Loading...
HomeMy WebLinkAbout9209_Wake_NorthWakeUnlined_MSWLF_March21GW_FID1586419_20210611North Wake Unlined Landfill Facility Permit No. 9209-MSWLF-1984 Semi -Annual Groundwater Sampling Report (March 2021 Sampling Event) Wake County Prepared June 2021 WAKE COUNTY NORTH CAROLI NA R USE ONLY ❑Paper Report �Electronk Data - Email CD (data loatlatl' Yes / No) DodE nt# 'NC DENR Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Nodded This Mon and any information attached to it are'Public Recortls as Oefinetl in NC Geneml Stable 132-1. As such, these documents am available for inspection and examination by any person upon request INC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or pant legibly. Aimed a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occumng, offsfte source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. • Atach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B A629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Dada Deliverable to: Compliance Unit, NCDENR-0WM, Sold Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646, Solid Waste Monitoring Data Submittal Information Name of emit' submitting data (laboratory, conauttant, facility owner): Consultant- CDM Smith Inc. Contact for Questions about data Ferretti Include data preparers name, telephone number and Earned address: Name: Mathew F.Cobne Phone:(919) 32S.3s00 E-mail: celonemf($cdmsmith.com NC Landfill Rule: Actual sampling dam (e.g., Facility name: Facility Address: Facility Permit if (.050) or.16001 Otlaher2&2d_ 2mfil Wake County - North Wake Closed Unlined Landfill 9004 Deponle Drive Raleigh, North Carolina 27616 9209,MSWLF- 1984 .1600 March 31, 2021 Environmental StaWs: (Check all that apply) InitiaVBacground Monitoring Q Detection Monitoring ® Assessment Mainitoorig © Corrective Action Type of data submitted: (Check all that apply) II')IX—(III Groundwater monitoring data from monitoring wells ❑ Methane gas MonitMng data Groundwater monitoring data from private water supply wells X❑ Conec ive action data (specify) MNA Sampling Results Leachate monitoring data Surface water monitoring data ElOgrer(sperdy) Notification attached No. No groundwater or surface water standards were exceeded. X Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water onidodng points, dates, analytical values, NC 2L groundwater standard, NC 28 surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any co centmtion. ❑ Yes, a nofi( lion of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring pants, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and turfed Furthermore, 1 have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. 1 am aware that them are significant Penalties for making any false statement representation, or certification including the possibility of a fine and imprisonment. Mathew F. Colons Consultant (919) 32&3500 Facit if p ems' a (Print) Title 7 (Free Codel TNePhone Num)4rs" - -' //�� /,�Z ( Aid NC D�t�P ogist Seal Signature l I F�?- of t . 9n D to ad 5400 Glenwood Avenue, Suite 400, Raleigh, North Carolina 27612 }`Id Facility Representative S y/fi/p F-0412 a4 NC PE Fare License Number ('rf applicable effective May i, 2W9) t, ` Revised 64WO9 G,N�7n � Smith 5400 Glenwood Avenue, Suite 400 Raleigh, North Carolina 27612 tel: 919 325-3500 fax: 919 781-5730 June 11, 2021 Ms. Jaclynne Drummond North Carolina Department of Environmental Quality Division of Waste Management Solid Waste Section 2090 U.S. 70 Highway Swannanoa, North Carolina 28778 Subject: March 2021 Semi -Annual Groundwater Sampling Report North Wake Closed Unlined Landfill Facility Permit No. 9209-MSWLF-1984 Dear Ms. Drummond: CDM Smith Inc. (CDM Smith), on behalf of Wake County (County), is submitting an electronic copy of the March 2021 semi-annual sampling event report. This letter report presents the results of the semi-annual sampling event that was recently completed at the North Wake Closed Unlined Landfill (Site) and constitutes the first semi-annual sampling event for 2021. The groundwater monitoring network consists of the following wells: MW-11 (shallow background well), -11d (deep background well), -5R, -6, -6d, -7, -8, -8d, -9, -10, -10d, -22, -23, -23d, -24, -28, -28d, -29d, -30, -31, -31d, -32, -33, -34, -34d, -35, -36, -36d, TB-1a and TB-1a deep. Surface water sampling locations include SW-2, -3, -7, and -8. Field activities, sampling results for all wells and surface water locations, an evaluation of the groundwater corrective action effectiveness, and recommendations are discussed below. Field Activities Groundwater and surface water samples from the Site were collected on March 31, 2021. Monitoring well and surface water sample locations are shown on Figure 1. Construction details for each monitoring well are summarized in Table 1. Samples were collected from the monitoring wells by use of a peristaltic pump or disposable, laboratory decontaminated bailers. Groundwater elevations were measured at each well on March 29, 2021, prior to sampling using an electronic water level indicator with an accuracy of 0.01 feet and are presented in Table 1. These groundwater elevations were used to construct potentiometric contours for this sampling event and are shown on Figure 1. The groundwater elevations and potentiometric contours were also used to estimate groundwater velocities at each well as presented in Table 2. Of WATER + ENVIRONMENT +TRANSPORTATION + ENERGY + FACILITIES Smith Ms. Jaclynne Drummond June 11, 2021 Page 2 After depth to groundwater was measured, three well volumes of water were removed from each well prior to sampling to provide fresh formation water within the well water column. Each well volume and surface water sample were measured for pH, conductivity, temperature, turbidity, dissolved oxygen (DO), and oxidation-reduction potential (ORP) using a YSI-556 multi -parameter water quality meter and a HANNA HI 98703 turbidity meter. Wells that had elevated turbidity were allowed to stabilize prior to sample collection. No water quality parameters were measured in monitoring wells MW-22, -24, -30, and TB-1a, except for turbidity, due to an insufficient volume of water in the wells. These wells were purged dry prior to evacuating one well volume and were allowed to recharge overnight before sample collection. The water quality measurements at the time of sample collection are provided in Table 3. Alternate Source Demonstration On August 17, 2020, CDM Smith submitted an Alternate Source Demonstration (ASD) for the Site on behalf of the County. The purpose of the ASD was to demonstrate that metals exceeding the 15A NCAC 02L .0202 (NC 2L) Groundwater Standards or Interim Maximum Allowable Concentrations (IMAC) are naturally occurring and not related to a release from the landfill. The ASD was prepared using analytical data from the background monitoring wells, MW-11 and -11D, that was collected on a quarterly basis from January 2018 to April 2020 to develop upper tolerance limits (UTLs) for specific analytes that historically exceeded their respective NC 2L Groundwater Standard or IMAC. Based on statistical analysis, a UTL of 6 parts per billion (ppb) was proposed for cobalt and a UTL of 23 ppb was proposed for vanadium. The North Carolina Department of Environmental Quality's (NCDEQ) Solid Waste Section (SWS) approved these proposed UTLs on August 17, 2020. Sampling Results All groundwater and surface water samples were analyzed by Pace Analytical Services, LLC located in West Columbia, South Carolina, for North Carolina Appendix I volatile organic compounds (VOCs) plus dichlorodifluoromethane and Appendix I metals plus mercury. Samples from monitoring wells MW-5R, -6, -8, -9, -10, -11, -34, -34d, and -36 were also analyzed for natural attenuation parameters (i.e., biochemical oxygen demand (BOD), chemical oxygen demand (COD), alkalinity, nitrate, chloride, sulfate, sulfide, total organic carbon (TOC), carbon dioxide, methane, ethane, ethene, ferrous iron, volatile fatty acids, and dissolved hydrogen) per the Corrective Action Plan (CAP) and CAP Addendum that were approved by the SWS in March 2010 and on June 10, 2019, respectively. Monitoring wells MW-5R, -34, and -34d were also analyzed for total iron, sodium, and total dissolved solids. The CAP and CAP Addendum are discussed below. In a letter dated May 29, 2018, the SWS stated that all groundwater and surface water samples collected from landfills be analyzed for 1,4-dioxane after July 1, 2018. On June 26, 2019, the SWS approved the removal of 1,4-dioxane from the sampling program for all monitoring wells and surface water locations, with the exceptions of MW-6, -8, and -9, due to two non -detect events (October 2018 0 Smith Ms. Jaclynne Drummond June 11, 2021 Page 3 and April 2019). Samples were collected from the wells requiring the 1,4-dioxane analysis during the March 2021 sampling event. Sample results are provided below. The analytical results were reported to the laboratory specific method detection limit (MDL) and are quantifiable at or below the laboratory limit of quantitation (LOQ). All monitoring wells for the Site had detections of analytes above the MDL but below the LOQ that were qualified as estimated or "J" flags. In samples collected from MW-5R and -9, BOD was qualified with a "4" flag, indicating that the method blank result was higher than the method required limit of 0.20 milligrams per liter. In samples collected from MW-11d and -34d, acetone was qualified with an "L" flag, indicating a laboratory control spike/laboratory control duplicate failure. In MW-5R and -8, acetone had an "H" flag, indicating that the analyte was analyzed outside of hold time. Chloride, nitrate, and methane detections in samples collected from MW-5R were qualified with a "D" flag, indicating that the analytes were analyzed at a dilution greater than 1. The detection of methane in MW-5R also had a "B" flag, indicating that the analyte was detected in the method blank. In samples collected from MW-31, chromium had an "S" flag, indicating a matrix spike/matrix spike duplicate failure. Chromium also had a "B" flag in samples collected from MW-11d. The following list summarizes which analytes were detected above the LOQ at each sample location. Underlined analytes exceeded the NC 2L Groundwater Standard, IMAC, UTL, or the 15A NCAC 02B (NC 2B) or North Carolina In -Stream Target Value Surface Water Quality Standard for Class C Waters. No "J" flag detections are listed. A complete summary of all detected and estimated concentrations from the November 2011 through the March 2021 sampling events is presented in Table 4. Laboratory data reports are provided in Appendix A. MW-11 (Shallow Background) Metals: Volatile Organic Compounds: MW-11d (Deep Background) Metals: Volatile Organic Compounds: MW-SR Metals: Volatile Organic Compounds MW-6 Metals: Volatile Organic Compounds Barium None Detected Barium, Zinc None Detected Barium, Cobalt, Nickel, Zinc Acetone, Ethylbenzene, Toluene Barium, Cobalt 1,4-DichIorobenzene, 1,4-Dioxane 0 Smith Ms. Jaclynne Drummond June 11, 2021 Page 4 MW-6d Metals: Barium Volatile Organic Compounds: 1,1-Dichloroethane MW-7 Metals: Barium, Cobalt, Copper, Lead, Nickel, Vanadium, Zinc Volatile Organic Compounds: Benzene, Chlorobenzene, Chloroethane, 1,4-Dichlorobenzene MW-8 Metals: Barium, Cadmium, Chromium, Nickel, Vanadium, Zinc Volatile Organic Compounds: Benzene, 1,4-Dichlorobenzene, cis-1,2-Dichloroethene MW-8d Metals: Barium, Lead, Vanadium Volatile Organic Compounds: None Detected MW-9 Metals: Barium, Chromium, Copper, Lead, Nickel, Vanadium, Zinc Volatile Organic Compounds: Chloroethane, 1,4-Dichlorobe nzene, 1,1-Dichloroethane, cis- 1,2-Dichloroethene, 1,4-Dioxane, Vinyl Chloride MW-10 Metals: Barium, Cadmium, Chromium, Copper, Zinc Volatile Organic Compounds: None Detected MW-10d Metals: Zinc Volatile Organic Compounds: 1,1-Dichloroethane MW-22 Metals: Barium, Cadmium, Cobalt Volatile Organic Compounds: None Detected MW-23 Metals: Barium, Copper, Lead, Vanadium, Zinc Volatile Organic Compounds: None Detected MW-23d Metals: Barium, Chromium, Zinc Volatile Organic Compounds: None Detected 0 Smith Ms. Jaclynne Drummond June 11, 2021 Page 5 M W-24 Metals: Barium Volatile Organic Compounds: Chloroform MW-28 Metals: Barium, Chromium, Lead, Vanadium, Zinc Volatile Organic Compounds: None Detected MW-28d Metals: Barium, Lead, Nickel, Vanadium, Zinc Volatile Organic Compounds: None Detected MW-29d Metals: Barium, Chromium, Copper, Nickel, Zinc Volatile Organic Compounds: None Detected MW-30 Metals: Barium, Chromium, Copper, Lead, Vanadium, Zinc Volatile Organic Compounds: None Detected MW-31 Metals: Barium, Chromium, Copper, Lead, Vanadium Volatile Organic Compounds: None Detected MW-31 d Metals: Barium, Vanadium, Zinc Volatile Organic Compounds: Chloroform MW-32 Metals: Barium, Zinc Volatile Organic Compounds: Chloroform TB-1 a Metals: Barium, Cadmium, Chromium, Zinc Volatile Organic Compounds: None Detected TB-1a deep Metals: Barium, Zinc Volatile Organic Compounds: None Detected 0 Smith Ms. Jaclynne Drummond June 11, 2021 Page 6 MW-33 Metals: Barium, Chromium Volatile Organic Compounds: None Detected MW-34 Metals: Barium, Beryllium, Chromium, Cobalt, Copper, Lead, Nickel, Vanadium, Zinc Volatile Organic Compounds: 1,1-Dichloroethane, cis- 1,2-Dichloroethene, Methylene Chloride, Tetra chloroethene (PCE), Trichloroethene (TCE) MW-34d Metals: Barium, Cadmium, Chromium, Zinc Volatile Organic Compounds: 1,1-Dichloroethane, cis- 1,2-Dichloroethene, Methylene Chloride MW-35 Metals: Barium, Beryllium, Zinc Volatile Organic Compounds: Dichlorofluoromethane MW-36 Metals: Barium, Chromium, Copper, Vanadium, Zinc Volatile Organic Compounds: 1,1-Dichloroethane, cis- 1,2-Dichloroethene MW-36d Metals: Barium, Chromium, Copper, Zinc Volatile Organic Compounds: cis- 1,2-Dichloroethene SW-2 Metals: Barium, Copper, Lead, Vanadium, Zinc Volatile Organic Compounds: None Detected SW-3 Metals: Barium Volatile Organic Compounds: None Detected SW-7 Metals: Barium Volatile Organic Compounds: None Detected SW-8 Metals: Barium Volatile Organic Compounds: None Detected iD Smith Ms. Jaclynne Drummond June 11, 2021 Page 7 "J" flags were not included in the previous list, but MW-10d had a "J" flag detection of antimony that exceeded its IMAC. It is likely that the recent and historic detections of chloroform in wells MW-6d, -24, -31, -31d, -32, TB-1a, and -1a deep are attributed to a release from a municipal water line in the Falls River development and are not related to a release from the Site. In a letter dated March 22, 2012, the SWS approved the County's request to discontinue collecting samples from select wells for herbicide and pesticide analyses during the semi-annual spring sampling event. However, the SWS requested that MW-29d continue to be sampled for bis(2-ethylhexyl) phthalate during spring sampling events due to a detection from the March 2011 event. Bis(2-ethylhexyl) phthalate was detected above the NC 2L Groundwater Standard (3 parts per billion (ppb)) at 28.5 ppb in samples collected from MW-29d during the April 2014 sampling event. A confirmatory sample collected from MW-29d during the November 2014 sampling event had an estimated detection of bis(2-ethylhexyl) phthalate at 4.61 ppb, which is above the standard. Bis(2- ethylhexyl) phthalate has not been detected above the laboratory MDL in samples collected from MW-29d since the November 2014 sampling event, except for estimated detections below the NC 2L Groundwater Standard in samples collected during the 2018 and April 2020 events. The concentration trend for bis(2-ethylhexyl) phthalate in MW-29d will continue to be evaluated. Equipment and trip blanks were analyzed for quality control. A duplicate sample was also collected for quality control. Acetone and 2-butanone were detected as estimated concentrations in the equipment blank below their respective NC 2L Groundwater Standards. There were no detections in the trip blank above the MDLs. The duplicate sample, identified as DUP, was collected from MW-8d and had similar analyte concentrations as those detected in MW-8d. Table 5 presents a summary of all analytes detected during the March 2021 sampling event that exceeded the NC 2L Groundwater Standards, IMACs, or UTLs. Additional metals sample was collected from monitoring wells MW-5R, -6, -7, -22, -23, -28, -28d, 30, -31, -32, -34, -36, -36d, and TB-1a during the March 2021 sampling event for the laboratory to filter and analyze due to elevated turbidity (i.e., greater than 10 Nephelometric Turbidity Units) at the time samples were collected. Total metals that exceeded the NC 2L Groundwater Standards, IMACs, or UTLs in MW-6, -7, -30, -34, and -36 were analyzed for dissolved metals to determine if turbidity was a contributing factor to total reported metals. MW-5R, -22, -31, -36d, and TB-1a had total metals that exceeded the standards but samples collected from these wells were not analyzed for dissolved metals due to laboratory error. Dissolved chromium exceeded the NC 2L Groundwater Standard in samples collected from MW-6 and dissolved cobalt exceeded the UTL in samples collected from MW-34. Based on qualitative and quantitative evaluation of current and historic groundwater sampling data, the NC 2L Groundwater Standard, IMAC, or UTL metal exceedances from the March 2021 sampling event were determined to be indicative of naturally occurring background concentrations as opposed to a release from the 0 Smith Ms. Jaclynne Drummond June 11, 2021 Page 8 landfill. Dissolved metal sample results are provided in Table 4 and the laboratory data report is provided in Appendix A. Corrective Action via Air Sparging The SWS expressed concern in May 2008 that VOCs may be migrating beyond the Site property boundary and into Abbott's Creek based on detections above the NC 2L Groundwater Standard in monitoring well MW-9. As a result, the SWS directed the County to install and sample groundwater monitoring wells, one shallow and one deep (i.e., MW-36 and -36d), downgradient of MW-9 to determine if VOCs may be migrating beyond the Site property boundary, possibly discharging into Abbott's Creek. Initial groundwater samples collected from MW-36 and -36d in December 2008 had detections of VOCs above NC 2L Groundwater Standards. Surface water sample locations SW-7 and -8, located on Abbott's Creek, were added to the semi- annual monitoring program in November 2008. Samples collected from SW-7 and -8 since being added to the monitoring program have never had VOCs detected above the NC 2B Surface Water Quality Standards. An Assessment of Corrective Measures Report was submitted to the SWS in accordance with the North Carolina Solid Waste Management Rule 15 NCAC 13B .1635 and approved in December 2009. The SWS approved the selected remedy of monitored natural attenuation paired with in situ remediation by air sparging to address groundwater contamination at the facility. A pilot test was conducted in July and August 2010 near MW-6 and -6d to evaluate the effectiveness of the air sparging remedy and to collect data for the full-scale system design in accordance with the CAP. The pilot test successfully reduced the concentrations of 1,1-dichloroethane and vinyl chloride to below their respective NC 2L Groundwater Standard in MW-6d and vinyl chloride was not detected in samples collected from MW-6 during the October 2010 semi-annual sampling event. The full-scale system was installed in October 2011 and was operational in August 2012. The air sparging system consists of 15 shallow wells screened across saturated saprolite and partially weathered rock and 14 wells screened in the shallow fractured bedrock. In addition to the air sparging wells, the system also consists of an air compressor and control panel that are housed in a secured on -site control building. Routine inspections are performed on the system and a Field Inspection Log completed during each inspection is kept on file at the facility. The County installed a vacuum extraction system around the perimeter of the Site in January 2002 to prevent offsite migration of soil gas. The air sparging system was designed to work in tandem with the existing perimeter migration control system (PMCS) by recovering air and gas vapors produced by the air sparging system. Since previous work has indicated a relationship between the soil gas and the contaminated groundwater, the installation of the PMCS is likely to further reduce groundwater tD Smith Ms. Jaclynne Drummond June 11, 2021 Page 9 contaminant concentrations. As discussed in the approved CAP, the vacuum extraction system will be used in conjunction with the air sparging system to reduce VOCs in the bedrock and partially weathered rock between MW-9 and the MW-6 nested pair. As part of the corrective action effectiveness evaluation, contaminant concentration trends for monitoring wells MW-6, -6d, -9, -36, and -36d were evaluated. Total VOC concentration trends for each well are presented on Figures 2 through 6. Trend results for each well are discussed below. Figure 2 presents a total VOC concentration trend analysis for samples collected from MW-6. VOCs in MW-6 significantly decreased after January 2002 when the PMCS was operational and were not detected from November 2004 to April 2007. The total VOC concentration in MW-6 increased in May 2008 to 24 ppb compared to the November 2007 concentration of 14 ppb. The total VOC concentration in MW-6 showed a decreasing trend from May 2008 to April 2018 but has increased since the introduction of the 1,4-dioxane analysis in October 2018. The total VOC concentration in MW-6 has fluctuated since October 2018. Vinyl chloride has not been detected above the laboratory MDL in MW-6 since the April 2013 sampling event. Benzene detections in MW-6, which historically have exceeded the NC 2L Groundwater Standard, have been below the laboratory MDL since April 2013 except for the November 2014 sampling event when it was detected slightly above the standard at 1.1 ppb and October 2018 when it was detected above the MDL at 0.61 ppb. The trend analysis for total VOC concentrations in MW-6d is presented on Figure 3. VOCs were not detected at MW-6d from December 2001 through November 2007. The increase in total VOCs from samples collected during the May 2008 sampling event is a result of reporting "J" flag detections as required by the SWS. VOC concentrations in MW-6d have been below the NC 2L Groundwater Standards since the March 2011 sampling event and show a decreasing trend. Figure 4 presents a total VOC concentration trend analysis for samples collected from MW-9. Historically, MW-9 has had the highest concentration of VOCs compared to the other monitoring wells. VOCs were not detected as an estimated concentration above the NC 2L Groundwater Standards in MW-9 from October 2012 through April 2015. Benzene, 1,4-dichlorobenzene, 1,2- dichloroethane, 1,4-dioxane, and vinyl chloride have recently been detected above their respective NC 2L Groundwater Standards in MW-9. The total VOC concentration trend has been slightly increasing at MW-9 since the October 2018 sampling event. Trend analyses for total VOC concentrations in MW-36 and -36d are presented on Figures 5 and 6, respectively. Vinyl Chloride was detected above its NC 2L Groundwater Standard during the October 2020 sampling event for the first time in samples collected from MW-36 since March 2011, but total VOC concentrations have shown a decreasing trend since the air sparging system has been iD Smith Ms. Jaclynne Drummond June 11, 2021 Page 10 operational. No VOCs have been detected above the NC 2L Groundwater Standards in MW-36d since the October 2015 sampling event. Total VOC concentrations in both monitoring wells will continue to be monitored and are expected to decrease while the air sparging system is operational. Additional groundwater samples were collected from MW-51R, -6, -8, -9, -10, -11, and -36 for evaluation of monitored natural attenuation parameters as part of the corrective action program as required by SWS guidelines. Geochemical results are presented in Table 6. The laboratory data for the additional parameters is included in Appendix A. As discussed in the approved CAP, concentrations of some of the natural attenuation data from select wells indicates that environments are present which favor reductive dechlorination; notably, the concentrations of nitrate, ferrous iron, sulfate, and carbon dioxide. The following evidence indicates that one or more mechanisms of natural attenuation and/or reductive dechlorination may be occurring at the site: • VOC concentrations in contaminated wells continue to decline; • The ratio of parent to daughter compounds continues to decrease over time; • Nitrate, ferrous iron, sulfate, and carbon dioxide continue to be detected at concentrations favoring reductive dechlorination; and • Concentrations of cis-1,2-dichloroethene continue to be greater than dichloroethene isomers trans-1,2-dichloroethene and 1,1-dichloroethene. Corrective Action via In Situ Bioremediation Injection VOCs that exceed the NC 2L Groundwater Standards, including benzene, 1,4-dichIorobenzene, 1,1-dichloroethane, methylene chloride, PCE, TCE, and vinyl chloride, have been detected in the area of MW-51R, -34, and -34d. MW-5R is located near the Site property line and the MW-34 cluster is located east of MW-5R on the adjacent parcel, more than 900 feet from the air sparging system. The VOC exceedances are likely from the migration of leachate from the Site into the surficial aquifer. In accordance with the CAP Addendum that was approved by the SWS on July 10, 2019, and an injection permit obtained from the Division of Water Quality — Underground Injection Control Program on July 24, 2019, an in situ enhanced anaerobic bioremediation (EAB) injection was completed by adding sodium lactate and emulsified vegetable oil (EVO) substrates through a biobarrier injection system to reduce total VOC concentrations at the property line. Sodium lactate and EVO enhance biologically reducing conditions that favor and support dechlorination of VOCs to non -toxic end products. On August 26-28, 2019, eight injection wells (i.e., NWIW-1 through -8) were installed upgradient of MW-51R, -35, and -34d, as shown on Figure 1. An initial injection of sodium lactate was completed from October 8-16, 2019. A total of 54,181 gallons of a 2.4 percent sodium lactate solution were 0 Smith Ms. Jaclynne Drummond June 11, 2021 Page 11 injected. Post -sodium lactate injection samples were collected 1 month after the injection during the November 2019 semi-annual sampling event. Samples collected from monitoring wells MW-5R, -34, and -34d were analyzed for natural attenuation parameters, sodium, total iron, and total dissolved solids. Analytical results are summarized in Tables 4 and 6. The EVO injection was completed on November 18-30 and December 1-6, 2019, with a 3.3 percent solution of 98 percent LactOil° EVO formulation. A total of 80,751 gallons of the solution was injected. The effectiveness of the EAB injection was evaluated with quarterly sampling of MW-5R, -34, and -34d on February 4, April 8, July 30, and October 15, 2020. A report summarizing the results of the EAB injection will be submitted to the SWS in June 2021. Chlorinated VOC data were reviewed to evaluate concentration trends over time and to determine if dechlorination is occurring. Total VOC concentration trends for each well are presented on Figures 7 through 9. Trend results for each well are discussed below. The VOC trend analysis for MW-5R is presented on Figure 7. TCE has never been detected above the NC 2L Groundwater Standard in MW-5R and PCE has never been detected above the MDL. Vinyl chloride was the most recent analyte detected above the NC 2L Groundwater Standard (April 2019). The geochemical data indicates reducing conditions to support anaerobic dechlorination at MW-5R, shown by decreasing levels of sulfate, nitrate, DO, and negative values of ORP. The trend analyses for MW-34 and -34d are presented on Figures 8 and 9, respectively. Since the injections, PCE, TCE, and 1,1-dichloroethane concentrations have fluctuated. Total VOCs and concentrations of methylene chloride and cis-1,2-dichloroethene show a decreasing trend in MW-34. Total VOC concentrations in MW-34d have slightly increased, but concentrations of chlorinated VOCs are expected to decrease as the reducing conditions at the upgradient biobarrier support dechlorination. Recommendations The County will continue with the semi-annual assessment monitoring program. In addition to sampling for Appendix I metals plus mercury, Appendix I VOCs plus dichlorodifluoromethane, and the Appendix II constituent, bis(2-ethylhexyl) phthalate (sampled at MW-29d only during the spring sampling event), samples collected from MW-5R, -6, -8, -9, -10, -11, -34, -34d, and -36 will continue to be analyzed for natural attenuation parameters during the semi-annual events. MW-6, -8, and -9 will continue to be analyzed for 1,4-dioxane. The air sparging system will continue to operate and the effectiveness of the system will be re-evaluated after the next semi-annual sampling event in the fall of 2021. 0 Smith Ms. Jaclynne Drummond June 11, 2021 Page 12 If you have any questions or require further explanation, do not hesitate to call me at (919) 325-3500. Sincerely, %&1VAA- Mathew F. Colone, P.G. CDM Smith Inc. cc: John Roberson, WCSWM Elliott Cornell, WCSWM 0 Table 1 Monitoring Well Construction Summary and Groundwater Elevations March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 Depth Permit Monitoring Completion I Screened Total Number Well Code Date Lattitude Longitude Lithology (feet below I I TOC) 9209-MSWLF-1984 MW-5R 1/30/2004 35.91192 78.57159 Regolith 27.5 .-3/29/2021 DiameterFacility Screen, Filter Seal Casing I In terva Interval Interval (inches) Elevation Groundwater Elevation 10.0-25.0 8.0-25.0 6.0-8.0 2 225.28 13.98 211.30 9209-MSWLF-1984 MW-6 March-94 35.91423 78.57122 Regolith 22.0 -- 10.0-20.0 8.0-20.0 6.0-8.0 2 219.80 11.72 208.08 9209-MSWLF-1984 MW-6d 5/1/2001 35.91423 78.57122 Bedrock 65.0 0-45.0 52.0-62.0 50.0-62.0 48.0-50.0 2 218.61 12.46 206.15 9209-MSWLF-1984 MW-7 March-94 35.91098 78.57436 Regolith 21.5 9.0-19.0 7.0-19.0 5.0-7.0 2 234.15 12.12 222.03 9209-MSWLF-1984 MW-8 March-94 35.91078 78.57266 Regolith 21.5 -- 9.0-19.0 7.0-19.0 5.0-7.0 2 226.38 11.22 215.16 9209-MSWLF-1984 MW-8d 5/3/2001 35.91078 78.57266 Bedrock 45.0 0-30.0 37.0-42.0 35.0-42.0 29.0-35.0 2 226.16 12.05 214.11 9209-MSWLF-1984 MW-9 March-94 35.91484 78.57273 Regolith 44.0 -- 32.0-42.0 30.0-42.0 28.0-30.0 2 242.69 29.69 213.00 9209-MSWLF-1984 MW-10 4/1/1998 35.91499 78.57494 Bedrock 55.5 43.0-53.0 41.0-53.0 39.0-41.0 2 274.76 41.44 233.32 9209-MSWLF-1984 MW-10d 5/1/2001 35.91499 78.57494 Bedrock 93.0 80.0-90.0 78.0-92.0 75.0-78.0 2 274.54 45.60 228.94 9209-MSWLF-1984 MW-11 Oct1995 35.90574 78.58251 Regolith 57.0 39.0-54.0 37.0-54.0 35.0-37.0 2 343.63 41.59 302.04 9209-MSWLF-1984 MW-11d Oct1995 35.90578 78.58248 Bedrock 72.0 64.0-69.0 62.0-69.0 60.0-62.0 2 343.27 41.80 301.47 9209-MSWLF-1984 MW-22 June-97 35.91596 78.57453 Regolith 39.0 27.0-37.0 25.0-37.0 23.0-25.0 2 254.62 33.10 221.52 9209-MSWLF-1984 MW-23 June-97 35.91373 78.57540 Regolith 50.0 38.0-48.0 36.0-48.0 34.0-36.0 2 274.83 43.18 231.65 9209-MSWLF-1984 MW-23d 4/27/1998 35.91373 78.57540 Bedrock 91.0 0-43.0 78.0-88.0 76.0-88.0 74.0-76.0 2 274.89 43.35 231.54 9209-MSWLF-1984 MW-24 June-97 35.91232 78.57546 Regolith 47.5 35.0-45.0 33.0-45.0 31.0-33.0 2 266.64 43.93 222.71 9209-MSWLF-1984 MW-28 4/9/1998 35.91644 78.57439 Regolith 30.0 -- 20.0-30.0 18.0-30.0 16.0-18.0 2 237.89 16.84 221.05 9209-MSWLF-1984 MW-28d 4/22/1998 35.91644 78.57439 Bedrock 51.0 0-28.0 41.0-51.0 39.0-51.0 37.0-39.0 2 238.44 16.89 221.55 9209-MSWLF-1984 MW-29d 4/22/1998 35.91472 78.57572 Bedrock 52.0 0-40.5 47.0-52.0 45.0-52.0 43.0-45.0 2 275.06 40.02 235.04 9209-MSWLF-1984 MW-30 4/14/1998 35.91374 78.57596 Regolith 55.0 40.0-55.0 38.0-55.0 36.0-38.0 2 282.32 46.57 235.75 9209-MSWLF-1984 MW-31 4/2/1998 35.91231 1 78.57595 Regolith 35.5 -- 25.5-35.5 23.0-35.5 21.0-23.0 2 261.67 29.80 231.87 9209-MSWLF-1984 MW-31d 4/23/1998 35.91231 78.57595 Bedrock 66.0 0-51.0 56.0-66.0 54.0-66.0 52.0-54.0 2 260.92 29.50 231.42 9209-MSWLF-1984 MW-32 4/3/1998 35.91142 78.57564 Regolith 26.0 13.0-23.0 11.0-23.0 9.0-11.0 2 242.99 14.39 228.60 9209-MSWLF-1984 TB-1a 4/7/1998 35.91188 78.57595 Regolith 30.0 20.0-30.0 17.5-30.0 14.0-17.5 2 255.05 26.12 228.93 9209-MSWLF-1984 TB-1a deep 5/7/2001 35.91188 78.57595 Bedrock 62.0 0-23.0 52.0-62.0 50.0-62.0 47.0-50.0 2 256.01 28.50 227.51 9209-MSWLF-1984 MW-33 7/22/1998 35.91077 78.57169 Regolith 28.0 10.0-25.0 8.0-25.0 6.0-8.0 2 222.01 10.26 211.75 9209-MSWLF-1984 MW-34 7/23/1998 35.91192 78.57116 Regolith 28.0 -- 15.0-25.0 13.0-25.0 11.013.0 2 221.96 11.61 210.35 9209-MSWLF-1984 MW-34d 7/23/1998 35.91192 78.57116 Bedrock 58.0 0-38.0 45.0-55.0 43.0-55.0 41.0-43.0 2 222.16 12.07 210.09 9209-MSWLF-1984 MW-35 7/23/1998 35.91322 78.57052 Regolith 28.0 10.0-25.0 8.0-25.0 6.0-8.0 2 223.48 14.94 208.54 9209-MSWLF-1984 MW-36 11/25/2008 35.91491 78.57193 Regolith 40.0 -- 25.0-40.0 23.0-40.0 21.0-23.0 2 237.40 26.29 211.11 9209-MSWLF-1984 MW-36d 11/25/2008 35.91491 78.57193 Bedrock 55.0 0-45.0 50.0-55.0 48.0-55.0 45.0-48.0 2 237.68 26.52 211.16 Notes: 1. TOC - Top of Casing 2. bgs - Below Ground Surface 3. Latitude and Longitude Coordinates - World Geodetic System 1983 Smith Page 1 of 1 June 2021 Table 2 Summary of Calculated Groundwater Flow Velocities March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 �. 9209-MSWLF-1984 MW-5R 0.33 0.18 q25E-02 0.0233 4.28E-02 0.0233 4.27E-02 0.0232 4.25E-02 0.0234 4.29E-02 0.0232 1.16E-04 9209-MSWLF-1984 MW-6 10.58 0.13 0.0204 1.66E+00 0.0203 1.65E+00 0.0203 1.65E+00 0.0204 1.66E+00 0.0203 1.65E+00 3.73E-03 9209-MSWLF-1984 MW-7 1.15 0.18 0.0254 1.62E-01 0.0253 1.62E-01 0.0253 1.62E-01 0.0254 1.62E-01 0.0254 1.62E-01 4.06E-04 9209-MSWLF-1984 MW-8 3.61 0.18 0.0246 4.93E-01 0.0245 4.91E-01 0.0246 4.93E-01 0.0245 4.91E-01 0.0244 4.90E-01 1.27E-03 9209-MSWLF-1984 MW-9 1.22 0.30 0.0199 8.09E-02 0.0198 8.06E-02 0.0198 8.07E-02 0.0199 8.10E-02 0.0198 8.06E-02 4.30E-04 9209-MSWLF-1984 MW-10 0.509 0.05 0.0172 1.75E-01 0.0171 1.74E-01 0.0170 1.73E-01 0.0173 1.76E-01 0.0170 1.73E-01 1.80E-04 9209-MSWLF-1984 MW-11 5.66 0.13 0.0213 9.28E-01 0.0213 9.26E-01 0.0213 9.25E-01 0.0213 9.30E-01 0.0212 9.25E-01 2.00E-03 9209-MSWLF-1984 MW-22 0.07 0.18 0.0183 7.11E-03 0.0183 7.10E-03 0.0182 7.09E-03 0.0183 7.11E-03 0.0182 7.08E-03 2.47E-05 9209-MSWLF-1984 MW-23 3.59 0.30 0.0197 2.36E-01 0.0197 2.36E-01 0.0198 2.36E-01 0.0198 2.37E-01 0.0198 2.37E-01 1.27E-03 9209-MSWLF-1984 MW-24 0.34 0.30 0.0248 2.81E-02 0.0249 2.82E-02 0.0248 2.82E-02 0.0250 2.83E-02 0.0249 2.82E-02 1.20E-04 9209-MSWLF-1984 MW-36 17.56 0.30 0.0195 1.14E+00 0.0195 1.14E+00 0.0195 1.14E+00 0.0196 1.14E+00 0.0195 1.14E+00 6.19E-03 9209-MSWLF-1984 MW-36D 0.78 0.10 0.0194 1.51E-01 0.0193 1.51E-01 0.0194 1.51E-01 0.0194 1.51E-01 0.0193 1.51E-01 2.75E-04 Notes: 1. cm/s - centimeters per second 2. Hydraulic conductivity and effective porosity values are estimated from previously performed slug tests and grain size analyses. 