" as defined in NC General Statute 132-1 As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Rutherford County Landfill Central - C&D Permit Number: 8103-CDLF l Sampling Bate: -� 'a{ NC' Landfill Rule (.0500 or.1600): 1600 Sample Collector Name & Position: Jeff Nicholson - Field Services Manager Gas Meter Type & Serial Numbcr. GEM 5000 S/N G-S6 �5 �� Gas Meter Calibration Date: r%^ ��' ci3O Field Calibration Date & Time: -11") -a I /' (� Field Calibration Gas Type (15115 o l50 . Field Calibration Gas Canister Expiration Date: � - 31 - ay Gas Meter Pump Rate: _. N/M Ambient Air Temperature: I b Barometric Pressure (in. orram. Hg):Dq A Weather Conditions: 6 �4e-C - Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume) x 20 = % LEL. *Hydrogetr Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped (sec) Initial e �o LEL Stabilized /a LEL % CH4 (volume) ale 02 (volume) % CO2 (volume) % H2S* (volume) NOTES Background Q M Lo 0 0 0,0 90,q 6 t O JI r(q Animal Shelter Wj q AP 1 0 B 0,0 aG t 4 0,0 cam. f I Scale House 11105 bo 0 tJ 0,0 90,� O.•C VI4111 Storage Room ( 1 ( , 0o� &0 0 0 0,0 3e•a 0 r D 0 9Q. fI Maintenance Shop I I I eA VO 0 O U. . o � (1, (0,0 O �4� .1I Transfer Station #1 1 1 I •, ao Vo O 0 0, o 00'rN 0, 0 go (A r• .11 Transfer station 02 r \ 1 �1 i% ` P 60 V 0 'V 0 0,0 Oro A V — iii 0,0 � j'I �1 a l LFG - 1 ( 11'•i$ bo �Q 0 (0,0 5,1 a,q 0q.05— LFG - 2 ( (�`ly` LO 0 0.0 rb �%A. aS LFG - 3 h S5 U0 0 b 0,0 LFG-4 p,13 t7o O o 0.0 LFG - 5 ( �',A U1b �O 0 0.0 jei. 95 NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >_5% by volume (at facility boundary) Hydrogen Sulfide: >1% by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certif c Lion including the possibility of a fine and imprisonment. Field Services Manager SIGN111W TITLE Revised - February 4, 2020 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1 As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Rutherford County Landfill Central - C&D Pcrmit Number: ` 8103-CDLF Sampling Date: "� ' � ( o . NC Landfill Rule (.0500 or. 1600). 1600 ` Sample Collector Name & Position: Jeff Nicholson - Field Services Manager Gas Meter Type & Serial Number: GEM 5000 S/N Lj D t'S (a Gas Meter Calibration Date: �3 Field Calibration Date & Time _�. "� ` �, f0 ° �0 Field Calibration Gas Type (15115 or 5/5 Gas Meter Pump Rate: N/M Field Calibration Gas Canister Expiration Date: I - 3 (- a Ambient Air Temperature: U Barometric Pressure (in. or mm Hg): �� Weather Conditions: 6tJe---C"' f Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume) x 20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized % LEL % CH4 volume (volume) % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES 6F-6 9— LFG 10 ( 1 . 50 61) 0 © 0. (�v'1 . LFG-9 1rr3 ,00 bV C1 �.t� ,qS �. LFG - 11 ` 13 ' (V V Q V•. (7 pp// ll7 t `0I,.b "l - �� a5 NOTE: Ifne, del. attach additional dataforms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1% by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or ce Tlion including the possibility of a fine and imprisonment. 