HomeMy WebLinkAbout23077_Diversey Water Technologies_SIR_2021.5.19
DWM Brownfields Inspection Report
Submitted By: jkslaughter_ncdenr
Submitted Time: 05/20/2021 3:07 PM
I. Inspection Information
Date & Time: 05/19/2021 9:51 AM Inspection Type: Meeting
Brownfields Staff:
Kevin Slaughter
Other Personnel:
Andrew Besu and field staff - H&H
Location:
Lat: 35.22249, Long: -80.85747,
Brownfields Inspection Report: Diversey Water Technologies, 23077-19-060
05/19/2021 9:51 AM
Page 2 of 7
II. Project Information
Number: 23077-19-060 Name: Diversey Water Technologies
Address: 1200, 1208,1210,
and 1212 S. Mint Street; 1201
S. Graham Street
City: Charlotte
County: Mecklenburg
III. Environmental
Current Use of Property: Commercial/Retail, Residential
Structures on Property: New Structures Violation: No
Vapor Mitigation Systems: Observed Vapor Mitigation Violation: No
Use of Surface Water or Groundwater: Not Observed Water Use Violation: No
Exposed Soils: Observed Exposed Soils Violation: No
Summary: Sub-slab piping, barrier, and concrete pour was supposed to be completed on
portion of site VIMS communication was being performed on at the time of inspection.
Following set-up of communication testing equipment, determined final sealing of edges
of VIMS barrier had not been completed prior to testing, and following set-up,
communication testing was temporarily canceled.
Summary: N/A
Summary: New high-density apartments and retail space currently under construction.
Summary: Typical exposed soils present as would be expected on an active construction
site.
Brownfields Inspection Report: Diversey Water Technologies, 23077-19-060
05/19/2021 9:51 AM
Page 3 of 7
Use of Basements: Not Observed Basement Violation: No
Storage of Chemicals: Not Observed Chemical Violation: No
Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No
Current Exposure to Public/Public Risk:
Summary: N/A
Summary: N/A
Condition:
Summary: N/A
Site perimeter fenced with temporary construction fencing; site access strictly controlled.
No public exposure identified at the time of the Site Inspection.
Brownfields Inspection Report: Diversey Water Technologies, 23077-19-060
05/19/2021 9:51 AM
Page 4 of 7
IV. Inspector Comments
V. PHOTOGRAPHS
Photo 1: View of site facing northeast from S. Graham St.
Onsite to observe communication testing on Area B (northwest corner) of apartment
building. Double sided adhesive tape has pulled loose from portion of slab, although
there is an additional lower seal in place. Upper seal to be replaced. There is a sec
Brownfields Inspection Report: Diversey Water Technologies, 23077-19-060
05/19/2021 9:51 AM
Page 5 of 7
Photo 2: Fan riser F-6 on northern side of apartment complex.
Photo 3: VIMS communication testing within Areas B and C on VIMS Plan). Temporary fans set
up on VIMS risers F-6 (foreground), F-5 (distant background), and F-4 (not visible) prior to
anticipated testing on northern side of building.
Brownfields Inspection Report: Diversey Water Technologies, 23077-19-060
05/19/2021 9:51 AM
Page 6 of 7
Photo 4: VIMS barrier prior to adhering to perimeter of slab.
Photo 5: Gaps in VIMS barrier within future ramp location. These will be resealed prior to
communication testing and pouring of concrete ramp.
Brownfields Inspection Report: Diversey Water Technologies, 23077-19-060
05/19/2021 9:51 AM
Page 7 of 7