3. The gradient and linear velocity values shown for MW-11 are based on the average of all the listed wells, with the exception of MW-36D. Smith Page 1 of 5 June 2021 Table 2 Summary of Calculated Groundwater Flow Velocities March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 �. �. 9209-MSWLF-1984 MW-511 0.33 0.18 0.0237 4.34E-02 0.0230 4.22E-02 0.0237 4.34E-02 0.0233 4.27E-02 0.0240 4.40E-02 1.16E-04 9209-MSWLF-1984 MW-6 10.58 0.13 0.0206 1.68E+00 0.0204 1.66E+00 0.0206 1.68E+00 0.0206 1.68E+00 0.0208 1.69E+00 3.73E-03 9209-MSWLF-1984 MW-7 1.15 0.18 0.0257 1.64E-01 0.0255 1.63E-01 0.0257 1.64E-01 0.0257 1.64E-01 0.0257 1.64E-01 4.06E-04 9209-MSWLF-1984 MW-8 3.61 0.18 0.0248 4.97E-01 0.0246 4.94E-01 0.0248 4.98E-01 0.0249 4.99E-01 0.0250 5.02E-01 1.27E-03 9209-MSWLF-1984 MW-9 1.22 0.30 0.0201 8.17E-02 0.0199 8.09E-02 0.0201 8.17E-02 0.0200 8.15E-02 0.0202 8.22E-02 4.30E-04 9209-MSWLF-1984 MW-10 0.509 0.05 0.0171 1.74E-01 0.0170 1.73E-01 0.0171 1.74E-01 0.0170 1.73E-01 0.0172 1.76E-01 1.80E-04 9209-MSWLF-1984 MW-11 5.66 0.13 0.0215 9.36E-01 0.0213 9.27E-01 0.0215 9.36E-01 0.0214 9.32E-01 0.0216 9.41E-01 2.00E-03 9209-MSWLF-1984 MW-22 0.07 0.18 0.0184 7.16E-03 0.0183 7.10E-03 0.0184 7.15E-03 0.0183 7.10E-03 0.0186 7.22E-03 2.47E-05 9209-MSWLF-1984 MW-23 3.59 0.30 0.0198 2.37E-01 0.0197 2.36E-01 0.0197 2.36E-01 0.0197 2.36E-01 0.0199 2.38E-01 1.27E-03 9209-MSWLF-1984 MW-24 0.34 0.30 0.0251 2.84E-02 0.0249 2.82E-02 0.0250 2.84E-02 0.0249 2.83E-02 0.0253 2.87E-02 1.20E-04 9209-MSWLF-1984 MW-36 17.56 0.30 0.0198 1.16E+00 0.0196 1.15E+00 0.0197 1.15E+00 0.0197 1.15E+00 0.0196 1.15E+00 6.19E-03 9209-MSWLF-1984 MW-36D 0.78 0.10 0.0196 1.53E-01 0.0195 1.52E-01 0.0196 1.53E-01 0.0196 1.53E-01 0.0197 1.54E-01 2.75E-04 Notes: 1. cm/s - centimeters per second 2. Hydraulic conductivity and effective porosity values are estimated from previously performed slug tests and grain size analyses. 3. The gradient and linear velocity values shown for MW-11 are based on the average of all the listed wells, with the exception of MW-36D. Smith Page 2 of 5 June 2021 Table 2 Summary of Calculated Groundwater Flow Velocities March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 Average Linear Velocity 9209-MSWLF-1984 MW-5R 0.33 0.18 0.0233 4.28E-02 0.0241 4.43E-02 0.0235 4.31E-02717 4.2E-02 0.0233 4.27E-02 1.16E-04 9209-MSWLF-1984 MW-6 10.58 0.13 0.0206 1.68E+00 0.0209 1.70E+00 0.0208 1.69E+00 1.68E+00 0.0204 1.66E+00 3.73E-03 9209-MSWLF-1984 MW-7 1.15 0.18 0.0257 1.64E-01 0.0261 1.66E-01 0.0256 1.64E-01 1.64E-01 0.0255 1.63E-01 4.06E-04 9209-MSWLF-1984 VW-8 3.61 0.18 0.0249 5.00E-01 0.0252 5.06E-01 0.0248 4.98E-01 0.0249 4.99E-01 0.0247 4.96E-01 1.27E-03 9209-MSWLF-1984 MW-9 1.22 0.30 0.0201 8.16E-02 0.0199 8.10E-02 0.0200 8.15E-02 0.0198 8.06E-02 0.0200 8.12E-02 4.30E-04 9209-MSWLF-1984 MW-10 0.509 0.05 0.0168 1.72E-01 0.0171 1.74E-01 0.0171 1.74E-01 0.0172 1.75E-01 0.0174 1.78E-01 1.80E-04 9209-MSWLF-1984 MW-11 5.66 0.13 0.0214 9.31E-01 0.0217 9.44E-01 0.0215 9.35E-01 0.0217 9.46E-01 0.0215 9.35E-01 2.00E-03 9209-MSWLF-1984 MW-22 0.07 0.18 0.0182 7.09E-03 0.0185 7.21E-03 0.0182 7.07E-03 0.0185 7.21E-03 0.0185 7.21E-03 2.47E-05 9209-MSWLF-1984 MW-23 3.59 0.30 0.0196 2.35E-01 0.0198 2.36E-01 0.0197 2.36E-01 0.0198 2.37E-01 0.0198 2.37E-01 1.27E-03 9209-MSWLF-1984 MW-24 0.34 0.30 0.0248 2.81E-02 0.0253 2.86E-02 0.0251 2.84E-02 0.0251 2.85E-02 0.0251 2.85E-02 1.20E-04 9209-MSWLF-1984 MW-36 17.56 0.30 0.0197 1.16E+00 0.0200 1.17E+00 0.0197 1.15E+00 0.0197 1.16E+00 0.0197 1.16E+00 6.19E-03 9209-MSWLF-1984 MW-36D 0.78 0.10 0.0196 1.53E-01 0.0199 1.55E-01 0.0195 1.52E-01 0.0196 1.53E-01 0.0196 1.53E-01 2.75E-04 Notes: 1. cm/s - centimeters per second 2. Hydraulic conductivity and effective porosity values are estimated from previously perfomed slug tests and grain size analyses. 3. The gradient and linear velocity values shown for MW-11 are based on the average of all the listed wells, with the exception of MW-36D. Smith Page 3 of 5 June 2021 Table 2 Summary of Calculated Groundwater Flow Velocities March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 9209-MSWLF-1984 MW-511 0.33 0.18 q4.36E-02 0.0233 4.27E-02 0.0229 4.20E-02 0.0238 1.16E-04 9209-MSWLF-1984 MW-6 10.58 0.13 0.0203 1.65E+00 0.0204 1.66E+00 0.0206 1.67E+00 3.73E-03 9209-MSWLF-1984 MW-7 1.15 0.18 0.0253 1.62E-01 0.0256 1.64E-01 0.0257 1.64E-01 4.06E-04 9209-MSWLF-1984 MW-8 3.61 0.18 0.0245 4.92E-01 0.0249 4.98E-01 0.0249 4.99E-01 1.27E-03 9209-MSWLF-1984 MW-9 1.22 0.30 0.0198 8.06E-02 0.0199 8.10E-02 0.0201 8.18E-02 4.30E-04 9209-MSWLF-1984 MW-10 0.509 0.05 0.0173 1.76E-01 0.0169 1.72E-01 0.0170 1.73E-01 1.80E-04 9209-MSWLF-1984 MW-11 5.66 0.13 0.0213 9.28E-01 0.0213 9.27E-01 0.0215 9.36E-01 2.00E-03 9209-MSWLF-1984 MW-22 0.07 0.18 0.0183 7.12E-03 0.0181 7.04E-03 0.0184 7.16E-03 2.47E-05 9209-MSWLF-1984 MW-23 3.59 0.30 0.0199 2.38E-01 0.0197 2.36E-01 0.0197 2.36E-01 1.27E-03 9209-MSWLF-1984 MW-24 0.34 0.30 0.0250 2.83E-02 0.0248 2.82E-02 0.0251 2.84E-02 1.20E-04 9209-MSWLF-1984 MW-36 17.56 0.30 0.0195 1.14E+00 0.0196 1.15E+00 0.0198 1.16E+00 6.19E-03 9209-MSWLF-1984 MW-36D 0.78 0.10 0.0194 1.51E-01 0.0195 1.52E-01 0.0043 3.35E-02 2.75E-04 Notes: 1. cm/s - centimeters per second 2. Hydraulic conductivity and effective porosity values are estimated from previously perfomed slug tests and grain size analyses. 3. The gradient and linear velocity values shown for MW-11 are based on the average of all the listed wells, with the exception of MW-36D. Smith Page 4 of 5 June 2021 Table 2 Summary of Calculated Groundwater Flow Velocities March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 Average 9209-MSWLF-1984 MW-5R 0.33 0.18 0.0233 4.27E-02 0.0236 4.33E-02 0.0236 4.33E-02 1.16E-04 9209-MSWLF-1984 MW-6 10.58 0.13 0.0205 1.66E+00 0.0206 1.68E+00 0.0206 1.68E+00 3.73E-03 9209-MSWLF-1984 MW-7 1.15 0.18 0.0256 1.63E-01 0.0257 1.64E-01 0.0257 1.64E-01 4.06E-04 9209-MSWLF-1984 MW-8 3.61 0.18 0.0248 4.98E-01 0.0250 5.01E-01 0.0250 5.01E-01 1.27E-03 9209-MSWLF-1984 MW-9 1.22 0.30 0.0200 8.13E-02 0.0202 8.20E-02 0.0202 8.20E-02 4.30E-04 9209-MSWLF-1984 MW-10 0.509 0.05 0.0169 1.72E-01 0.0171 1.74E-01 0.0171 1.74E-01 1.80E-04 9209-MSWLF-1984 MW-11 5.66 0.13 0.0214 9.30E-01 0.0215 9.37E-01 0.0215 9.37E-01 2.00E-03 9209-MSWLF-1984 MW-22 0.07 0.18 0.0183 7.11E-03 0.0184 7.17E-03 0.0184 7.16E-03 2.47E-05 9209-MSWLF-1984 MW-23 3.59 0.30 0.0197 2.35E-01 0.0198 2.37E-01 0.0198 2.37E-01 1.27E-03 9209-MSWLF-1984 MW-24 0.34 0.30 0.0249 2.83E-02 0.0251 2.85E-02 0.0251 2.85E-02 1.20E-04 9209-MSWLF-1984 MW-36 17.56 0.30 0.0196 1.15E+00 0.0198 1.16E+00 0.0198 1.16E+00 6.19E-03 9209-MSWLF-1984 MW-36D 0.78 0.10 0.0195 1.52E-01 0.0197 1.53E-01 -0.0461 -3.60E-01 2.75E-04 Notes: 1. cm/s - centimeters per second 2. Hydraulic conductivity and effective porosity values are estimated from previously perfomed slug tests and grain size analyses. 3. The gradient and linear velocity values shown for MW-11 are based on the average of all the listed wells, with the exception of MW-36D. Smith Page 5 of 5 June 2021 Table 3 Water Quality Parameters March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill Permit Number 9209-MSWLF-1984 Facility Permit Monitoring Number Well Code 9209-MSWLF-1984 MW-5R m 6.16 461.3 Water Quality Parameters 16.0 .. .. 26 0.13 ... -76.2 9209-MSWLF-1984 MW-6 5.43 346.1 15.6 56 1.75 117.4 9209-MSWLF-1984 MW-6d 5.54 131.2 17.0 9 0.89 155.4 9209-MSWLF-1984 MW-7 6.12 362.4 14.5 561 0.77 -12.0 9209-MSWLF-1984 MW-8 5.75 537.4 15.3 10 0.23 58.0 9209-MSWLF-1984 MW-8d 5.62 134.8 16.6 10 1.10 122.9 9209-MSWLF-1984 MW-9 6.01 763.0 19.1 10 0.19 -4.4 9209-MSWLF-1984 MW-10 5.11 75.7 18.3 8 0.19 167.3 9209-MSWLF-1984 MW-10d 5.72 142.2 18.4 9 5.88 136.8 9209-MSWLF-1984 MW-11 5.57 88.4 17.0 9 6.58 132.4 9209-MSWLF-1984 MW-11d 5.46 90.7 17.0 9 6.11 168.0 9209-MSWLF-1984 MW-22 NM NM NM 66 NM NM 9209-MSWLF-1984 MW-23 5.84 58.0 16.5 104 9.12 137.2 9209-MSWLF-1984 MW-23d 5.44 124.9 16.2 10 5.18 160.8 9209-MSWLF-1984 MW-24 NM NM NM 8 NM NM 9209-MSWLF-1984 MW-28 5.63 144.3 16.8 45 6.97 141.3 9209-MSWLF-1984 MW-28d 5.80 54.3 16.9 55 0.27 36.8 9209-MSWLF-1984 MW-29d 5.36 118.5 15.9 8 6.71 168.1 9209-MSWLF-1984 MW-30 NM NM NM 565 NM NM 9209-MSWLF-1984 MW-31 5.21 90.9 16.6 33 6.68 174.9 9209-MSWLF-1984 MW-31d 5.69 130.9 16.5 9 4.10 148.5 9209-MSWLF-1984 MW-32 4.78 83.6 14.4 23 1.70 167.5 9209-MSWLF-1984 TB-1a NM NM NM 33 NM NM 9209-MSWLF-1984 TB-1a deep 5.51 149.1 15.6 9 2.83 155.6 9209-MSWLF-1984 MW-33 5.77 133.7 15.9 8 1.32 53.8 9209-MSWLF-1984 MW-34 4.57 194.1 14.0 216 1.80 197.4 9209-MSWLF-1984 MW-34d 5.46 141.7 15.0 9 0.35 1 223.4 9209-MSWLF-1984 MW-35 5.27 162.0 15.2 4 0.81 63.7 9209-MSWLF-1984 MW-36 5.22 125.7 16.4 >1000 1.93 125.9 9209-MSWLF-1984 9209-MSWLF-1984 MW-36d SampleSurface Water Locations SW-2 5.81 6.80 229.3 95.9 16.8 16.3 252 7.93 0.52 9.66 60.0 106.0 9209-MSWLF-1984 SW-3 6.72 103.4 16.6 8.33 8.50 95.5 9209-MSWLF-1984 SW-7 6.98 91.5 16.5 4.67 11.20 130.2 9209-MSWLF-1984 SW-8 6.77 78.2 16.4 6.98 10.73 109.0 Notes: 1. Water quality measurements were collected on March 29-31, 2021. 2. NM - Not Measured. The monitoring wells went dry before water quality parameters were taken. 3. Turbidity readings were recorded at the time samples were collected. 4. µS/cm - Microsiemens per centimeter 5. mg/L - Milligrams per liter 6. ORP - Oxidation -Reduction Potential 7. NTUs - Nephelometric Turbidity Units 8. mVs - Millivolts 9. S.U. - Standard Units 10. DO - Dissolved Oxygen Smith Page 1 of 1 June 2021 Table 4a Detected Groundwater Constituents - Metals March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 3 " a`, £ E M v = v i _ £ E -0 a E _� c f0 i -0 O O N N fa E N m (OL V V Z VOf N L R m J V ~ � 1 700 4* 2 10 6** 1.000 15 1 100 20 20 0.2* 23** 1.000 MW-11 1-Nov-11 80.7.1 1.91 6.33,113 2.14JB 3.61J 19.6 MW-11 25-Apr-12 65.3.1 2.37J 3.23J 12.1 MW-11 23-Oct-12 80.6.1 1.42J 3.66J 5.32J 19.7 MW-11 17-Apr-13 901 0.2J 2J 2J 81 11 11 91 20B MW-11 16-Oct-13 100 0.1J 0.2J 2J iJ 4J 0.5J 0.91 51 15B MW-11 16-Apr-14 170 0.5.1 0.2.1 4J 6J 18 3J 1 0.08.1 40 50B MW-11 12-Nov-14 901 0.2.1 0.2.1 2J 2J 81 11 11 0.05.1 71 24 MW-11 30-Apr-15 100 0.2J 2J 3J 10i 1J 2J 0.06.1 12J 27 MW-11 15-Oct-15 110 0.3.1 0.1J 1 3J 11 11 0.041 2J 0.05.1 13JB 27 MW-11 21-Apr-16 0.51 130 0.3.1 1 4J 16 2J 2J 0.1JB 18J 32 MW-11 1-Sep-16 90J 0.28.1 0.54.1 2.4.1 2.6J 8.1 1.1 1.6J 111 20 MW-11 20-Apr-17 61J 1. 2J 1.5J 11 MW-11 22-Sep-17 45J 2.4.1 1.8J 3.7J 6.3.1 MW-11 13-Apr-18 61J 2.3.1 2.OJ 0.27J 12 MW-11 25-Oct-18 71J 2.2.1 3.9J 0.50J 5.11 66 MW-11 (dissolved) 25-Oct-18 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-11 26-Feb-19 57J 2.0.1 1.4J 10 MW-11 25-Apr-19 120 0.30.1 3.8.1 3.3J 20 2.2J 1.8J 17J 28 MW-11 (dissolved) 25-Apr-19 NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-11 2-Jul-19 170 0.70 5.1 7.4 25 4.1 4.1 33 45B MW-11 (dissolved) 2-Jul-19 NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-11 7-Nov-19 59 2.1J 4.1 0.66J 0.48 5.6 25 MW-11 (dissolved) 7-Nov-19 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-11 22-Jan-20 87 0.27.1 3.7.1 2.1J 12 1.9 1.5J 3.3J 9.2 21 MW-11 (dissolved) 22-Jan-20 NA NA NA NA NA NA NA NA NA NA NA NA NA NA M W-11 9-Apr-20 55 2.3.1 7.3.1 M W-11 15-Oct-20 55 1.5.1 10 MW-11 31-Mar-211 1 52 1 1 2.3.1 1 1 1 1 1 2.6J 1 5.5.1 MW-11d 2-Nov-11 45.5.1 2.18.1 4.14JB 2.45J 5.86J MW-11d 26-Apr-12 0.247.1 44.2.1 3.04.1 9.68.113 3.31J 2.05J 4.62J MW-11d 24-Oct-12 43.7.1 0.375.1 2.40.1 2.53J 5.10J MW-11d 18-Apr-13 0.4.1 50J 0.1J 2.113 0.2.1 11 0.6J 4.113 MW-11d 17-Oct-13 0.6J 0.61 50J 0.3.1 11 0.2J 11 0.02J 0.6J 2J 2.113 MW-11d 17-Apr-14 300 2.1 0.2.1 15 13 56 11 91 0.2J 99 88 MW-11d 13-Nov-14 150 0.7.1 0.1J 5J 4J 18 4J 1 0.07.1 37 35 MW-11d 29-Apr-15 0.6J 0.51 60J 0.1J 0.1J 2J 0.6J 1 0.6J 0.91 51 8.1 MW-11d 15-Oct-15 0.4.1 901 0.3.1 0.1J 1 2J 91 2J 0.05.1 2J 14JB 16 MW-11d 21-Apr-16 0.3.1 60J 2J 0.3.1 4J 0.5J 2J 12 MW-11d 1-Sep-16 0.4313.1 45J 0.076.1 1.2.1 2.1J 0.25J 0.75J 2.7J 9.2JB MW-11d 20-Apr-17 48J 2.2.1 2.2J 2.2J 5.0.1 MW-11d 22-Sep-17 45J 2.8.1 1.6J 3.3J 5.1J MW-11d 12-Apr-18 43J 5.8.1 2.8J 4.4.1 MW-11d 23-Oct-18 46J 25 13J 4.2.1 MW-11d 25-Feb-19 46J 7.OJ 3.4J 3.6.1 MW-11d (dup) 25-Feb-19 45J 9.9.1 4.9J 4.0.1 MW-11d 25-Apr-19 46J 5.OJ 2.2J 2.8.1 MW-11d 2-Jul-19 90 0.42 4.1J 2.5.1 12 1.8 2.4J 17 18B MW-11d (dissolved) 2-Jul-19 NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-11d 5-Nov-19 43 2.3.1 2.6J 0.29J 1.91 13B MW-11d (dup) 5-Nov-19 44 2.5.1 2.1J 0.26J 1.8J 11B MW-11d 21-Jan-20 0.65.1 46 2.8.1 2.1J 0.29J 8.4.1 MW-11d (dup) 21-Jan-20 0.86.1 48 3.4.1 2.1J 0.37J 9.5.1 MW-11d 8-Apr-20 44 0.18.1 5.3 1.1 2.8J 9.9.1 MW-11d 13-Oct-20 0.84.1 45 0.37.1 3.OJ 12 MW-11d 31-Mar-21 0.66J 46 0.40J 3.213J 4.6J 0.25J 1.4J 10 Smith Page 1 of 23 June 2021 Table 4a Detected Groundwater Constituents - Metals March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 MW-5R 31-Oct-11 123 3.28J 2.17J 5.83JB 1.13J 0.152J 8.33J MW-5R 24-Apr-12 0.411J 97.3J 2.79J 2.47J 0.170J 4.28J MW-5R 22-Oct-12 99.3J 1.82J 3.61J 0.114J 23.9 MW-5R 17-Apr-13 80J 0.08J 2J 0.3J 1 0.11 5JB MW-5R 16-Oct-13 90J 0.05J 1J 0.5J 0.4J 1 0.11 5JB MW-5R 16-Apr-14 80J 0.3J 0.3J 0.2J 0.5J iJ 0.2J 2J 5JB MW-5R 12-Nov-14 80J 2J 0.2J 2J 0.3J 6JB MW-5R 30-Apr-15 70J 0.11 0.8J 0.1J 11 0.11 4J MW-5R 15-Oct-15 110 0.2J 7J 0.8J 2J 0.6J 0.04J 4J 0.11 6J MW-5R 21-Apr-16 60J 0.07J 1J 0.2J 0.4J 11 0.UB 2J MW-5R 14-Sep-16 79J 0.063J 1.7J 0.45JB 0.046JB 2.4J 0.080J 1.0 5.3JB MW-5R 20-Apr-17 71J 1.51 MW-5R 20-Sep-17 430 13 1.7J 1.4J 5.8J MW-5R 11-Apr-18 76J 1.41 1.51 2.6J MW-5R 24-Oct-18 84J 2.1J 3.3J MW-5R 22-Apr-19 68J 0.23J MW-5R 6-Nov-19 130 2.2J 2.1 5.7 15 MW-5R 9-Apr-20 300 0.20J 0.13J 3.4J 290 2.9J 0.52J 100 0.51 4.1 51 MW-5R (dissolved) 9-Apr-20 NA NA NA NA NA NA 390 NA NA NA 140 NA NA 0.32J NA MW-5R 15-Oct-20 1.3J 170 0.43 0.23J 18 93 8.3 3.4 18 1.1 0.18J 16 22 MW-5R (dissolved) 15-Oct-20 NA NA NA NA NA 91 NA NA NA NA NA NA NA NA NA MW-5R 31-Mar-21 64 0.15J 4.9J 75 1.5J 0.52J 1 12 2.7J I MW-6 1-Nov-11 0.229J 3.98J 454 6.35J 65.7 4.04JB 18.2JB 2.55J 4.11J 5.36J MW-6 24-Apr-12 0.244J 182 3.49J 54.9 8.45J 2.18J 0.134J 117 MW-6 22-Oct-12 258 0.148J 1.59J 80.4 15.1J MW-6 17-Apr-13 100J 0.05J 1.6 35 4J 0.17J 6J 0.3J 91B MW-6 16-Oct-13 90J 0.04J 0.3J 34 2J 0.02J 5J 21 0.2J 3J 51B MW-6 (dup) 16-Oct-13 901 0.2J 0.6J 35 2J 0.04J 6J 21 0.2J 3J MW-6 16-Apr-14 0.2J 60J 0.10J 0.8J 11 18 1 0.21 4J 0.3J 2J 81B MW-6 (dup) 16-Apr-14 60J 0.07J 0.7J 11 18 2J 0.21 4J 0.2J 3J 81B MW-6 12-Nov-14 0.8J 310 49 11 0.02J 15J 21 0.11 21B MW-6 30-Apr-15 70J 0.06J 0.1J 25 11 0.08J 4J 0.11 3J MW-6 14-Oct-15 230 0.2J 32 4J 0.03J 13J 21 0.3J MW-6 20-Apr-16 70J 0.04J 8J 0.5J 0.03J 3J iJ 0.081 MW-6 (dup) 20-Apr-16 70J 0.3J 7J 0.6J 0.03J 3J 11 0.071 MW-6 14-Sep-16 0.19JB 0.29J 210 0.13J 19 2.1JB 0.032JB 9.1 1.1J 0.0841 1.2J 6.01E MW-6 20-Apr-17 120 2.5J 8.3J 0.98J 0.40 4.2J MW-6 (dup) 20-Apr-17 130 2.6J 8.2J 1.0J 0.41 4.8J 21 MW-6 21-Sep-17 160 5.3J 2.2J 7.6J MW-6 12-Apr-18 130 0.14J 7.9J 4.6J MW-6 24-Oct-18 240 0.13J 1.3J 18 1.5J 6.9J MW-6 22-Apr-19 120 0.17J 0.13J 19 0.17J 4.5J MW-6 7-Nov-19 270 0.18J 67 1.6J 0.16BJ 18 2.5J 0.28J 6.4J MW-6 (dissolved) 7-Nov-19 NA NA NA NA NA NA 77 NA NA NA NA NA NA 0.32J NA NA MW-6 7-Apr-20 130 0.49 0.25J 8 20 5.5 1.6 0.19J 6.4 5.2 8.6J MW-6 15-Oct-20 160 0.14J 33 8.5 0.20J 2.6J MW-6 31-Mar-21 94 0.321 0.17J 3.81 23 2.1 0.88J 0.19J 3.8J 3.8J 4.4J MW-6 (dissolved) 31-Mar-21 NA NA NA NA NA NA 25 NA NA NA NA NA NA NA NA NA Smith Page 2 of 23 June 2021 Table 4a Detected Groundwater Constituents - Metals March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 MW-6d 2-Nov-11 2.63J 100 5.42.1 1.26.1 6.46113 4.68.1 3.98J 13.1 MW-6d 26-Apr-12 1.59J 72J 5.68.1 7.2416 2.37J 2.61J 4J 6.97J MW-6d (dup) 26-Apr-12 1.22J 66J 5.53.1 6.4516 2.10J 2.20J 3.78J 5.88J MW-6d 23-Oct-12 1.21J 2.841 71.1.1 0.407J 4.83.1 2.81 2.11J 3.59J 6.02J MW-6d 18-Apr-13 3.1J 801 0.1J 0.5.1 4J 0.91 1 0.4J 2J 8.113 MW-6d (dup) 18-Apr-13 2.81 70J 0.09J 0.4.1 4J 0.8J 1 0.4J 2J 6.113 MW-6d 17-Oct-13 6.9 801 0.1J 0.5.1 4J 1.1 4J 0.6J 0.03J 3J 1 7.113 MW-6d 17-Apr-14 1.21 60J 0.1J 0.1J 4J 1.0.1 2J 0.1 2J 6J 7.113 MW-6d 12-Nov-14 1.21 60J 0.1J 0.2.1 1 1J 2J 0.1 2J 4.113 MW-6d 30-Apr-15 1.71 0.61 50J 0.08J 0.1J 4J 0.9.1 2J 0.2J 2J 1 4.1 MW-6d (dup) 30-Apr-15 2.1J 80J 0.05J 0.2.1 4J 0.9.1 2J 0.1 0.05J 2J 1 6.113 MW-6d 15-Oct-15 1.1J 60J 0.1J 0.2J 4J 0.6J 2J 0.4J 0.04J 1 2.113 6.1 MW-6d 20-Apr-16 0.4J 50J 0.07J 0.1J 4J 0.6J 2J 1 4.1 MW-6d 12-Sep-16 1.0J 65J 0.21.1 4.4.1 0.85.1 6.6JB 1.7J 2.4J 0.34J 4.7J 15 MW-6d 20-Apr-17 51J 2.6.1 2.4J 1.6J 2.6J 9.1J MW-6d 22-Sep-17 0.66J 33J 4.2.1 3.1J 4.1J 6.3.1 MW-6d 13-Apr-18 1.0J 41J 3.8.1 1.4J 7.6.1 MW-6d 24-Oct-18 31J 7.9.1 2.4J 3.5J MW-6d 23-Apr-19 57J 0.15J 8.2.1 5.1 0.51J 2.9J 8.2J 6.5.1 MW-6d 6-Nov-19 0.55J 70 0.81 4.4.1 3.5J 0.39J 2.2J 3.5J 16 MW-6d 7-Apr-20 0.75J 69 0.36J 4.4.1 2.4J 0.39J 1.91 9.5.1 MW-6d 13-Oct-20 2.8 130 0.25J 3.4.1 1.5J 0.31 1.7J 19 MW-6d 31-Mar-21 0.781 85 0.171 4.2J 2.1J 0.25J 1.6J 3.0J 8.51 MW-7 2-Nov-11 67.11 0.381 14.9 31.6 21.213 13.4J 1.17J 3.271 9.74J 44.8 MW-7 26-Apr-12 50.31 0.8051 13.3 27.1 10.713 4.04J 10.91 3.631 7.24J 13.9 MW-7 22-Oct-12 80.71 29.6 30.8 37.4 6.69J 11.5J 2.021 0.1521 24.2J 24.1 MW-7 16-Apr-13 80J 0.5J 0.6J 35 27 61 91 0.181 13J 21 0.2J 24J 25B MW-7 16-Oct-13 60J 0.1J 0.6J 5J 37 11 11 0.041 12J 3J 12J 11B MW-7 16-Apr-14 50J 0.21 1.1 101 46 19 1 0.041 17J 31 0.091 23J 40B MW-7 11-Nov-14 0.51 70J 0.41 0.71 23 26 45 7J 0.28 13J 21 0.2J 5J 22 MW-7 30-Apr-15 60J 0.11 0.91 5J 48 11 2J 0.041 17J 0.081 33 MW-7 14-Oct-15 40J 0.11 0.41 7J 30 10 2J 0.021 10J 11 0.051 31 MW-7 20-Apr-16 40J 0.061 1.0 2J 52 7J 2J 0.031 17J 21 11 MW-7 13-Sep-16 0.241 44J 1.6 1.41 41 5.5113 1.1J 12J 4.0J 13 MW-7 18-Apr-17 34J 0.13J 0.831 6.11 31 30 16 0.0371 9.2J 8.1J 7.4.1 MW-7 18-Sep-17 0.521 27J 23 1.11 6.8J MW-7 11-Apr-18 41J 1.5 3.71 32 7.6J 1.11 111 5.7J 29 MW-7 (dissolved) 11-Apr-18 NA NA NA NA NA NA 31 NA NA NA NA NA NA NA NA MW-7 25-Oct-18 52J 1.3 3.31 34 22 8.6J 10J 8.6J 30 MW-7 (dissolved) 25-Oct-18 NA NA NA NA NA NA 37 NA NA NA NA NA NA NA NA MW-7 24-Apr-19 35J 17 6.4J 12 MW-7 4-Nov-19 46 0.381 0.84 13 27 38 10 0.17BJ 8.9 0.261 0.181 26 24B MW-7 8-Apr-20 48 0.451 3.8J 41 9.8 2.8 11 5.7 41 MW-7 (dissolved) 8-Apr-20 NA NA NA NA NA NA 44 NA NA NA NA NA NA NA NA MW-7 14-Oct-20 40 0.30J 35 1.4J 9.1 9.1J MW-7 31-Mar-21 46 0.37J 3.21 47 10 2.5 13 8.1 17 MW-7 (dissolved) 31-Mar-21 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA Smith Page 3 of 23 June 2021 Table 4a Detected Groundwater Constituents - Metals March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 MW-8 31-Oct-11 56.51 7.421 4.53,113 4.95,113 5.18J 7.32J MW-8 24-Apr-12 0.937J 41.31 1.211 3.19J 1.83J 515 MW-8 22-Oct-12 41.81 0.1461 0.404J 1.201 2.76J 1.97J MW-8 17-Apr-13 0.8J 50J 0.081 2J 11 0.03J 4J 916 MW-8 16-Oct-13 50J 0.11 0.2J 2J 21 4J MW-8 16-Apr-14 50J 0.07J 11 11 5J 51 107 MW-8 12-Nov-14 50J 0.6.1 0.4.1 5J 5.113 MW-8 30-Apr-15 80J 0.1J 0.1J 4J 2.1 2J 0.2J 7J 14 MW-8 15-Oct-15 80J 0.08J 0.1J 2J 2.1 0.1 0.04J 6J 6.1 MW-8 21-Apr-16 70J 0.8.1 2.1 0.02J 6J 0.05JB 6.1 MW-8 14-Sep-16 65J 0.13.1 1.9.1 0.27.113 6.6J 2.9J 8.5JB MW-8 20-Apr-17 61J 4.9J 1.81 4.7.1 MW-8 18-Sep-17 73J 0.14J 0.85.1 4.6J 3.OJ 5.7.1 M W-8 12-Apr-18 65J 4.2.1 5.2J 4.5.1 MW-8 24-Oct-18 71J 2.7.1 5.OJ 7.0.1 MW-8 22-Apr-19 110 1.3.1 9.4J 0.111 8.2J 2.6J 120 MW-8 (dup) 22-Apr-19 110 9.5J 8.11 2.5J 5.6.1 MW-8 7-Nov-19 48 6.4 1.6.1 2.5J 0.32B 5.4 6.0 12 MW-8 (dissolved) 7-Nov-19 NA NA NA NA NA NA 1.5.1 NA NA NA NA NA NA NA 2.6J NA MW-8 9-Apr-20 43 2.5.1 4.8J 8.4.1 M W-8 15-Oct-20 81 6.6 8.1 5.8.1 MW-8 31-Mar-21 1 1 63 1 0.63 1 13 2.3.1 1 3.1 0.51J 1 1 6.4 1 1 8.9 1 11 MW-8d 2-Nov-11 0.724J 25.0.1 1.05 5.02J 5.02J6 2.00J 4.22J 7.28J MW-8d 26-Apr-12 1.63J 34.5.1 11B 2.82J 4.15J 7.52J MW-8d 24-Oct-12 1.59J 30.6J 0.483.1 5.46.1 3.21J 4.79J 9.99J MW-8d 18-Apr-13 0.6J 20J 4J 0.3.1 11 0.2J 11 0.06J 2.113 MW-8d 17-Oct-13 40J 0.2.1 0.3.1 6J 1.1 6J 11 0.03J 2J 7J MW-8d 17-Apr-14 0.9J 20J 0.1J 4J 0.4.1 2J 0.1 0.81 7J 5.113 MW-8d 12-Nov-14 1.OJ 20J 4J 0.3.1 2J 0.1 0.91 2.113 MW-8d 30-Apr-15 2.5J 0.61 20J 0.1J 1 0.4.1 11 0.4J iJ 2J 4.1 MW-8d 15-Oct-15 0.2J 20J 1 0.06J 0.05J 0.5J 1.113 MW-8d 21-Apr-16 20J 3J 0.5J MW-8d 14-Sep-16 16J 1.7.1 0.60J6 0.047JB 0.72J 4.8J 2.0.113 MW-8d 20-Apr-17 191 2.6.1 4.1 4.OJ 3.1J MW-8d 18-Sep-17 16J 2.9.1 3.1 MW-8d (dup) 18-Sep-17 17J 3.2.1 2.8J MW-8d 12-Apr-18 17J 3.5.1 MW-8d 23-Oct-18 18J 6.5.1 2.2J 4.4J MW-8d (dup) 23-Oct-18 17J 6.3.1 2.OJ 4.5J MW-8d 23-Apr-19 17J 4.OJ 3.9J MW-8d 6-Nov-19 21 0.22J 3.9.1 3.2J 1.4J 3.9J 14 MW-8d 8-Apr-20 0.50J 28 0.25J 4.5.1 0.45J 5.8.1 MW-8d 13-Oct-20 1.3J 25 0.55 3.7.1 1.7J 0.25J 3.9J 15 MW-8d 31-Mar-21 1.51 35 0.21J 4.8.1 3.2J 1.5 1.1 6.1 8.4.1 MW-8d (dup) 31-Mar-21 2.6 35 0.23J 6.9 4.7J 1.8 2.5J 8.4 12 Smith Page 4 of 23 June 2021 Table 4a Detected Groundwater Constituents - Metals March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 MW-9 1-Nov-11 209 0.425J 14.9 6.79J 8.83,113 6.37J 4.11,113 0.982J 4.52.1 0.164.1 6.88J 69.2 MW-9 (dup) 1-Nov-11 191 0.256J 10.4 5.81J 5.32,113 3.99J 3.08J6 0.874J 3.66.1 0.127.1 3.26J 50.1 MW-9 25-Apr-12 176 0.220J 5.68J 4.81J 2.72.1 13.5 MW-9 23-Oct-12 5.171 210 0.711J 4.13 19.7 6.96J 17.1 27.2 3.41J 7.49J 0.521J 30.2 141 MW-9 17-Apr-13 160 0.3JB 2 1 4J 4J 4J 4J 0.3J 8J 27B MW-9 16-Oct-13 120 0.2J 1.1 2J 0.4.1 2J iJ 2J 0.2J 6J 16B MW-9 16-Apr-14 130 0.4J 1.3 4J 0.8J 5J 4J 1 0.3J 16J 36B MW-9 12-Nov-14 120 0.3J 0.4.1 4J 0.6J 4J 3J 2J OX 17 MW-9 (dup) 12-Nov-14 140 0.5J 0.4.1 6J 1.1 6J 6J 2J 0.3J 4J 28 MW-9 29-Apr-15 0.71 901 0.1J 0.3.1 2J 0.1J 11 0.8J 0.8J OX 1 8.1 MW-9 15-Oct-15 160 0.7J 0.2J 91 1.1 6J 7J 0.07J iJ 0.3J 11JB 31 MW-9 20-Apr-16 150 0.2J 2J 0.2.1 11 0.7J 0.91 0.11 3.1 MW-9 13-Sep-16 100 0.15J 0.12.1 1.7.1 1.3JB 1.OJ 1.2J 0.16.1 11JB 9.4.1 MW-9 19-Apr-17 130 2.1J 1.OJ 0.52J 7.4J 4.6.1 MW-9 21-Sep-17 160 1.4 0.37J 13 1.9.1 11 15 2.1J 0.40J 34 49 MW-9 (dissolved) 21-Sep-17 NA NA NA NA NA NA NA NA NA NA NA 11J NA MW-9 11-Apr-18 130 0.16J 3.2.1 0.61J 3.OJ 0.20J 5.5J 4.5.1 MW-9 (dissolved) 11-Apr-18 NA NA NA NA NA NA NA NA NA NA NA NA NA 5.6J NA MW-9 25-Oct-18 89J 2.1J 0.15.1 111 MW-9 25-Apr-19 150 1.1 2.3.1 0.39J 2.4J 7.0 6.9.1 MW-9 7-Nov-19 230 0.17J 1.5 3.8.1 11 2.1 0.22 4.7J 1.7J 0.22J 10 57 MW-9 (dissolved) 7-Nov-19 NA NA NA NA NA NA NA NA NA NA NA NA NA 0.21J 6.7 NA MW-9 9-Apr-20 270 2.2 11 2.8J 0.44J 6.4 0.21J 3.9J 30 MW-9 15-Oct-20 0.96J 320 1.3 2.1 0.58J 5.5 0.21J 9.9 14 MW-9 31-Mar-21 1 1 390 0.15J 1 2.7 1 2.4J 1.4.1 1 11 1.4 1 1 8.9 1 0.161 1 9.3 1 25 MW-10 31-Oct-11 28.1.1 1.72.1 1.61.1 3.56.113 3.00J 1.941 12.8 MW-10 25-Apr-12 34.7.1 0.320J 0.438.1 1.79.1 2.04J 4.81J 2.64J 0.538 2.25J 21.7 MW-10 23-Oct-12 31.1.1 0.302J 0.965.1 2.07J 2.51J 2.57J 0.910 2.07J 16.5 MW-10 17-Apr-13 30J 0.3.113 0.4J 0.4.1 2.1 2.113 11 0.43 1 0.061 14B MW-10 16-Oct-13 30J 0.3.1 0.2J 0.4.1 2.1 2J 11 0.29 1 0.051 4J 916 MW-10 16-Apr-14 30J 0.3.1 0.2J 2J 1J 0.5J 0.05J 3J 4J 38B MW-10 12-Nov-14 30J 0.3.1 2.1 0.03J 1 916 MW-10 29-Apr-15 0.2J 40J 0.3.1 0.1J 3.1 2J 11 0.10J 5J 0.051 10 MW-10 14-Oct-15 30J 0.3.1 0.2J 2J 0.8J 0.4J 0.08J 1 27 MW-10 20-Apr-16 30J 0.3.1 0.1J 4.1 0.6J 0.1 0.03J 5J 11 0.051 4.1 MW-10 13-Sep-16 0.471 31J 0.36.1 0.19.1 3.8.1 2.OJB 1.2J 0.14J 4.8J 3.6J 280 MW-10 19-Apr-17 27J 0.32.1 2.9.1 0.91 0.38J 0.064J 3.4J 17 MW-10 22-Sep-17 17J 0.18.1 1.3.1 2.2J 0.30J 2.1 2.1J 8.9.1 MW-10 11-Apr-18 20J 0.32.1 0.87.1 1.9.1 2.4.1 1.1 0.55J 0.27 2.5J 51 MW-10 25-Oct-18 24J 0.16.1 0.72.1 2.3.1 0.57J 0.39 2.7J 7.4J 77 MW-10 (dissolved) 25-Oct-18 NA NA NA NA NA NA 2.6.1 NA NA NA NA NA NA NA NA MW-10 25-Apr-19 25J 1.7.1 2.7.1 0.45J 5.1J 2.5.1 MW-10 7-Nov-19 20 0.24J 2.6.1 2.6J 0.50J 0.12.1 4.1 2.5J 66 MW-10 (dissolved) 7-Nov-19 NA NA NA NA NA NA 2.21 NA NA NA NA NA NA NA NA NA MW-10 7-Apr-20 23 0.171 1.31 2.71 0.61J 0.14J 4.OJ 15 MW-10 15-Oct-20 4.8 12 0.491 1.41 1.5J 0.32J 2.4J 33 MW-10 31-Mar-21 16 0.161 1.1 56 5.8 0.47J 0.097J 4.OJ 4.5J 31 Smith Page 5 of 23 June 2021 Table 4a Detected Groundwater Constituents - Metals March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 MW-10d 2-Nov-11 3.81J 2.10J 3.18JB 4.14J MW-10d 26-Apr-12 0.232J 4.36J 3.50J 3.47JB 4.57J MW-10d 24-Oct-12 3.11J MW-10d 18-Apr-13 4JB 1JB 0.07J 0.7J 1J MW-10d 16-Oct-13 0.3J 3JB 0.2J 1J 0.05J 0.7J 0.6J MW-10d 17-Apr-14 2J 0.4J 0.6J 4J 3JB MW-10d 12-Nov-14 3J 0.5J 0.04J 0.4J MW-10d 30-Apr-15 0.81 0.51 3J 0.3J 0.3J 0.05J 0.6J 4J MW-10d 15-Oct-15 0.5J 51 0.07J 0.8J 0.08J 11 0.2J 0.071 0.6J 5J MW-10d 21-Apr-16 0.3J 51 0.2J 2J iJ 2J 6J MW-10d 14-Sep-16 2.5J 0.67JB 0.15J 3.1 5.5JB MW-10d 19-Apr-17 2.5J 0.14J 0.70J MW-10d 18-Sep-17 4.1J 0.35J 1.4J 3.1J 0.32J 6.9J MW-10d 11-Apr-18 0.60J 3.7J 0.60J 1.8J 2.1J 0.34J 14 MW-10d 25-Oct-18 2.5J MW-10d 25-Apr-19 2.8J 3.0J MW-10d 5-Nov-19 3.7J 0.14J 1.1 0.34J 0.098BJ 6.2BJ MW-10d 9-Apr-20 2.8J 2.7J MW-10d 14-Oct-20 2.3J 3.41 MW-10d 31-Mar-21 1.4J 4.5J 0.27J 3.6J 2.0J 0.29J 3.4J 10 MW-22 1-Nov-11 41.2J 7.96 4.25J 46.7 5.24JB 17.2JB 2.87J 3.22J 43.9 MW-22 25-Apr-12 61.5J 0.224J 4.78 4.77J 63.8 14J 2.56J 0.162J 33.1 18.4 MW-22 23-Oct-12 34.7J 8.27 2.28J 44.7 16.8J 4.02J 19.2 MW-22 17-Apr-13 70J 0.11 4 0.91 76 1JB 0.7J 15J 0.06J 12B MW-22 16-Oct-13 50J 0.11 3.5 11 25 11 11 101 1 8JB MW-22 16-Apr-14 50J 0.11 2.5 0.91 43 11 11 14J 4J 14B MW-22 12-Nov-14 40J 0.11 2.5 3J 17 2J 2J 101 91 MW-22 30-Apr-15 50J 1.5 0.6J 31 0.7J 0.6J 101 91 MW-22 15-Oct-15 80J 0.7J 3.4 91 29 5J 91 0.05J 13J 4J 0.2J 14JB 56 MW-22 20-Apr-16 40J 0.07J 1.3 18 0.5J 0.3J 7J 61 MW-22 13-Sep-16 82J 0.82J 3.1 12 38 6.9JB 11 14J 3.11 0.20J 18J 47 MW-22 19-Apr-17 45J 0.26J 2.8 1.91 18 2.6J 1.6J 6.5J 0.93J 6.4J 13 MW-22 18-Sep-17 M W-22 13-Apr-18 MW-22 23-Oct-18 ° Not Sampled MW-22 23-Apr-19 MW-22 4-Nov-19 MW-22 8-Apr-20 MW-22 14-Oct-20 48 1 0.16J 1.5 2.3J 40 1.7J 1 3.2 11 I I I 3 6J I 14 MW-22 31-Mar-21 27 0.91 18 0.27J 4.8J Smith Page 6 of 23 June 2021 Table 4a Detected Groundwater Constituents - Metals March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 MW-23 2-Nov-11 43.51 5.931 11.06 2.79J 4.01J 9.101 14.8 MW-23 26-Apr-12 42.71 6.681 1.63J 10.46 7.07J 4.20J 12.5J 17.5 MW-23 24-Oct-12 38.91 5.761 1.83J 8.02J 4.12J 3.92J 13.1 18.5 MW-23 18-Apr-13 0.2J 240 1.8 0.1J 30 15 56 30 0.06J 28J 11 106 147 MW-23 16-Oct-13 30J 0.21 0.1J 1 0.7J 4J 2J 0.02J 2J 5J 616 MW-23 16-Apr-14 50J 0.3.1 0.2J 7J 2.1 10 5J 4J 0.1J 16J 25B MW-23 12-Nov-14 50J 0.4.1 7J 2.1 12 6J 0.02J 5J 0.1J 12J 19 MW-23 30-Apr-15 0.4J 50J 0.3.1 7J 2J 13 6J 0.03J 6J 0.1J 15J 26 MW-23 15-Oct-15 110 1.1 20 7J 34 18 0.06J 16J 0.5J 39 69 MW-23 (dup) 15-Oct-15 170 1.6 32 11 51 30 0.12J 25J 0.81 60 112 MW-23 20-Apr-16 40J 0.3.1 5J 1.1 91 5J 4J 0.1J 91 21 MW-23 13-Sep-16 54J 0.59.1 0.083J 8.9.1 3.3.1 15B 7.7J 6.9J 0.22J 23J 39 MW-23 19-Apr-17 26J 0.19.1 3.3.1 4.5J 2.1J 2.4J 6.5J 7.2.1 MW-23 20-Sep-17 110 1.5 0.14J 19 6.6J 33 17 16J 0.48J 59 67 MW-23 (dissolved) 20-Sep-17 NA NA NA NA NA NA NA NA NA NA 3.1 NA MW-23 11-Apr-18 85J 0.86.1 0.22.1 12 4.4.1 21 11 14J 0.28J 30 44 MW-23 (dissolved) 11-Apr-18 NA NA NA NA NA NA NA NA NA NA NA NA MW-23 25-Oct-18 51J 0.261 0.621 9.2.1 3.1J 12 5.6J 8.1 0.19J 21J 45 MW-23 (dissolved) 25-Oct-18 NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-23 25-Apr-19 42J 0.191 5.6.1 1.8.1 8.0J 4.6J 4.2J 13J 30 MW-23 (dissolved) 25-Apr-19 NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-23 5-Nov-19 39 0.351 6.0 1.7.1 10 5.3 4.1 0.23J 13 24B MW-23 (dissolved) 5-Nov-19 NA NA NA NA NA NA NA NA NA NA NA NA 0.20J NA MW-23 8-Apr-20 110 0.44 12 4.6.1 26 18 9.2 0.23J 28 39 MW-23 (dissolved) 8-Apr-20 NA NA NA NA NA 1.71 NA NA NA NA NA NA MW-23 14-Oct-20 19 1.91 1.8J 1.0 3.8J 2.8.1 MW-23 31-Mar-21 25 4.21 6.2 3.0 2.7J 9.1 12 MW-23d 1-Nov-11 0.7981 35.81 3.921 4.12113 3.75J 10.9 MW-23d 25-Apr-12 0.7541 35J 0.7461 4.031 16.813 3.32J 4.05J 6.65J MW-23d 23-Oct-12 0.552J 33.21 0.6441 4.731 4.38J 4.48J 8.66J MW-23d 18-Apr-13 2.6J 40J 1.5 3113 0.31 4J 0.4J 1J 12B MW-23d 17-Oct-13 1.7J 40J 0.051 0.71 2J 0.31 3J 0.3J 0.021 11 1 316 MW-23d 17-Apr-14 1.3J 30J 0.31 2J 0.31 2J 0.3J 1J 6J 816 MW-23d 13-Nov-14 1.1J 40J 0.21 2J 0.31 2J 0.3J 0.8J 2J 61 MW-23d 29-Apr-15 1.6J 40J 0.21 2J 0.31 2J 0.3J 0.91 2J 61 MW-23d 15-Oct-15 3.6J 40J 0.041 0.51 3J 0.41 4J 0.6J 0.051 11 2113 13 MW-23d 20-Apr-16 1.1J 40J 0.21 3J 0.31 2J 0.2J 4J 71 MW-23d 13-Sep-16 1.2J 37J 0.231 2.31 0.261 2.51B 0.48J 2.5J 6.1J 13 MW-23d (dup) 13-Sep-16 0.97J 36J 0.221 1.91 2.21B 0.36J 2.2J 5.7J 10 MW-23d 19-Apr-17 0.53J 34J 0.241 2.0J 4.9J 1.4J 3.7J 6.91 MW-23d 21-Sep-17 34J 2.71 3.8J 3.5J 5.81 MW-23d 10-Apr-18 38J 5.21 2.4J 0.32J 1.8J 2.6J 3.41 MW-23d (dup) 10-Apr-18 36J 4.81 2.3J 1.7J 3.11 MW-23d 23-Oct-18 36J 14 7.0J 4.0J MW-23d 23-Apr-19 41J 2.21 3.9J MW-23d 4-Nov-19 1.7J 34 0.91 2.21 4.1J 0.35J 0.096BJ 1.3J 3.8J 21B MW-23d 8-Apr-20 1.11 33 0.80 3.51 3.5J 0.47J 1.5J 29 MW-23d 13-Oct-20 7.3 34 0.93 2.11 3.2J 0.51J 1.5J 3.7J 29 MW-23d (dup) 13-Oct-20 7.6 35 0.92 2.41 3.4J 0.64J 1.6J 3.6J 25 MW-23d 31-Mar-21 0.61J 37 0.211 9.8 2.9J 0.26J 1.3J 3.7J 14 Smith Page 7 of 23 June 2021 Table 4a Detected Groundwater Constituents - Metals March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 MW-24 2-Nov-11 48.81 3.811 6.75,113 4.69J 2.11 6.26J 43.6 MW-24 26-Apr-12 57.61 0.2811 7.541 7.09J6 9.80J 3.35J 1.82J 0.190J 8.38J 58.7 MW-24 23-Oct-12 35.91 2.101 2.50J 4.01J 0.120J 5.34J 28.3 MW-24 17-Apr-13 120 1.41 0.1J 91 2J 11 17 0.24 5J 0.51 17J 128 MW-24 16-Oct-13 60J 0.61 0.1J 4J 0.91 5J 7J 0.091 2J 0.2J 8J 46 MW-24 16-Apr-14 120 1.1 6J 2.1 91 14 0.17J 4J 0.4J 22J 120 MW-24 12-Nov-14 130 1.5 8J 2.1 11 17 0.21 5J 0.6J 14J 117 MW-24 29-Apr-15 80J 0.81 4J 1.1 7J 91 0.12J 3J 0.3J 101 69 MW-24 14-Oct-15 240 2.5 0.2J 12 4.1 18 29 0.43 7J 0.91 34 182 MW-24 20-Apr-16 170 1.8 101 3.1 13 22 0.21 6J 0.7J 23J 140 MW-24 13-Sep-16 34J 0.371 0.086J 1.41 0.55J 2.3JB 3.6J 1.51 0.121 7.5J 31 MW-24 19-Apr-17 66J 0.771 3.81 0.98J 5.0J 7.9J 0.086J 2.5J 0.24J 9.1J 56 MW-24 20-Sep-17 51J 0.761 3.91 0.71J 4.6J 5.8J 2.4J 0.191 7.5J 47 MW-24 (dissolved) 20-Sep-17 NA NA NA NA NA NA NA NA NA NA NA NA NA 3.6J NA MW-24 11-Apr-18 62J 0.751 4.81 5.0J 7.1J 2.6J 0.22J 6.9J 49 MW-24 (dissolved) 11-Apr-18 NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-24 23-Oct-18 MW-24 24-Apr-19 (4) Not Sampled MW-24 4-Nov-19 MW-24 8-Apr-20 MW-24 14-Oct-20 22 1.51 0.77J 2.5J 5.1J MW-24 31-Mar-21 15 0.201 1.7.1 0.801 3.2J 7.61 MW-28 26-Apr-12 67.7.1 14.2 3.901 2.81113 5.18J 5.84J 0.229J 20.7J 69.8 MW-28 18-Apr-13 60J 0.3.1 10 31 11 11 4J 0.2J 10J 34B MW-28 17-Apr-14 170 1.5 41 14 51 7J 0.021 20J 1.0J 53 159 MW-28 30-Apr-15 80J 0.5.1 16 51 2J 2J 0.021 7J 0.4J 22J 62 MW-28 21-Apr-16 20J 4J 0.06J 91 MW-28 20-Apr-17 29J 0.18J 3.9.1 0.30J 1.3J 6.1J 11 MW-28 13-Apr-18 55J 0.41.1 11 2.7J 1.3J 5.11 0.161 15J 22 MW-28 (dissolved) 13-Apr-18 NA NA NA NA NA NA NA NA NA NA NA NA 2.6J NA MW-28 25-Apr-19 56J 0.17J 8.9.1 2.61 1.2J 4.4J 0.151 15J 37 MW-28 (dissolved) 25-Apr-19 NA NA NA NA NA NA NA NA NA NA NA NA NA 2.8J NA MW-28 8-Apr-20 76 0.31J 14 4.71 2.5 7.1 0.38J 24 54 MW-28 (dissolved) 8-Apr-20 NA NA NA NA NA 3.2J NA NA NA NA NA NA NA MW-28 31-Mar-21 32 0.16J 1 5.7 2.6J 1.1 1.91 1 8.4 29 MW-28d 26-Apr-12 1.46J 28.7.1 10.1 1.341 13.313 4.99J 9.42J 4.73J 106 MW-28d 18-Apr-13 0.1 9113 2113 0.11 0.91 0.91 416 MW-28d 17-Apr-14 0.41 11 6J 4J 0.41 3J 1.01 51 6J 10B MW-28d 30-Apr-15 0.21 101 2J 0.091 0.6J 0.91 71 MW-28d 21-Apr-16 91 2J 0.8J 91 91 MW-28d 20-Apr-17 8.1J 1.3.1 0.68J 3.1 5.91 MW-28d 13-Apr-18 5.8J 1.9.1 6.91 MW-28d 25-Apr-19 7.1J 2.0J 1.5J 1.5J 3.1 9.91 MW-28d (dissolved) 25-Apr-19 NA NA NA NA NA NA NA NA NA NA NA NA NA NA 2.5J NA MW-28d 8-Apr-20 7.3 2.6.1 1.3J 9.11 MW-28d 31-Mar-21 15 2.9.1 3.8J 1.2 6.3 6.7 15 Smith Page 8 of 23 June 2021 Table 4a Detected Groundwater Constituents - Metals March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 MW-29d 1-Nov-11 42.7J 6.46J 1.21J 12.41B 2.70J 4.25J 17.2 MW-29d 26-Apr-12 0.317J 41.5J 6.48J 8.73JB 3.94J 1.97J 3.72J 23.2 MW-29d 24-Oct-12 38.0J 4.87J 6.36J 2.48J 4.36J 7.64J MW-29d 18-Apr-13 40J 0.08J 4J 0.4J 5J 0.3J 11 0.051 3JB MW-29d 17-Oct-13 40J 0.11 4J 0.2J 3J 1J MW-29d 17-Apr-14 40J 0.08J 3J 0.2J 3J 0.8J 5J 25B MW-29d 13-Nov-14 40J 0.07J 3J 0.5J 4J 0.1 2J 2.1 MW-29d 29-Apr-15 0.2J 0.5J 40J 0.11 4J 0.3J 4J 0.1 11 13 MW-29d 15-Oct-15 0.2J 40J 0.11 4J 0.3J 4J 0.6J 0.04J 1J 8.1 MW-29d 21-Apr-16 0.6J 40J 4J 0.3J 5J 0.2J 11 6.1 MW-29d 12-Sep-16 0.38J 39J 2.7J 3.1JB 0.25J 0.901 4.8J 22 MW-29d 19-Apr-17 36J 2.7J 1.91 2.1 13 MW-29d 22-Sep-17 35J 3.9J 2.8J 5.9J MW-29d 12-Apr-18 34J 3.7J 1.1 5.4J MW-29d 24-Oct-18 34J 3.2J 3.1 2.7.1 MW-29d 25-Apr-19 38J 3.3J MW-29d 5-Nov-19 33 3.4J 3.9J 0.36J 0.092BJI 2.0J 39B MW-29d 6-Apr-20 1.4J 43 0.24J 11 19 2.5 4.1J 3.8J 30 MW-29d 14-Oct-20 1.3J 37 0.13J 3.6J 2.5J 0.381 45 MW-29d 31-Mar-21 0.64J 45 1 1 5.6 6.9 0.731 2.0 3.1 88 MW-30 1-Nov-11 147 0.302J 47.5 8.801 69.81B 3.90J 22.2JB 3.51J 0.196J 44 60.8 MW-30 25-Apr-12 169 0.773J 58 9.94J 73.9 9.17J 22.7J 2.151 0.360J 51.7 54.7 MW-30 23-Oct-12 197 57.5 11.3 80.2 9.44J 26.3 0.359J 54.4 62.6 MW-30 17-Apr-13 450 2.8 0.1J 124 24 155 17 0.04J 56 11 146 141 MW-30 16-Oct-13 220 1.4 49 91 63 6J 0.03J 21J 0.3J 50 40 MW-30 16-Apr-14 220 1.4 66 11 78 7J 0.02J 26J 0.5J 73 71 MW-30 12-Nov-14 500 3.0 0.2J 148 24 169 19 0.07J 59 2J 1.11 154 148 MW-30 29-Apr-15 180 1.2 59 91 67 6J 23J 0.4J 48 53 MW-30 15-Oct-15 0.4J 60J 1.2 0.7J 48 11 12 2J 0.05J 10J 0.06J 63 44 MW-30 21-Apr-16 150 0.8J 46 7J 54 5J 0.02J 18J 0.3JB 29 38 MW-30 14-Sep-16 0.17JB 50J 0.36J 0.053J 8.8J 1.6J 11B 0.95J 4.5J 11J 18B MW-30 20-Apr-17 79J 0.56J 25 3.1J 28 2.2J 8.7J 0.14J 191 22 MW-30 22-Sep-17 M W-30 12-Apr-18 MW-30 24-Oct-18 i0.i Not Sampled MW-30 25-Apr-19 MW-30 5-Nov-19 MW-30 8-Apr-20 MW-30 15-Oct-20 1.4J 67 0.32J 0.46J 7.1 1.3J 11 2.4 4.2J 8.4 29 MW-30 (dissolved) 15-Oct-20 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-30 31-Mar-21 78 0.26J 0.16J 13 2.5J 9.4 2.5 4.2J 11 24 MW-30 (dissolved) 31-Mar-21 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA Smith Page 9 of 23 June 2021 Table 4a Detected Groundwater Constituents - Metals March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 MW-31 1-Nov-11 84.2J 0.151J 33.3 2.57J 23.91B 7.27J 13.7JB 2.66J 0.129J 26.2 57.9 MW-31 25-Apr-12 33.4J 0.122J 13.1 6.71J 3.56J 5.401 0.904J 9.25J 33.1 MW-31 23-Oct-12 35.7J 14 6.52J 3.76J 5.09J 9.26J 53.6 MW-31 17-Apr-13 70J 0.4J 24 11 14 7J 0.03J 8J 0.051 18J 29B MW-31 16-Oct-13 30J 0.11 11 0.4J 5J 2J 5J 5J 13B MW-31 16-Apr-14 901 0.5J 0.2J 32 2J 18 10 0.07J 8J 0.07J 35 70 MW-31 12-Nov-14 0.5J 110 0.7J 41 2J 26 14 0.08J 11J 0.1J 37 29 MW-31 29-Apr-15 50J 0.2J 14 0.6J 7J 4J 0.03J 3J 13J 14 MW-31 14-Oct-15 0.5J 120 0.6J 38 2J 24 13 0.111 9J 0.08J 37 37 MW-31 21-Apr-16 0.6J 70J O.SJ 30 2J 17 12 0.14J 5J 0.07JB 26 17 MW-31 13-Sep-16 29J 0.23J 13 0.64J 5.61B 3.4J 2.OJ 12J 12 MW-31 19-Apr-17 28J 8.1 3.9J 1.8J 2.6J 0.221 5.2J 12 M W-31 21-Sep-17 M W-31 12-Apr-18 M W-31 24-Oct-18 ° Not Sampled MW-31 24-Apr-19 M W-31 5-Nov-19 M W-31 8-Apr-20 MW-31 15-Oct-20 41 0.22J 16 7.8 3.9 7.4 14 14 MW-31 (dissolved) 15-Oct-20 NA NA NA NA NA 3.0 NA NA NA NA NA NA NA NA NA NA MW-31 31-Mar-21 25 115 5.3 2.1 1.6J 12 6.3J MW-31d 31-Oct-11 1.21J 21.2J 13.4 34.2E 4.99JB 10.2J 69.6 MW-31d 24-Apr-12 1.68J 17.1J 6.79J 26.5 0.944J 7.62J 12.6 MW-31d 22-Oct-12 7.20J 19.3J 8.24J 1.82J 7.99J 43.5 MW-31d 16-Apr-13 0.5J 20J 6J 0.08J 0.8JB iJ 6J 21B MW-31d 15-Oct-13 0.8J 20J 6J 0.06J iJ 0.8J 51 16B MW-31d 15-Apr-14 0.7J 20J 51 0.091 0.81 0.91 91 24B MW-31d 11-Nov-14 0.5J 20J 6J 0.08J 0.8J 0.7J 