15U Field Services Manager SIG All TITLE Revised — February 4, 2020 CERTIFICATION OF CALIBRATION Date Of Calibration: 23-Jul-2020 No. 66916 Certificate Number: G506134_9/39668 Issued by: QED Environmental Systems Inc. CWtomen: EASTERN SOLUTIONS ELC 109D9 R022ELLES FERRY RD CHARLOTTE, IBC 48214 USA MWIndne c.nw Certified Gas % Irmtrument Readl % Llkertain % 5.0 4.9 0.42 15.0 14.9 0.66 50.0 .49.4 1.03 Carbon Dioxide CO2 - -- - -UF1 ttat 4.9 4.7 0.43 15.0 14J 0.71 50.0 49.9 1.19 Gas cylinders are traceable and details can be provided if requested. CH4, CO2 readings recorded at: 32.8 °C(91.1 "F Barometric Pressure: 0985" Hgj29.09 "Fig 02 readings recorded at: 22.2 "C/71.9 "F Method of Test -The analyzer is calibrated in a temperature controlled chamber using a series of reference gases, in compliance with procedure iSPIT The reported expanded uncertainty is based on o standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 9596_ The uncertainty evaluation has been carried out in accordance with NISI requirements- Thet Cau6ratlon results puWtshed In this certlrcate wue obtained using equlpnterrt capable of producing results that arc traceable through NISI to tite Internatlonal System of units I511. Certlfkation only applles to results shown. This cerb6cate may not be reproduced ether than In full, adept with the prior written approva3 of the Issuing laboratory. c.li6r0mn rdea - 107 KPC Zm=n - wn Pogo 1 ar: I L?015[NAMT-E l www.gedenv,com (800) 624-2026 info@gedenv.com QED Environmental Systems Inc. 2355 Bishop Circle West, Dexter, MI 48130 pPP CERTIFICATION OF CALIBRATION No. 66916 Date Of Calibration,. 23-Jut-2020 Issued by: QED Environmental Systems Inc. Non Accredited results: Certificate `dumber: 6506134_9139668 Pressure Transducers linches of water column Transducer CertHied (tow) Reading (low) certified (141gh) heading (FFlgh) Accuracy static ❑" a" 40+' 4.001' 1 2.0" Differential 0" 0" 4" 1 4.00ki I 0.7" As received gas check readings are only recorded if the instrument is received in a working condition. Where the instrument is received damaged no reading can be taken. __.' iaxiggi Ensue 241tri c$zG - ,�,4 - -: ---- -r3sffitlCai[:nfm,auixsis - U.x ory Inspection The calibration results published In this certAcAte Were otltalned uSinS equipmentcapadle of producing resufts that are tra[eable through MST to the Intgrndtlarwl 5}aten+ of Units i51i. CettHication only applies to rest, is shown. This certtficate may not be reproduced other than In full, except with the prier written approval of the issuing lahoratary. Pyle 2 c,ra I t3nI5LNANISr-t I Ce:jG:ztinn iaxWnrc: 107 tClC LmUmm N A www.gedenv.corn (800) 624-2026 info@gedenv.corn QED Environmental Systems Inc. 2355 Bishop Circle West, Dexter, MI 48130 i l J� CALIBRATION LOG LANDTEC - GEM 5000+ ES # 1255 ali t d ate ials re . METHANE Lot: 251297 HIGH Exp: 6/30/2024 I METHANE Lot: 251294 LOW Exp: 6/30/2024 OXYGEN Lot: 251253 HIGH Exp 6/30/2024 Carbon Filter Saturation (CH4) - Condition: PASS OXYGEN Lot: LOW Exp: CARBON Lot: MONOXIDE Exp: HYDROGEN Lot: SULFIDE - Exp: HBJ-161-4-3 11/11/2023 304-401897308-1 8/31/2024 304-401897307-1 8/31/2022 Gas Calibration Check Performed at Room Temperature SENSOR Initial Reading CAL eading Tolerance Comments CH4 (%) -0.1 0.0 +/- 0.5% CO m) -2.0 0.0 +/- 5 Rpm H2S ( m) 0.0 0.0 +/- 5 pprn H2 %) 1.0 0.0 +/- 1.5% SENSOR Initial Reading CAL Reading Tolerance Comments a o 0 0 - o SENSOR Initial Reading CAL Reading Tolerance Comments uu�a 10.4 10.0 +/-0.5% a +1-1.5% 02 o/a 0.0 0.0 +/- 1.5% SENSOR Initial Reading CAL Reading Tolerance Comments 02 (%) 21.3 20.9 +/- 0.5% SENSOR Initial Reading CAL Reading Tolerance Comments 02 (%) 4.1 4.0 +/- 0.5% SENSOR Initial Reading CAL Readin Tolerance Comments CO m 1014 1000 +/- 50 ppm SENSOR Initial Reading CAL Reading Tolerance Comments 1-12S ( m) 201 200 +/- 10 n m Signature: EUA Date: 07/06/2021 EASTERN SOLUTIONS, LLC (803) 746-5180 PACKING LIST GEM 5000 ES #: � a"�� Date: l a Standard Items Prepared QC Cl c.k Calibration Gases GEM 5000 CH Hi h -/ / a g S --psi Manual �_ '✓ CH4 Low 5­5-C) psi Factory Calibration Cert Oz Low 0 CJ psi Quick Reference Guide / OZ High psi Vinyl Tubing (Blue, Yellow, Clear) / CO psi Barbs (5) HZS � psi Water Trap Spare Water Trap Charcoal Filter Charger _� y Valves (Male/ Female) v Temperature Probe / v Calibration Gasses (6) Calibration Log Calibration Sticker ✓ Prepared By: 1 QC Check: Date: JOB NUMBER: 18151 O 0 LFG-5 N(SPC): 65496.51 E(SPC): 1161704.35 GROUN EL: 845.67' LFG-14 P OPOSED LFG PROBE FACILITY BOUNDARY LFG-15 PROPOSED LFG PROBE LFG-16 PROPOSED LFG PROBE / LFG-8 N(SPC): 565777.38 7 GROUND EL: 809.10' ): 1162340.97 ID EL: 831.48' N�(� r V—V : 565616.72 SPC): 1161995.05 GROUND EL: 857.60' PROBES TO BE CONVERTED TO LFG VENTS APPROXIMATE WASTE BOUNDARY FACILITY BOUNDARY N(SPC"" (SPC . ` E(SPC): 116298 . GROUND EL: 777. 10 ►. 5844.70 I: 11 3230.39 D E 758.79' NOTE: All Locations and Elevations e based on VRS Data Utilizing SPC/NC32 , NAD83(2011), and GEOIDI28 Datums. El UNUSED BLOCK / BUILDING 'LFG-12 LFG-13 N(SPC): ;L-5 67.67 XOUNDARY---,,.N(SPC : E(SPC): 180.19 ): 1162921.07 GROUND 787.66' L• 78228 LFG- N(SPC): 5218.95 E(SPC): 116 68.23 GROUND EL: .59' LFG- / N C): 75. (SPC 162 .12 G" ND 793.08' LFG- N 56 93' i LFG-2 N(SPC): 564996. E(SPC): 11 2.63 G EL: 80.. ' .w.: 4, . SPAPOLIM ... FlwNG RAN •, .-,7 F�= (OPENI SIRUCTUIAN� w LFG-11 N(SPC): 565285.97 E(SPC): 1163906.46 GROUND EL: 786.70' "�� #2 BLD� FACILITY BOUNDARY 100 0 50 100 GRAPHIC SCALE FACILITY BOUNDARY 200 300 I INCH = 100 FEET w a 0 R. W N V) I q- I LO 1 c0 0_ I HEREBY CERTIFY THAT THIS PLAN AND SPECIFICATION WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY REGISTERED ARCHITECT OR ENGINEER UNDER THE LAWS OF THE STATE OF NORTH CAROLINA AS SIGNIFIED BY MY HAND AND SEAL. `,`I11111111/,`�� CARof'''. SS �po,�,: s = 21 = I�' I 0%%` i � I CF CA-'=1-1T U z 0 � W � N z O � O J U � O LL- J O � Z o' Ljj ^ 4 Q C/7 = ` � 1 � Z W Z < Z 0 � O — J U LL- � 0 Z a p J L` LAmJ U S LLI O WJ N � � W z� N b.0 r ^^ O o w az SCALE: 1 "=100' DATE: 10/18/18 DRAWN BY: PED CHECKED BY: DWO PROJECT MGR: DWO SHEET: 1 OF 1 0