2J 7J MW-31d 28-Apr-15 1.1J 20J 6J 0.07J 0.9J 0.81 51 24 MW-31d 13-Oct-15 1.2J 20J 0.3J 6J 0.05J 3J 0.2J 0.04J iJ 4J 30 MW-31d 21-Apr-16 20J 4J 0.7J 0.91 2J 5J MW-31d 13-Sep-16 0.59J 18J 0.14J 5.3J 1.5JB 1.2J 7.2J 56 MW-31d 19-Apr-17 18J 5.4J 2.6J 6.6J 53 MW-31d 18-Sep-17 191 4.4J 1.0J 7.8J 2.6J MW-31d 13-Apr-18 0.51J 18J 5.3J 4.6J 25 OW-31d (dissolved) 13-Apr-18 NA NA NA NA NA NA NA NA NA NA NA NA NA NA 4.1 NA MW-31d 24-Oct-18 21J 6.6J 0.28J 1.8J 9.91 4.OJ MW-31d 24-Apr-19 21J 4.2J 7.8J MW-31d 5-Nov-19 0.63J 17 0.21J 4.1J 1.6J 0.092J 6.3 84B MW-31d 8-Apr-20 18 4.4J 0.43J 7.6 20 OW-31d (dissolved) 8-Apr-20 NA NA NA NA NA NA NA NA NA NA NA NA NA NA 7.3 NA MW-31d 15-Oct-20 0.80J 19 4.4J 6.6 26 MW-31d 31-Mar-21 0.991 20 0.20J 4.9J 1.91 6.6 87 Smith Page 10 of 23 June 2021 Table 4a Detected Groundwater Constituents - Metals March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 MW-32 1-Nov-11 5.751 14.2.1 3.41.1 1.47J 10.06 3.39J 2.96J 27.7 MW-32 25-Apr-12 0.393J 3.371 15.4.1 0.261.1 1.92.1 2.34J 8.49J 1.96J 5.71J 6.22J MW-32 23-Oct-12 30J 6.71.1 3.30J 27.2 5.04J 11.8J 13.1 MW-32 17-Apr-13 30J 0.3.1 5J 3J 22 0.5J 5J 91 8.113 MW-32 16-Oct-13 70J 0.6.1 0.3J 11 6J 50 0.91 101 0.1J 32 25 MW-32 16-Apr-14 20J 0.3.1 2J 2.1 81 0.2J 2J 7J 10B MW-32 12-Nov-14 50J 0.5.1 11 5.1 37 0.91 91 0.1J 15J 18 MW-32 29-Apr-15 0.61 140 1.6 0.1J 27 18 131 1 24J 0.3J 77 58 MW-32 14-Oct-15 170 1.4 0.1J 29 18 135 2J 0.04J 25J 0.3J 91 53 MW-32 21-Apr-16 40J 0.5.1 6J 5.1 28 0.51 6J 0.08JB 17J 18 MW-32 13-Sep-16 40J 0.63.1 0.20J 8.5.1 5.6.1 27B 0.75J 7.2J 0.086J 18J 19 MW-32 20-Apr-17 11J 0.30J 1.6.1 0.90J 5.1J 1.4J 2.7J 3.5.1 MW-32 22-Sep-17 0.66J 14J 0.17J 1.6.1 1.3J 1.1 4.0.1 MW-32 13-Apr-18 8.5.1 0.30J 1.5.1 2.7.1 MW-32 25-Oct-18 13J 0.26.1 3.1J 1.8J 1.6J 2.5.1 MW-32 (dissolved) 25-Oct-18 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-32 25-Apr-19 26J 0.33.1 0.30J 2.6.1 11 9.51 5.01 4.7J 27 MW-32 (dissolved) 25-Apr-19 NA NA NA NA NA NA 6.2 NA NA NA NA NA NA NA MW-32 7-Nov-19 13 0.21J 2.4J 3.6J 0.28 2.2J 3.0.1 MW-32 (dissolved) 7-Nov-19 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-32 8-Apr-20 14 0.24J 3.5.1 2.4.1 13 0.42J 3.0J 2.5J 14 MW-32 (dissolved) 8-Apr-20 NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-32 15-Oct-20 5.6 0.27J 5.9.1 MW-32 31-Mar-21 0.62J 11 0.27J 1.8J 3.5.1 4.2J 1.81 3.6J 11 TB-1a 1-Nov-11 126 5.39 19.1 11.5 99.313 19.01 40.5 91.8 TB-1a 25-Apr-12 0.269J 190 1.5 29 22 158 7.33J 0.348 27.9J 0.1861 61.3 89.4 TB-1a 23-Oct-12 85.41 0.584J 11.3 14.8 59.6 2.35J 13.3J 25 48.2 TB-1a 17-Apr-13 40J 0.061 0.3J 5J 91 24 0.91 0.1J 6J 91 11B TB-1a 16-Oct-13 60J 0.081 0.3J 6J 10 35 11 0.12.1 91 14J 14B TB-1a 16-Apr-14 101 1.2 0.7J 5.1 3J 0.3J 0.13.1 3J 5J 16B TB-1a 12-Nov-14 80J 0.21 2.7 101 91 54 2J 0.34 12J 0.081 191 41 TB-1a 29-Apr-15 0.61 30J 0.061 1.9 4J 5.1 18 11 0.22 6J 6J 17 TB-1a 15-Oct-15 70J 0.1J 2.5 8J 11 40 2J 0.22 13J 17JB 45 TB-1a 21-Apr-16 50J 0.7J 6J 6J 33 11 0.22 7J 0.06JB 6J 18 TB-1a 14-Sep-16 0.1716 99J 0.23J 1.7 12 11 72B 3.5J 0.72B 15J 0.111 29 49B TB-1a 20-Apr-17 17J 0.37.1 1.0.1 3.6J 0.050J 1.9J 5.1J 5.5J TB -la 22-Sep-17 TB-1a 12-Apr-18 TB -la 24-Oct-18 TB-1a 24-Apr-19 Not Sampled(4) TB -la 5-Nov-19 TB-1a 8-Apr-20 TB -la 14-Oct-20 TB-1a 31-Mar-21 19 1 1 6.6 1 6.5 1 3.2J 4.7J I 0.48J I 0.10J I 4.7J 3.1J 1 21 Smith Page 11 of 23 June 2021 Table 4a Detected Groundwater Constituents - Metals March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 TB -la deep 31-Oct-11 0.8651 14.2.1 22.9 4.52JB 6.60J6 1.13J 7.66J 13.2 TB -la deep 24-Apr-12 0.9281 15.5.1 15 11.5 3.87J 1.23J 6.58J 8.41J TB -la deep 23-Oct-12 18.0.1 14.9 6.85J 8.29J 6.51J 10.4 TB -la deep 16-Apr-13 2.3J 20J 0.2J 12 0.91 81 0.5J 5J 2J 16B TB -la deep 15-Oct-13 2.2J 20J 0.11 6J 1J 6J 5J 4J 1 9.113 TB -la deep 15-Apr-14 2.1J 20J 0.1J 7J 0.8J 5J 0.4J 1 81 17B TB -la deep 11-Nov-14 2.9J 30J 0.1J 7J 1.1 5J 0.51 4J 18 TB -la deep 28-Apr-15 2.4J 30J 0.1J 7J 0.8J 4J 0.4J 5J 2J 12 TB -la deep 14-Oct-15 10J 4J 0.04J 11 TB -la deep 20-Apr-16 0.4J 20J 4J 0.7J 2J 0.2J 1 61 TB -la deep 13-Sep-16 0.66J 22J 0.070J 3.1J 0.46.1 1.7JB 0.26J 3.2J 6.4J 12 TB -la deep 19-Apr-17 0.74J 25J 3.2.1 3.0J 3.1 3.9J 13 TB -la deep 22-Sep-17 0.76J 151 3.4.1 3.4J 6.8J TB -la deep 13-Apr-18 2.1J 13J 3.1J 1.4J 0.28J 13 TB -la deep 24-Oct-18 13J 5.2.1 1.6J 6.5J TB -la deep 24-Apr-19 13J 29 15J 3.9J TB -la deep 5-Nov-19 1.7J 23 0.66 2.4.1 5.0 0.64J 2.8J 4.1J 38B TB -la deep 6-Apr-20 1.5J 24 0.291 2.8.1 3.6J 0.61J 2.9J 65 TB -la deep (dup) 6-Apr-20 1.91 23 0.271 21 3.7J 0.55J 3.5J 70 TB -la deep 14-Oct-20 2.2 27 0.44J 2.0J 2.4J 0.99J 2.4J 3.1J 82 TB-1a deep 31-Mar-21 0.53J 17 0.28J 4.8J 2.3J 3.4J 25 MW-33 25-Apr-12 112 0.208J 44.4 15.1 37 6.44J 20.2J 0.917J 72.1 102 MW-33 17-Apr-13 70J 0.3.1 17 51 13 2J 7J 34 33 MW-33 15-Apr-14 40J 51 0.61 11 2J 8J 9.113 MW-33 29-Apr-15 50J 0.07J 7J 11 3J 0.4J 3J 8J 15 MW-33 21-Apr-16 0.51 1001 0.1J 17 41 12 2J 7J 21J 35 MW-33 20-Apr-17 29J 5.1J 1.5J 5.9J 7.41 MW-33 13-Apr-18 28J 5.3J 3.1 6.31 MW-33 24-Apr-19 59J 4.3J 1.6J 1.7J 4.0J 4.81 MW-33 8-Apr-20 71 0.25J 0.66 41 8.1 22 2.7 14 42 77 MW-33 (dissolved) 8-Apr-20 NA NA NA NA NA 3.8J NA NA NA NA NA NA NA NA MW-33 31-Mar-21 1 56 1 7.3 1 1 1 1.7J 3.7J 5.21 MW-34 26-Apr-12 0.261J 184 1.27 25.4 4.771 23.813 8.3J 0.255 13.2J 37.4 53.7 MW-34 17-Apr-13 560 5 0.31 75 17 90 21 0.45 49J 0.3J 239 282 MW-34 15-Apr-14 110 0.3J 0.21 3J 11 0.8J 0.25 2J 3J 16B MW-34 29-Apr-15 220 1.5 0.21 24 51 24 51 0.33 15J 0.11 47 76 MW-34 21-Apr-16 150 0.5J 91 21 51 0.8J 0.171 51 0.08JB 2J 32 MW-34 20-Apr-17 84J 0.29.1 4.4.1 1.4J 0.25 2.0J 1.5J 13 MW-34 13-Apr-18 130 0.63J 8.6.1 1.81 6.8J 1.2J 1.1 5.2J 7.1J 21 MW-34 (dissolved) 13-Apr-18 NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-34 25-Apr-19 170 0.62J 0.211 14 2.51 10 1.9J 0.30 6.9J 14J 30 MW-34 (dissolved) 25-Apr-19 NA NA NA NA NA 2.0J 1.71 NA NA NA NA NA NA NA NA MW-34 7-Nov-19 190 1.7 0.96B 31 4.01 26 5.0 1.6 16 1.5J 0.20BJ 37 49 MW-34 (dissolved) 7-Nov-19 NA NA NA NA NA 4.2.1 NA NA 0.49 NA NA NA NA MW-34 9-Apr-20 120 0.47 0.31J 13 1.91 7.6 1.4 0.28 6.4 7.0 35 MW-34 (dissolved) 9-Apr-20 NA NA NA NA NA 2.9.1 NA NA NA NA NA NA NA NA MW-34 15-Oct-20 89 0.26J 4.1J 1.3J 2.6J 13 MW-34 31-Mar-21 240 0.91 0.301 28 7.9 13 2.4 0.13J 11 16 36 MW-34 (dissolved) 31-Mar-21 NA NA NA NA NA 6.2 NA NA NA NA NA NA NA NA NA Smith Page 12 of 23 June 2021 Table 4a Detected Groundwater Constituents - Metals March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 MW-34d MW-34d MW-34d MW-34d MW-34d MW-34d MW-34d MW-34d MW-34d MW-34d MW-34d MW-34d 25-Apr-12 16-Apr-13 15-Apr-14 28-Apr-15 21-Apr-16 20-Apr-17 11-Apr-18 23-Apr-19 6-Nov-19 8-Apr-20 15-Oct-20 31-Mar-21 0.575J 0.6J 0.4J 0.8J 1.2J 3.1 1 0.51 32.5.1 20J 20J 20J 180 20J 20J 21J 25 27 28 1 26 0.1J 0.1J 0.1J 0.8J 0.14J 0.15J 0.3.1 0.2J 0.3J 0.1J 1.8 1.7 0.82 1 2.2 8.02J 4J 4J 5J 15 6.4J 12 6.5.1 8.7 7.9 7.1 1 9.8 0.11 0.091 0.08J 3J 5.86,113 1,113 2J 1J 12 4.1 4.9J 1.6J 1 2.9J 2.66J 0.6J 0.5J 0.5J 2J 0.90J 0.90J 0.27J 0.05J 0.191 0.073J 0.46 0.20E 0.7J 0.5J 8J 1.4J 1.51 1.1 0.1JB 1.57J 4J 12J 2.OJ 7.83J 2.113 11B 6.1 35 3.0.1 19 19 22 12 MW-35 25-Apr-12 51.31 0.6161 3.961 2.36.1 5.67J 3.10J 11.3J 17.8 MW-35 17-Apr-13 60J 0.8.1 0.1J 51 2.1 7J 2J 4J 16J 12B MW-35 16-Apr-14 60J 1.01 0.3J 6J 3.1 81 2J 4J 22J 26B MW-35 29-Apr-15 70J 1.0 0.1J 7J 41 91 2J 0.021 51 0.06J 22J 20 MW-35 20-Apr-16 50J 0.71 4J 2.1 5J 1J 3J 111 12 MW-35 20-Apr-17 38J 0.39.1 2.3.1 6.5J 2.4J 5.OJ 3.7J 3.9J 66 MW-35 13-Apr-18 29J 0.281 0.24J 1.51 3.3.1 0.48J 32 MW-35 24-Apr-19 38J 0.41.1 2.1J 1.6J 1.6J 0.38J 1.1 3.1J 14 MW-35 9-Apr-20 36 0.4 2.2.1 1.6.1 1.9J 0.48J 1.8J 33 MW-35 31-Mar-21 36 0.40 4.1J 0.61J 3.3J 11 MW-36 1-Nov-11 74.61 12.1 3.63.1 14.713 7.15J13 14.8J 31.8 MW-36 25-Apr-12 64.7.1 7.90J 2.611 9.44J 4.31 12.5J 12.1 MW-36 23-Oct-12 216 68.8 18.8 84 8.62J 29.3J 0.420J 91.7 72 MW-36 (dup) 23-Oct-12 73.7.1 11.6 3.49.1 13.4 6.09J 0.121.1 16.8J 18.4 MW-36 17-Apr-13 50J 0.11 6J 2.1 6J 0.5J 4J 8J 12B MW-36 16-Oct-13 0.61 60J 0.2.1 7J 2.1 81 0.6J 4J 0.05J 101 4.113 MW-36 16-Apr-14 901 0.31 19 5.1 23 2J 91 0.11 33 32B MW-36 12-Nov-14 130 0.6J 32 91 39 1 151 0.3J 40 46 MW-36 30-Apr-15 0.6J 100J 0.31 24 7J 27 2J 0.02J 11J 0.2J 29 27 MW-36 15-Oct-15 130 0.7J 38 10 46 1 0.05J 16J 0.3J 37 41 MW-36 20-Apr-16 70J 0.31 13 3.1 15 11 6J 0.11 111 17 MW-36 13-Sep-16 62J 0.24.1 0.047J 11 3.0.1 106 0.88J 5.1 0.088J 14J 16 MW-36 20-Apr-17 40J 2.81 2.9J 1.8J 4.4J 11 MW-36 22-Sep-17 70J 0.32.1 16 3.3.1 18 1.1 6.6J 20J 16 MW-36 (dissolved) 22-Sep-17 NA NA NA NA NA NA NA NA NA NA NA NA 4.9J NA MW-36 13-Apr-18 54J 0.29.1 5.4.1 3.1 0.75J 1.81 3.2J 4.0.1 MW-36 (dissolved) 13-Apr-18 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA MW-36 25-Oct-18 80J 0.20J 27 4.8.1 20 1.6J 12J 25 25 MW-36 (dissolved) 25-Oct-18 NA NA NA NA NA 2.3.1 NA NA NA NA NA NA NA NA MW-36 25-Apr-19 180 0.33J 57 11 55 4.1 181 0.31J 55 59 MW-36 (dissolved) 25-Apr-19 NA NA NA NA NA 3.81 NA NA NA NA NA NA NA MW-36 7-Nov-19 81 0.40 21 4.5.1 23 1.5 0.21 8.2 0.17BJ 23 25 MW-36 (dissolved) 7-Nov-19 NA NA NA NA NA 1.51 NA NA NA NA NA NA NA NA MW-36 9-Apr-20 120 0.31J 35 7.8 35 2.8 14 0.23J 35 33 MW-36 (dissolved) 9-Apr-20 NA NA NA NA NA 1.91 NA NA NA NA NA NA 1.6 NA MW-36 15-Oct-20 51 4.8J 3.8J 0.27J 2.6J 5.5 7.0.1 MW-36 31-Mar-21 65 21 2.8.1 12 0.97J 4.9J 14 12 MW-36 (dissolved) 31-Mar-21 NA NA NA NA NA 5.7 NA NA NA NA NA NA NA NA NA NA Smith Page 13 of 23 June 2021 Table 4a Detected Groundwater Constituents - Metals March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 Notes: 1. All units are in micrograms per liter (parts per billion). 2. * - Interim Maximum Allowable Concentration (IMAC) 3. ** - The upper tolerance limits (UTL) were calculated as part of the North Wake Unlined Alternate Source Demonstration and were approved by the Solid Waste Section on August 17, 2020. 3. dup - Duplicate Sample 4. (4) - Monitoring wells were not sampled due to an insufficient volume of water in the well. 5. J - Indicates the analytical result is an estimated concentration between the method detection limit and the limit of quantitation. 6. S - Matrix spike/matrix spike duplicate failure 7. B - The analyte concentration detected in the method blank was greater than the method detection limit. 8. D - Dilution greater than 1 9. Monitoring wells MW-28, -28d, -33, and -35 are sampled yearly during the spring event. 10. Dissolved metal samples were collected to evaluate the influence of turbidity on total metal concentrations. 11. NA - Not Analyzed Concentration exceeds the 15A NCAC 02L .0202 (North Carolina 2L), IMAC, or UTL. Indicates the result is below the detection limit. Smith Page 14 of 23 June 2021 Table 4b Detected Groundwater Constituents - Volatile and Semi -Volatile Organic Compounds March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 MW-ll 1-Nov-11 MW-11 25-Apr-12 MW-11 23-Oc -12 MW-11 17-Apr 13 MW-11 16-Ocb13 MW-11 16-Apl-14 MW-11 12-Nov-14 MW-11 30-Apf-15 0.541 MW-11 15-Ocbl5 0.28JB MW-11 21-Ap,16 MW-11 1-Sep-I6 MW-11 20-Ap,17 MW-11 22-Sep-17 MW-11 13-Ap,18 2.11 MW-11 25-0ct-18 MW-11 25-Ap,19 MW-11 5-Nov-19 -- MW-11 8-Ap,20 -- MW-11 14-0ct-20 -- MW-11 31-Mar-21 MW-lld 2-Nov-11 MW-lld 26-Ap, 2 MW-lld 24-0ct-12 MW-lld I8-Ap,13 MW-lld 17-0ct-13 MW-lld 17-Ap,14 MW-lld 13-Nov-14 MW-lld 29-Ap,15 MW-lld 15-0ct-15 0.241B MW-lld 21-Ap,16 1.3J 0.71J MW-lld 1-Sep-I6 MW-lld 20-Ap, 7 MW-lld 22-Sep-17 MW-lld 12-Apf-IR MW-lld 23-Oct-I8 MW-lld 25-Ap,19 MW-lld 5-Nov-11 -- MW-lld (dup) 5-Nov-19 -- MW-lld 8-Apr20 -- MW-lld 13-Oa-20 -- MW-lld 31-Mar21 4.41E MW-5R 16-Ma,11 2.1 MW-5R 31-0ct-I1 MW-SR 24-Ap, 2 MW-SR 22-Oct-12 0.671 MW-SR 17-AP, 3 0.22) MW-SR 16-Oct-13 MW-SR 16-Ap,14 MW-SR 12-Nov-14 MW-SR 30-Ap, 5 MW-SR 15-0ct-15 0.491 0.341B MW-SR 21-Ap, 6 MW-SR 14-Sep-16 MW-SR 20-Ap, 7 MW-SR 20-Sep-17 5.01 3.4 1.11 0.6E 0.721 4.8 MW-5R I1-Ap,18 MW-5R 24-0ct-18 0.411 MW-5R 22-Ap,19 0.75 0.54 2.5 0.51 52 0.44J 0.54 MW-5R 6-Nov-19 0.61 0.62 -- MW-5R 4-Feb-20 -- MW-5R 8-Apr20 33OD 42JD -- MW-5R 30-Jul-20 790D 32JD -- MW-5R 15-Oct-20 151 6.61 -- 1.55 2.71 28 MW-5R 31-Ma,21 29H 3.71 1.4 6.1 MW-6 16-Mar11 3.4 1.31 1.6 0.421 1.31 1.8 MW-6 I-Nov-11 3.6 1.11 1.7 1.01 0.951 MW-6 24-Apr12 0.71 0.51 0.5) 0.421 0.561 MW-6 22-Oa-12 4.61 2.3 1.71 1.3 2.51 0.591 1.4 MW-6 1]-Apr13 0.79) 1.71 0.43J MW-6 16-Oa-13 0.48) 3.OJ 0.60J 0.57J MW-6)dup) 16-Oct-13 8.21 0.541 3.01 0.55J 0.54J MW-6 16-Ap114 0.52) 0.97J MW-6)dup) 16-Apr14 0.50) 1.01 MW-6 12-Nov-14 1.1 0.251 1.2J 1.3 0.80J MW-6 30-Apr15 0.481 0.60) 1.21 MW-6 14-Oa-15 0.62) 2.3J 0.501 MW-6 20-Apr16 0.45) 0.521 3.01 MW-6)dup) 20-Ap, 6 0.38) 0.58J MW-6 14-5ep-16 0.83) 1.51 MW-6 20-Ap,17 0.82) 0.981 MW-6(dup) 20-Apr17 0.90) 1.21 MW-6 21-Sep-17 0.83) 2.8J 0.61J 0.561 MW-6 12-Apr18 0.691 0.841 MW-6 24-0c[-I8 0.61 1.3 2.2 0.56 26 0.47J MW-6 22-Apr19 4.9 MW-6 6-Nov-19 1.3 L. 24 MW-6 7-Apr20 0.491 1.1 10 MW-6 IS-Oc[-20 1.2 0.53 16 MW-6 31-Marv21 0.68 5.0 C WM Page 15 of 23 June 2021 Imlith Table 4b Detected Groundwater Constituents - Volatile and Semi -Volatile Organic Compounds March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 MW-6d 2-Nov-11 0.721 1.5) 3.41 0.431 MW-6d 26-Apr-12 0.611 0.53J 2.3J 0.401 0.421 MW-6tl )dup) 26-Apr-12 0.581 2.31 0.431 MW-6d 23-OC-12 0.77J 1.1) 3.0J 0.541 0.481 0.531 0.521 MW-6tl 18-Apr-13 0.521 2.31 0.481 0.31 0.391 MW-6d (dup) I8-Apr-13 0.581 2.4J 0.4]1 0.39J 0.441 0.361 MW-6tl 17-0c-13 0.75J 1.8) 3.31 065J 0.531 MW-6d 17-Apr-14 0.42J 0.93J 0.281 MW-6tl 12-Nov-14 0.51J 1.51 0.38J MW-6d 30-Apr-15 0.30J 0.501 0.87J I.SJB 0.221 MW-6d)dup) 30-Apr-15 0.40J 0.83J 1.516 MW-6d 15-Ocb15 0.35J 0.37J 0.821 0.25JB MW-6d 20-Apr-16 0.511 2.01 0.3516 MW-6d 12-Sep-16 0.41J 1.01 MW-6d 20-Apr-17 0.511 0.. 1.51 0.5D 1.61 MW-6d 22-Sep-17 0.60J 0.71J 1.91 0.49J MW-6d 13-Apr-18 0.81J MW-6d 24-Oct-18 0.99 MW-6d 23-Apr-19 0.97 MW-6d 6-Nov-19 0.50 1.1 - MW-6d 7-Apr-20 0.54 -- MW-6d 13-Oct-20 0.74 -- MW-6d 31-Mar-21 0.461 1.1 MW-7 2-Nov-11 7.61 MW-7 26-Apr-12 120 0.661 0.791 0.491 MW-7 22-Oct-12 15 0.751 1.4 0.93 MW-7 I6-Apr-l3 0.661 0.25J 1.2 1.21 MW-7 16-Ocb13 0.811 0.40J 1.5 MW-7 I6-Apr-14 0.611 0.521 1.2 0.3L MW-7 11-Nov-14 0.701 0.571 0.561 1.2 0.32J 0.801 MW-7 30-Apr-15 �.1 0.691 2.7 2.81 0.511 0.591 1.516 0.851 MW-7 14-Oct-IS 0.521 0.69J 1.1 MW-7 20-Apr-16 0.83J 0.521 2.2 0.461 1.6J 1.5 MW-7 13-Sep-16 1.0 1.31 1.6 0.421 0.41J 0.601 MW-7 18-Apr-17 0.]41 1.11 IA MW-7 18-Sep-17 0.551 0.94J 0.73) MW-7 I1-Apr-18 0.561 0.51) MW-7 25-Oct-18 0.66 MW-7 24-Apr-19 0.48J 1.0 MW-7 4-Nov-19 0.411 0.83 0.77 -- MW-7 8-Apr-20 0.73 -- MW-7 14-Oct-20 0.80 1.3 1.4 0.43J -- MW-7 31-Mar-21 1.1 1.2 0.53 2.2 MW-8 31-Oct-I1 0.661 14 MW-8 24-Apr-12 0351 23 MW-8 22-OC-12 0.471 0.40J 1.11 25 0.651 0.4L MW-8 1]-Apr-13 0.511 0.23J 0.531 0.]71 35 0.321 0.47J MW-8 16-OC-13 0.481 0.171 0.47) 0.62J 37 MW-8 16-Apr-14 0.4]1 067) 0.581 39 0.401 MW-8 12-Nov-14 0.50J 0.181 0.541 0.641 48 0.321 MW-8 30-Apr-15 0.841 0.35J 1.1 0.94J 98 1.6JB 0.291 0.641 .401 MW-8 15-Oct-15 0.561 0.271 1.0 0.55J 64 0.441B 0.541 MW-8 21-Apr-16 a 701 0.36J 1.4 0.74J 100 0.251 .451 MW-8 14-Sep-16 0.53J 1.2 0.71J 61 0.721 MW-8 20-Apr-17 0.491 1.2 0.50J 48 0.611 .571 MW-8 18-Sep-17 0.54J 1.4 0.44J 46 0.521 MW-8 12-Apr-18 0.621 1.6 0.431 42 0.411 1.8 MW-8 24-Oct-18 0.56 1.6 33 5.8 MW-8 22-Apr-19 8.3 MW-8(dup) 22-Apr-19 8.4 MW-8 6-Nov-19 0.471 1.4 24 4.1 MW-8 7-Apr-20 1.1 14 1.81 MW-8 15-Oct-20 0.71 0.481 2A 31 8.9 0A11 MW-8 31-Mar-21 7.9H1 0.62 0.40J 1.8 0.441 23 1.31 MW-8d 2-Nov-11 MW-8d 26-Apr-12 0.42J MW-8d 24-0ct-12 0.5D MW-8d 18-Apr-13 0.36J MW-8d 17-0ct-13 0.431 MW-8d 17-Apr-14 MW-8d 12-Nov-14 MW-8d 30-Apr-15 0.38J MW-8d 15-0ct-15 0."1 MW-8d 21-Apr-16 0.60J MW-8d 14-Sep-16 0.48J MW-8d 20-Apr-17 0.50) MW-8d 18-Sep-17 MW-8d)dup) 18-Sep-17 MW-Bd 12-Apr-18 MW-Sd 23-OU-I8 MW-8d(dup) 23-OC-18 MW-8d 23-Apr-19 MW-8d 6-Nov-19 -- MW-8d 8-Apr-20 -- MW-Id 13-Oct-20 -- MW-8d 31-Mar-21 -- MW-8d du 31-Mar-21 C Page 16 of 23 June 2021 Smith Table 4b Detected Groundwater Constituents - Volatile and Semi -Volatile Organic Compounds March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 MW-29tl 1-Nov-11 MW-29d 26-Apr-12 VW-29tl 24Z-12 MW-29d IB-Apr-13 VW-29tl 17-Oc-13 MW-29d 17-Apr-14 28.5 MW-29tl 13-Nov-14 0.231 4.61J MW-29d 29-Apr-15 6.71 MW-29tl IS-Oc-15 0.291B 0.251 MW-29d 21-Apr-16 MW-29d 12-Sep-16 MW-29d 19-Apr-17 MW-29d 22-Sep-17 MW-29d 12-Apr-18 0.571 MW-29d 24-Oct-I8 0.41J MW-29d 25-Apr-19 MW-29tl 5-Nov-19 -- MW-29d 6-Apr-20 — 1.4J MW-29tl 14-0ct-20 -- MW-29d 31-Mar-21 MW-30 1-Nov-11 MW-30 25-Apr-12 MW-30 23-0ct-12 MW-30 17-Apr-13 MW-30 I6-Oct-13 MW-30 16-Apr-14 MW-30 12-Nov-14 MW-30 29-Apr-15 MW-30 IS-0ct-15 MW-30 21-Apr-16 MW-30 14-Sep-16 MW-30 20-Apr-17 MW-30 22-Sep-17 MW-30 12-Apr-18 MW-30 MW-30 24-0ct-I8 25-Feb-19 Not sampled MW-30 5-Nov-19 MW-30 8-Apr-20 MW-30 15-0ct-20 -- MW-30 31-Mar-21 MW-31 1-Nov-11 2.1J MW-31 25-Apr-12 1.31 MW-31 23-0ct-12 2.0J MW-31 17-Apr-13 1.41 MW-31 16-Oct-13 1.41 MW-31 16-Apr-14 1.61 MW-31 12-Nov-14 1.01 MW-31 29-Apr-15 1.6J MW-31 14-Oct-15 0.82J MW-31 21-Apr-16 2.11 MW-31 13-Sep-16 0.7. MW-31 19-Apr-17 0.41J MW-31 21-Sep-17 MW-31 12-Apr-18 MW-31 M W-31 24-0ct-18 24-Apr-19 Not sampled MW-31 4-Nov-19 MW-31 8-Apr-20 MW-31 15-0ct-20 1 -- MW-31 31-Mar-21 0.401 MW-31d 31-Oc[-Il 23 MW-31d 24-Apr-12 23 MW-3A 22-OC-12 22 MW-31d 16-Apr-13 21 MW-31d IS-OC-13 17 MW-31d 15-Apr-14 17 MW-31d I1-Nov-14 17 MW-31d 28-Apr-15 16 MW-31d 13-OU-15 12 MW-31d 21-Apr-16 13 MW-31d 13-Sep-16 10 MW-31d 19-Apr-17 13 MW-31d 18-Sep-17 12 MW-31d 13-Apr-18 9.2 MW-31d 24-Oc[-18 9.4 MW-31d 24-Apr-19 6.a MW-31d 5-Nov-19 6.3 — MW-31d 8-Apr-21 3.8 — MW-31d 8-Apr-20 5.0 -- MW-31d 31-Mar-21 4.1 MW-32 I-Nov-11 MW-32 25-Apr-12 VW_ 32 23-OU-12 VW-2 17-Apr-13 VW_ 16-OU-13 MW-32 16-Apr-14 MW-32 12-Nov-14 MW-32 29-Apr-15 0.411 MW-32 14-Od-15 MW-32 21-Apr-16 MW-32 13-Sep-16 MW-32 20-Apr-17 MW-32 22-Sep-17 MW-32 13-Apr-18 MW-32 25-Od-I8 MW-32 25-Apr-19 MW-32 7-Nov-19 0.64 -- MW-32 8-Apr-20 1.2 — M W-32 16-Od-20 5.2 -- MW-32 31-Mar-21 0.97 smithPage 19 of 23 June 2021 Table 4b Detected Groundwater Constituents - Volatile and Semi -Volatile Organic Compounds March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 TS-la 1-Nov-11 1.61 TB -la 25-Apr-12 0.91 TB -la 23-Oc- 2 0.74J TB -la 17-Apr-13 0.701 TB -la 16-0ct-13 0.35J TB -la 16-Apr-14 0.451 0.321 TB -la 12-Nov-14 0.60J TB -la 29-Apr-15 1.51 TB -la 15- Oct- 15 0.45J 0.271E TB -la 21-Apr-16 TB -la 14-Sep-16 0.65J TB -la 20-Apr-17 0.421 TB -la 22-Sep-17 TB -la 12-Apr-18 TB -la 24-Oct-I8 TB -la 24-Apr-19 Net -pled 141 TB -la 5-Nov-19 TB -la 8-Apr-20 TB -la 14-0ct-20 TB -la 31-Mar-21 TB -la deep 11-Oct-Il 31 TB -la deep 24-Apr-12 23 TB -la deep 23-Oct-12 22 TB -la deep 16-Apr-13 20 TB -la deep 15-0ct-13 16 TB -la deep 15-Apr-14 13 TB -la deep I1-Nov-14 10 TB -la deep 28-Apr-15 8.9 0.421 TB -la deep 14-Oct-15 4.9J TB la deep 20-Apr-16 2.61 0.411 TS-la deep 13-Sep-16 2.61 TB -la deep 19-Apr-17 2.71 1.4J TB -la deep 22-Sep-17 1.91 TB -la deep 13-Apr-18 1.31 TB -la deep 24-Oct-I8 0.85 TB -la deep 24-Apr-19 0.56 TB -la deep 5-Nov-19 0.65 -- TB -la deep 6-Apr-20 0.54 -- TB -la deep (dup; 6-Apr-20 0.56 -- TB-la deep 14-Oct-20 0.66 -- TB-la deep 31-Mar-21 MW-33 25-Apr-12 MW-33 1]-Apr-13 MW-33 15-Apr-14 MW-31 29-Apr-15 MW-33 21-Apr-16 MW-33 20-Apr-17 MW-33 13-Apr-18 MW-33 24-Apr-19 MW-33 8-Apr-20 MW-33 31-Mar-21 MW-34 26-Apr-12 0.601 0.621 0.60J 1.2 1.81 14 9 7.6 2.2 3.3 0.911 MW-34 1]-Apr-13 0.561 0.601 0.52J 1.1 1.81 13 9.1 7.6 2.1 2.6 0.701 0.191 MW-34 15-Apr-14 0.501 0.99J 0.41J 1.0 1.41 14 7.5 4.1J 1.0 2.2 0.59J MW-34 29-Apr-15 0.851 0.351 0.51J 0.651 1.5 1.]1 IS 0.341 10 7.2 1.3 3.0 0.641 1.71 MW-34 21-Apr-16 0.77J 0.71J 1.9 2.01 17 0.30J 11 6.4 2.3 I.OJ MW-34 20-Apr-17 0.751 0.65J 1.4 2.61 13 0.511 12 9.3 24 2.9 1.2 MW-34 13-Apr-18 0.57J 0.44J 2.11 8.2 12 9.7 1.8 2.1 0.77J MW-34 25-Apr-19 0.65 0.56 1.4 12 8.2 7.1 IA 3.0 0.79 MW-34 6-Nov-19 0.421 0.61 1.1 1.4 6.8 7.1 - 6.6 1.3 1.6 0.72 MW-34 4-Feb-20 0.471 0.411 1.2 1.6 6.1 12 -- 8.5 1.9 2.1 0.71 MW-34 8-Apr-20 0.67 0.54 1.5 2.1 9.1 11 -- 9.9 1.9 2.6 0.91 MW-34 30-Ju1-20 0.52 0.64 1.2 2.2 7.6 8.7 -- 8.4 1.5 1.9 1.0 MW-34 15-Oct-20 0.41J 0.51 1.2 1.9 6.7 9.4 -- 4.4 1.9 2.2 0.80 MW-34 31-Mar-21 0.431 7.0 3.3 1.4 0.87 1.3 MW-34d 25-Apr-12 0.77J 0.93J MW-34d 16-Apr-13 0.831 1.11 MW-34d 15-Apr-14 0.46J 0.991 3.4J 2.7J 0.96J 0.58J 0.76J 0.75J MW-34d 28-Apr-15 0.271 0.42J 0.651 0.701 3.11 2.31 2.11 0.541 0.671 0.381 MW-34d 21-Apr-16 0.791 0.66J 2.0 2.1) 0.33J 10 2.3 "1 MW-34d 20-Apr-17 0.491 1.01 3.1J 2.91 0.781 0.721 0.851 0.591 MW-34d I1-Apr-18 1.7J 1.41 0.571 MW-34d 23-Apr-19 2.0 1.9 0.80 0.45J 0.52 MW-34d 6-Nov-19 0.401 0.75 2.9 2.4 -- 0.93 0.481 0.55 MW-34d 4-Feb-20 0.58 0.16 1.9 -- MW-34d 8-Apr-20 0.431 1.5 1.7 -- 0.59 MW-34d 30-Jul-20 0.76 1.8 3.2 -- 0.461 0.481 0.5] MW-34d 15-Oct-20 0.55 1.5 1.9 -- 0.54 MW-34d 31-Mar-21 4.11L 0.451 2.3 2.2 1.0 0.411 cSmI th Page 20 of 23 June 2021 Table 4b Detected Groundwater Constituents - Volatile and Semi -Volatile Organic Compounds March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 MW-35 25-Apr-12 MW-35 17-Apr-13 0.53J MW-35 16-Apr-14 0.251 MW-35 29-Apr-15 0.441 0.621 0.27J MW-35 20-Apr-16 0.881 0.391 0.411 MW-35 20-Apr-11 1.6J 0.621 0.61J 1.2 MW-35 13-Apr-18 2.21 1.01 0.961 0.81 MW-35 24-Apr-19 0.15 0.54 0.5(5 MW-35 9-Apr-20 1.2 1.0 -- 0.88 1.1 MW-35 31-Mar-21 0.56 0.41J MW-36 I-Nov-11 0.86) 8.9 4.31 1.1 MW-36 25-Apr-12 5.5 3.3J 0.741 MW-36 23-0ct-12 5 2.91 0.661 MW-36(dup) 23-0ct-12 5.4 2.g1 0.671 MW-36 18-Apr-l3 0.18) 3.71 2.31 0.42J M W-36 16-Oct-13 3.81 2.5J MW-36 I6-Apr-14 3.1J 2.11 0.261 0.371 MW-36 12-Nov-14 3.5J 2.5J MW-36 30-Apr-15 0.4W 2.81 2.31 0.231 MW-36 15-0ct-15 2.4J 2.1J 0.37JB 0.25J MW-36 20-Apr-16 I.81 2.11 MW-36 13-Sep-16 4.5J 4.3J MW-36 20-Apr-17 2.41 2.61 MW-36 22-Sep-17 2.4J 3.1J MW-36 13-Apr-18 3.21 1.61 2.11 MW-36 25-0ct-18 1.8 3.2 MW-36 25-Apr-19 1.4 2.8 MW-36 5-Nov-19 1.5 2.8 - MW-36 7-Apr-20 1.6 3.0 -- MW-36 15-0ct-20 1.8 3.6 -- 0.421 MW-36 31-Mar-21 1.1 2.2 MW-36d 2-Nov-11 1.41 1.2 4.0J 0,891 1.0 1.4 MW-36d 26-Apr-12 0.531 t4l 8 4.01 0.861 1.3 MW-36d 24-0ct-12 0.451 0.561 1.31 7.6 3.81 O.S. 0.6g1 1.3 MW-36d 18-Apr I 0.251 7.1 4.01 0.541 0.731 1 MW-36d 17-Oct-13 0.261 0.63) 1.71 7.9 5.5 0.63J 1.1 MW-36d 17-Apr-14 5.1 4.61 0.681 0.871 MW-36d 13-Nov-14 0.541 0.66) 0.53J 6.4 5.5 0.72J 7.9 10 MW-36d 29-Apr-15 0.75) 0.541 6.7 6.5 2.11 0.641 0.87J MW-36d IS-Oct-15 0.37J 4.81 4.7J 0.621 0.33J 0.691 MW-36d 20-Apr-16 0.67) 3.91 0.251 4.91 0.5616 0.40J MW-36d 14-Sep-16 0.69) 5.5 5.8 0.54J 0.50J 0.63J MW-36d 20-Apr-17 0.62) 5.4 5.9 0.431 0.591 0.631 MW-36d 21-Sep-17 1.2J 1.31 MW-36d 13-Apr-18 3.21 3.01 MW-36d 25-Oct-18 3.1 2.6 0.451 MW-36d 24-Apr-19 0.47) 3.2 4.2 MW-36d 7-Nov-19 0.51 3.0 4.5 - MW-36d 9-Apr-20 3.1 5.1 -- MW-36d 13-0ct-20 1.1 2.0 - MW-36d 31-Mar-21 0.53 Notes: 1. All units are in micrograms per liter (parts per billion). 2. `- Interim Maximum Allowable Concentration (IMAC) 3. NS - Not Sampled; dup - Duplicate Sample 4. t" - Monitoring wells were not sampled due to an insufficient volume of water in the well. 5.1- Indicates the analytical result is an estimated concentration between the method detection limit and the limit of quantitation. 6. B -The analyte concentration detected in the method blank was greater than the method detection limit. 7. L- Laboratory control spike/laboratory control spike duplicate failure 8. H - The analyte was out of holding time. 9. (-) -Not Analyzed. 1,4Diozane was removed from the sampling program for all wells on June 26, 2019, with the exceptions of MW-6, -8, and -9, due to two consecutive non -detect events. Concentration exceeds the ISA NCAC 02L.0202 (North Carolina 2L) or IMAC. - Indicates the result is below the detection limits. Smith Page 21 of 23 June 2021 Table 4c Detected Surface Water Constituents - Metals and Volatile Organic Compounds March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 SW-2 17-Mar-11 41J 1.72J 2.27J 0.1941 SW-2 1-Nov-11 77.1J 9.491 2J 5.20BJ 2. 22.OJ 25.7 SW-2 26-Apr-12 33.6J 1.95J 2.03J SW-2 24-Oct-12 35J SW-2 18-Apr-13 40J 0.5BJ 0.11 11 2BJ SW-2 17-Oct-13 0.51 40J 0.11 11 SW-2 16-Apr-14 0.7J 40J 0.81 0.2J 0.4J 0.6J 51 10BJ SW-2 12-Nov-14 40J 0.41 0.06J 0.71 2BJ SW-2 29-Apr-15 40J 0.61 0.2J 11 41 SW-2 15-Oct-15 30J 0.21 0.5J 0.71 0.51 0.071 0.281E SW-2 21-Apr-16 0.61 40J 0.61 0.71 SW-2 14-Sep-16 37J 1.1JB 0.151 2.2J 4.91B SW-2 20-Apr-17 130 0.901 S.OJ SW-2 21-Sep-17 35J 1.61 1.7J 6.1J SW-2 13-Apr-18 36J 1.41 2.6J SW-2 24-Oct-18 34J 2.9J SW-2 24-Apr-19 33J 1.31 4.1J SW-2 7-Nov-19 36 1.41 5.6J SW-2 9-Apr-20 30 2.31 2.31 0.251 5.4J SW-2 14-Oct-20 35 2.7J SW-2 31-Mar-21 44 2.91 5.8 1.6 5.7 11 4.01 SW-3 17-Mar-11 31.7J 1.97J 0.2311 1.86J SW-3 1-Nov-11 33.4J 2.111 5.21JB 2.22BJ 4.06J 6.46J SW-3 26-Apr-12 29.35J 1.631 2.371 3.87J 4.22J SW-3 24-Oct-12 31.3J 1.69J SW-3 18-Apr-13 60J 0.11 3B1 1 2J 2J 10BJ 0.2J 11 SW-3 15-Oct-13 30J 26 0.81 SW-3 15-Apr-14 0.91 20J 0.04J 21 1.01 1 I 91 12B SW-3 11-Nov-14 30J 0.31 0.05J 0.41 0.81 SW-3 29-Apr-15 0.6J 30J 0.31 0.11 0.5J 7.51 0.391 SW-3 14-Oct-15 40J 0.04J 11 0.91 11 0.51 2J 31 9.01 SW-3 21-Apr-16 30J 0.51 0.11 0.51 SW-3 12-Sep-16 0.26J 49J 1.31 3.11 2.91B 1.11 1.11 6.9J 12 SW-3 20-Apr-17 40J 1.71 0.43J 3.3J 4.7J SW-3 20-Sep-17 30J 0.26J 1.21 1.5J 6.9J SW-3 13-Apr-18 31J 1.31 SW-3 24-Oct-18 32J 3.1J SW-3 24-Apr-19 33J SW-3 7-Nov-19 35 0.29J 0.09581 3.6J SW-3 8-Apr-20 32 1.31 SW-3 14-Oct-20 32 SW-3 31-Mar-21 31 2.51 Smith Page 22 of 23 June 2021 Table 4c Detected Surface Water Constituents - Metals and Volatile Organic Compounds March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 SW-7 18-Mar-11 30.91 0.9761 0.1881 0.521 SW-7 1-Nov-11 26.31 1.191 1111111LB 1.99JB SW-7 26-Apr-12 23.41 1.631 SW-7 24-Oct-12 26.21 SW-7 18-Apr-13 30J 0.4BJ 0.41 0.7J 0.5J 0.361 SW-7 17-Oct-13 0.91 30J 0.51 0.41 0.6J 0.3J 0.481 SW-7 15-Apr-14 0.61 30J 1.01 0.41 4J 0.71 0.81 61 8131 SW-7 12-Nov-14 30J 0.41 0.21 0.51 0.481 SW-7 29-Apr-15 30J 0.31 0.31 0.91 21 111 0.341 SW-7 15-Oct-15 30J 0.31 0.21 0.41 0.3116 SW-7 21-Apr-16 30J 0.41 0.61 SW-7 14-Sep-16 0.271 24J 0.7316 2.71 3.91B SW-7 20-Apr-17 29J 0.961 SW-7 20-Sep-17 22J 0.781 2.91 SW-7 11-Apr-18 27J 1.51 SW-7 23-Oct-18 25J SW-7 24-Apr-19 27J 1.31 SW-7 7-Nov-19 25 0.12131 3.41 4.51 SW-7 9-Apr-20 30 1.51 2.81 120 SW-7 14-Oct-20 27 SW-7 31-Mar-21 27 1.41 SW-8 18-Mar-11 28J 0.9471 0.1281 SW-8 1-Nov-11 24.81 1.101 5.18.113 SW-8 26-Apr-12 3.671 21.71 1.791 1.541 SW-8 24-Oct-12 4.221 24.31 SW-8 18-Apr-13 30J 0.41 0.2.1 0.71 SW-8 17-Oct-13 30J 0.21 0.51 SW-8 15-Apr-14 1.01 30J 1.1 0.51 41 0.81 0.81 61 7JB SW-8 12-Nov-14 30J 6.1 0.21 0.5.1 SW-8 29-Apr-15 0.71 20J 0.31 0.2.1 0.61 9.01 0.521 SW-8 is-Oct-15 30J 0.31 0.2.1 0.41 0.2416 SW-8 20-Apr-16 30J 0.51 0.2.1 0.61 SW-8 12-Sep-16 26J 0.26.1 0.57.113 3.11 2.31 SW-8 20-Apr-17 26J 0.731 SW-8 20-Sep-17 21J 0.721 SW-8 11-Apr-18 27J 1.51 SW-8 23-Oct-18 23J SW-8 24-Apr-19 27J SW-8 7-Nov-19 25 0.094131 5.31 SW-8 9-Apr-20 29 15 2.91 4.11 SW-8 14-Oct-20 27 SW-8 31-Mar-21 1 1 27 Notes: 1. All units are in micrograms per liter (parts per billion). 2. Izl - A Standard for total chromium has not been established. The value provided is for chromium (III). 3. NS - No Standard 4. * - North Carolina In -Stream Target Value 5.1 - Indicates the analytical result is an estimated concentration between the method detection limit and the limit of quantitation. 6. B - The analyte concentration detected in the method blank was greater than the method detection limit. Concentration exceeds the North Carolina 15A NCAC 02B or In -Stream Target Value Freshwater Aquatic Life Standard for Class C Waters -June 2019 Indicates the result is below the detection limit. Smith Page 23 of 23 June 2021 Table 5 Constiuents Exceeding Standards March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 UpperMonitoring March 2021 Parameters Exceeding the North Carolina 2L, March 2021 Parameters Exceeding the North Carolina 2L, Facility Permit Number Interim Maximum Allowable Concentration, or Upper Well Code Tolerance Limit Well Code Tolerance Limit 9209-MSWLF-1984 MW-11 None Detected MW-28 None Detected 9209-MSWLF-1984 MW-11d None Detected MW-28d None Detected 9209-MSWLF-1984 MW-SR Cobalt** MW-29d None Detected 9209-MSWLF-1984 MW-6 Cobalt**, 1,4-Dioxane MW-30 Chromium 9209-MSWLF-1984 MW-6d None Detected MW-31 Chromium 9209-MSWLF-1984 MW-7 Cobalt**, Benzene MW-31d None Detected 9209-MSWLF-1984 MW-8 Chromium MW-32 None Detected 9209-MSWLF-1984 MW-8d None Detected TB-1a Cadmium 9209-MSWLF-1984 MW-9 Cadmium, 1,4-Dichlorobenzene, 1,4-Dioxane, Vinyl Chloride TB-1a deep None Detected 9209-MSWLF-1984 MW-10 Chromium MW-33 None Detected 9209-MSWLF-1984 MW-10d Antimony* MW-34 Chromium, Cobalt**, 1,1-Dichloroethane, Tetrachloroethene 9209-MSWLF-1984 MW-22 Cobalt** MW-34d Cadmium 9209-MSWLF-1984 MW-23 None Detected MW-35 None Detected 9209-MSWLF-1984 MW-23d None Detected MW-36 Chromium 9209-MSWLF-1984 MW-24 None Detected MW-36d Chromium Notes: 1. * - Interim Maximum Allowable Concentration 2. ** - Upper Tolerance Limit - Calculated as part of the North Wake Unlined Alternate Source Demonstration and were approved by the Solid Waste Section on August 17, 2020. 3. Bold - Indicates a J flag detection in which the analytical result is an estimated concentration between the method detection limit and the limit of quantitation. Smith Page 1 of 1 June 2021 Table 6 Geochemical Data March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - 9209-MSWLF-1984 11 16-Mar-11 141.9 5.94 1.89 <2 E <10 o -- 1.60 <2 <2 -- - 3.8JB 0.53J 0.92J 250D 8.3J <0.1 164 <0.05 <0.5 <0.5 <0.5 <0.5 <0.5 o o ol 2.7 MW-5R MW-5R 31-Oct-11 156.8 5.71 0.75 <2 <10 -- 3.88 <2 <3 -- - 2.7JB 12.0 1.4 IIOD 3.9J <0.1 335 D 0.140 0.51 <0.07 0.111 <0.07 <0.07 1.9 MW-5R 24-Apr-12 192.5 5.72 1.48 <2 <10 -- <0.43 <0.2 <0.54 -- - 2.2J 10.0 1.1 110 3.41 <0.01 321D <0.046 <0.D4 <0.24 <0.87 <0.62 <0.048 <0.057 <0.061 2.4 MW-5R 22-Oct-12 96.1 6.20 2.22 <2 13 -- 1.64 <0.2 <0.54 -- - 3.1JB 4.3J 1.4 190 5J <0.01 375D <0.046 <0.031 <0.031 <0.078 <0.095 <0.052 <0.063 <0.01 9.1 MW-5R 17-Apr-13 110.1 6.46 0.73 <4 <16 -- 0.31J <0.061 <0.069 -- -- 1.4 9.07 1.4 135 2.11 <0.4 180 0* <0.5 <1 <0.5 <0.5 <0.25 0.38J MW-5R 16-Oct-13 132.5 6.08 1.88 <4 <16 -- 2.3 <0.061 <0.069 -- - 1.70 9.90 1.1 184 2.98 <0.4 210B 0.2* <0.5 <1 <0.5 <0.5 <0.25 0.82 MW-5R 16-Apr-14 139.7 5.48 3.09 (1) <16 -- <1.3 <0.61 <0.069 -- -- 1.4 9.35 0.7J 11.5 1.3 <0.4 180 0* <0.5 <1 <0.5 <0.5 <0.25 1.2 MW-5R 12-Nov-14 -116.7 6.74 1.41 (1) <16 -- 1.I1 <0.61 <0.069 -- - 2.1 6.25 <0.09 211 2.9B 0.4JB 130 0* <0.5 <1 <0.5 <0.5 <0.25 11 MW-5R 30-Apr-15 14.4 5.39 2.41 <2 <16 -- <0.30 <0.61 <0.069 -- -- 1.6 8.00 0.9J 62.1 1.5 <0.4 120 0* <0.5 <1 <0.5 <0.5 <0.25 2.8 MW-5R 15-Oct-15 156.1 6.38 2.12 <2.0 <16 -- 1.9 <0.061 <0.069 -- - 2.8 0.137 1.0 272 9.5 0.5J 110 0* <0.50 <1.0 <0.50 <0.50 <0.020 2.4 MW-5R 21-Apr-16 116.7 5.54 1.36 <2.0 <16 -- <0.30 <0.061 <0.069 -- -- 1.6 3.65 0.9J 39.1 1.1 <0.4 110 0.5* <0.50 <1.0 <0.50 <0.50 <0.020 14.0 MW-5R 14-Sep-16 109.2 5.88 1.99 <2.0 <10 -- 4.2J <10 <10 -- - 2.6 1.8 0.56J 220 3.4B <1.0 430 0.5* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 3.9 MW-5R 20-Apr-17 94.2 6.29 1.30 <2.0 <10 -- 3.6 <10 <10 -- -- 2.6 1.6 1.1 200 1.1 <1.0 350 0* <1.0 <1.0 <2.0 <2.0 <1.0 <1.0 <1.0 1.6 MW-5R 20-Sep-17 -29.0 6.60 2.58 <2.0 55 -- 4,IOOD <10 <10 -- - 220D 0.23 0.67 350 11D <2.5 990 5.0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 0.26 3.0 MW-5R 11-Apr-18 40.9 5.90 1.56 <2.0 <10 -- <10 <10 <10 -- -- 2.5 3.6 0.96J 100B 2.2 <1.0 130 0* <.0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 2.7 MW-5R 24-Oct-18 52.8 6.33 0.24 <2.0 <20 -- IIB <10 <10 -- - 4.6 0.064 1.6 260 2.6 <1.0 300 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 4.6 MW-5R 22-Apr-19 179.2 4.83 2.27 <2.0 <20 -- <10 <10 <10 -- - 1.8 5.1 <1.0 <20 0.54J <1.0 71 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 <1.0 MW-5R 6-Nov-19 229.2 6.11 1.98 <2.0 <20 -- 17B <10 <10 -- 8,900 6.6 0.23 1.1 120 4.4 <1.0 470 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 2.5 MW-5R 4-Feb-20 179.2 4.83 2.27 -- 13,000C 2,300 1,700D <50 <50 30,000 6,300 - 0.23 - 150 <1.0 -- 4,500 2.5* 520.0 49.0 6.5 3.7 4.3 230.0 1.0 -- MW-5R 8-Apr-20 37.1 5.26 0.82 >8i" 2,800D 860 3100 <10 <10 85,000 6,300 4.9 <0.020 760D 410 <1.0 1.1 4,000 2.5* 760d" "" 87d B.Sd <0.20 23d 210d 7.6d 12 MW-5R 30-Jul-20 -55.9 6.04 1.21 1,200D 1,200D 930 8,500D <50 <50 120,000 6,900 - <0.020 - - <1.0 -- 1,100 3.0* 250.0 34.0 9.8 <5.0 5.6 38.0 7.3 -- MW-5R 15-Oct-20 -28.2 6.16 0.53 >100(n) 920 730 4,400BD <10 <10 120,000 7,600 8.4JD 0.12BJD 210D 390 <10 <1.0 970 5.0* 180.0 7.7J <1.2 <1.1 <1.1 7.7J <1.2 33 MW-5R 31-Mar-21 -76.2 6.16 0.13 10014' 280 290 7,000BD <10 <10 84,000 5,000 3.41D 0.027JD 58 270 <5.0 <1.0 750 4.5* 63 <0.58 <0.58 <0.53 <0.56 4.3J <0.60 2.9 MW-6 16-Mar-11 25.3 5.89 2.48 <2 75 -- 899 <2 <2 -- - 140BD 0.029J 14 500D 6.3J <0.1 349D 0.77 <0.5 <0.5 <0.5 18 <0.5 2.2 MW-6 1-Nov-11 10.6 6.09 1.34 <2 94 -- 4,600 <2 <3 -- -- 170BD 0.053J 22 600D 12J <0.1 820D 1.50 <0.07 8.7 <0.14 34 <0.07 1.9 MW-6 24-Apr-12 168.6 5.85 2.14 <2 32 -- 5,660D <0.2 <0.54 -- - 97 0.25J 4.4 190D 3.5J <0.01 549D <0.046 <0.04 <0.24 <0.87 <0.62 0.56 1.7 <0.061 2.6 MW-6 22-Oct-12 -134.6 6.34 4.33 <2 100 -- 732D <0.2 <0.54 -- -- 160BD <0.025 21 430D 11J 0.029 725D 3.6 <0.031 <0.031 <0.078 26 <0.052 30 <0.01 5.9 MW-6 17-Apr-13 -158.3 6.25 0.91 <4 <16 -- 16 <0.061 <0.069 -- - 54.4 0.18J 3.5 105 2.82 <0.4 110 1.4* <0.5 <1 <0.5 <0.5 <0.25 0.76 MW-6 16-Oct-13 12.9 6.32 1.81 <4 40 -- 45 <0.061 <0.069 -- -- 93 0.161 5.2 136 2.63 <0.4 98B 5.4* <0.5 <1 <0.5 <0.5 <0.25 0.93 MW-6 16-Apr-14 43.1 5.99 1.81 (1) <16 -- 51 <0.061 <0.069 -- - 40.3 0.42 1.6 40.2 1.5 <0.4 69 0.5* <0.5 <1 <0.5 <0.5 <0.25 1.3 MW-6 12-Nov-14 -121.4 6.81 0.87 (1) 74 -- 1,400 <0.061 <0.069 -- -- 184 0.091 14.4 607 47.3 <0.4 180 1.5* <0.5 <1 <0.5 <0.5 <0.25 7.3 MW-6 30-Apr-15 -52.3 6.05 2.01 <2 <16 -- 23 <0.061 <0.069 -- - 50.9 0.16J 2.6 192 5.9 <0.4 95 0.5* <0.5 <1 <0.5 <0.5 <0.25 2.5 MW-6 14-Oct-15 58.9 6.68 2.39 <2.0 60 -- 0.62J <0.061 <0.069 -- -- 208 0.017 14.7 422 19.7 0.4 UX 87 0* 2.1 <1.0 <0.50 <0.50 <0.020 2.4 MW-6 20-Apr-16 38.7 6.53 1.53 <2.0 <12 -- 0.32J <0.061 <0.069 -- - 58.5 0.37 2.3 164 4.1 <0.4 62 1.5* <0.50 <1.0 <0.50 <0.50 0.15J 12 MW-6 14-Sep-16 11.0 6.42 1.40 <2.0 44 -- 3.7J <10 <10 -- -- 210D 0.037 11 390 13D <1.0 470 1.5* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 3.8 MW-6 20-Apr-17 119.3 6.70 2.16 <2.0 22 -- 4.2J <10 <10 -- - 110 0.46 6.4 250 11 <3.0 350 0* <1.0 <1.0 <2.0 <2.0 <1.0 <1.0 <1.0 22 MW-6 21-Sep-17 -59.0 7.54 2.87 <2.0 31 -- <10 <10 <10 -- -- 140 0.069 10 430 19 <1.0 520 2.0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 3.4 MW-6 12-Apr-18 13.0 6.34 1.74 <2.0 15 -- 140 <10 <10 -- - <10 1.5 5.1 140B 5.5 <1.0 150 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 3.6 MW-6 24-Oct-18 49.6 6.64 0.60 3.6 37 -- 1,900B <10 <10 -- -- 160 <0.020 12 590 20 <1.0 590 1.0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 10 MW-6 22-Apr-19 100.4 6.12 0.51 5.3 <20 -- 1,800 <10 <10 -- - 74 1.5 2.8 220 4.1 <1.0 450 1.0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 <3.0 MW-6 6-Nov-19 39.3 6.38 1.11 <2.0 33 -- 56B <10 <10 -- -- 180 0.48HD 14 410 7.7 <1.0 750 1.0* <0.10 <0.10 0.76 <0.10 <0.10 <0.10 <0.10 3.0 MW-6 7-Apr-20 79.2 5.85 3.66 <2.0 <20 -- 42B <30 <10 -- - 78 0.57 2.5 150 5.4 <1.0 220 0.5* <0.10 <0.10 <0.20 <0.10 <0.10 <0.10 <0.10 4.3 MW-6 15-Oct-20 -29.1 6.06 2.08 <2.0 22 -- 260 <10 <10 -- - 120D 1.8BD 7.6 210 7.6JD <1.0 350 2.0* 3.2J <0.58 <0.58 <0.53 <0.56 0.54J <0.60 <0.49 MW-6 I 31-Ma,211 117.4 5.431 1.75 <2.0 <20 1 100 <10 <10 68 0.92 2.7 140 3.7 <3.0 350 0* 0.24J <0.058 <0.056 <0.053 <0.056 <0.053 <0.060 <0.98 MW-8 16-Mar-11 208.4 5.49 1.28 <2 <10 -- 600 <2 <2 -- - 9.5B 0.121 <1 68 2.8J <0.1 148 <0.05 <0.5 <0.5 <0.5 <0.5 <0.5 2.2 MW-8 31-Oct-11 138.1 5.61 0.65 <2 11 -- 1,750 <2 <3 -- - 7.8B 0.12J 0.84J 68 2.5J <0.1 273D 0.130 0.99 <0.07 <0.14 0.33 <0.07 1.7 MW-8 24-Apr-12 161.7 5.64 1.67 <2 <10 -- 1,870D <0.2 <0.54 -- -- 12 0.191 0.95J 74 2.6J <0.01 324D <0.046 <0.04 <0.24 <0.87 <0.62 <0.048 <0.057 <0.061 2.0 MW-8 22-Oct-12 128.4 5.86 2.11 <2 QO -- 477D <0.2 <0.54 -- - 14B 0.32J 0.820J 77 3.1J <0.01 323D <0.046 <0.031 <0.031 <0.078 1.1 <0.052 <0.063 0.01J 9.8 MW-8 17-Apr-13 96.8 6.23 0.48 <4 <16 -- 520 0.141 O.1J -- -- 16.9 0.2J 1.4 86.8 1.49 <0.4 180 0.9* <0.5 <1 <0.5 <0.5 <0.25 0.72 MW-8 16-Oct-13 146.8 5.79 1.74 <4 <16 -- 430 0.11J <0.069 -- - 19.7 0.18J 1.5 86.8 1.57 <0.4 200B 0.8* <0.5 <1 <0.5 <0.5 <0.25 0.85 MW-8 16-Apr-14 122.9 5.79 0.19 (1) <16 -- 180 <0.60 <0.069 -- -- 23.7 0.181 1.3 87.7 1.7 <0.4 230 0* <0.5 <1 <0.5 <0.5 <0.25 1.4 MW-8 12-Nov-14 -84.6 6.09 0.79 (1) 20 -- 320 0.13J 0.17J -- - 29.4 0.12J 1.5 95.5 2.2B 0.4JB 160 0* <0.5 <1 <0.5 <0.5 <0.25 17 MW-8 30-Apr-15 22.5 5.62 1.85 <2 17J -- 160 <0.061 0.11J -- -- 44.0 O.11J 2.8 132 2.5 <0.4 180 0* <0.5 <1 <0.5 <0.5 <0.25 4.1 MW-8 15-Oct-15 113.1 5.93 1.63 <2.0 17J -- 150 <0.061 <0.069 -- - 44.9 0.007J 2.3 114 4.2 0.5J 130 0* 0.681 <1.0 <0.50 <0.50 <0.020 2.0 MW-8 21-Apr-16 81.5 5.99 1.86 <2.0 <12 -- 110 <0.061 <0.069 -- - 39.6 <0.04 2.6 123 2.4 <0.4 150 0* <0.50 <1.0 <0.50 <0.50 <0.020 15 MW-8 14-Sep-16 116.9 5.75 1.77 <2.0 6.7J -- 640 <10 <10 -- - 45 0.021 1.9 120 2.38 <1.0 370 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 3.8 MW-8 20-Apr-17 113.7 5.97 1.25 <2.0 8.3J -- 180 <10 <10 -- - 37 0.069 1.8 110 0.98J <1.0 300 0* <1.0 <1.0 <2.0 <2.0 <1.0 <1.0 <1.0 1.6 MW-8 20-Sep-17 154.0 6.41 1.78 <2.0 9.3 -- 150 <10 <10 -- - 44 0.055 2.4 120 1.5 <1.0 320 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 4.4 MW-8 12-Apr-18 25.6 5.79 1.21 2.2 <10 -- 150 <10 <10 -- - 45 0.035 2.2 140B 1.2 <1.0 150 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 2.8 MW-8 24-Oct-18 68.9 5.87 0.10 <2.0 <20 -- 200B <10 <10 -- - 49 <0.020 2.8 130 2.2 <1.0 180 0.5* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 3.4 MW-8 22-Apr-19 55.7 5.94 1.29 <4.0 <20 -- 350 <10 <10 -- - 78 0.042 5.1 170 1.6 <1.0 770 1.0* <0.10 0.10 <0.20 <0.20 <0.10 <0.10 <0.10 <1.0 MW-8 6-Nov-19 116.9 6.07 0.49 <2.0 71 -- 410B <10 <10 -- - 29 0.016J 3.6 110 2.0 <1.0 340 0.5* 0.14 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 1.5 MW-8 7-Apr-20 68.9 5.84 3.80 <2.0 <20 -- 76 <10 <10 -- - 43 0.028 1.8 130 2.1 <1.0 170 1.0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 2.1 MW-8 15-Oct-20 -19.3 5.86 0.49 <2.0 <20 -- 590 <10 <10 -- - 81 <0.020 5.1 150 1.2 <1.0 240 1.5* 0.35J <0.058 <0.058 <0.053 <0.056 <0.053 <0.060 0.49J MW-8 31-Mar-21 58.0 5.75 0.23 <2.0 <20 150 <10 <10 130 <0.10 3.4 210 1 1.0 1 <1.0 280 1.0* 1.7J <0.29 <0.29 <0.26 <0.28 <0.26 <0.30 2.1 Smith Page 1 of 3 June 2021 Table 6 Geochemical Data March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - 9209-MSWLF-1984 17-Mar-11 2.4 5.78 2.29 3 68 o -- 438 2.27 <2 -- -- 18B 0.11 5.8 220D 2.7J <0.1 231D 7.7 <0.5 <0.5 <0.5 1.8 <0.5 o o ol -- MW-9 MW-9 1-Nov-11 6.3 5.95 1.94 <2 53 -- 1,080 <2 <3 -- - 15B 0.075J 4.4 210D 2.9J <0.1 414D 1.3 0.86 <0.07 <0.14 1.5 <0.07 -- MW-9 25-Apr-12 94.8 5.95 3.11 5.4 34 -- 2,810D <0.2 1.59J -- - 18 0.079J 6.1 250D 2.8J <0.01 503D 7.8 <0.D4 <0.24 <0.87 <0.62 <0.048 1.7 <0.061 -- MW-9 23-Oct-12 83.4 6.72 8.77 <2 61 -- 5.47 <0.2 <0.54 -- - 17B <0.025 3.2 120 8.8J <0.01 16.6 <0.230 <0.031 <0.031 <0.078 <0.095 <0.052 0.840 0.017 -- MW-9 17-Apr-13 91.3 6.88 6.84 3.1 22 -- 8.5 <0.061 <0.069 -- -- 17.1 <0.03 3.5 130 7.42 <0.4 10 2.1* <0.5 <1 <0.5 <0.5 <0.25 -- MW-9 16-Oct-13 165.7 6.88 7.89 <4 28 -- 0.53J <0.061 <0.069 -- - 20.4 0.17J 2.9 117 5.60 <0.4 27B 0* <0.5 <1 <0.5 <0.5 <0.25 -- MW-9 16-Apr-14 160.2 6.44 3.69 (1) 17J -- 17 <0.061 <0.069 -- -- 18.5 0.151 3.1 127 4.8 <0.4 39 0* <0.5 <1 <0.5 <0.5 <0.25 -- MW-9 12-Nov-14 33.5 6.80 5.67 (1) 30 -- 1.8 <0.061 <0.069 -- - 22.7 0.10J <0.09 136 3.9B 0.418 28 0* <0.5 <1 <0.5 <0.5 <0.25 -- MW-9 29-Apr-15 20.6 6.57 9.69 2.8 17J -- 2.9 <0.061 <0.069 -- -- 19.2 <0.03 3.8 156 3.6 <0.4 27 0* <0.5 <1 <0.5 <0.5 <0.25 -- MW-9 15-Oct-15 132.2 6.65 4.66 6.5 <16 -- <0.30 <0.061 <0.069 -- - 25.4 0.040 2.0 171 5.4 <0.4 53 0* <0.50 <1.0 <0.50 <0.50 <0.020 -- MW-9 20-Apr-15 75.9 6.81 5.40 <2.0 <12 -- 7.8 <0.061 <0.069 -- -- 18.2 0.051 1.7 182 3.4 <0.4 46 0* <0.50 <1.0 <0.50 <0.50 <0.020 -- MW-9 13-Sep-16 151.7 6.72 7.15 <4.0 8.01 -- - - - -- - 25 0.052 1.6 200 3.8 <I.0 - 1.0* - - - - - -- MW-9 19-Apr-17 130.8 6.93 7.28 <2.0 <10 -- 6.1BJ <10 <10 -- -- 24 0.00961 1.8 210 2.1 <1.0 240 1.0* <1.0 <1.0 <2.0 <2.0 <1.0 <1.0 <1.0 -- MW-9 21-Sep-17 140.0 7.57 6.01 <2.0 <10 -- <10 <10 <10 -- - 24 0.056 1.9 200 2.8 <1.0 220 1.0* <0.10 <0.30 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-9 11-Apr-18 41.4 6.79 7.50 <2.0 <10 -- <10 <10 <10 -- -- 23 0.080 1.8 190B 2.2 <1.0 180 1.5* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-9 25-Oct-18 51.1 7.07 8.83 2.6 <20 -- 6.9B1 <10 <10 -- - 22 <0.020 2.2 210 2.5 1.5 190 0* <0.10 <0.30 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-9 25-Apr-19 102.7 6.46 1.63 <2.0 <20 -- 1,500 <10 <10 -- -- 11 <0.020 3.7 270 1.4 <1.0 680 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-9 5-Nov-19 105.4 6.50 1.55 <2.0 <20 -- 530B <10 <10 -- - 30 <0.10 3.5 370 2.7 <1.0 990 0* <0.10 <0.30 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-9 7-Apr-20 37.1 6.11 0.86 2.41" <20 -- 1,800E <10 <10 -- -- 31 0.00791 4.4 430 3.2 <1.0 570 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-9 15-Oct-20 -36.7 6.12 0.76 7.4" " 21 -- 1,400 <10 <10 -- - 41 <0.020 6.0 440 2.0 <1.0 570 0* 0.5 <0.058 0.11J 0.060J <0.056 0.0661 <0.060 -- MW-9 I 31-Mar-21 -4.4 6.011 0.19 4.3"" 36 1 1,800 <10 <10 45 <0.10 9.4 490 0.61J <1.0 820 0* 0.27J 0.141 1 <0.058 <0.053 <0.056 <0.053 <0.060 MW-10 17-Mar-11 119.7 5.29 3.18 <2 <10 -- 2,000 <2 <2 -- - 4.3JB 0.039J 2.7 130 2.41 <0.1 399D 0.26 <0.5 <0.5 <0.5 <0.5 <0.5 -- MW-10 31-Oct-11 120.1 5.41 2.12 <2 15 -- 9,630 <2 <3 -- -- 3.6JB <0.1 1.1 130 2A <0.1 777D 0.47 0.99 <0.07 0.12J 0.22 <0.07 -- MW-10 25-Apr-12 127.9 5.41 2.62 <2 10 -- 10,300D <0.2 <0.54 -- - 3.5J <0.025 3.3 120 3.1J <0.01 832D 0.17 0.26 <0.24 0.59 0.17 <0.048 <0.057 <0.061 -- MW-10 23-Oct-12 99.2 5.68 2.94 <2 28 -- 8,220D <0.2 <0.54 -- -- 3.7JB <0.025 3.6 120 2A <0.01 646D 0.083 0.087 <0.031 <0.078 <0.095 <0.052 <0.063 0.011J -- MW-10 17-Apr-13 113.9 6.08 2.93 <4 <16 -- 920 <0.061 <0.069 -- - 2.71 <0.03 1.5 132 0.75 <0.4 370 1.4* <0.5 <1 <0.5 <0.5 <0.25 -- MW-10 16-Oct-13 84.8 5.65 4.05 <4 191 -- 3,100 <0.061 <0.069 -- -- 2.74 <0.03 0.9J 117 0.73 <0.4 300B 1.8* <0.5 <1 <0.5 <0.5 <0.25 -- MW-10 16-Apr-14 68.9 5.71 3.11 (1) <16 -- 3,200 <0.061 <0.069 -- - 3.4 <0.03 2.3 129 0.7J <0.4 400 1.5* <0.5 <1 <0.5 <0.5 <0.25 -- MW-10 12-Nov-14 10.9 5.84 1.81 (1) 27 -- 3,900 0.094J 0.11J -- -- 3.0 <0.03 2.5 147 1.18 <0.4 360 2.0* <0.5 <1 <0.5 <0.5 <0.25 -- MW-10 29-Apr-15 30.6 5.56 2.82 3.1 <16 -- 1,300 <0.061 <0.069 -- - 3.4 <0.03 3.0 184 0.9J <0.4 320 2.0* <0.5 <1 <0.5 <0.5 <0.25 -- MW-10 14-Oct-15 89.3 5.74 2.44 5.6 <16 -- 1,200 <0.061 <0.069 -- -- 3.3 <0.002 1.0 140 <1.8 <0.4 250 1.5* 0.67J <1.0 <0.050 <0.50 <0.020 -- MW-10 20-Apr-16 30.9 5.79 2.34 6.5 161 -- 1,200 <0.061 <0.069 -- - 3.4 <0.04 1.6 128 <0.06 <0.4 200 1.0* 0.57J <1.0 <0.20 <0.50 <0.020 -- MW-10 13-Sep-16 28.2 5.44 1.61 4.3 10 -- - - - -- -- 3.6 0.024 <1.0 160 <1.0 <1.0 - 4.5* - - - - - -- MW-10 19-Apr-17 125.9 5.74 3.39 8.3 QO -- 4,800B <10 <10 -- - 3.6 0.014J 1.2 160 <1.0 <1.0 720 3.0* <1.0 <1.0 <2.0 <2.0 <1.0 <1.0 <1.0 -- MW-10 22-Sep-17 118.0 6.20 1.90 <2.0 <10 -- 1,100 <10 <10 -- -- 3.0 0.017 1.9 110 <1.0 <1.0 440 3.0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-10 11-Apr-18 44.1 5.60 0.71 <2.0 9.4J -- 750 <30 <10 -- - 3.0 0.089 0.9 88B 0.43J <1.0 140 2.5* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-10 25-Oct-18 74.0 5.61 3.64 5.5 <20 -- 3,200 <10 <10 -- -- 3.2 <0.020 1.3 120 <1.0 <1.0 450 3.5* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-10 25-Apr-19 7.9 5.47 0.39 5.1, 1 <20 -- 4,200D <10 <10 -- - 3.9 <0.020 2.9 130 <3.0 <3.0 1,300 3.0* 0,34 <0.10 <0.20 <0.20 <0.10 <0.30 <0.30 -- MW-10 5-Nov-19 44.3 5.85 0.80 5.4 <20 -- 4,300BD <10 <10 -- -- 3.5 0.016J 1.2 120 0.49J <1.0 770 3.0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-10 7-Apr-20 22.3 5.50 0.42 4.8"" <20 -- 3,300D <10 <10 -- - 3.8 0.017J 1.5 120 <1.0 <1.0 350 2.5* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-10 15-Oct-20 -33.9 5.64 2.61 3.8'n) <20 -- 1,600 <10 <10 -- - 3.3 0.032B <1.0 88 <1.0 <1.0 210 3.0* 0.37J <0.058 <0.058 <0.053 <0.056 <0.053 <0.060 -- MW-10 31-Mar-21 167.3 5.11 0.19 <2.0 <20 18 <10 <10 3.1 2.0 2.1 27 0.32J <1.0 220 2.5* 0.22J <0.058 <0.058 <0.053 <0.056 <0.053 <0.060 MW-11 17-Mar-11 211.2 5.21 8.02 <2 17 -- 0.521 <2 <2 -- - 5B 0.6J 0.53J 32 2.1J <0.1 67.6 <0.05 <0.5 <0.5 <0.5 <0.5 <0.5 -- MW-11 1-Nov-11 161.6 5.62 5.89 3.20 QO -- <1 <2 <3 -- - 4.1JB 0.71J 0.35J 25 2.21 <0.1 164 <0.05 0.8 <0.07 0.0771 0.16 <0.07 -- MW-11 25-Apr-12 112.2 5.47 6.22 <2 <10 -- <0.43 <0.2 <0.54 -- -- 3.1J 0.086J 0.76J 22 1.7J <0.01 161D <0.046 <0.04 <0.24 <0.87 0.13J <0.048 <0.057 <0.061 -- MW-11 23-Oct-12 237.1 5.82 7.22 <2 13 -- <0.43 <0.2 <0.54 -- - 3.7JB 0.150J 1.5 27 2.1J <0.01 147D <0.046 <0.031 <0.031 <0.078 <0.095 <0.052 <0.063 <0.01 -- MW-11 17-Apr-13 102.3 5.94 5.73 <4 <16 -- <0.30 <0.061 <0.069 -- -- 2.62 0.23 1.1 33.1 0.69 <0.4 100 0.8* <0.5 <1 <0.5 <0.5 <0.25 -- MW-11 16-Oct-13 211.6 5.49 7.84 <4 <16 -- <0.30 <0.061 <0.069 -- - 3.16 0.26 0.7J 34.8 0.66 <0.4 82B 0.4* <0.5 <1 <0.5 <0.5 <0.25 -- MW-11 16-Apr-14 198.8 5.62 5.63 (1) 34 -- 0.59 <0.061 <0.069 -- -- 3.4 0.36 0.5J 38.9 0.71 <0.4 110 0* <0.5 <1 <0.5 <0.5 <0.25 -- MW-11 12-Nov-14 116.3 5.80 4.68 (1) 57 -- <0.30 <0.061 <0.069 -- - 4.1 0.46 0.8J 36.4 0.91B 0.5JB 82 0* <0.5 <1 <0.5 <0.5 <0.25 -- MW-11 30-Apr-15 20.1 5.52 7.18 <2 <16 -- <0.30 <0.061 <0.069 -- -- 3.9 0.43 0.9J 35.8 0.9JB <0.4 82 0* <0.5 <1 <0.5 <0.5 <0.25 -- MW-11 15-Oct-15 196.8 5.91 5.70 <2.0 <16 -- <0.30 <0.061 <0.069 -- - 3.6 0.480 0.3J 34.9 <1.8 <0.4 66 0* <0.50 <1.0 <0.50 <0.50 <0.020 -- MW-11 21-Apr-16 135.3 5.72 5.75 <2.0 <12 -- <0.30 <0.061 <0.069 -- -- 4.0 0.53 0.5J 33.9 0.71 0.5JB 75 1.5* <0.50 <1.0 <0.50 <0.50 <0.020 -- MW-11 1-Sep-16 149.9 5.56 6.49 15 <10 -- - - - -- - 5.1 0.81 <1.0 42 <1.0 <1.0 - 1.5* - - - - - - MW-11 20-Apr-17 142.3 5.87 4.82 <2.0 <10 -- 2.7J <10 <10 -- - 4.8 0.89 <1.0 36 <1.0 <1.0 150.0 0.5* <1.0 <1.0 <2.0 <2.0 <1.0 <1.0 <1.0 -- MW-11 22-Sep-17 244.0 6.39 4.55 <2.0 <10 -- <10 <10 <10 -- - 5.2 0.88 <1.0 47 <3.0 <1.0 130 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 - MW-11 13-Apr-18 46.3 5.71 5.74 <2.0 <10 -- <10 <10 <10 -- - 5.4 0.89 <1.0 46B 0.27J <1.0 75 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-11 25-Oct-18 44.6 6.02 5.97 <2.0 <20 -- 2.5BJ <10 <10 -- - 5.9 0.95 <S.0 46 <1.0 <1.0 82 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 - MW-11 25-Apr-19 87.8 5.91 5.94 3.4,1 <20 -- <10 <10 <10 -- - 5.8 0.94 1.9 49 <1.0 <1.0 170 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-11 5-Nov-19 183.2 6.16 6.46 2.1 <20 -- <10 <10 <30 -- - 5.5 0.90 <1.0 42 0.26J <1.0 230 0* 0.51 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 - MW-11 8-Apr-20 144.7 5.88 6.44 6.2"" <20 -- 3.2J <10 <10 -- - 5.7 0.94 <1.0 44 0.31J <1.0 100 0* 0.16117, <0.10 <0.. <0.20 <0.10 <0.10 <0.10 -- MW-11 14-Oct-20 33.2 5.84 6.33 16"" <20 -- 2.SBJ <10 <10 -- - 5.7 0.88 <1.0 43 <1.0 <1.0 86 0* 0.43J <0.058 <0.058 <0.053 <0.061 <0.053 <0.060 - MW-11 31-Mar-21 132.4 5.57 6.58 <2.0 <20 42 <30 <30 5.6 0.787 <1.0 38 <1.0 <1.0 110 0* 0.501 <0.12 <0.12 <0.11 <0.11 <0.11 <0.12 - Smith Page 2 of 3 June 2021 Table 6 Geochemical Data March 2021 Semi -Annual Sampling Event North Wake Unlined Landfill - 9209-MSWLF-1984 11 6-Nov-19 195.8 5.63 1.52 <2.0 E <20 o -- 260B <10 <10 -- 7,300 11 0.14 1.0 35 0.47J <1.0 330 0* 0.12 0.29 <0.20 <0.20 <0.10 0.21 <0.10 o o ol -- MW-34 MW-34 4-Feb-20 157.2 5.15 1.25 -- <20 74 470 <10 <10 470 8,700 - 0.20 - 24 <1.0 -- 570 0* <0.10 <0.30 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-34 8-Apr-20 96.9 5.21 0.78 <2.0 <20 85 350 <10 <10 3,900 8,300 14 0.14 <1.0 40 0.50J 1.4 120 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-34 30-Jul-20 -13.4 5.30 0.18 -- <20 150 370 <10 <10 6,700 8,000 - 0.10 - - <1.0 -- 110 0* <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 -- MW-34 15-0ct-20 -22.1 5.29 0.91 <2.0 <20 99 300 <10 <10 610 8,200 14 0.091B <1.0 36 <1.0 <1.0 120 0* 0.43J <0.058 <0.058 <0.053 <0.056 <0.053 <0.060 -- MW-34 31-Mar-21 197.4 4.57 1.80 <2.0 <20 140 26 <10 <10 6,100 24,000 54 0.020 <3.0 <20 5.7 <I.0 190 0* 1.11 <0.29 <0.29 <0.26 <0.28 <0.26 <0.30 MW-34d 6-Nov-19 466.9 6.08 0.61 2.8 <20 -- 3.OBJ <10 <10 -- 12,000 9.2 1.0 1.6 65 1.4 <1.0 150 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-34d 4-Feb-20 347.9 5.88 0.28 -- <20 130 26 <10 <10 550 12,000 - 2.0 - 52 3.2 -- 550 0* <0.10 <0.30 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-34d 8-Apr-20 129.4 5.85 1.40 2.6i1 <20 120 3.01 <10 <10 110 13,000 10 1.0 1.2 70 1.8 <1.0 87 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-34d 30-Jul-20 -13.3 5.83 0.93 -- <20 120 2.8J <10 <10 120 12,000 - 1.7 - - 5.9 -- 100 0* <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 <0.50 -- MW-34d 15-Oct-20 -22.1 5.82 1.39 3.6i" 1 <20 150 4.01 <10 <10 86 14,000 11 1.313 <1.0 75 2.2 <1.0 88 0* 0.43J <0.058 <0.058 <0.053 <0.056 <0.053 <0.060 -- MW-34d I 31-Mar-211 223.4 5.461 0.35 <2.0 <20 1 110 1 6.7J <10 I <10 160 8,600 9.9 0.50 <I.0 1 59 1 1.2 <I.0 110 0* 0.27J <0.058 1 <0.058 <0.053 <0.056 <0.053 <0.060 MW-36 17-Mar-11 99.4 5.45 2.36 <2 38 -- 44 <2 <2 -- -- 7.213 0.67J 1.5 84 4.61 <O.1 140 <0.25 <0.5 <0.5 <0.5 <0.5 <0.5 -- MW-36 1-Nov-11 129.6 5.66 1.96 <2 36 -- 618 <2 <3 -- - 6.4B 0.51J 0.8J 62 4.4J <0.1 242D 0.052 0.99 <0.07 <0.14 0.21 <0.07 -- MW-36 25-Apr-12 122.2 5.71 2.84 5.2 29 -- 186D <0.2 <0.54 -- -- 5.9 0.5J 1.1 60 3.9J <0.01 336D <0.046 <0.04 <0.24 <0.87 0.073J <0.048 <0.057 <0.061 -- MW-36 23-Oct-12 139.1 5.92 8.39 <2 <10 -- 39.6 <0.2 <0.54 -- - 613 0.490J 1.7 67 3.9J <0.01 196D <0.046 <0.031 <0.031 <0.078 <0.095 <0.052 <0.063 <0.01 -- MW-36 17-Apr-13 118.1 6.05 2.44 12 <16 -- 6.4 <0.061 <0.069 -- -- 5.59 0.59 1.1 66.3 2.19 <0.4 98 0.8* <0.5 <1 <0.5 <0.5 <0.25 -- MW-36 16-Oct-13 188.5 5.82 3.89 <4 38 -- 9.8 <0.061 <0.069 -- - 5.50 0.73 1.1 59.2 2.19 <0.4 81B 1.5* <0.5 <1 <0.5 <0.5 <0.25 -- MW-36 16-Apr-14 165.3 5.76 3.08 (1) 71 -- 17 <0.061 <0.069 -- -- 5.8 0.86 0.6J 55.6 2.3 <0.4 110 0* <0.5 <1 <0.5 <0.5 <0.25 -- MW-36 12-Nov-14 96.2 5.76 2.23 (1) 37 -- 25 <0.061 <0.069 -- - 5.8 0.98 <0.09 55.3 2.6B <0.4 83 0* <0.5 <1 <0.5 <0.5 <0.25 -- MW-36 30-Apr-15 1.6 5.69 3.15 4.10 <16 -- 3.6 <0.061 <0.069 -- -- 5.8 0.89 1.4 58.4 2.3 <0.4 81 0* <0.5 <1 <0.5 <0.5 <0.25 -- MW-36 15-Oct-15 167.8 5.97 3.78 <2.0 33 -- 2.5 <0.061 <0.069 -- - 5.5 0.704 1.2 59.3 3.0 0.4J 72 0* <0.50 <1.0 <0.50 <0.50 <0.020 -- MW-36 20-Apr-16 125.4 5.80 2.49 <2.0 <12 -- 2.5 <0.061 <0.069 -- -- 5.9 0.60 1.0 53.7 2.3 <0.4 76 2.0* <0.50 <1.0 <0.50 <0.50 <0.020 -- MW-36 13-Sep-16 176.6 5.13 2.15 <2.0 <10 -- - - - -- - 6.7 0.81 <1.0 55 2.5 <1.0 - 0.5* - - - - - -- MW-36 20-Apr-17 143.0 5.79 1.77 <2.0 <10 -- 5.01 <10 <10 -- -- 6.9 0.79 0.70J 51 1.3 <1.0 190.0 2.0* <1.0 <1.0 <2.0 <2.0 <1.0 <1.0 <1.0 -- MW-36 22-Sep-17 143.0 6.00 1.95 <2.0 <10 -- 2.9 <10 <10 -- - 7.3 0.66 0.78 63 2.4 <1.0 220.0 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-36 13-Apr-18 45.2 5.81 1.35 <2.0 <10 -- <10 <10 <10 -- -- 6.9 0.66 0.83J 58B 3.3 <1.0 71.0 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-36 25-Oct-18 98.4 5.53 0.86 <2.0 20 -- 3.9BJ <10 <10 -- - 7.8 0.64 1.5 60 1.8 <1.0 190 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-36 25-Apr-19 123.4 5.77 0.94 <2.0 <20 -- <10 <10 <10 -- -- 8.9 0.62 1.0 61 2.3 <1.0 280 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-36 5-Nov-19 146.4 6.00 0.57 <2.0 <20 -- 4.5BJ <10 <10 -- - 8.8 0.60 1.0 58 1.9 1.1 390 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-36 7-Apr-20 63.9 5.69 0.74 <2.0 <20 -- 5.6BJ <10 <10 -- -- 9.1 0.57 <1.0 59 2.0 <1.0 120 0* <0.10 <0.10 <0.20 <0.20 <0.10 <0.10 <0.10 -- MW-36 15-Oct-20 -33.1 5.67 0.67 <2.0 <20 -- 5.5J <10 <10 -- - 9.6 0.40B <1.0 63 2.5 <1.0 150 0* 4.11 <0.58 <0.58 <0.53 <0.56 <0.53 <0.60 -- MW-36 31-Mar-21 125.19 5.22 1931.Q.0 QO 47 <10 <10 9.3 0.16 <1.0 56 2.9 1.3 140 0* 1.21 <0.29 <0.29 <0.26 <0.28 <0.26 <0.30 Note' 1. All units are in milligrams per liter ((mg/L) parts per million), unless otherwise noted. 2. pg/L- micrograms per liter (parts per billion) 3. CaCO3 - Calcium Carbonate 4. MW-11 is a background well for the North Wake Unlined Landfill. 5. * - Field analysis performed using a HACH kit. 6. (--) - Not Measured 7. J - Indicates the analytical result is an estimated concentration between the method detection limit and the limit of quantitation. 8. B -The analyte concentration detected in the method blank was greater than the method detection limit. 9. D, d - Analyzed as dilution. 10. UX -The compound was analyzed for, but not detected. 1 mL HNOs was added to MW-6 for metals upon receipt to get the pH to less than 2. 11. (1) - BOD was measured following dilution and did not meet the oxygen depletion criterion of at least 2 mg/L. The elevated BOD concentrations are a result of laboratory error and were not used to evaluate natural attenuation for the April and November 2014 sampling events. 12. 1-The average BOD for MW-9, -10, -36, and -11 is lower than the valid range. 13. (-)Sam ples not collected and analyzed for the spring 2016 sampling event. 14. H -The analyte was analyzed outside of holding time. 151'sl - 7 Bag -The seed correction factor was above the method range. Results maybe biased low. 16. I's1- 75 flag -The sample became depleted. The reported result was computed using the greatest dilution and the least amount of sample. 17. I171- M3 flag -The matrix spike duplicate sample recovery was outside laboratory control limits. 18. I'a1- M5 flag -The matrix spike sample recovery was outside laboratory control limits. 19. I's1-47 flag - Indicates a blank depletion less than 0.20 mg/L and a seed correction factor out of range. 20. I20I - 4 flag - The method blank result was higher than the method required limit of 0.20 mg/L. �- Blank cells indicate no data collected. Smith Page 3 of 3 June 2021 X1 w�E MW-28/. 221.05 s �7J V i J 4 221 52N i. MW-28cl 221.55 - SW-8 LEGEND Groundwater Monitoring Well Surface Water Sample Location • Injection Well Location Potentiometric Contour 218 — )dashed where inferred) Contour Interval = 2 Feet MW-10` 233.32 MW-9 MW-36l, L.� 228.94 N� '� �� 213.00 211.11 MW-36d t 211.16 ^ MW-29d I. �/ t t t t r, l ,� /`V 1. 235.04 Nti ' ' i i t 1� ,� , SW-7 M R,N ' , I ' 'N o co 1 1 y`. ', 1^"`'�. MW-6d N N � � *- 206.15 MW-30 N N N < < o MW 6 235.75 ) I N N N 208.08B,206 - r MW-23 231.65 / i r , r ��,,,, , '�Ma sad Unli�5ed �anafill r IMW-31d *' �� ' ' ' MW-35 U,231.42 ' ' 208.54 <� MW-31 - , r t NWIW-1 23ta7 BiI jnjectign I ' -ea = NWIW-z4MW-24 NWIW-3 Y.22.71t ' ` NWIW-4 MW-34 I'2 8 93� �. r NWIW-5 210.35 A`•. NWIW-6 MW-34d ` VV 210.09 TB-1a deep' ` - - f� NWIW-7 MW-5R 227.51 _ NWIW-8 211.30 228.60 I SW-3 -. MW 7 - MW-8 MW-33 22203'... a 21�5>.16 _ MW-8d 211.75 214.11 Q ,A N �Map Data Source: August 2017 Aerial Ph ke@omnty„North Ciero- $0. 300 250 200 50 0 Figure 2 MW-6 - Total Volatile Organic Compounds Concentration Trend North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 �TI, Ln Ln [D [D n n W w M M 0 0 rl rl N N M M�TI, Ln Ln [D w r� n W W M M 0 0 rl rl N N M M-:I, Rt Ln Ln [D [D n n W M M 0 0 rl 6] O] 61 O] O] 1] O] 1] O] 1] O] T O O O O O O O O 0 O O O O O O O 0 O O v - l - i r-I -- -- -- -- -- - -- -- -- ri r-I r-I r-I ri r-I 1- 1- N N N [6 Q [6 Q Q Q Q on. �6 0-�6 0-�6 0-�6 Q �E 0-�6 0-�6 0-�6 Q �6 0-�6 Q Q [0 Q Q� Q [6 Q� Q [6 Q Q [6 Q� Q� Q a�� � � � � and 2E 2E 2E 2E 2E 2E 2 � and � n n Ln � and � n n Ln 2 N N N N N N N N N N N N N N N N N N N N N N N N N N N Date Smith June2021 2❑ 18 16 _ 14 c 6 4 2 0 Figure 3 MW-6d - Total Volatile Organic Compounds Concentration Trend North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 ri r-i N N m m -:I- -:I, LO Ln [D W n r• W W M M 0 0 ri r-i N N m m q:1, Rt Ln Ln [D [D n n W w M M 0 0 rl O O O O O O O O 0 O O O O O O O O O r-I r- r-I r- r-I r- r-I r- r-I .--I r-I r- ry r-I r-I r-I 1- 1- 1- 1- N N N [0 Q Q Q Q [6 Q Q Q Q Q Q Q C. Q Q Q �6 Q Q �6 Q Q 0- Ln N N N N N N N N N N N N N N 2E N N 2E N N N Date Smith June2021 900 800 700 600 r.: N' 500 Q. c 400 L 4+ Li v 300 200 100 0 Figure 4 MW-9 - Total Volatile Organic Compounds Concentration Trend North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 �TI, Ln Ln [D [D n n W w M M 0 0 -- . -i N N M M�TI, Ln Ln [D w r� n W W M M 0 0 r-I r1 N N M M-:I, Rt Ln Ln M M 0 0 r-I 6] O] 61 O] O] 1] O] 1] O] 1] O] T O O O O O O O O 0 O O O O O O O 0 O O O r-I r-I r-I r-I ri r-I r-I r-I ri r-I r-I r-I r-I r-I r-I r-1 ri r-I r-I r-I N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N Date Smith June2021 50 45 40 _ 35 c 30 Q. V1 t Q- 25 15 10 5 0 Figure 5 MW-36 - Total Volatile Organic Compounds Concentration Trend North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 M M M M M 0 0 0 0 r-I r-I r-i r-I N N N N M M M M Rt Rt Ln Ln Ln Ln [D [D [D [D r� n n r� W W w w M M M M 0 0 0 0 r-I O 0 O O O r-I r-I r-I ri r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I ri ri r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I N N N N N V C Q V C Q V C Q V C Q V C Q V C Q V C Q V C Q V C Q V C Q V C Q V C Q V ❑ N❑ N❑ N❑ N❑ N❑ N❑ N❑ N❑ N❑ N❑ N❑ N❑ Date Smith June2021 35 30 25 c L Q. 20 V1 t M CL 10 5 0 Figure 6 MW-36d - Total Volatile Organic Compounds Concentration Trend North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 M M M M M 0 0 0 0 r-I r-I r-i r-I N N N N M M M M Rt Rt Ln Ln Ln Ln [D [D [D [D IN, n n r� W W w w M M M M 0 0 0 0 r-I O 0 O O O r-I r-I r-I ri r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I ri ri r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I r-I N N N N N V C Q V C Q V C Q V C Q V C Q V C Q V C Q V C Q V C Q V C Q V C Q V C Q V ❑ N❑ N❑ N❑ N❑ N❑ N❑ N❑ N❑ N❑ N❑ N❑ N❑ Date Smith June2021 70 --O--Total Volatile Organic Compounds --&-Tetrachloroe the ne {3—Trichforoethene 60 +11-Dichloroethane cis-1,2-Dichloroethene -4-Methylene Chloride 50 0 y 40 Q r C CL rz 0 20 10 o. �Smith Figure 7 MW-5R - Volatile Organic Compounds Concentration Trends North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 m� .nv,w �o N r4 rl e1 w� ni N r�l N ram{ e-1 rl e-1 M e-1 e-f C 4 u C R [J I- C C. [] C ¢ u 4- C R ca v�i o 2 .n 0 2 N O i Date Sodium Lactate Injection i EVO Injection (October2019) ? (December2019) ❑ *t7 C ei rl rl rl rt rl rl rf rl eel rl rl r't N N N N N u C C. to C C. u C C. U C C. u w m y m y d m m y a m June 2021 60 Total Volatile Organic Compounds #Tetrachloroethene —FTrichloroethene --&-1,1-Dichloroethane so cis-1,2-Dichloroeth ene —0-Methylene Chloride 40 c 0 a Q r Q- 30 c D 20 10 Figure 8 MW-34 - Volatile Organic Compounds Concentration Trends North Wake Unlined Landfill - Permit Number 9209-M5WLF-1984 .w we W eK W ri ., r+ ni � wi ni rl W W e{ e1 H fa 2 9 a � � � MW � � .n G3 2 �Smith 5odium Lactate Injection i EVO Injection (October2019) ? (December2019) L W W rl W e-f ei W. W W W W W W �-f rl W W W W N N N N k c a u c a u c IS u c a u 3 N o 3 O vi o m ,n Q g 3 A a m Date June 2021 Figure 9 MW-34d -Volatile Organic Compounds Concentration Trends North Wake Unlined Landfill - Permit Number 9209-MSWLF-1984 45 —0—Total Volatile Organic Compounds Sodium Lactate Injection EVO Injection --&-Tetrachloroe the ne (October2019) '; (December2019) fl-Trichioroethene 40 - -&-1,1-Dichloroethane cis-1,2-Dichloroethene 35 a Methylene Chloride 30 --i c 0 n v 25 n D O V 1� 10 0 T Ln JI In V1 cr, O i� c cL u c p, v C d v •- F u C G v c {1 u G G u c cL u C {} [.+ f. G u lE y y to y y m y y m y y r`o y L m y y m ' y y m y y 10 y y fo 3 y n m .n G3 � � vs �n o � � v� a � � ,n Q g � �n o � Date �Smith June 2021 Appendix A Analytical Data aceAnalytical Report of Analysis CDM Smith 5400 Glenwood Avenue Suite 400 Raleigh, NC 27612 Attention: Mathew Colone Project Name: North Wake Unlined Landfill Lot Number:WD01004 Date Completed:04/15/2021 04/24/2021 4:32 PM Approved and released by: Project Manager II: Cathy S. Dover =w�q a[cArFo f� /716 TN I AM Nauvue Acm^r mn BuaN 11 � eOfFAi� A C C R E D I T E D TESTINGL aORlTOAY The electronic signature above is the equivalent of a handwritten signature. This report shall not be reproduced, except in its entirety, without the written approval of Pace Analytical Services, LLC. Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 Tel:803-791-9700 Fax:803-791-9111 www.pacelabs.com Page 1 of 269 PACE ANALYTICAL SERVICES, LLC SC DHEC No: 32010001 NELAC No: E87653 NC DENR No: 329 NC Field Parameters No: 5639 Case Narrative CDM Smith Lot Number: WD01004 This Report of Analysis contains the analytical result(s) for the sample(s) listed on the Sample Summary following this Case Narrative. The sample receiving date is documented in the header information associated with each sample. All results listed in this report relate only to the samples that are contained within this report. Sample receipt, sample analysis, and data review have been performed in accordance with the most current approved The NELAC Institute (TNI) standards, the Pace Analytical Services, LLC ("Pace") Laboratory Quality Manual, standard operating procedures (SOPS), and Pace policies. Any exceptions to the TNI standards, the Laboratory Quality Manual, SOPS or policies are qualified on the results page or discussed below. VOA 8260D Due to the large number of spiked analytes, there is a high probability that one or more analytes will recover outside acceptance limits. The laboratory's SOP allows for 10% of analytes to recover marginally outside criteria. The following analytes recovered marginally outside LCS/LCSD criteria: trans-1,4- Dichloro-2-butene (69%). The laboratory control sample (LCS) for analytical batch 88149 exceeded acceptance criteria for the following analytes: Acetone(146%). Acetone was biased high and was not detected in the associated samples: WD01004-011 (MW-6d), WD01004-012 (MW-6), WD01004-013 (MW-35), WD01004-014 (MW- 34), WD01004-015 (MW-34d), WD01004-017 (MW-33), WD01004-018 (MW-31d) , WD01004-019 (MW- 31), WD01004-020 (MW-32), WD01004-021 (TB1ad), WD01004-022 (TB1a), WD01004-023 (MW-30), WD01004-024 (MW-29d), WD01004-025 (MW-28), WD01004-026 (MW-28d), WD01004-027 (MW-11d), WD01004-028 (MW-11), and WD01004-029 (MW-8d). Reanalysis of the following samples was performed outside of the analytical holding time for Acetone: WD01004-016 (MW-5R) and WD01004-030 (MW-8). Acetone exceeded acceptance criteria in the CCV and LCS when the sample was initially analyzed. Methane RSK175 The method blank associated with batch 88828 had methane detected at a concentration that was above the DL but below the LOQ. All samples associated with this method blank that have detections for methane have been flagged with a "B" Metals 6020B The method blank associated with batch 88336 had chromium detected at a concentration that was above the DL but below the LOQ. All samples associated with this method blank that have detections for chromium have been flagged with a "B". The MSD for batch 87861 and parent sample WD01004-019 (MW-31), recovered biased high outside of control limits for chromium. The associated LCS and MS passed all acceptance criteria. The RPD for chromium was > 20%. Pace Analytical Services, LLC (formerly Shealy Environmetal Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 2 of 269 PACE ANALYTICAL SERVICES, LLC SC DHEC No: 32010001 NELAC No: E87653 NC DENR No: 329 NC Field Parameters No: 5639 Mercury 7470A The mercury sample prep and analysis was not done for sample WD01004-019 (MW-31) due to volume being used for metals prep batch MS/MSD. The prep analyst used this sample for the batch MS/MSD without realizing that there was only one 250ml container received for the sample. Chloride 300.0 Sample WD01004-016 (MW-5R) was diluted due to the nature of the sample matrix. The LOQ has been elevated to reflect the dilution. Sulfate 300.0 Sample WD01004-016 (MW-5R) was diluted due to the nature of the sample matrix. The LOQ has been elevated to reflect the dilution. Nitrate 300.0 Sample WD01004-016 (MW-5R) was diluted due to the nature of the sample matrix. The LOQ has been elevated to reflect the dilution. The following samples were diluted due to the nature of the sample matrix: WD01004-008 (MW-9) and WD01004-030 (MW-8). The LOQ has been elevated to reflect the dilution. Reanalysis of the following sample(s) was performed outside of the analytical holding time: WD01004-008 (MW-9) and WD01004-030 (MW-8). These samples were reanalyzed OOH due to matrix interference during initial analysis. Both runs have been reported. The method blank for analytical batch 88382 contained nitrate greater than the acceptance criteria. The associated samples, WD01004-008 (MW-9) and WD01004-030 (MW-8), did not contain detections for nitrate; therefore, re -analysis of samples was not performed. The data has been reported. BOD The method blank result was higher than the method -required limit of 0.20mg/L. The following associated samples have been reported with a "4" qualifier: WD01004-006 (MW-10), WD01004-008 (MW-9), WD01004-010 (MW-36), WD01004-012 (MW-6), WD01004-014 (MW-34), WD01004-015 (MW-34d), WD01004-016 (MW-5R), WD01004-028 (MW-11) and WD01004-030 (MW-8). COD The MS/MSD for batch 87813 and parent sample WD01004-030 (MW-8), recovered biased high outside control limits. The associated LCS passed all acceptance criteria. If you have any questions regarding this report please contact the Pace Project Manager listed on the cover page. Pace Analytical Services, LLC (formerly Shealy Environmetal Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 3 of 269 PACE ANALYTICAL SERVICES, LLC Sample Summary CDM Smith Lot Number: WD01004 Project Name: North Wake Unlined Landfill Project Number: Sample Number Sample ID Matrix Date Sampled Date Received 001 MW-7 Aqueous 03/31/20210745 04/01/2021 002 MW-24 Aqueous 03/31/20210755 04/01/2021 003 MW-23 Aqueous 03/31/20210800 04/01/2021 004 MW-23d Aqueous 03/31/20210805 04/01/2021 005 MW-10d Aqueous 03/31/20210815 04/01/2021 006 MW-10 Aqueous 03/31/20210820 04/01/2021 007 MW-22 Aqueous 03/31/20210835 04/01/2021 008 MW-9 Aqueous 03/31/20210845 04/01/2021 009 MW-36d Aqueous 03/31/20210900 04/01/2021 010 MW-36 Aqueous 03/31/20210905 04/01/2021 011 MW-6d Aqueous 03/31/20210920 04/01/2021 012 MW-6 Aqueous 03/31/20210930 04/01/2021 013 MW-35 Aqueous 03/31/20210945 04/01/2021 014 MW-34 Aqueous 03/31/20211000 04/01/2021 015 MW-34d Aqueous 03/31/20211010 04/01/2021 016 MW-5R Aqueous 03/31/20211025 04/01/2021 017 MW-33 Aqueous 03/31/20211040 04/01/2021 018 MW-31d Aqueous 03/31/20211110 04/01/2021 019 MW-31 Aqueous 03/31/20211115 04/01/2021 020 MW-32 Aqueous 03/31/20211120 04/01/2021 021 TB1ad Aqueous 03/31/20211125 04/01/2021 022 TB1a Aqueous 03/31/20211130 04/01/2021 023 MW-30 Aqueous 03/31/20211140 04/01/2021 024 MW-29d Aqueous 03/31/20211150 04/01/2021 025 MW-28 Aqueous 03/31/20211205 04/01/2021 026 MW-28d Aqueous 03/31/20211210 04/01/2021 027 MW-11d Aqueous 03/31/20211220 04/01/2021 028 MW-11 Aqueous 03/31/20211230 04/01/2021 029 MW-8d Aqueous 03/31/20211330 04/01/2021 030 MW-8 Aqueous 03/31/20211345 04/01/2021 031 SW-7 Aqueous 03/31/20211400 04/01/2021 032 SW-8 Aqueous 03/31/20211405 04/01/2021 033 SW-3 Aqueous 03/31/20211435 04/01/2021 034 SW-2 Aqueous 03/31/20211520 04/01/2021 035 DUP Aqueous 03/31/20210700 04/01/2021 036 EQ BLANK Aqueous 03/31/2021 1540 04/01/2021 037 TRIP BLANK Aqueous 03/31/2021 04/01/2021 038 MW-5R Aqueous 03/31/20211025 04/01/2021 039 MW-6 Aqueous 03/31/20210930 04/01/2021 040 MW-8 Aqueous 03/31/20211345 04/01/2021 041 MW-9 Aqueous 03/31/20210845 04/01/2021 042 MW-10 Aqueous 03/31/20210820 04/01/2021 043 MW-11 Aqueous 03/31/20211230 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 4 of 269 Sample Summary (Continued) Lot Number: WD01004 Sample Number Sample ID Matrix Date Sampled Date Received 044 MW-34 045 MW-34d Aqueous 03/31/20211000 04/01/2021 Aqueous 03/31/20211010 04/01/2021 046 MW-36 Aqueous 03/31/20210905 04/01/2021 (46 samples) Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 5 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-001 Description: MW-7 Matrix: Aqueous Date Sampled:03/31/2021 0745 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20211717 ECB 88002 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 1.1 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 1.2 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.53 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 2.2 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 6 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-001 Description: MW-7 Matrix: Aqueous Date Sampled:03/31/2021 0745 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20211717 ECB 88002 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 111 70-130 98 70-130 106 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 7 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-001 Description: MW-7 Matrix: Aqueous Date Sampled:03/31/2021 0745 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1537 CMS2 04/07/2021 1224 88214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 8 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-001 Description: MW-7 Matrix: Aqueous Date Sampled:03/31/2021 0745 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1730 BNW Prep Date Batch 04/04/2021 0532 87860 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 46 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.37 J 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 3.2 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 47 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 10 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 2.5 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 13 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 8.1 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 17 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 9 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-002 Description: MW-24 Matrix: Aqueous Date Sampled:03/31/2021 0755 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20211742 ECB 88002 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.64 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 10 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-002 Description: MW-24 Matrix: Aqueous Date Sampled:03/31/2021 0755 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20211742 ECB 88002 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 111 70-130 100 70-130 106 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 11 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-002 Description: MW-24 Matrix: Aqueous Date Sampled:03/31/2021 0755 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1539 CMS2 04/07/2021 1224 88214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 12 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-002 Description: MW-24 Matrix: Aqueous Date Sampled:03/31/2021 0755 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1736 BNW Prep Date Batch 04/04/2021 0532 87860 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 15 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.20 J 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 1.7 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.0 U 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.80 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 3.2 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 7.6 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 13 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-003 Description: MW-23 Matrix: Aqueous Date Sampled:03/31/2021 0800 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20211806 ECB 88002 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 14 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-003 Description: MW-23 Matrix: Aqueous Date Sampled:03/31/2021 0800 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20211806 ECB 88002 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 108 70-130 97 70-130 108 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 15 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-003 Description: MW-23 Matrix: Aqueous Date Sampled:03/31/2021 0800 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1542 CMS2 04/07/2021 1224 88214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 16 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-003 Description: MW-23 Matrix: Aqueous Date Sampled:03/31/2021 0800 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1753 BNW Prep Date Batch 04/04/2021 0532 87860 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 25 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 4.2 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 6.2 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 3.0 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 2.7 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 9.1 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 12 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 17 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-004 Description: MW-23d Matrix: Aqueous Date Sampled:03/31/2021 0805 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20211831 ECB 88002 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 18 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-004 Description: MW-23d Matrix: Aqueous Date Sampled:03/31/2021 0805 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20211831 ECB 88002 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 108 70-130 97 70-130 109 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 19 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-004 Description: MW-23d Matrix: Aqueous Date Sampled:03/31/2021 0805 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1545 CMS2 04/07/2021 1224 88214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 20 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-004 Description: MW-23d Matrix: Aqueous Date Sampled:03/31/2021 0805 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1759 BNW Prep Date Batch 04/04/2021 0532 87860 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 0.61 J 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 37 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.21 J 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 9.8 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 2.9 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.26 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 1.3 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 3.7 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 14 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 21 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-005 Description: MW-10d Matrix: Aqueous Date Sampled:03/31/2021 0815 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20211856 ECB 88002 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.71 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 22 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-005 Description: MW-10d Matrix: Aqueous Date Sampled:03/31/2021 0815 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20211856 ECB 88002 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 107 70-130 96 70-130 108 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 23 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-005 Description: MW-10d Matrix: Aqueous Date Sampled:03/31/2021 0815 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1547 CMS2 04/07/2021 1224 88214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 24 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-005 Description: MW-10d Matrix: Aqueous Date Sampled:03/31/2021 0815 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1805 BNW Prep Date Batch 04/04/2021 0532 87860 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 1.4 J 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 4.5 J 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.27 J 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 3.6 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 2.0 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.29 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 3.4 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 10 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 25 of 269 Inorganic non-metals Client:CDM Smith Laboratory ID:WD01004-006 Description: MW-10 Matrix: Aqueous Date Sampled:03/31/2021 0820 Project Name: North Wake Unlined Landfill Date Received: 04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/08/2021 2035 DAK 88496 1 (BOD, 5 day) SM 521OB-2011 1 04/06/2021 2048 JAG 04/01/2021 2151 87671 1 (Chloride) 300.0 1 04/01/2021 1623 AMR 87768 1 (CO2 (calcula) SM 4500-CO2 D 1 04/08/2021 2035 DAK 1 (COD) SM 5220D-2011 1 04/02/2021 1624 AMR 87813 1 (Nitrate - N) 300.0 1 04/01/2021 1623 AMR 87773 1 (Sulfate) 300.0 1 04/01/2021 1623 AMR 87772 1 (Sulfide) SM 4500-S2 F-2011 1 04/06/2021 1907 GDC 88171 1 (TOC) SM 531OC-2011 1 04/02/2021 0350 AAB 87678 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 27 20 20 mg CaCO3/L 1 BOD, 5 day SM 521 OB-2011 2.0 U4 2.0 0.18 mg/L 1 Chloride 300.0 3.1 1.0 0.25 mg/L 1 CO2 (calculation) 124-38-9 SM 4500-CO2 D 220 27 27 mg/L 1 COD SM 5220D-2011 20 U 20 20 mg/L 1 Nitrate - N 300.0 2.0 0.020 0.0050 mg/L 1 Sulfate 300.0 0.32 J 1.0 0.25 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 1.0 U 1.0 0.99 mg/L 1 TOC SM 531OC-2011 2.1 1.0 1.0 mg/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 26 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-006 Description: MW-10 Matrix: Aqueous Date Sampled:03/31/2021 0820 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20211921 ECB 88002 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 27 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-006 Description: MW-10 Matrix: Aqueous Date Sampled:03/31/2021 0820 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20211921 ECB 88002 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 109 70-130 101 70-130 105 70-130 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 28 of 269 Dissolved Gases Client:CDM Smith Laboratory ID:WD01004-006 Description: MW-10 Matrix: Aqueous Date Sampled:03/31/2021 0820 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 04/12/2021 0932 TML 88775 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 10 U 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 10 U 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 18 10 2.5 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 29 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-006 Description: MW-10 Matrix: Aqueous Date Sampled:03/31/2021 0820 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1550 CMS2 04/07/2021 1224 88214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.000097 J 0.00020 0.000091 mg/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 30 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-006 Description: MW-10 Matrix: Aqueous Date Sampled:03/31/2021 0820 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1811 BNW Prep Date Batch 04/04/2021 0532 87860 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 16 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.16 J 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 1.1 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 56 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.8 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.47 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 4.0 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 4.5 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 31 10 2.5 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 31 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-007 Description: MW-22 Matrix: Aqueous Date Sampled:03/31/2021 0835 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20211945 ECB 88002 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 32 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-007 Description: MW-22 Matrix: Aqueous Date Sampled:03/31/2021 0835 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20211945 ECB 88002 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 107 70-130 98 70-130 107 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 33 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-007 Description: MW-22 Matrix: Aqueous Date Sampled:03/31/2021 0835 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1604 CMS2 04/07/2021 1224 88214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 34 of 269 Inorganic non-metals Client:CDM Smith Laboratory ID:WD01004-008 Description: MW-9 Matrix: Aqueous Date Sampled:03/31/2021 0845 Project Name: North Wake Unlined Landfill Date Received: 04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/08/2021 2043 DAK 88496 1 (BOD, 5 day) SM 521OB-2011 1 04/06/2021 2050 JAG 04/01/2021 2154 87671 1 (Chloride) 300.0 1 04/01/2021 1720 AMR 87768 1 (CO2 (calcula) SM 4500-CO2 D 1 04/08/2021 2043 DAK 1 (COD) SM 5220D-2011 1 04/02/2021 1625 AMR 87813 1 (Nitrate - N) 300.0 1 04/01/2021 1720 AMR 87773 2 (Nitrate - N) 300.0 5 04/07/2021 1616 AMR 88382 1 (Sulfate) 300.0 1 04/01/2021 1720 AMR 87772 1 (Sulfide) SM 4500-S2 F-2011 1 04/06/2021 1907 GDC 88171 1 (TOC) SM 531OC-2011 1 04/02/2021 0403 AAB 87678 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su BOD, 5 day Chloride CO2 (calculation) COD Sulfate Nitrate - N Sulfide Nitrate - N TOC Footnote(s): 4-Blank depletion > 0.20 mg/L SM 2320B-2011 490 20 20 mg CaCO3/L 1 SM 521OB-2011 4.3 4 2.0 0.18 mg/L 1 300.0 45 1.0 0.25 mg/L 1 124-38-9 SM 4500-CO2 D 820 27 27 mg/L 1 SM 5220D-2011 36 20 20 mg/L 1 300.0 0.61 J 1.0 0.25 mg/L 1 300.0 0.020 U 0.020 0.0050 mg/L 1 18496-25-8 SM 4500-S2 F-2 1.0 U 1.0 0.99 mg/L 1 300.0 0.10 UH 0.10 0.025 mg/L 2 SM 531OC-2011 9.4 1.0 1.0 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 36 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-008 Description: MW-9 Matrix: Aqueous Date Sampled:03/31/2021 0845 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20212010 ECB 88002 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.55 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 10 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 4.6 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 4.1 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.40 J 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 37 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-008 Description: MW-9 Matrix: Aqueous Date Sampled:03/31/2021 0845 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20212010 ECB 88002 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 26 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 109 70-130 97 70-130 106 70-130 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 38 of 269 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:WD01004-008 Description: MW-9 Matrix: Aqueous Date Sampled:03/31/2021 0845 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 2 5030B 8260D (SIM) 1 04/08/2021 2305 CJL2 88465 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 6.0 3.0 1.0 ug/L 2 Run 2 Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 111 40-170 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 39 of 269 Dissolved Gases Client:CDM Smith Laboratory ID:WD01004-008 Description: MW-9 Matrix: Aqueous Date Sampled:03/31/2021 0845 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 04/12/2021 0948 TML 88775 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 10 U 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 10 U 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 1800 10 2.5 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 40 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-008 Description: MW-9 Matrix: Aqueous Date Sampled:03/31/2021 0845 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1606 CMS2 04/07/2021 1224 88214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 41 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-008 Description: MW-9 Matrix: Aqueous Date Sampled:03/31/2021 0845 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1823 BNW Prep Date Batch 04/04/2021 0532 87860 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 390 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.15 J 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 2.7 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 2.4 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 1.4 J 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 11 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.4 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 8.9 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.16 J 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 9.3 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 25 10 2.5 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 42 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-009 Description: MW-36d Matrix: Aqueous Date Sampled:03/31/2021 0900 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20212035 ECB 88002 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 0.53 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 43 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-009 Description: MW-36d Matrix: Aqueous Date Sampled:03/31/2021 0900 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20212035 ECB 88002 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 112 70-130 102 70-130 108 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 44 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-009 Description: MW-36d Matrix: Aqueous Date Sampled:03/31/2021 0900 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1609 CMS2 04/07/2021 1224 88214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 45 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-009 Description: MW-36d Matrix: Aqueous Date Sampled:03/31/2021 0900 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1829 BNW Prep Date Batch 04/04/2021 0532 87860 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 16 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 86 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.1 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 3.5 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 2.6 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 130 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 46 of 269 Inorganic non-metals Client:CDM Smith Laboratory ID:WD01004-010 Description: MW-36 Matrix: Aqueous Date Sampled:03/31/2021 0905 Project Name: North Wake Unlined Landfill Date Received: 04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/08/2021 2058 DAK 88496 1 (BOD, 5 day) SM 521OB-2011 1 04/06/2021 2053 JAG 04/01/2021 2200 87671 1 (Chloride) 300.0 1 04/01/2021 1738 AMR 87768 1 (CO2 (calcula) SM 4500-CO2 D 1 04/08/2021 2058 DAK 1 (COD) SM 5220D-2011 1 04/02/2021 1625 AMR 87813 1 (Nitrate - N) 300.0 1 04/01/2021 1738 AMR 87773 1 (Sulfate) 300.0 1 04/01/2021 1738 AMR 87772 1 (Sulfide) SM 4500-S2 F-2011 1 04/06/2021 1907 GDC 88171 1 (TOC) SM 531OC-2011 1 04/02/2021 0417 AAB 87678 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 56 20 20 mg CaCO3/L 1 BOD, 5 day SM 521 OB-2011 2.0 U4 2.0 0.18 mg/L 1 Chloride 300.0 9.3 1.0 0.25 mg/L 1 CO2 (calculation) 124-38-9 SM 4500-CO2 D 140 27 27 mg/L 1 COD SM 5220D-2011 20 U 20 20 mg/L 1 Nitrate - N 300.0 0.16 0.020 0.0050 mg/L 1 Sulfate 300.0 2.9 1.0 0.25 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 1.3 1.0 0.99 mg/L 1 TOC SM 531OC-2011 1.0 U 1.0 1.0 mg/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 47 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-010 Description: MW-36 Matrix: Aqueous Date Sampled:03/31/2021 0905 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20212100 ECB 88002 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 1.1 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 2.2 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 48 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-010 Description: MW-36 Matrix: Aqueous Date Sampled:03/31/2021 0905 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20212100 ECB 88002 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 110 70-130 99 70-130 109 70-130 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 49 of 269 Dissolved Gases Client:CDM Smith Laboratory ID:WD01004-010 Description: MW-36 Matrix: Aqueous Date Sampled:03/31/2021 0905 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 04/12/2021 1004 TML 88775 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 10 U 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 10 U 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 47 10 2.5 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 50 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-010 Description: MW-36 Matrix: Aqueous Date Sampled:03/31/2021 0905 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1612 CMS2 04/07/2021 1224 88214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 51 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-010 Description: MW-36 Matrix: Aqueous Date Sampled:03/31/2021 0905 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1835 BNW Prep Date Batch 04/04/2021 0532 87860 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 65 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 21 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 2.8 J 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 12 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.97 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 4.9 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 14 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 12 10 2.5 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 52 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-011 Description: MW-6d Matrix: Aqueous Date Sampled:03/31/2021 0920 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211429 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.46 J 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 UL 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 1.1 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 53 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-011 Description: MW-6d Matrix: Aqueous Date Sampled:03/31/2021 0920 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211429 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 96 70-130 94 70-130 101 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 54 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-011 Description: MW-6d Matrix: Aqueous Date Sampled:03/31/2021 0920 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1614 CMS2 04/07/2021 1224 88214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 55 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-011 Description: MW-6d Matrix: Aqueous Date Sampled:03/31/2021 0920 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1841 BNW Prep Date Batch 04/04/2021 0532 87860 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 0.78 J 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 85 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.17 J 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 4.2 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 2.1 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.25 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 1.6 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 3.0 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 8.5 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 56 of 269 Inorganic non-metals Client:CDM Smith Laboratory ID:WD01004-012 Description: MW-6 Matrix: Aqueous Date Sampled:03/31/2021 0930 Project Name: North Wake Unlined Landfill Date Received: 04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/08/2021 2104 DAK 88496 1 (BOD, 5 day) SM 521OB-2011 1 04/06/2021 2054 JAG 04/01/2021 2206 87671 1 (Chloride) 300.0 1 04/01/2021 1757 AMR 87768 1 (CO2 (calcula) SM 4500-CO2 D 1 04/08/2021 2104 DAK 1 (COD) SM 5220D-2011 1 04/02/2021 1626 AMR 87813 1 (Nitrate - N) 300.0 1 04/01/2021 1757 AMR 87773 1 (Sulfate) 300.0 1 04/01/2021 1757 AMR 87772 1 (Sulfide) SM 4500-S2 F-2011 1 04/06/2021 1907 GDC 88171 1 (TOC) SM 531OC-2011 1 04/02/2021 0430 AAB 87678 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 140 20 20 mg CaCO3/L 1 BOD, 5 day SM 521 OB-2011 2.0 U4 2.0 0.18 mg/L 1 Chloride 300.0 68 1.0 0.25 mg/L 1 CO2 (calculation) 124-38-9 SM 4500-CO2 D 350 27 27 mg/L 1 COD SM 5220D-2011 20 U 20 20 mg/L 1 Nitrate - N 300.0 0.92 0.020 0.0050 mg/L 1 Sulfate 300.0 3.7 1.0 0.25 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 1.0 U 1.0 0.99 mg/L 1 TOC SM 531OC-2011 2.7 1.0 1.0 mg/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 57 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-012 Description: MW-6 Matrix: Aqueous Date Sampled:03/31/2021 0930 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211452 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 UL 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.68 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 58 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-012 Description: MW-6 Matrix: Aqueous Date Sampled:03/31/2021 0930 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211452 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 107 70-130 94 70-130 108 70-130 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 59 of 269 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:WD01004-012 Description: MW-6 Matrix: Aqueous Date Sampled:03/31/2021 0930 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 04/06/2021 0351 CJL2 88039 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 5.0 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 110 40-170 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 60 of 269 Dissolved Gases Client:CDM Smith Laboratory ID:WD01004-012 Description: MW-6 Matrix: Aqueous Date Sampled:03/31/2021 0930 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 04/12/2021 1020 TML 88775 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 10 U 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 10 U 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 100 10 2.5 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 61 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-012 Description: MW-6 Matrix: Aqueous Date Sampled:03/31/2021 0930 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1617 CMS2 04/07/2021 1224 88214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00019 J 0.00020 0.000091 mg/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 62 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-012 Description: MW-6 Matrix: Aqueous Date Sampled:03/31/2021 0930 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1847 BNW Prep Date Batch 04/04/2021 0532 87860 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 94 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.32 J 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.17 J 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 3.8 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 23 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 2.3 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.88 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 3.8 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 3.8 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 4.4 J 10 2.5 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 63 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-013 Description: MW-35 Matrix: Aqueous Date Sampled:03/31/2021 0945 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211514 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 UL 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.56 0.50 0.40 ug/L 1 1, 1 -Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1, 1 -Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.41 J 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 64 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-013 Description: MW-35 Matrix: Aqueous Date Sampled:03/31/2021 0945 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211514 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 102 70-130 89 70-130 103 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 65 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-013 Description: MW-35 Matrix: Aqueous Date Sampled:03/31/2021 0945 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1620 CMS2 04/07/2021 1224 88214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 66 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-013 Description: MW-35 Matrix: Aqueous Date Sampled:03/31/2021 0945 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1905 BNW Prep Date Batch 04/04/2021 0532 87860 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 36 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 5.0 U 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 4.1 J 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.0 U 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.61 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 3.3 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 11 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 67 of 269 Inorganic non-metals Client:CDM Smith Laboratory ID:WD01004-014 Description: MW-34 Matrix: Aqueous Date Sampled:03/31/2021 1000 Project Name: North Wake Unlined Landfill Date Received: 04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/08/2021 2109 DAK 88496 1 (BOD, 5 day) SM 521OB-2011 1 04/06/2021 2056 JAG 04/01/2021 2209 87671 1 (Chloride) 300.0 1 04/01/2021 1816 AMR 87768 1 (CO2 (calcula) SM 4500-CO2 D 1 04/08/2021 2109 DAK 1 (COD) SM 5220D-2011 1 04/02/2021 1626 AMR 87813 1 (Nitrate - N) 300.0 1 04/01/2021 1816 AMR 87773 1 (Sulfate) 300.0 1 04/01/2021 1816 AMR 87772 1 (Sulfide) SM 4500-S2 F-2011 1 04/06/2021 1907 GDC 88171 1 (TDS) SM 2540C-2011 1 04/01/2021 2357 SJL 87676 1 (TOC) SM 531OC-2011 1 04/02/2021 0535 AAB 87678 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 20 U 20 20 mg CaCO3/L 1 BOD, 5 day SM 521 OB-2011 2.0 U4 2.0 0.18 mg/L 1 Chloride 300.0 54 1.0 0.25 mg/L 1 CO2 (calculation) 124-38-9 SM 4500-CO2 D 190 27 27 mg/L 1 COD SM 5220D-2011 20 U 20 20 mg/L 1 Nitrate - N 300.0 0.020 U 0.020 0.0050 mg/L 1 Sulfate 300.0 5.7 1.0 0.25 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 1.0 U 1.0 0.99 mg/L 1 TDS SM 2540C-2011 140 25 25 mg/L 1 TOC SM 531OC-2011 1.0 U 1.0 1.0 mg/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 68 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-014 Description: MW-34 Matrix: Aqueous Date Sampled:03/31/2021 1000 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211537 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.43 J 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 UL 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 7.0 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 3.3 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 1.4 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.87 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 1.3 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 69 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-014 Description: MW-34 Matrix: Aqueous Date Sampled:03/31/2021 1000 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211537 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 110 70-130 94 70-130 109 70-130 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 70 of 269 Dissolved Gases Client:CDM Smith Laboratory ID:WD01004-014 Description: MW-34 Matrix: Aqueous Date Sampled:03/31/2021 1000 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 04/12/2021 1036 TML 88775 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 10 U 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 10 U 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 26 10 2.5 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 71 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-014 Description: MW-34 Matrix: Aqueous Date Sampled:03/31/2021 1000 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1622 CMS2 04/07/2021 1224 88214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 72 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-014 Description: MW-34 Matrix: Aqueous Date Sampled:03/31/2021 1000 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1910 BNW Prep Date Batch 04/04/2021 0532 87860 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 240 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.91 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.30 J 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 28 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 7.9 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 13 5.0 1.3 ug/L 1 Iron 7439-89-6 6020B 6100 50 13 ug/L 1 Lead 7439-92-1 6020B 2.4 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 11 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Sodium 7440-23-5 6020B 24000 400 150 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 16 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 36 10 2.5 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 73 of 269 Inorganic non-metals Client:CDM Smith Laboratory ID:WD01004-015 Description: MW-34d Matrix: Aqueous Date Sampled:03/31/2021 1010 Project Name: North Wake Unlined Landfill Date Received: 04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/08/2021 2141 DAK 88497 1 (BOD, 5 day) SM 521OB-2011 1 04/06/2021 2058 JAG 04/01/2021 2214 87671 1 (Chloride) 300.0 1 04/01/2021 1835 AMR 87768 1 (CO2 (calcula) SM 4500-CO2 D 1 04/08/2021 2141 DAK 1 (COD) SM 5220D-2011 1 04/02/2021 1627 AMR 87813 1 (Nitrate - N) 300.0 1 04/01/2021 1835 AMR 87773 1 (Sulfate) 300.0 1 04/01/2021 1835 AMR 87772 1 (Sulfide) SM 4500-S2 F-2011 1 04/06/2021 1907 GDC 88171 1 (TDS) SM 2540C-2011 1 04/01/2021 2357 SJL 87676 1 (TOC) SM 531OC-2011 1 04/02/2021 0548 AAB 87678 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 59 20 20 mg CaCO3/L 1 BOD, 5 day SM 521 OB-2011 2.0 U4 2.0 0.18 mg/L 1 Chloride 300.0 9.9 1.0 0.25 mg/L 1 CO2 (calculation) 124-38-9 SM 4500-CO2 D 110 27 27 mg/L 1 COD SM 5220D-2011 20 U 20 20 mg/L 1 Nitrate - N 300.0 0.50 0.020 0.0050 mg/L 1 Sulfate 300.0 1.2 1.0 0.25 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 1.0 U 1.0 0.99 mg/L 1 TDS SM 2540C-2011 110 25 25 mg/L 1 TOC SM 531OC-2011 1.0 U 1.0 1.0 mg/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 74 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-015 Description: MW-34d Matrix: Aqueous Date Sampled:03/31/2021 1010 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211559 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 4.1 JL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 UL 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.45 J 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 2.3 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 2.2 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 1.0 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.41 J 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 75 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-015 Description: MW-34d Matrix: Aqueous Date Sampled:03/31/2021 1010 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211559 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 108 70-130 95 70-130 105 70-130 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 76 of 269 Dissolved Gases Client:CDM Smith Laboratory ID:WD01004-015 Description: MW-34d Matrix: Aqueous Date Sampled:03/31/2021 1010 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 04/12/2021 1051 TML 88775 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 10 U 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 10 U 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 6.7 J 10 2.5 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 77 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-015 Description: MW-34d Matrix: Aqueous Date Sampled:03/31/2021 1010 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1625 CMS2 04/07/2021 1224 88214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00013 J 0.00020 0.000091 mg/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 78 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-015 Description: MW-34d Matrix: Aqueous Date Sampled:03/31/2021 1010 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1916 BNW Prep Date Batch 04/04/2021 0532 87860 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 26 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 2.2 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 9.8 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 2.9 J 5.0 1.3 ug/L 1 Iron 7439-89-6 6020B 160 50 13 ug/L 1 Lead 7439-92-1 6020B 0.27 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Sodium 7440-23-5 6020B 8600 400 150 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 12 10 2.5 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 79 of 269 Inorganic non-metals Client:CDM Smith Laboratory ID:WD01004-016 Description: MW-5R Matrix: Aqueous Date Sampled:03/31/2021 1025 Project Name: North Wake Unlined Landfill Date Received: 04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/08/2021 2149 DAK 88497 1 (BOD, 5 day) SM 521OB-2011 1 04/06/2021 2059 JAG 04/01/2021 2214 87671 1 (Chloride) 300.0 5 04/01/2021 1854 AMR 87768 1 (CO2 (calcula) SM 4500-CO2 D 1 04/08/2021 2149 DAK 2 (COD) SM 5220D-2011 1 04/09/2021 1500 AMR 88533 1 (Nitrate - N) 300.0 5 04/01/2021 1854 AMR 87773 1 (Sulfate) 300.0 5 04/01/2021 1854 AMR 87772 1 (Sulfide) SM 4500-S2 F-2011 1 04/06/2021 1907 GDC 88171 1 (TDS) SM 2540C-2011 1 04/01/2021 2357 SJL 87676 2 (TOC) SM 531OC-2011 1 04/06/2021 1830 AAB 88140 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 270 20 20 mg CaCO3/L 1 BOD, 5 day SM 521 OB-2011 100 4 2.0 0.18 mg/L 1 Chloride 300.0 3.4 JD 5.0 1.3 mg/L 1 CO2 (calculation) 124-38-9 SM 4500-CO2 D 750 27 27 mg/L 1 COD SM 5220D-2011 280 20 20 mg/L 2 Nitrate - N 300.0 0.027 JD 0.10 0.025 mg/L 1 Sulfate 300.0 5.0 U 5.0 1.3 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 1.0 U 1.0 0.99 mg/L 1 TDS SM 2540C-2011 290 25 25 mg/L 1 TOC SM 531OC-2011 58 1.0 1.0 mg/L 2 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 80 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-016 Description: MW-5R Matrix: Aqueous Date Sampled:03/31/2021 1025 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211622 BWS 88149 2 5030B 8260D 1 04/10/20210000 DJG 88591 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 29 H 10 4.0 ug/L 2 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 3.7 J 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 UL 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1, 1 -Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1, 1 -Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 1.4 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 6.1 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 81 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-016 Description: MW-5R Matrix: Aqueous Date Sampled:03/31/2021 1025 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211622 BWS 88149 2 5030B 8260D 1 04/10/20210000 DJG 88591 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Run 2 Acceptance Surrogate Q % Recovery Limits Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 105 70-130 H 103 70-130 86 70-130 H 101 70-130 106 70-130 H 107 70-130 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 82 of 269 Dissolved Gases Client:CDM Smith Laboratory ID:WD01004-016 Description: MW-5R Matrix: Aqueous Date Sampled:03/31/2021 1025 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 04/12/2021 1107 TML 88775 2 RSK - 175 10 04/13/2021 0936 TML 88828 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 10 U 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 10 U 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 7000 BD 100 25 ug/L 2 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 83 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-016 Description: MW-5R Matrix: Aqueous Date Sampled:03/31/2021 1025 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1633 CMS2 04/07/2021 1224 88214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 84 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-016 Description: MW-5R Matrix: Aqueous Date Sampled:03/31/2021 1025 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1922 BNW Prep Date Batch 04/04/2021 0532 87860 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 64 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.15 J 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 4.9 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 75 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 1.5 J 5.0 1.3 ug/L 1 Iron 7439-89-6 6020B 84000 50 13 ug/L 1 Lead 7439-92-1 6020B 0.52 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 12 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Sodium 7440-23-5 6020B 5000 400 150 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 2.7 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 11 10 2.5 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 85 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-017 Description: MW-33 Matrix: Aqueous Date Sampled:03/31/2021 1040 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211645 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 UL 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 86 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-017 Description: MW-33 Matrix: Aqueous Date Sampled:03/31/2021 1040 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211645 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 107 70-130 91 70-130 108 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 87 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-017 Description: MW-33 Matrix: Aqueous Date Sampled:03/31/2021 1040 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1636 CMS2 04/07/2021 1224 88214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 88 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-017 Description: MW-33 Matrix: Aqueous Date Sampled:03/31/2021 1040 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1928 BNW Prep Date Batch 04/04/2021 0532 87860 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 56 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 7.3 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.0 U 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 1.7 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 3.7 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 5.2 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 89 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-018 Description: MW-31d Matrix: Aqueous Date Sampled:03/31/2021 1110 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211707 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 4.1 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 UL 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 90 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-018 Description: MW-31d Matrix: Aqueous Date Sampled:03/31/2021 1110 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211707 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 103 70-130 92 70-130 101 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 91 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-018 Description: MW-31d Matrix: Aqueous Date Sampled:03/31/2021 1110 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1638 CMS2 04/07/2021 1224 88214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 92 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-018 Description: MW-31d Matrix: Aqueous Date Sampled:03/31/2021 1110 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1934 BNW Prep Date Batch 04/04/2021 0532 87860 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 0.99 J 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 20 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.20 J 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 4.9 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 1.9 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 6.6 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 87 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 93 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-019 Description: MW-31 Matrix: Aqueous Date Sampled:03/31/2021 1115 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211729 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.40 J 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 UL 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 94 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-019 Description: MW-31 Matrix: Aqueous Date Sampled:03/31/2021 1115 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211729 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 105 70-130 98 70-130 108 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 95 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-019 Description: MW-31 Matrix: Aqueous Date Sampled:03/31/2021 1115 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1327 BNW Prep Date Batch 04/04/2021 0532 87861 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 25 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 11 S 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.3 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 2.1 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 1.6 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 12 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 6.3 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 96 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-020 Description: MW-32 Matrix: Aqueous Date Sampled:03/31/2021 1120 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211752 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.97 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 UL 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 97 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-020 Description: MW-32 Matrix: Aqueous Date Sampled:03/31/2021 1120 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211752 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 107 70-130 93 70-130 107 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 98 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-020 Description: MW-32 Matrix: Aqueous Date Sampled:03/31/2021 1120 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1641 CMS2 04/07/2021 1224 88214 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 99 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-020 Description: MW-32 Matrix: Aqueous Date Sampled:03/31/2021 1120 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1357 BNW Prep Date Batch 04/04/2021 0532 87861 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 0.62 J 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 11 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.27 J 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 1.8 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 3.5 J 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 4.2 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 1.8 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 3.6 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 11 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 100 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-021 Description: TB1ad Matrix: Aqueous Date Sampled:03/31/2021 1125 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20212227 CJL2 88043 2 5030B 8260D 1 04/06/20211345 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 UL 2.0 0.40 ug/L 2 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1, 1 -Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1, 1 -Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 101 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-021 Description: TB1ad Matrix: Aqueous Date Sampled:03/31/2021 1125 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20212227 CJL2 88043 2 5030B 8260D 1 04/06/20211345 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Run 2 Acceptance Surrogate Q % Recovery Limits Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 109 70-130 109 70-130 95 70-130 92 70-130 107 70-130 109 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 102 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-021 Description: TB1ad Matrix: Aqueous Date Sampled:03/31/2021 1125 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1649 CMS2 04/07/2021 1224 88215 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 103 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-021 Description: TB1ad Matrix: Aqueous Date Sampled:03/31/2021 1125 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1403 BNW Prep Date Batch 04/04/2021 0532 87861 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 0.53 J 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 17 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.28 J 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 4.8 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 2.3 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 3.4 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 25 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 104 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-022 Description: TB1a Matrix: Aqueous Date Sampled:03/31/2021 1130 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20212250 CJL2 88043 2 5030B 8260D 1 04/06/20211407 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 UL 2.0 0.40 ug/L 2 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1, 1 -Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1, 1 -Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 105 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-022 Description: TB1a Matrix: Aqueous Date Sampled:03/31/2021 1130 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/05/20212250 CJL2 88043 2 5030B 8260D 1 04/06/20211407 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Run 2 Acceptance Surrogate Q % Recovery Limits Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 104 70-130 106 70-130 95 70-130 91 70-130 106 70-130 107 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 106 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-022 Description: TB1a Matrix: Aqueous Date Sampled:03/31/2021 1130 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1652 CMS2 04/07/2021 1224 88215 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00010 J 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 107 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-022 Description: TB1a Matrix: Aqueous Date Sampled:03/31/2021 1130 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1408 BNW Prep Date Batch 04/04/2021 0532 87861 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 19 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 6.6 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 6.5 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 3.2 J 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 4.7 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.48 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 4.7 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 3.1 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 21 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 108 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-023 Description: MW-30 Matrix: Aqueous Date Sampled:03/31/2021 1140 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211815 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 UL 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 109 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-023 Description: MW-30 Matrix: Aqueous Date Sampled:03/31/2021 1140 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211815 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 101 70-130 91 70-130 107 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 110 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-023 Description: MW-30 Matrix: Aqueous Date Sampled:03/31/2021 1140 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1654 CMS2 04/07/2021 1224 88215 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 111 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-023 Description: MW-30 Matrix: Aqueous Date Sampled:03/31/2021 1140 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1543 BNW Prep Date Batch 04/04/2021 0532 87861 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 78 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.26 J 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.16 J 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 13 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 2.5 J 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 9.4 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 2.5 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 4.2 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 11 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 24 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 112 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-024 Description: MW-29d Matrix: Aqueous Date Sampled:03/31/2021 1150 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211837 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 UL 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 113 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-024 Description: MW-29d Matrix: Aqueous Date Sampled:03/31/2021 1150 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211837 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 102 70-130 95 70-130 105 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 114 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-024 Description: MW-29d Matrix: Aqueous Date Sampled:03/31/2021 1150 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1657 CMS2 04/07/2021 1224 88215 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 115 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-024 Description: MW-29d Matrix: Aqueous Date Sampled:03/31/2021 1150 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1549 BNW Prep Date Batch 04/04/2021 0532 87861 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 0.64 J 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 45 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 5.6 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 6.9 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.73 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 2.0 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 3.3 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 88 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 116 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-025 Description: MW-28 Matrix: Aqueous Date Sampled:03/31/2021 1205 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211900 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 UL 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 117 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-025 Description: MW-28 Matrix: Aqueous Date Sampled:03/31/2021 1205 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211900 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 100 70-130 94 70-130 102 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 118 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-025 Description: MW-28 Matrix: Aqueous Date Sampled:03/31/2021 1205 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1705 CMS2 04/07/2021 1224 88215 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 119 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-025 Description: MW-28 Matrix: Aqueous Date Sampled:03/31/2021 1205 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1555 BNW Prep Date Batch 04/04/2021 0532 87861 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 32 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.16 J 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 5.7 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 2.6 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.1 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 1.9 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 8.4 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 29 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 120 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-026 Description: MW-28d Matrix: Aqueous Date Sampled:03/31/2021 1210 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211922 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 UL 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 121 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-026 Description: MW-28d Matrix: Aqueous Date Sampled:03/31/2021 1210 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211922 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 109 70-130 98 70-130 110 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 122 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-026 Description: MW-28d Matrix: Aqueous Date Sampled:03/31/2021 1210 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1708 CMS2 04/07/2021 1224 88215 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 123 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-026 Description: MW-28d Matrix: Aqueous Date Sampled:03/31/2021 1210 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1601 BNW Prep Date Batch 04/04/2021 0532 87861 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 15 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 2.9 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 3.8 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.2 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 6.3 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 6.7 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 15 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 124 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-027 Description: MW-11d Matrix: Aqueous Date Sampled:03/31/2021 1220 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211944 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 4.4 JL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 UL 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 125 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-027 Description: MW-11d Matrix: Aqueous Date Sampled:03/31/2021 1220 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20211944 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 104 70-130 98 70-130 109 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 126 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-027 Description: MW-11d Matrix: Aqueous Date Sampled:03/31/2021 1220 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1711 CMS2 04/07/2021 1224 88215 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 127 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-027 Description: MW-11d Matrix: Aqueous Date Sampled:03/31/2021 1220 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 2 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/12/2021 1938 BPK Prep Date Batch 04/09/2021 0402 88336 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 0.66 J 2.0 0.50 ug/L 2 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 2 Barium 7440-39-3 6020B 46 5.0 1.3 ug/L 2 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 2 Cadmium 7440-43-9 6020B 0.40 J 0.50 0.13 ug/L 2 Chromium 7440-47-3 6020B 3.2 BJ 5.0 1.3 ug/L 2 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 2 Copper 7440-50-8 6020B 4.6 J 5.0 1.3 ug/L 2 Lead 7439-92-1 6020B 0.25 J 1.0 0.25 ug/L 2 Nickel 7440-02-0 6020B 1.4 J 5.0 1.3 ug/L 2 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 2 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 2 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 2 Vanadium 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 2 Zinc 7440-66-6 6020B 10 10 2.5 ug/L 2 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 128 of 269 Inorganic non-metals Client:CDM Smith Laboratory ID:WD01004-028 Description: MW-11 Matrix: Aqueous Date Sampled:03/31/2021 1230 Project Name: North Wake Unlined Landfill Date Received: 04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/08/2021 2153 DAK 88497 1 (BOD, 5 day) SM 521OB-2011 1 04/06/2021 2104 JAG 04/01/2021 2234 87671 1 (Chloride) 300.0 1 04/01/2021 1951 AMR 87782 1 (CO2 (calcula) SM 4500-CO2 D 1 04/08/2021 2153 DAK 1 (COD) SM 5220D-2011 1 04/02/2021 1627 AMR 87813 1 (Nitrate - N) 300.0 1 04/01/2021 1951 AMR 87774 1 (Sulfate) 300.0 1 04/01/2021 1951 AMR 87779 1 (Sulfide) SM 4500-S2 F-2011 1 04/06/2021 1907 GDC 88171 1 (TOC) SM 531OC-2011 1 04/02/2021 0615 AAB 87678 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 38 20 20 mg CaCO3/L 1 BOD, 5 day SM 521 OB-2011 2.0 U4 2.0 0.18 mg/L 1 Chloride 300.0 5.6 1.0 0.25 mg/L 1 CO2 (calculation) 124-38-9 SM 4500-CC2 D 110 27 27 mg/L 1 COD SM 5220D-2011 20 U 20 20 mg/L 1 Nitrate - N 300.0 0.77 0.020 0.0050 mg/L 1 Sulfate 300.0 1.0 U 1.0 0.25 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 1.0 U 1.0 0.99 mg/L 1 TOC SM 531OC-2011 1.0 U 1.0 1.0 mg/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 129 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-028 Description: MW-11 Matrix: Aqueous Date Sampled:03/31/2021 1230 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20212007 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 UL 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 130 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-028 Description: MW-11 Matrix: Aqueous Date Sampled:03/31/2021 1230 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20212007 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 104 70-130 93 70-130 105 70-130 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 131 of 269 Dissolved Gases Client:CDM Smith Laboratory ID:WD01004-028 Description: MW-11 Matrix: Aqueous Date Sampled:03/31/2021 1230 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 04/12/2021 1123 TML 88775 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 10 U 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 10 U 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 42 10 2.5 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 132 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-028 Description: MW-11 Matrix: Aqueous Date Sampled:03/31/2021 1230 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1713 CMS2 04/07/2021 1224 88215 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 133 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-028 Description: MW-11 Matrix: Aqueous Date Sampled:03/31/2021 1230 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1613 BNW Prep Date Batch 04/04/2021 0532 87861 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 52 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 2.3 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.0 U 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 2.6 J 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 5.5 J 10 2.5 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 134 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-029 Description: MW-8d Matrix: Aqueous Date Sampled:03/31/2021 1330 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20212029 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 UL 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 UL 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 135 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-029 Description: MW-8d Matrix: Aqueous Date Sampled:03/31/2021 1330 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20212029 BWS 88149 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 105 70-130 94 70-130 107 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 136 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-029 Description: MW-8d Matrix: Aqueous Date Sampled:03/31/2021 1330 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1721 CMS2 04/07/2021 1224 88215 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 137 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-029 Description: MW-8d Matrix: Aqueous Date Sampled:03/31/2021 1330 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1619 BNW Prep Date Batch 04/04/2021 0532 87861 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 1.5 J 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 35 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.21 J 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 4.8 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 3.2 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.5 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 1.3 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 6.1 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 8.4 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 138 of 269 Inorganic non-metals Client:CDM Smith Laboratory ID:WD01004-030 Description: MW-8 Matrix: Aqueous Date Sampled:03/31/2021 1345 Project Name: North Wake Unlined Landfill Date Received: 04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (Alkalinity @) SM 2320B-2011 1 04/08/2021 2200 DAK 88497 1 (BOD, 5 day) SM 521OB-2011 1 04/06/2021 2108 JAG 04/01/2021 2246 87671 1 (Chloride) 300.0 1 04/01/2021 2010 AMR 87782 1 (CO2 (calcula) SM 4500-CO2 D 1 04/08/2021 2200 DAK 1 (COD) SM 5220D-2011 1 04/02/2021 1627 AMR 87813 1 (Nitrate - N) 300.0 1 04/01/2021 2010 AMR 87774 2 (Nitrate - N) 300.0 5 04/07/2021 1650 AMR 88382 1 (Sulfate) 300.0 1 04/01/2021 2010 AMR 87779 1 (Sulfide) SM 4500-S2 F-2011 1 04/06/2021 1907 GDC 88171 1 (TOC) SM 531OC-2011 1 04/02/2021 0629 AAB 87678 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Alkalinity @ pH 4.5 su SM 2320B-2011 210 20 20 mg CaCO3/L 1 BOD, 5 day SM 521 OB-2011 2.0 U4 2.0 0.18 mg/L 1 Chloride 300.0 130 1.0 0.25 mg/L 1 CO2 (calculation) 124-38-9 SM 4500-CO2 D 280 27 27 mg/L 1 COD SM 5220D-2011 20 US 20 20 mg/L 1 Sulfate 300.0 1.0 1.0 0.25 mg/L 1 Nitrate - N 300.0 0.020 U 0.020 0.0050 mg/L 1 Sulfide 18496-25-8 SM 4500-S2 F-2 1.0 U 1.0 0.99 mg/L 1 Nitrate - N 300.0 0.10 UH 0.10 0.025 mg/L 2 TOC SM 531OC-2011 3.4 1.0 1.0 mg/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 139 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-030 Description: MW-8 Matrix: Aqueous Date Sampled:03/31/2021 1345 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20212051 BWS 88149 2 5030B 8260D 1 04/10/20210028 DJG 88591 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 7.9 HJ 10 4.0 ug/L 2 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.62 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.40 J 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 UL 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 1.8 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.44 J 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1, 1 -Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis-1,2-Dichloroethene 156-59-2 8260D 23 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 140 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-030 Description: MW-8 Matrix: Aqueous Date Sampled:03/31/2021 1345 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/06/20212051 BWS 88149 2 5030B 8260D 1 04/10/20210028 DJG 88591 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Run 2 Acceptance Surrogate Q % Recovery Limits Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 101 70-130 H 105 70-130 92 70-130 H 101 70-130 102 70-130 H 107 70-130 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 141 of 269 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:WD01004-030 Description: MW-8 Matrix: Aqueous Date Sampled:03/31/2021 1345 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 04/07/2021 1616 TML 88444 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 1.3 J 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 112 40-170 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 142 of 269 Dissolved Gases Client:CDM Smith Laboratory ID:WD01004-030 Description: MW-8 Matrix: Aqueous Date Sampled:03/31/2021 1345 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 RSK - 175 1 04/12/2021 1139 TML 88775 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Ethane 74-84-0 RSK - 175 10 U 10 2.5 ug/L 1 Ethene 74-85-1 RSK - 175 10 U 10 2.5 ug/L 1 Methane 74-82-8 RSK - 175 150 10 2.5 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 143 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-030 Description: MW-8 Matrix: Aqueous Date Sampled:03/31/2021 1345 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1724 CMS2 04/07/2021 1224 88215 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 144 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-030 Description: MW-8 Matrix: Aqueous Date Sampled:03/31/2021 1345 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1625 BNW Prep Date Batch 04/04/2021 0532 87861 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 63 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.63 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 13 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 2.3 J 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 3.3 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 0.51 J 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 6.4 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 8.9 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 11 10 2.5 ug/L 1 Footnote(s): 4-Blank depletion > 0.20 mg/L LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 145 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-031 Description: SW-7 Matrix: Aqueous Date Sampled:03/31/2021 1400 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/07/20210428 CJL2 88182 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 146 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-031 Description: SW-7 Matrix: Aqueous Date Sampled:03/31/2021 1400 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/07/20210428 CJL2 88182 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 111 70-130 103 70-130 112 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 147 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-031 Description: SW-7 Matrix: Aqueous Date Sampled:03/31/2021 1400 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1727 CMS2 04/07/2021 1224 88215 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 148 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-031 Description: SW-7 Matrix: Aqueous Date Sampled:03/31/2021 1400 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1642 BNW Prep Date Batch 04/04/2021 0532 87861 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 27 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 1.4 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.0 U 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 10 U 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 149 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-032 Description: SW-8 Matrix: Aqueous Date Sampled:03/31/2021 1405 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/07/20210453 CJL2 88182 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 150 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-032 Description: SW-8 Matrix: Aqueous Date Sampled:03/31/2021 1405 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/07/20210453 CJL2 88182 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 113 70-130 103 70-130 113 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 151 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-032 Description: SW-8 Matrix: Aqueous Date Sampled:03/31/2021 1405 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1729 CMS2 04/07/2021 1224 88215 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 152 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-032 Description: SW-8 Matrix: Aqueous Date Sampled:03/31/2021 1405 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1648 BNW Prep Date Batch 04/04/2021 0532 87861 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 27 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 5.0 U 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.0 U 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 10 U 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 153 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-033 Description: SW-3 Matrix: Aqueous Date Sampled:03/31/2021 1435 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/07/20210518 CJL2 88182 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 154 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-033 Description: SW-3 Matrix: Aqueous Date Sampled:03/31/2021 1435 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/07/20210518 CJL2 88182 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 100 70-130 103 70-130 111 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 155 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-033 Description: SW-3 Matrix: Aqueous Date Sampled:03/31/2021 1435 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1737 CMS2 04/07/2021 1224 88215 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 156 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-033 Description: SW-3 Matrix: Aqueous Date Sampled:03/31/2021 1435 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1654 BNW Prep Date Batch 04/04/2021 0532 87861 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 31 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 5.0 U 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.0 U 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 2.5 J 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 157 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-034 Description: SW-2 Matrix: Aqueous Date Sampled:03/31/2021 1520 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/07/20210543 CJL2 88182 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 4.0 J 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 158 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-034 Description: SW-2 Matrix: Aqueous Date Sampled:03/31/2021 1520 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/07/20210543 CJL2 88182 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 111 70-130 102 70-130 113 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 159 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-034 Description: SW-2 Matrix: Aqueous Date Sampled:03/31/2021 1520 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1740 CMS2 04/07/2021 1224 88215 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 160 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-034 Description: SW-2 Matrix: Aqueous Date Sampled:03/31/2021 1520 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1700 BNW Prep Date Batch 04/04/2021 0532 87861 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 44 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 2.9 J 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.8 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.6 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.7 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 11 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 161 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-035 Description: DUP Matrix: Aqueous Date Sampled:03/31/2021 0700 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/07/20210607 CJL2 88182 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 162 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-035 Description: DUP Matrix: Aqueous Date Sampled:03/31/2021 0700 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/07/20210607 CJL2 88182 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 110 70-130 104 70-130 110 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 163 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-035 Description: DUP Matrix: Aqueous Date Sampled:03/31/2021 0700 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1743 CMS2 04/07/2021 1224 88215 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 164 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-035 Description: DUP Matrix: Aqueous Date Sampled:03/31/2021 0700 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/05/2021 1706 BNW Prep Date Batch 04/04/2021 0532 87861 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.6 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 35 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.23 J 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 6.9 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 4.7 J 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.8 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 2.5 J 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 8.4 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 12 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 165 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-036 Description: EQ BLANK Matrix: Aqueous Date Sampled:03/31/2021 1540 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/07/20210045 CJL2 88182 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 4.3 J 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 7.7 J 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 166 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-036 Description: EQ BLANK Matrix: Aqueous Date Sampled:03/31/2021 1540 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/07/20210045 CJL2 88182 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 111 70-130 102 70-130 110 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 167 of 269 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:WD01004-036 Description: EQ BLANK Matrix: Aqueous Date Sampled:03/31/2021 1540 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 04/05/2021 2053 CJL2 88039 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 3.0 U 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 113 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 168 of 269 CVAA Client:CDM Smith Laboratory ID:WD01004-036 Description: EQ BLANK Matrix: Aqueous Date Sampled:03/31/2021 1540 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 7470A 1 04/07/2021 1745 CMS2 04/07/2021 1224 88215 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Mercury 7439-97-6 7470A 0.00020 U 0.00020 0.000091 mg/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 169 of 269 ICP-MS Metals Client:CDM Smith Laboratory ID:WD01004-036 Description: EQ BLANK Matrix: Aqueous Date Sampled:03/31/2021 1540 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method 1 3005A Analytical Method Dilution Analysis Date Analyst 6020B 1 04/12/2021 1946 BPK Prep Date Batch 04/09/2021 0402 88336 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Antimony 7440-36-0 6020B 2.0 U 2.0 0.50 ug/L 1 Arsenic 7440-38-2 6020B 2.0 U 2.0 1.3 ug/L 1 Barium 7440-39-3 6020B 5.0 U 5.0 1.3 ug/L 1 Beryllium 7440-41-7 6020B 0.40 U 0.40 0.15 ug/L 1 Cadmium 7440-43-9 6020B 0.50 U 0.50 0.13 ug/L 1 Chromium 7440-47-3 6020B 5.0 U 5.0 1.3 ug/L 1 Cobalt 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 Copper 7440-50-8 6020B 5.0 U 5.0 1.3 ug/L 1 Lead 7439-92-1 6020B 1.0 U 1.0 0.25 ug/L 1 Nickel 7440-02-0 6020B 5.0 U 5.0 1.3 ug/L 1 Selenium 7782-49-2 6020B 5.0 U 5.0 1.3 ug/L 1 Silver 7440-22-4 6020B 1.0 U 1.0 0.25 ug/L 1 Thallium 7440-28-0 6020B 0.50 U 0.50 0.15 ug/L 1 Vanadium 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 Zinc 7440-66-6 6020B 10 U 10 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 170 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-037 Description: TRIP BLANK Matrix: Aqueous Date Sampled:03/31/2021 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/07/20210110 CJL2 88182 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Acetone 67-64-1 8260D 10 U 10 4.0 ug/L 1 Acrylonitrile 107-13-1 8260D 5.0 U 5.0 0.80 ug/L 1 Benzene 71-43-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromochloromethane 74-97-5 8260D 0.50 U 0.50 0.40 ug/L 1 Bromodichloromethane 75-27-4 8260D 0.50 U 0.50 0.40 ug/L 1 Bromoform 75-25-2 8260D 0.50 U 0.50 0.40 ug/L 1 Bromomethane (Methyl bromide) 74-83-9 8260D 0.50 U 0.50 0.40 ug/L 1 2-Butanone (MEK) 78-93-3 8260D 10 U 10 2.0 ug/L 1 Carbon disulfide 75-15-0 8260D 0.50 U 0.50 0.40 ug/L 1 Carbon tetrachloride 56-23-5 8260D 0.50 U 0.50 0.40 ug/L 1 Chlorobenzene 108-90-7 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroethane 75-00-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloroform 67-66-3 8260D 0.50 U 0.50 0.40 ug/L 1 Chloromethane (Methyl chloride) 74-87-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromo-3-chloropropane (DBCP) 96-12-8 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromochloromethane 124-48-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dibromoethane (EDB) 106-93-4 8260D 0.50 U 0.50 0.40 ug/L 1 Dibromomethane (Methylene bromide) 74-95-3 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,4-Dichloro-2-butene 110-57-6 8260D 2.0 U 2.0 0.40 ug/L 1 1,2-Dichlorobenzene 95-50-1 8260D 0.50 U 0.50 0.40 ug/L 1 1,4-Dichlorobenzene 106-46-7 8260D 0.50 U 0.50 0.40 ug/L 1 Dichlorodifluoromethane 75-71-8 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethane 75-34-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloroethane 107-06-2 8260D 0.50 U 0.50 0.40 ug/L 1 1,1-Dichloroethene 75-35-4 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,2-Dichloroethene 156-59-2 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,2-Dichloroethene 156-60-5 8260D 0.50 U 0.50 0.40 ug/L 1 1,2-Dichloropropane 78-87-5 8260D 0.50 U 0.50 0.40 ug/L 1 cis- 1,3-Dichloropropene 10061-01-5 8260D 0.50 U 0.50 0.40 ug/L 1 trans- 1,3-Dichloropropene 10061-02-6 8260D 0.50 U 0.50 0.40 ug/L 1 Ethylbenzene 100-41-4 8260D 0.50 U 0.50 0.40 ug/L 1 2-Hexanone 591-78-6 8260D 10 U 10 2.0 ug/L 1 Methyl iodide (lodomethane) 74-88-4 8260D 5.0 U 5.0 0.40 ug/L 1 4-Methyl-2-pentanone 108-10-1 8260D 10 U 10 2.0 ug/L 1 Methylene chloride 75-09-2 8260D 0.50 U 0.50 0.40 ug/L 1 Styrene 100-42-5 8260D 0.50 U 0.50 0.41 ug/L 1 1,1,1,2-Tetrachloroethane 630-20-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2,2-Tetrachloroethane 79-34-5 8260D 0.50 U 0.50 0.40 ug/L 1 Tetrachloroethene 127-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Toluene 108-88-3 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,1-Trichloroethane 71-55-6 8260D 0.50 U 0.50 0.40 ug/L 1 1,1,2-Trichloroethane 79-00-5 8260D 0.50 U 0.50 0.40 ug/L 1 Trichloroethene 79-01-6 8260D 0.50 U 0.50 0.40 ug/L 1 Trichlorofluoromethane 75-69-4 8260D 0.50 U 0.50 0.40 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 171 of 269 Volatile Organic Compounds by GC/MS Client:CDM Smith Laboratory ID:WD01004-037 Description: TRIP BLANK Matrix: Aqueous Date Sampled:03/31/2021 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D 1 04/07/20210110 CJL2 88182 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,2,3-Trichloropropane 96-18-4 8260D 0.50 U 0.50 0.40 ug/L 1 Vinyl acetate 108-05-4 8260D 5.0 U 5.0 1.2 ug/L 1 Vinyl chloride 75-01-4 8260D 0.50 U 0.50 0.40 ug/L 1 Xylenes (total) 1330-20-7 8260D 1.0 U 1.0 0.40 ug/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits Bromofluorobenzene 1,2-Dichloroethane-d4 Toluene-d8 112 70-130 106 70-130 109 70-130 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 172 of 269 Volatile Organic Compounds by GC/MS (SIM) Client:CDM Smith Laboratory ID:WD01004-037 Description: TRIP BLANK Matrix: Aqueous Date Sampled:03/31/2021 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 5030B 8260D (SIM) 1 04/05/2021 2117 CJL2 88039 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run 1,4-Dioxane 123-91-1 8260D (SIM) 3.0 U 3.0 1.0 ug/L 1 Run Acceptance Surrogate Q % Recovery Limits 1,2-Dichloroethane-d4 114 40-170 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 173 of 269 QC Summary Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: WD01004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 174 of 269 Inorganic non-metals - BOD Blank and GGA Matrix: Aqueous Batch: 87671 SCF: 0.6 Analytical Method: SM 521 OB-2011 SCF Range: 0.6 - 1.0 Result Avg. Result Sample ID Depl Avg. Depl (mg/L) (mg/L) Q Limit Prep Date Analysis Date WQ87671-041 (Blank) 0.12 4 0.2 04/01/2021 2140 04/06/2021 2041 WQ87671-141 (Blank) 0.35 4 0.2 04/01/2021 2140 04/06/2021 2040 WQ87671-241 (Blank) 0.38 0.28 4 0.2 04/01/2021 2140 04/06/2021 2041 WQ87671-035 (GGA) 164.2 41 167.5-228.5 04/01/2021 2146 04/06/2021 2044 WQ87671-135 (GGA) 183.7 4 167.5-228.5 04/01/2021 2146 04/06/2021 2044 WQ87671-235 (GGA) 190.2 179.3 4 167.5-228.5 04/01/2021 2146 04/06/2021 2044 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 175 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - MB Sample ID: WQ87676-001 Matrix: Aqueous Batch:87676 Analytical Method: SM 2540C-2011 Parameter Result Q Dil LOQ DL Units Analysis Date TDS 25 U 1 25 25 mg/L 04/01/2021 2159 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 176 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - LCS Sample ID: WQ87676-002 Matrix: Aqueous Batch:87676 Analytical Method: SM 2540C-2011 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date TDS 1500 1500 1 97 90-110 04/01/2021 2159 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 177 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - MB Sample ID: WQ87678-001 Matrix: Aqueous Batch:87678 Analytical Method: SM 531 OC-2011 Parameter Result Q Dil LOQ DL Units Analysis Date TOC 1.0 U 1 1.0 1.0 mg/L 04/02/2021 0033 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 178 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - LCS Sample ID: WQ87678-002 Matrix: Aqueous Batch:87678 Analytical Method: SM 531 OC-2011 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date TOC 20 20 1 99 90-110 04/02/2021 0046 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 179 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - MS Sample ID: WD01004-012MS Matrix: Aqueous Batch:87678 Analytical Method: SM 531 OC-2011 Sample Spike Amount Amount Result %Rec Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date TOC 2.7 50 55 1 105 70-130 04/02/2021 0443 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 180 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - MSD Sample ID: WD01004-012MD Matrix: Aqueous Batch:87678 Analytical Method: SM 531 OC-2011 Sample Spike Amount Amount Result %Rec % RPD Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date TOC 2.7 50 55 1 104 0.77 70-130 20 04/02/2021 0456 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 181 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - MB Sample ID: WQ87768-001 Matrix: Aqueous Batch:87768 Analytical Method: 300.0 Parameter Result Q Dil LOQ DL Units Analysis Date Chloride 1.0 U 1 1.0 0.25 mg/L 04/01/2021 0927 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 182 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - LCS Sample ID: WQ87768-002 Matrix: Aqueous Batch:87768 Analytical Method: 300.0 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Chloride 20 20 1 100 90-110 04/01/2021 1005 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 183 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - MB Sample ID: WQ87772-001 Matrix: Aqueous Batch:87772 Analytical Method: 300.0 Parameter Result Q Dil LOQ DL Units Analysis Date Sulfate 1.0 U 1 1.0 0.25 mg/L 04/01/2021 0927 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 184 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - LCS Sample ID: WQ87772-002 Matrix: Aqueous Batch:87772 Analytical Method: 300.0 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Sulfate 20 20 1 99 90-110 04/01/2021 1005 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 185 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - MB Sample ID: WQ87773-001 Matrix: Aqueous Batch:87773 Analytical Method: 300.0 Parameter Result Q Dil LOQ DL Units Analysis Date Nitrate - N 0.020 U 1 0.020 0.0050 mg/L 04/01/2021 0927 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 186 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - LCS Sample ID: WQ87773-002 Matrix: Aqueous Batch:87773 Analytical Method: 300.0 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Nitrate - N 0.80 0.78 1 98 90-110 04/01/2021 1005 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 187 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - MB Sample ID: WQ87774-001 Matrix: Aqueous Batch:87774 Analytical Method: 300.0 Parameter Result Q Dil LOQ DL Units Analysis Date Nitrate - N 0.020 U 1 0.020 0.0050 mg/L 04/01/2021 1701 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 188 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - LCS Sample ID: WQ87774-002 Matrix: Aqueous Batch:87774 Analytical Method: 300.0 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Nitrate - N 0.80 0.78 1 97 90-110 04/01/2021 1913 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 189 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - LCSD Sample ID: WQ87774-003 Matrix: Aqueous Batch:87774 Analytical Method: 300.0 Spike Amount Result %Rec % RPD Parameter (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date Nitrate - N 0.80 0.78 1 98 0.22 90-110 20 04/01/2021 1932 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 190 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - MB Sample ID: WQ87779-001 Matrix: Aqueous Batch: 87779 Analytical Method: 300.0 Parameter Result Q Dil LOQ DL Units Analysis Date Sulfate 1.0 U 1 1.0 0.25 mg/L 04/01/2021 1701 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 191 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - LCS Sample ID: WQ87779-002 Matrix: Aqueous Batch: 87779 Analytical Method: 300.0 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Sulfate 20 19 1 97 90-110 04/01/2021 1913 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 192 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - LCSD Sample ID: WQ87779-003 Matrix: Aqueous Batch: 87779 Analytical Method: 300.0 Spike Amount Result %Rec % RPD Parameter (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date Sulfate 20 19 1 97 0.20 90-110 20 04/01/2021 1932 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 193 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - MB Sample ID: WQ87782-001 Matrix: Aqueous Batch:87782 Analytical Method: 300.0 Parameter Result Q Dil LOQ DL Units Analysis Date Chloride 1.0 U 1 1.0 0.25 mg/L 04/01/2021 1701 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 194 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - LCS Sample ID: WQ87782-002 Matrix: Aqueous Batch:87782 Analytical Method: 300.0 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Chloride 20 20 1 99 90-110 04/01/2021 1913 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 195 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - LCSD Sample ID: WQ87782-003 Matrix: Aqueous Batch:87782 Analytical Method: 300.0 Spike Amount Result %Rec % RPD Parameter (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date Chloride 20 20 1 99 0.24 90-110 20 04/01/2021 1932 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 196 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - MB Sample ID: WQ87813-001 Matrix: Aqueous Batch: 87813 Analytical Method: SM 5220D-2011 Parameter Result Q Dil LOQ DL Units Analysis Date COD 20 U 1 20 20 mg/L 04/02/2021 1623 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 197 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - LCS Sample ID: WQ87813-002 Matrix: Aqueous Batch: 87813 Analytical Method: SM 5220D-2011 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date COD 40 40 1 99 95-105 04/02/2021 1623 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 198 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - MS Sample ID: WD01004-03OMS Matrix: Aqueous Batch: 87813 Analytical Method: SM 5220D-2011 Sample Spike Amount Amount Result %Rec Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date COD 0.0 40 52 N 1 131 90-110 04/02/2021 1628 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 199 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - MSD Sample ID: WD01004-03OMD Matrix: Aqueous Batch: 87813 Analytical Method: SM 5220D-2011 Sample Spike Amount Amount Result %Rec % RPD Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date COD 0.0 40 51 N 1 127 3.1 90-110 20 04/02/2021 1628 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 200 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - MB Sample ID: WQ88140-001 Matrix: Aqueous Batch: 88140 Analytical Method: SM 531 OC-2011 Parameter Result Q Dil LOQ DL Units Analysis Date TOC 1.0 U 1 1.0 1.0 mg/L 04/06/2021 1724 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 201 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - LCS Sample ID: WQ88140-002 Matrix: Aqueous Batch: 88140 Analytical Method: SM 531 OC-2011 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date TOC 20 20 1 101 90-110 04/06/2021 1737 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 202 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - MB Sample ID: WQ88171-001 Matrix: Aqueous Batch: 88171 Analytical Method: SM 4500-S2 F-2011 Parameter Result Q Dil LOQ DL Units Analysis Date Sulfide 1.0 U 1 1.0 0.99 mg/L 04/06/2021 1907 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 203 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - LCS Sample ID: WQ88171-002 Matrix: Aqueous Batch: 88171 Analytical Method: SM 4500-S2 F-2011 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Sulfide 10 9.0 1 90 80-120 04/06/2021 1907 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 204 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - LCSD Sample ID: WQ88171-003 Matrix: Aqueous Batch: 88171 Analytical Method: SM 4500-S2 F-2011 Spike Amount Result %Rec % RPD Parameter (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date Sulfide 10 9.0 1 90 0.00 80-120 20 04/06/2021 1907 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 205 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - MS Sample ID: WD01004-006MS Matrix: Aqueous Batch: 88171 Analytical Method: SM 4500-S2 F-2011 Sample Spike Amount Amount Result %Rec Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Sulfide 0.0 10 7.7 1 77 70-130 04/06/2021 1907 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 206 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - MSD Sample ID: WD01004-006MD Matrix: Aqueous Batch: 88171 Analytical Method: SM 4500-S2 F-2011 Sample Spike Amount Amount Result %Rec % RPD Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date Sulfide 0.0 10 7.3 1 73 5.2 70-130 20 04/06/2021 1907 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 207 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - MB Sample ID: WQ88382-001 Matrix: Aqueous Batch:88382 Analytical Method: 300.0 Parameter Result Q Dil LOQ DL Units Analysis Date Nitrate - N 0.0065 J 1 0.020 0.0050 mg/L 04/07/2021 1142 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 208 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - LCS Sample ID: WQ88382-002 Matrix: Aqueous Batch:88382 Analytical Method: 300.0 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Nitrate - N 0.80 0.78 1 97 90-110 04/07/2021 1216 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 209 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - LCS Sample ID: WQ88496-002 Matrix: Aqueous Batch: 88496 Analytical Method: SM 2320B-2011 Spike Amount Result %Rec Parameter (mg CaCO3/L) (mg CaCO3/L) Q Dil % Rec Limit Analysis Date Alkalinity @ pH 4.5 su 100 100 1 101 90-110 04/08/2021 1851 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 210 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - MB Sample ID: WQ88497-001 Matrix: Aqueous Batch: 88497 Analytical Method: SM 2320B-2011 Parameter Result Q Dil LOQ DL Units Analysis Date Alkalinity @ pH 4.5 su 20 U 1 20 20 mg CaCO3/L 04/08/2021 2135 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 211 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - LCS Sample ID: WQ88497-002 Matrix: Aqueous Batch: 88497 Analytical Method: SM 2320B-2011 Spike Amount Result %Rec Parameter (mg CaCO3/L) (mg CaCO3/L) Q Dil % Rec Limit Analysis Date Alkalinity @ pH 4.5 su 100 100 1 100 90-110 04/08/2021 2131 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 212 of 269 QC Data for Lot Number: WD01004 Inorganic non-metals - Duplicate Sample ID: WD01004-030DU Matrix: Aqueous Batch: 88497 Analytical Method: SM 2320B-2011 Sample Amount Result %RPD Parameter (mg CaCO3/L) (mg CaCO3/L) Q Dil % RPD Limit Analysis Date Alkalinity @ pH 4.5 su 210 220 1 0.85 20 04/08/2021 2207 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 213 of 269 QC Data for Lot Number: WD01004 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ88002-001 Matrix: Aqueous Batch: 88002 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone 10 U 1 10 4.0 ug/L 04/05/2021 1354 Acrylonitrile 5.0 U 1 5.0 0.80 ug/L 04/05/2021 1354 Benzene 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 Bromochloromethane 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 Bromodichloromethane 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 Bromoform 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 Bromomethane (Methyl bromide) 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 2-Butanone (MEK) 10 U 1 10 2.0 ug/L 04/05/2021 1354 Carbon disulfide 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 Carbon tetrachloride 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 Chlorobenzene 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 Chloroethane 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 Chloroform 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 Chloromethane (Methyl chloride) 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 1,2-Dibromo-3-chloropropane (DBCP) 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 Dibromochloromethane 0.50 u 1 0.50 0.40 ug/L 04/05/2021 1354 1,2-Dibromoethane (EDB) 0.50 u 1 0.50 0.40 ug/L 04/05/2021 1354 Dibromomethane (Methylene bromide) 0.50 u 1 0.50 0.40 ug/L 04/05/2021 1354 trans- 1,4-Dichloro-2-butene 2.0 u 1 2.0 0.40 ug/L 04/05/2021 1354 1,2-Dichlorobenzene 0.50 u 1 0.50 0.40 ug/L 04/05/2021 1354 1,4-Dichlorobenzene 0.50 u 1 0.50 0.40 ug/L 04/05/2021 1354 Dichlorodifluoromethane 0.50 u 1 0.50 0.40 ug/L 04/05/2021 1354 1,1-Dichloroethane 0.50 u 1 0.50 0.40 ug/L 04/05/2021 1354 1,2-Dichloroethane 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 1,1-Dichloroethene 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 cis- 1,2-Dichloroethene 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 trans- 1,2-Dichloroethene 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 1,2-Dichloropropane 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 cis- 1,3-Dichloropropene 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 trans- 1,3-Dichloropropene 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 Ethylbenzene 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 2-Hexanone 10 U 1 10 2.0 ug/L 04/05/2021 1354 Methyl iodide (lodomethane) 5.0 U 1 5.0 0.40 ug/L 04/05/2021 1354 4-Methyl-2-pentanone 10 U 1 10 2.0 ug/L 04/05/2021 1354 Methylene chloride 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 Styrene 0.50 U 1 0.50 0.41 ug/L 04/05/2021 1354 1,1,1,2-Tetrachloroethane 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 1,1,2,2-Tetrachloroethane 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 Tetrachloroethene 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 Toluene 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 1,1,1-Trichloroethane 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 1,1,2-Trichloroethane 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 Trichloroethene 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 Trichlorofluoromethane 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 214 of 269 QC Data for Lot Number: WD01004 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ88002-001 Matrix: Aqueous Batch:88002 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date 1,2,3-Trichloropropane 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 Vinyl acetate 5.0 U 1 5.0 1.2 ug/L 04/05/2021 1354 Vinyl chloride 0.50 U 1 0.50 0.40 ug/L 04/05/2021 1354 Xylenes (total) 1.0 U 1 1.0 0.40 ug/L 04/05/2021 1354 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 105 70-130 1,2-Dichloroethane-d4 98 70-130 Toluene-d8 105 70-130 LOQ = Limit of Quantitation U = Not detected at or above the LOD N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: WD01004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 215 of 269 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ88002-002 Matrix: Aqueous Batch: 88002 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 120 1 120 60-140 04/05/2021 1105 Acrylonitrile 100 110 1 110 70-130 04/05/2021 1105 Benzene 50 53 1 107 70-130 04/05/2021 1105 Bromochloromethane 50 53 1 106 70-130 04/05/2021 1105 Bromodichloromethane 50 53 1 105 70-130 04/05/2021 1105 Bromoform 50 50 1 100 70-130 04/05/2021 1105 Bromomethane (Methyl bromide) 50 55 1 109 70-130 04/05/2021 1105 2-Butanone (MEK) 100 120 1 124 70-130 04/05/2021 1105 Carbon disulfide 50 56 1 111 70-130 04/05/2021 1105 Carbon tetrachloride 50 52 1 103 70-130 04/05/2021 1105 Chlorobenzene 50 52 1 103 70-130 04/05/2021 1105 Chloroethane 50 50 1 101 70-130 04/05/2021 1105 Chloroform 50 49 1 98 70-130 04/05/2021 1105 Chloromethane (Methyl chloride) 50 47 1 93 60-140 04/05/2021 1105 1,2-Dibromo-3-chloropropane (DBCP) 50 46 1 92 70-130 04/05/2021 1105 Dibromochloromethane 50 49 1 97 70-130 04/05/2021 1105 1,2-Dibromoethane (EDB) 50 54 1 108 70-130 04/05/2021 1105 Dibromomethane (Methylene bromide) 50 52 1 104 70-130 04/05/2021 1105 trans- 1,4-Dichloro-2-butene 50 41 1 82 70-130 04/05/2021 1105 1,2-Dichlorobenzene 50 53 1 105 70-130 04/05/2021 1105 1,4-Dichlorobenzene 50 51 1 102 70-130 04/05/2021 1105 Dichlorodifluoromethane 50 47 1 94 60-140 04/05/2021 1105 1,1-Dichloroethane 50 51 1 102 70-130 04/05/2021 1105 1,2-Dichloroethane 50 47 1 94 70-130 04/05/2021 1105 1,1-Dichloroethene 50 56 1 111 70-130 04/05/2021 1105 cis- 1,2-Dichloroethene 50 53 1 107 70-130 04/05/2021 1105 trans- 1,2-Dichloroethene 50 54 1 108 70-130 04/05/2021 1105 1,2-Dichloropropane 50 54 1 108 70-130 04/05/2021 1105 cis- 1,3-Dichloropropene 50 57 1 114 70-130 04/05/2021 1105 trans- 1,3-Dichloropropene 50 46 1 93 70-130 04/05/2021 1105 Ethylbenzene 50 54 1 107 70-130 04/05/2021 1105 2-Hexanone 100 93 1 93 70-130 04/05/2021 1105 Methyl iodide (lodomethane) 50 54 1 109 70-130 04/05/2021 1105 4-Methyl-2-pentanone 100 110 1 108 70-130 04/05/2021 1105 Methylene chloride 50 51 1 102 70-130 04/05/2021 1105 Styrene 50 57 1 114 70-130 04/05/2021 1105 1,1,1,2-Tetrachloroethane 50 56 1 111 70-130 04/05/2021 1105 1,1,2,2-Tetrachloroethane 50 53 1 106 70-130 04/05/2021 1105 Tetrachloroethene 50 52 1 104 70-130 04/05/2021 1105 Toluene 50 51 1 103 70-130 04/05/2021 1105 1,1,1-Trichloroethane 50 52 1 104 70-130 04/05/2021 1105 1,1,2-Trichloroethane 50 51 1 103 70-130 04/05/2021 1105 Trichloroethene 50 52 1 105 70-130 04/05/2021 1105 Trichlorofluoromethane 50 51 1 102 70-130 04/05/2021 1105 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 216 of 269 QC Data for Lot Number: WD01004 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ88002-002 Matrix: Aqueous Batch:88002 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,2,3-Trichloropropane 50 50 1 100 70-130 04/05/2021 1105 Vinyl acetate 50 50 1 101 60-140 04/05/2021 1105 Vinyl chloride 50 53 1 106 70-130 04/05/2021 1105 Xylenes (total) 100 110 1 111 70-130 04/05/2021 1105 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 94 70-130 1,2-Dichloroethane-d4 82 70-130 Toluene-d8 88 70-130 LOQ = Limit of Quantitation U = Not detected at or above the LOD N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: WD01004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 217 of 269 Volatile Organic Compounds by GC/MS (SIM) - MB Sample ID: WQ88039-001 Matrix: Aqueous Batch:88039 Prep Method: 5030E Analytical Method: 8260D (SIM) Parameter Result Q Dil LOQ DL Units Analysis Date 1,4-Dioxane 3.0 U 1 3.0 1.0 ug/L 04/05/2021 1939 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 111 40-170 U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 218 of 269 QC Data for Lot Number: WD01004 Volatile Organic Compounds by GC/MS (SIM) - LCS Sample ID: WQ88039-002 Matrix: Aqueous Batch:88039 Prep Method: 5030E Analytical Method: 8260D (SIM) Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,4-Dioxane 50 44 1 89 70-130 04/05/2021 1837 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 117 40-170 U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 219 of 269 QC Data for Lot Number: WD01004 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ88043-001 Matrix: Aqueous Batch: 88043 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone 10 U 1 10 4.0 ug/L 04/05/2021 2025 Acrylonitrile 5.0 U 1 5.0 0.80 ug/L 04/05/2021 2025 Benzene 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 Bromochloromethane 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 Bromodichloromethane 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 Bromoform 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 Bromomethane (Methyl bromide) 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 2-Butanone (MEK) 10 U 1 10 2.0 ug/L 04/05/2021 2025 Carbon disulfide 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 Carbon tetrachloride 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 Chlorobenzene 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 Chloroethane 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 Chloroform 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 Chloromethane (Methyl chloride) 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 1,2-Dibromo-3-chloropropane (DBCP) 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 Dibromochloromethane 0.50 u 1 0.50 0.40 ug/L 04/05/2021 2025 1,2-Dibromoethane (EDB) 0.50 u 1 0.50 0.40 ug/L 04/05/2021 2025 Dibromomethane (Methylene bromide) 0.50 u 1 0.50 0.40 ug/L 04/05/2021 2025 1,2-Dichlorobenzene 0.50 u 1 0.50 0.40 ug/L 04/05/2021 2025 1,4-Dichlorobenzene 0.50 u 1 0.50 0.40 ug/L 04/05/2021 2025 Dichlorodifluoromethane 0.50 u 1 0.50 0.40 ug/L 04/05/2021 2025 1,1-Dichloroethane 0.50 u 1 0.50 0.40 ug/L 04/05/2021 2025 1,2-Dichloroethane 0.50 u 1 0.50 0.40 ug/L 04/05/2021 2025 1,1-Dichloroethene 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 cis- 1,2-Dichloroethene 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 trans- 1,2-Dichloroethene 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 1,2-Dichloropropane 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 cis- 1,3-Dichloropropene 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 trans- 1,3-Dichloropropene 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 Ethylbenzene 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 2-Hexanone 10 U 1 10 2.0 ug/L 04/05/2021 2025 Methyl iodide (lodomethane) 5.0 U 1 5.0 0.40 ug/L 04/05/2021 2025 4-Methyl-2-pentanone 10 U 1 10 2.0 ug/L 04/05/2021 2025 Methylene chloride 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 Styrene 0.50 U 1 0.50 0.41 ug/L 04/05/2021 2025 1,1,1,2-Tetrachloroethane 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 1,1,2,2-Tetrachloroethane 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 Tetrachloroethene 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 Toluene 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 1,1,1-Trichloroethane 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 1,1,2-Trichloroethane 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 Trichloroethene 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 Trichlorofluoromethane 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 1,2,3-Trichloropropane 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 220 of 269 QC Data for Lot Number: WD01004 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ88043-001 Matrix: Aqueous Batch:88043 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Vinyl acetate 5.0 U 1 5.0 1.2 ug/L 04/05/2021 2025 Vinyl chloride 0.50 U 1 0.50 0.40 ug/L 04/05/2021 2025 Xylenes (total) 1.0 U 1 1.0 0.40 ug/L 04/05/2021 2025 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 97 70-130 1,2-Dichloroethane-d4 94 70-130 Toluene-d8 105 70-130 LOQ = Limit of Quantitation U = Not detected at or above the LOD N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: WD01004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 221 of 269 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ88043-002 Matrix: Aqueous Batch: 88043 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 110 1 112 60-140 04/05/2021 1920 Acrylonitrile 100 93 1 93 70-130 04/05/2021 1920 Benzene 50 47 1 95 70-130 04/05/2021 1920 Bromochloromethane 50 47 1 94 70-130 04/05/2021 1920 Bromodichloromethane 50 47 1 94 70-130 04/05/2021 1920 Bromoform 50 50 1 100 70-130 04/05/2021 1920 Bromomethane (Methyl bromide) 50 44 1 87 70-130 04/05/2021 1920 2-Butanone (MEK) 100 92 1 92 70-130 04/05/2021 1920 Carbon disulfide 50 52 1 105 70-130 04/05/2021 1920 Carbon tetrachloride 50 48 1 96 70-130 04/05/2021 1920 Chlorobenzene 50 48 1 95 70-130 04/05/2021 1920 Chloroethane 50 45 1 91 70-130 04/05/2021 1920 Chloroform 50 46 1 93 70-130 04/05/2021 1920 Chloromethane (Methyl chloride) 50 41 1 82 60-140 04/05/2021 1920 1,2-Dibromo-3-chloropropane (DBCP) 50 46 1 92 70-130 04/05/2021 1920 Dibromochloromethane 50 51 1 101 70-130 04/05/2021 1920 1,2-Dibromoethane (EDB) 50 49 1 98 70-130 04/05/2021 1920 Dibromomethane (Methylene bromide) 50 45 1 90 70-130 04/05/2021 1920 1,2-Dichlorobenzene 50 52 1 104 70-130 04/05/2021 1920 1,4-Dichlorobenzene 50 49 1 98 70-130 04/05/2021 1920 Dichlorodifluoromethane 50 41 1 83 60-140 04/05/2021 1920 1,1-Dichloroethane 50 48 1 97 70-130 04/05/2021 1920 1,2-Dichloroethane 50 45 1 90 70-130 04/05/2021 1920 1,1-Dichloroethene 50 50 1 99 70-130 04/05/2021 1920 cis- 1,2-Dichloroethene 50 47 1 94 70-130 04/05/2021 1920 trans- 1,2-Dichloroethene 50 48 1 96 70-130 04/05/2021 1920 1,2-Dichloropropane 50 47 1 95 70-130 04/05/2021 1920 cis- 1,3-Dichloropropene 50 48 1 95 70-130 04/05/2021 1920 trans- 1,3-Dichloropropene 50 50 1 99 70-130 04/05/2021 1920 Ethylbenzene 50 48 1 97 70-130 04/05/2021 1920 2-Hexanone 100 99 1 99 70-130 04/05/2021 1920 Methyl iodide (lodomethane) 50 48 1 95 70-130 04/05/2021 1920 4-Methyl-2-pentanone 100 94 1 94 70-130 04/05/2021 1920 Methylene chloride 50 48 1 95 70-130 04/05/2021 1920 Styrene 50 49 1 99 70-130 04/05/2021 1920 1,1,1,2-Tetrachloroethane 50 49 1 99 70-130 04/05/2021 1920 1,1,2,2-Tetrachloroethane 50 51 1 102 70-130 04/05/2021 1920 Tetrachloroethene 50 50 1 99 70-130 04/05/2021 1920 Toluene 50 50 1 99 70-130 04/05/2021 1920 1,1,1-Trichloroethane 50 48 1 96 70-130 04/05/2021 1920 1,1,2-Trichloroethane 50 49 1 99 70-130 04/05/2021 1920 Trichloroethene 50 46 1 92 70-130 04/05/2021 1920 Trichlorofluoromethane 50 46 1 93 70-130 04/05/2021 1920 1,2,3-Trichloropropane 50 50 1 100 70-130 04/05/2021 1920 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 222 of 269 QC Data for Lot Number: WD01004 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ88043-002 Matrix: Aqueous Batch:88043 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Vinyl acetate 50 47 1 94 60-140 04/05/2021 1920 Vinyl chloride 50 43 1 87 70-130 04/05/2021 1920 Xylenes (total) 100 99 1 99 70-130 04/05/2021 1920 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 99 70-130 1,2-Dichloroethane-d4 87 70-130 Toluene-d8 96 70-130 LOQ = Limit of Quantitation U = Not detected at or above the LOD N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: WD01004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 223 of 269 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ88149-001 Matrix: Aqueous Batch: 88149 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone 10 U 1 10 4.0 ug/L 04/06/2021 1247 Acrylonitrile 5.0 U 1 5.0 0.80 ug/L 04/06/2021 1247 Benzene 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 Bromochloromethane 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 Bromodichloromethane 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 Bromoform 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 Bromomethane (Methyl bromide) 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 2-Butanone (MEK) 10 U 1 10 2.0 ug/L 04/06/2021 1247 Carbon disulfide 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 Carbon tetrachloride 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 Chlorobenzene 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 Chloroethane 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 Chloroform 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 Chloromethane (Methyl chloride) 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 1,2-Dibromo-3-chloropropane (DBCP) 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 Dibromochloromethane 0.50 u 1 0.50 0.40 ug/L 04/06/2021 1247 1,2-Dibromoethane (EDB) 0.50 u 1 0.50 0.40 ug/L 04/06/2021 1247 Dibromomethane (Methylene bromide) 0.50 u 1 0.50 0.40 ug/L 04/06/2021 1247 trans- 1,4-Dichloro-2-butene 2.0 u 1 2.0 0.40 ug/L 04/06/2021 1247 1,2-Dichlorobenzene 0.50 u 1 0.50 0.40 ug/L 04/06/2021 1247 1,4-Dichlorobenzene 0.50 u 1 0.50 0.40 ug/L 04/06/2021 1247 Dichlorodifluoromethane 0.50 u 1 0.50 0.40 ug/L 04/06/2021 1247 1,1-Dichloroethane 0.50 u 1 0.50 0.40 ug/L 04/06/2021 1247 1,2-Dichloroethane 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 1,1-Dichloroethene 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 cis- 1,2-Dichloroethene 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 trans- 1,2-Dichloroethene 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 1,2-Dichloropropane 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 cis- 1,3-Dichloropropene 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 trans- 1,3-Dichloropropene 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 Ethylbenzene 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 2-Hexanone 10 U 1 10 2.0 ug/L 04/06/2021 1247 Methyl iodide (lodomethane) 5.0 U 1 5.0 0.40 ug/L 04/06/2021 1247 4-Methyl-2-pentanone 10 U 1 10 2.0 ug/L 04/06/2021 1247 Methylene chloride 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 Styrene 0.50 U 1 0.50 0.41 ug/L 04/06/2021 1247 1,1,1,2-Tetrachloroethane 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 1,1,2,2-Tetrachloroethane 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 Tetrachloroethene 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 Toluene 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 1,1,1-Trichloroethane 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 1,1,2-Trichloroethane 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 Trichloroethene 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 Trichlorofluoromethane 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 224 of 269 QC Data for Lot Number: WD01004 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ88149-001 Matrix: Aqueous Batch: 88149 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date 1,2,3-Trichloropropane 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 Vinyl acetate 5.0 U 1 5.0 1.2 ug/L 04/06/2021 1247 Vinyl chloride 0.50 U 1 0.50 0.40 ug/L 04/06/2021 1247 Xylenes (total) 1.0 U 1 1.0 0.40 ug/L 04/06/2021 1247 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 102 70-130 1,2-Dichloroethane-d4 94 70-130 Toluene-d8 105 70-130 LOQ = Limit of Quantitation U = Not detected at or above the LOD N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: WD01004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 225 of 269 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ88149-002 Matrix: Aqueous Batch: 88149 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 150 N 1 146 60-140 04/06/2021 1139 Acrylonitrile 100 95 1 95 70-130 04/06/2021 1139 Benzene 50 46 1 92 70-130 04/06/2021 1139 Bromochloromethane 50 47 1 95 70-130 04/06/2021 1139 Bromodichloromethane 50 48 1 96 70-130 04/06/2021 1139 Bromoform 50 53 1 105 70-130 04/06/2021 1139 Bromomethane (Methyl bromide) 50 46 1 93 70-130 04/06/2021 1139 2-Butanone (MEK) 100 100 1 101 70-130 04/06/2021 1139 Carbon disulfide 50 46 1 92 70-130 04/06/2021 1139 Carbon tetrachloride 50 46 1 93 70-130 04/06/2021 1139 Chlorobenzene 50 49 1 97 70-130 04/06/2021 1139 Chloroethane 50 48 1 96 70-130 04/06/2021 1139 Chloroform 50 46 1 91 70-130 04/06/2021 1139 Chloromethane (Methyl chloride) 50 44 1 87 60-140 04/06/2021 1139 1,2-Dibromo-3-chloropropane (DBCP) 50 54 1 108 70-130 04/06/2021 1139 Dibromochloromethane 50 52 1 104 70-130 04/06/2021 1139 1,2-Dibromoethane (EDB) 50 51 1 101 70-130 04/06/2021 1139 Dibromomethane (Methylene bromide) 50 44 1 89 70-130 04/06/2021 1139 trans- 1,4-Dichloro-2-butene 50 35 N 1 69 70-130 04/06/2021 1139 1,2-Dichlorobenzene 50 55 1 111 70-130 04/06/2021 1139 1,4-Dichlorobenzene 50 51 1 102 70-130 04/06/2021 1139 Dichlorodifluoromethane 50 52 1 104 60-140 04/06/2021 1139 1,1-Dichloroethane 50 46 1 91 70-130 04/06/2021 1139 1,2-Dichloroethane 50 46 1 92 70-130 04/06/2021 1139 1,1-Dichloroethene 50 44 1 89 70-130 04/06/2021 1139 cis- 1,2-Dichloroethene 50 45 1 91 70-130 04/06/2021 1139 trans- 1,2-Dichloroethene 50 45 1 89 70-130 04/06/2021 1139 1,2-Dichloropropane 50 47 1 93 70-130 04/06/2021 1139 cis- 1,3-Dichloropropene 50 47 1 93 70-130 04/06/2021 1139 trans- 1,3-Dichloropropene 50 53 1 107 70-130 04/06/2021 1139 Ethylbenzene 50 50 1 100 70-130 04/06/2021 1139 2-Hexanone 100 94 1 94 70-130 04/06/2021 1139 Methyl iodide (lodomethane) 50 44 1 88 70-130 04/06/2021 1139 4-Methyl-2-pentanone 100 95 1 95 70-130 04/06/2021 1139 Methylene chloride 50 45 1 90 70-130 04/06/2021 1139 Styrene 50 50 1 100 70-130 04/06/2021 1139 1,1,1,2-Tetrachloroethane 50 53 1 105 70-130 04/06/2021 1139 1,1,2,2-Tetrachloroethane 50 54 1 107 70-130 04/06/2021 1139 Tetrachloroethene 50 51 1 103 70-130 04/06/2021 1139 Toluene 50 50 1 100 70-130 04/06/2021 1139 1,1,1-Trichloroethane 50 45 1 91 70-130 04/06/2021 1139 1,1,2-Trichloroethane 50 51 1 103 70-130 04/06/2021 1139 Trichloroethene 50 46 1 93 70-130 04/06/2021 1139 Trichlorofluoromethane 50 47 1 93 70-130 04/06/2021 1139 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 226 of 269 QC Data for Lot Number: WD01004 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ88149-002 Matrix: Aqueous Batch: 88149 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,2,3-Trichloropropane 50 53 1 105 70-130 04/06/2021 1139 Vinyl acetate 50 46 1 91 60-140 04/06/2021 1139 Vinyl chloride 50 46 1 91 70-130 04/06/2021 1139 Xylenes (total) 100 100 1 100 70-130 04/06/2021 1139 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 99 70-130 1,2-Dichloroethane-d4 86 70-130 Toluene-d8 97 70-130 LOQ = Limit of Quantitation U = Not detected at or above the LOD N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: WD01004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 227 of 269 Volatile Organic Compounds by GC/MS - Duplicate Sample ID: WD01004-011DU Matrix: Aqueous Batch: 88149 Prep Method: 5030E Analytical Method: 8260D Sample Amount Result %RPD Parameter (ug/L) (ug/L) Q Dil % RPD Limit Analysis Date Acetone 10 (U) 10 U 1 0.00 20 04/06/2021 2114 Acrylonitrile 5.0 (U) 5.0 U 1 0.00 20 04/06/2021 2114 Benzene 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 Bromochloromethane 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 Bromodichloromethane 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 Bromoform 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 Bromomethane (Methyl bromide) 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 2-Butanone (MEK) 10 (U) 10 U 1 0.00 20 04/06/2021 2114 Carbon disulfide 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 Carbon tetrachloride 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 Chlorobenzene 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 Chloroethane 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 Chloroform 0.46 0.55 1 18 20 04/06/2021 2114 Chloromethane (Methyl chloride) 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 1,2-Dibromo-3-chloropropane (DBCP) 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 Dibromochloromethane 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 1,2-Dibromoethane (EDB) 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 Dibromomethane (Methylene bromide) 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 trans- 1,4-Dichloro-2-butene 2.0 (U) 2.0 U 1 0.00 20 04/06/2021 2114 1,2-Dichlorobenzene 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 1,4-Dichlorobenzene 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 Dichlorodifluoromethane 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 1,1-Dichloroethane 1.1 1.3 1 19 20 04/06/2021 2114 1,2-Dichloroethane 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 1,1-Dichloroethene 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 cis- 1,2-Dichloroethene 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 trans- 1,2-Dichloroethene 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 1,2-Dichloropropane 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 cis- 1,3-Dichloropropene 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 trans- 1,3-Dichloropropene 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 Ethylbenzene 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 2-Hexanone 10 (U) 10 U 1 0.00 20 04/06/2021 2114 Methyl iodide (lodomethane) 5.0 (U) 5.0 U 1 0.00 20 04/06/2021 2114 4-Methyl-2-pentanone 10 (U) 10 U 1 0.00 20 04/06/2021 2114 Methylene chloride 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 Styrene 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 1,1,1,2-Tetrachloroethane 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 1,1,2,2-Tetrachloroethane 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 Tetrachloroethene 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 Toluene 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 1,1,1-Trichloroethane 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 1,1,2-Trichloroethane 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 Trichloroethene 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 Trichlorofluoromethane 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 228 of 269 QC Data for Lot Number: WD01004 Volatile Organic Compounds by GC/MS - Duplicate Sample ID: WD01004-011DU Matrix: Aqueous Batch: 88149 Prep Method: 5030E Analytical Method: 8260D Sample Amount Result %RPD Parameter (ug/L) (ug/L) Q Dil % RPD Limit Analysis Date 1,2,3-Trichloropropane 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 Vinyl acetate 5.0 (U) 5.0 U 1 0.00 20 04/06/2021 2114 Vinyl chloride 0.50 (U) 0.50 U 1 0.00 20 04/06/2021 2114 Xylenes (total) 1.0 (U) 1.0 U 1 0.00 20 04/06/2021 2114 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 109 70-130 1,2-Dichloroethane-d4 97 70-130 Toluene-d8 110 70-130 LOQ = Limit of Quantitation U = Not detected at or above the LOD N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: WD01004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 229 of 269 Volatile Organic Compounds by GC/MS - MS Sample ID: WD01004-012MS Matrix: Aqueous Batch: 88149 Prep Method: 5030E Analytical Method: 8260D Sample Spike Amount Amount Result %Rec Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 0.0 100 120 1 116 60-140 04/06/2021 2136 Acrylonitrile 0.0 100 100 1 101 70-130 04/06/2021 2136 Benzene 0.0 50 56 1 112 70-130 04/06/2021 2136 Bromochloromethane 0.0 50 51 1 101 70-130 04/06/2021 2136 Bromodichloromethane 0.0 50 52 1 103 70-130 04/06/2021 2136 Bromoform 0.0 50 56 1 112 70-130 04/06/2021 2136 Bromomethane (Methyl bromide) 0.0 50 45 1 90 70-130 04/06/2021 2136 2-Butanone (MEK) 0.0 100 97 1 97 70-130 04/06/2021 2136 Carbon disulfide 0.0 50 58 1 117 70-130 04/06/2021 2136 Carbon tetrachloride 0.0 50 55 1 110 70-130 04/06/2021 2136 Chlorobenzene 0.0 50 57 1 113 70-130 04/06/2021 2136 Chloroethane 0.0 50 50 1 100 70-130 04/06/2021 2136 Chloroform 0.0 50 51 1 103 70-130 04/06/2021 2136 Chloromethane (Methyl chloride) 0.0 50 43 1 86 60-140 04/06/2021 2136 1,2-Dibromo-3-chloropropane (DBCP) 0.0 50 48 1 96 70-130 04/06/2021 2136 Dibromochloromethane 0.0 50 57 1 113 70-130 04/06/2021 2136 1,2-Dibromoethane (EDB) 0.0 50 57 1 115 70-130 04/06/2021 2136 Dibromomethane (Methylene bromide) 0.0 50 51 1 102 70-130 04/06/2021 2136 trans- 1,4-Dichloro-2-butene 0.0 50 46 1 92 70-142 04/06/2021 2136 1,2-Dichlorobenzene 0.0 50 57 1 114 70-130 04/06/2021 2136 1,4-Dichlorobenzene 0.68 50 56 1 110 70-130 04/06/2021 2136 Dichlorodifluoromethane 0.0 50 41 1 82 60-140 04/06/2021 2136 1,1-Dichloroethane 0.0 50 54 1 108 70-130 04/06/2021 2136 1,2-Dichloroethane 0.0 50 50 1 99 70-130 04/06/2021 2136 1,1-Dichloroethene 0.0 50 56 1 111 70-130 04/06/2021 2136 cis- 1,2-Dichloroethene 0.0 50 53 1 105 70-130 04/06/2021 2136 trans- 1,2-Dichloroethene 0.0 50 54 1 108 70-130 04/06/2021 2136 1,2-Dichloropropane 0.0 50 55 1 111 70-130 04/06/2021 2136 cis- 1,3-Dichloropropene 0.0 50 54 1 108 70-130 04/06/2021 2136 trans- 1,3-Dichloropropene 0.0 50 58 1 116 70-130 04/06/2021 2136 Ethylbenzene 0.0 50 59 1 118 70-130 04/06/2021 2136 2-Hexanone 0.0 100 110 1 113 70-130 04/06/2021 2136 Methyl iodide (lodomethane) 0.0 50 51 1 103 70-130 04/06/2021 2136 4-Methyl-2-pentanone 0.0 100 100 1 103 70-130 04/06/2021 2136 Methylene chloride 0.0 50 52 1 103 70-130 04/06/2021 2136 Styrene 0.0 50 59 1 119 70-130 04/06/2021 2136 1,1,1,2-Tetrachloroethane 0.0 50 55 1 111 70-130 04/06/2021 2136 1,1,2,2-Tetrachloroethane 0.0 50 54 1 109 70-130 04/06/2021 2136 Tetrachloroethene 0.0 50 59 1 119 70-130 04/06/2021 2136 Toluene 0.0 50 59 1 118 70-130 04/06/2021 2136 1,1,1-Trichloroethane 0.0 50 55 1 109 70-130 04/06/2021 2136 1,1,2-Trichloroethane 0.0 50 56 1 112 70-130 04/06/2021 2136 Trichloroethene 0.0 50 54 1 109 70-130 04/06/2021 2136 Trichlorofluoromethane 0.0 50 49 1 98 70-130 04/06/2021 2136 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 230 of 269 QC Data for Lot Number: WD01004 Volatile Organic Compounds by GC/MS - MS Sample ID: WD01004-012MS Matrix: Aqueous Batch: 88149 Prep Method: 5030E Analytical Method: 8260D Sample Spike Amount Amount Result %Rec Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,2,3-Trichloropropane 0.0 50 56 1 111 70-130 04/06/2021 2136 Vinyl acetate 0.0 50 48 1 97 60-140 04/06/2021 2136 Vinyl chloride 0.0 50 48 1 95 70-130 04/06/2021 2136 Xylenes (total) 0.0 100 120 1 116 70-130 04/06/2021 2136 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 114 70-130 1,2-Dichloroethane-d4 94 70-130 Toluene-d8 115 70-130 LOQ = Limit of Quantitation U = Not detected at or above the LOD N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: WD01004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 231 of 269 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ88182-001 Matrix: Aqueous Batch: 88182 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone 10 U 1 10 4.0 ug/L 04/06/2021 2327 Acrylonitrile 5.0 U 1 5.0 0.80 ug/L 04/06/2021 2327 Benzene 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 Bromochloromethane 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 Bromodichloromethane 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 Bromoform 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 Bromomethane (Methyl bromide) 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 2-Butanone (MEK) 10 U 1 10 2.0 ug/L 04/06/2021 2327 Carbon disulfide 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 Carbon tetrachloride 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 Chlorobenzene 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 Chloroethane 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 Chloroform 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 Chloromethane (Methyl chloride) 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 1,2-Dibromo-3-chloropropane (DBCP) 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 Dibromochloromethane 0.50 u 1 0.50 0.40 ug/L 04/06/2021 2327 1,2-Dibromoethane (EDB) 0.50 u 1 0.50 0.40 ug/L 04/06/2021 2327 Dibromomethane (Methylene bromide) 0.50 u 1 0.50 0.40 ug/L 04/06/2021 2327 trans- 1,4-Dichloro-2-butene 2.0 u 1 2.0 0.40 ug/L 04/06/2021 2327 1,2-Dichlorobenzene 0.50 u 1 0.50 0.40 ug/L 04/06/2021 2327 1,4-Dichlorobenzene 0.50 u 1 0.50 0.40 ug/L 04/06/2021 2327 Dichlorodifluoromethane 0.50 u 1 0.50 0.40 ug/L 04/06/2021 2327 1,1-Dichloroethane 0.50 u 1 0.50 0.40 ug/L 04/06/2021 2327 1,2-Dichloroethane 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 1,1-Dichloroethene 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 cis- 1,2-Dichloroethene 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 trans- 1,2-Dichloroethene 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 1,2-Dichloropropane 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 cis- 1,3-Dichloropropene 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 trans- 1,3-Dichloropropene 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 Ethylbenzene 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 2-Hexanone 10 U 1 10 2.0 ug/L 04/06/2021 2327 Methyl iodide (lodomethane) 5.0 U 1 5.0 0.40 ug/L 04/06/2021 2327 4-Methyl-2-pentanone 10 U 1 10 2.0 ug/L 04/06/2021 2327 Methylene chloride 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 Styrene 0.50 U 1 0.50 0.41 ug/L 04/06/2021 2327 1,1,1,2-Tetrachloroethane 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 1,1,2,2-Tetrachloroethane 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 Tetrachloroethene 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 Toluene 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 1,1,1-Trichloroethane 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 1,1,2-Trichloroethane 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 Trichloroethene 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 Trichlorofluoromethane 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 232 of 269 QC Data for Lot Number: WD01004 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ88182-001 Matrix: Aqueous Batch:88182 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date 1,2,3-Trichloropropane 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 Vinyl acetate 5.0 U 1 5.0 1.2 ug/L 04/06/2021 2327 Vinyl chloride 0.50 U 1 0.50 0.40 ug/L 04/06/2021 2327 Xylenes (total) 1.0 U 1 1.0 0.40 ug/L 04/06/2021 2327 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 110 70-130 1,2-Dichloroethane-d4 99 70-130 Toluene-d8 108 70-130 LOQ = Limit of Quantitation U = Not detected at or above the LOD N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: WD01004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 233 of 269 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ88182-002 Matrix: Aqueous Batch: 88182 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 110 1 112 60-140 04/06/2021 2158 Acrylonitrile 100 110 1 112 70-130 04/06/2021 2158 Benzene 50 52 1 105 70-130 04/06/2021 2158 Bromochloromethane 50 51 1 103 70-130 04/06/2021 2158 Bromodichloromethane 50 51 1 101 70-130 04/06/2021 2158 Bromoform 50 45 1 91 70-130 04/06/2021 2158 Bromomethane (Methyl bromide) 50 56 1 113 70-130 04/06/2021 2158 2-Butanone (MEK) 100 120 1 120 70-130 04/06/2021 2158 Carbon disulfide 50 48 1 97 70-130 04/06/2021 2158 Carbon tetrachloride 50 48 1 96 70-130 04/06/2021 2158 Chlorobenzene 50 52 1 104 70-130 04/06/2021 2158 Chloroethane 50 45 1 90 70-130 04/06/2021 2158 Chloroform 50 49 1 98 70-130 04/06/2021 2158 Chloromethane (Methyl chloride) 50 51 1 101 60-140 04/06/2021 2158 1,2-Dibromo-3-chloropropane (DBCP) 50 44 1 88 70-130 04/06/2021 2158 Dibromochloromethane 50 47 1 94 70-130 04/06/2021 2158 1,2-Dibromoethane (EDB) 50 55 1 110 70-130 04/06/2021 2158 Dibromomethane (Methylene bromide) 50 51 1 102 70-130 04/06/2021 2158 trans- 1,4-Dichloro-2-butene 50 35 1 70 70-130 04/06/2021 2158 1,2-Dichlorobenzene 50 53 1 107 70-130 04/06/2021 2158 1,4-Dichlorobenzene 50 52 1 103 70-130 04/06/2021 2158 Dichlorodifluoromethane 50 52 1 103 60-140 04/06/2021 2158 1,1-Dichloroethane 50 50 1 100 70-130 04/06/2021 2158 1,2-Dichloroethane 50 48 1 96 70-130 04/06/2021 2158 1,1-Dichloroethene 50 51 1 102 70-130 04/06/2021 2158 cis- 1,2-Dichloroethene 50 52 1 104 70-130 04/06/2021 2158 trans- 1,2-Dichloroethene 50 51 1 103 70-130 04/06/2021 2158 1,2-Dichloropropane 50 54 1 108 70-130 04/06/2021 2158 cis- 1,3-Dichloropropene 50 54 1 109 70-130 04/06/2021 2158 trans- 1,3-Dichloropropene 50 46 1 91 70-130 04/06/2021 2158 Ethylbenzene 50 54 1 108 70-130 04/06/2021 2158 2-Hexanone 100 99 1 99 70-130 04/06/2021 2158 Methyl iodide (lodomethane) 50 50 1 100 70-130 04/06/2021 2158 4-Methyl-2-pentanone 100 110 1 112 70-130 04/06/2021 2158 Methylene chloride 50 50 1 100 70-130 04/06/2021 2158 Styrene 50 58 1 116 70-130 04/06/2021 2158 1,1,1,2-Tetrachloroethane 50 55 1 110 70-130 04/06/2021 2158 1,1,2,2-Tetrachloroethane 50 56 1 112 70-130 04/06/2021 2158 Tetrachloroethene 50 51 1 102 70-130 04/06/2021 2158 Toluene 50 52 1 104 70-130 04/06/2021 2158 1,1,1-Trichloroethane 50 50 1 99 70-130 04/06/2021 2158 1,1,2-Trichloroethane 50 53 1 106 70-130 04/06/2021 2158 Trichloroethene 50 51 1 101 70-130 04/06/2021 2158 Trichlorofluoromethane 50 46 1 93 70-130 04/06/2021 2158 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 234 of 269 QC Data for Lot Number: WD01004 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ88182-002 Matrix: Aqueous Batch:88182 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,2,3-Trichloropropane 50 52 1 104 70-130 04/06/2021 2158 Vinyl acetate 50 47 1 95 60-140 04/06/2021 2158 Vinyl chloride 50 55 1 109 70-130 04/06/2021 2158 Xylenes (total) 100 110 1 111 70-130 04/06/2021 2158 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 97 70-130 1,2-Dichloroethane-d4 86 70-130 Toluene-d8 92 70-130 LOQ = Limit of Quantitation U = Not detected at or above the LOD N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: WD01004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 235 of 269 Volatile Organic Compounds by GC/MS (SIM) - MB Sample ID: WQ88444-001 Matrix: Aqueous Batch:88444 Prep Method: 5030E Analytical Method: 8260D (SIM) Parameter Result Q Dil LOQ DL Units Analysis Date 1,4-Dioxane 3.0 U 1 3.0 1.0 ug/L 04/07/2021 1301 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 112 40-170 U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 236 of 269 QC Data for Lot Number: WD01004 Volatile Organic Compounds by GC/MS (SIM) - LCS Sample ID: WQ88444-002 Matrix: Aqueous Batch:88444 Prep Method: 5030E Analytical Method: 8260D (SIM) Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,4-Dioxane 50 40 1 80 70-130 04/07/2021 1212 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 110 40-170 U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 237 of 269 QC Data for Lot Number: WD01004 Volatile Organic Compounds by GC/MS (SIM) - MB Sample ID: WQ88465-001 Matrix: Aqueous Batch:88465 Prep Method: 5030E Analytical Method: 8260D (SIM) Parameter Result Q Dil LOQ DL Units Analysis Date 1,4-Dioxane 3.0 U 1 3.0 1.0 ug/L 04/08/2021 1945 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 112 40-170 U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 238 of 269 QC Data for Lot Number: WD01004 Volatile Organic Compounds by GC/MS (SIM) - LCS Sample ID: WQ88465-002 Matrix: Aqueous Batch:88465 Prep Method: 5030E Analytical Method: 8260D (SIM) Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date 1,4-Dioxane 50 44 1 88 70-130 04/08/2021 1833 Surrogate 1,2-Dichloroethane-d4 LOQ = Limit of Quantitation DL = Detection Limit Acceptance Q % Rec Limit 113 40-170 U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 239 of 269 QC Data for Lot Number: WD01004 Volatile Organic Compounds by GC/MS - MB Sample ID: WQ88591-001 Matrix: Aqueous Batch:88591 Prep Method: 5030E Analytical Method: 8260D Parameter Result Q Dil LOQ DL Units Analysis Date Acetone 10 U 1 10 4.0 ug/L 04/09/2021 2219 Acceptance Surrogate Q % Rec Limit Bromofluorobenzene 106 70-130 1,2-Dichloroethane-d4 106 70-130 Toluene-d8 105 70-130 LOQ = Limit of Quantitation U = Not detected at or above the LOD N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: WD01004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 240 of 269 Volatile Organic Compounds by GC/MS - LCS Sample ID: WQ88591-002 Matrix: Aqueous Batch:88591 Prep Method: 5030E Analytical Method: 8260D Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Acetone 100 100 1 102 60-140 04/09/2021 2112 Surrogate Q % Rec Acceptance Limit Bromofluorobenzene 94 70-130 1,2-Dichloroethane-d4 85 70-130 Toluene-d8 91 70-130 LOQ = Limit of Quantitation U = Not detected at or above the LOD N = Recovery is out of criteria DL = Detection Limit J = Estimated result < LOQ and > DL P = The RPD between two GC columns exceeds 40 % = RSD is out of criteria + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: WD01004 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 241 of 269 Dissolved Gases - MB Sample ID: WQ88775-001 Matrix: Aqueous Batch: 88775 Analytical Method: RSK - 175 Parameter Result Q Dil LOQ DL Units Analysis Date Ethane 10 U 1 10 2.5 ug/L 04/12/2021 0838 Ethene 10 U 1 10 2.5 ug/L 04/12/2021 0838 Methane 10 U 1 10 2.5 ug/L 04/12/2021 0838 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 242 of 269 QC Data for Lot Number: WD01004 Dissolved Gases - LCS Sample ID: WQ88775-002 Matrix: Aqueous Batch: 88775 Analytical Method: RSK - 175 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Ethane 550 500 1 91 70-130 04/12/2021 0851 Ethene 520 470 1 91 70-130 04/12/2021 0851 Methane 300 260 1 88 70-130 04/12/2021 0851 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 243 of 269 QC Data for Lot Number: WD01004 Dissolved Gases - MB Sample ID: WQ88828-001 Matrix: Aqueous Batch:88828 Analytical Method: RSK - 175 Parameter Result Q Dil LOQ DL Units Analysis Date Methane 2.7 J 1 10 2.5 ug/L 04/13/2021 0859 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 244 of 269 QC Data for Lot Number: WD01004 Dissolved Gases - LCS Sample ID: WQ88828-002 Matrix: Aqueous Batch:88828 Analytical Method: RSK - 175 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Methane 300 340 1 114 70-130 04/13/2021 0832 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 245 of 269 QC Data for Lot Number: WD01004 Dissolved Gases - LCSD Sample ID: WQ88828-003 Matrix: Aqueous Batch:88828 Analytical Method: RSK - 175 Spike Amount Result %Rec % RPD Parameter (ug/L) (ug/L) Q Dil % Rec % RPD Limit Limit Analysis Date Methane 300 340 1 115 0.75 70-130 30 04/13/2021 0846 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 246 of 269 QC Data for Lot Number: WD01004 ICP-MS Metals - MB Sample ID: WQ87860-001 Matrix: Aqueous Batch: 87860 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/04/2021 0532 Parameter Result Q Dil LOQ DL Units Analysis Date Antimony 2.0 U 1 2.0 0.50 ug/L 04/05/2021 1426 Arsenic 2.0 U 1 2.0 1.3 ug/L 04/05/2021 1426 Barium 5.0 U 1 5.0 1.3 ug/L 04/05/2021 1426 Beryllium 0.40 U 1 0.40 0.15 ug/L 04/05/2021 1426 Cadmium 0.50 U 1 0.50 0.13 ug/L 04/05/2021 1426 Chromium 5.0 U 1 5.0 1.3 ug/L 04/05/2021 1426 Cobalt 5.0 U 1 5.0 1.3 ug/L 04/05/2021 1426 Copper 5.0 U 1 5.0 1.3 ug/L 04/05/2021 1426 Iron 50 U 1 50 13 ug/L 04/05/2021 1426 Lead 1.0 U 1 1.0 0.25 ug/L 04/05/2021 1426 Nickel 5.0 U 1 5.0 1.3 ug/L 04/05/2021 1426 Selenium 5.0 U 1 5.0 1.3 ug/L 04/05/2021 1426 Silver 1.0 U 1 1.0 0.25 ug/L 04/05/2021 1426 Sodium 400 U 1 400 150 ug/L 04/05/2021 1426 Thallium 0.50 U 1 0.50 0.15 ug/L 04/05/2021 1426 Vanadium 5.0 U 1 5.0 2.5 ug/L 04/05/2021 1426 Zinc 10 U 1 10 2.5 ug/L 04/05/2021 1426 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 247 of 269 QC Data for Lot Number: WD01004 ICP-MS Metals - LCS Sample ID: WQ87860-002 Matrix: Aqueous Batch: 87860 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/04/2021 0532 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 100 100 1 101 80-120 04/05/2021 1432 Arsenic 100 96 1 96 80-120 04/05/2021 1432 Barium 100 100 1 102 80-120 04/05/2021 1432 Beryllium 100 94 1 94 80-120 04/05/2021 1432 Cadmium 100 98 1 98 80-120 04/05/2021 1432 Chromium 100 99 1 99 80-120 04/05/2021 1432 Cobalt 100 100 1 101 80-120 04/05/2021 1432 Copper 100 97 1 97 80-120 04/05/2021 1432 Iron 1000 1000 1 103 80-120 04/05/2021 1432 Lead 100 110 1 108 80-120 04/05/2021 1432 Nickel 100 100 1 100 80-120 04/05/2021 1432 Selenium 100 89 1 89 80-120 04/05/2021 1432 Silver 100 100 1 102 80-120 04/05/2021 1432 Sodium 1000 1100 1 106 80-120 04/05/2021 1432 Thallium 100 110 1 105 80-120 04/05/2021 1432 Vanadium 100 98 1 98 80-120 04/05/2021 1432 Zinc 100 91 1 91 80-120 04/05/2021 1432 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 248 of 269 QC Data for Lot Number: WD01004 ICP-MS Metals - MB Sample ID: WQ87861-001 Matrix: Aqueous Batch: 87861 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/04/2021 0532 Parameter Result Q Dil LOQ DL Units Analysis Date Antimony 2.0 U 1 2.0 0.50 ug/L 04/05/2021 1315 Arsenic 2.0 U 1 2.0 1.3 ug/L 04/05/2021 1315 Barium 5.0 U 1 5.0 1.3 ug/L 04/05/2021 1315 Beryllium 0.40 U 1 0.40 0.15 ug/L 04/05/2021 1315 Cadmium 0.50 U 1 0.50 0.13 ug/L 04/05/2021 1315 Chromium 5.0 U 1 5.0 1.3 ug/L 04/05/2021 1315 Cobalt 5.0 U 1 5.0 1.3 ug/L 04/05/2021 1315 Copper 5.0 U 1 5.0 1.3 ug/L 04/05/2021 1315 Lead 1.0 U 1 1.0 0.25 ug/L 04/05/2021 1315 Nickel 5.0 U 1 5.0 1.3 ug/L 04/05/2021 1315 Selenium 5.0 U 1 5.0 1.3 ug/L 04/05/2021 1315 Silver 1.0 U 1 1.0 0.25 ug/L 04/05/2021 1315 Thallium 0.50 U 1 0.50 0.15 ug/L 04/05/2021 1315 Vanadium 5.0 U 1 5.0 2.5 ug/L 04/05/2021 1315 Zinc 10 U 1 10 2.5 ug/L 04/05/2021 1315 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 249 of 269 QC Data for Lot Number: WD01004 ICP-MS Metals - LCS Sample ID: WQ87861-002 Matrix: Aqueous Batch: 87861 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/04/2021 0532 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 100 100 1 101 80-120 04/05/2021 1321 Arsenic 100 96 1 96 80-120 04/05/2021 1321 Barium 100 100 1 102 80-120 04/05/2021 1321 Beryllium 100 96 1 96 80-120 04/05/2021 1321 Cadmium 100 97 1 97 80-120 04/05/2021 1321 Chromium 100 100 1 102 80-120 04/05/2021 1321 Cobalt 100 100 1 101 80-120 04/05/2021 1321 Copper 100 100 1 101 80-120 04/05/2021 1321 Lead 100 110 1 106 80-120 04/05/2021 1321 Nickel 100 100 1 101 80-120 04/05/2021 1321 Selenium 100 90 1 90 80-120 04/05/2021 1321 Silver 100 100 1 102 80-120 04/05/2021 1321 Thallium 100 100 1 104 80-120 04/05/2021 1321 Vanadium 100 100 1 102 80-120 04/05/2021 1321 Zinc 100 93 1 93 80-120 04/05/2021 1321 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 250 of 269 QC Data for Lot Number: WD01004 ICP-MS Metals - MS Sample ID: WD01004-019MS Matrix: Aqueous Batch: 87861 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/04/2021 0532 Sample Spike Amount Amount Result %Rec Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 0.0 100 100 1 102 75-125 04/05/2021 1333 Arsenic 0.0 100 97 1 97 75-125 04/05/2021 1333 Barium 25 100 130 1 108 75-125 04/05/2021 1333 Beryllium 0.0 100 84 1 84 75-125 04/05/2021 1333 Cadmium 0.0 100 98 1 98 75-125 04/05/2021 1333 Chromium 11 100 110 1 102 75-125 04/05/2021 1333 Cobalt 0.0 100 99 1 99 75-125 04/05/2021 1333 Copper 5.3 100 100 1 99 75-125 04/05/2021 1333 Lead 2.1 100 110 1 106 75-125 04/05/2021 1333 Nickel 1.6 100 100 1 99 75-125 04/05/2021 1333 Selenium 0.0 100 95 1 95 75-125 04/05/2021 1333 Silver 0.0 100 100 1 100 75-125 04/05/2021 1333 Thallium 0.0 100 100 1 103 75-125 04/05/2021 1333 Vanadium 12 100 110 1 99 75-125 04/05/2021 1333 Zinc 6.3 100 100 1 94 75-125 04/05/2021 1333 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 251 of 269 QC Data for Lot Number: WD01004 ICP-MS Metals - MSD Sample ID: WD01004-019MD Matrix: Aqueous Batch: 87861 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/04/2021 0532 Sample Spike Amount Amount Result %Rec % RPD Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec % RPD Limit Limit Analysis Date Antimony 0.0 100 98 1 98 3.7 75-125 20 04/05/2021 1339 Arsenic 0.0 100 96 1 96 1.8 75-125 20 04/05/2021 1339 Barium 25 100 130 1 105 3.0 75-125 20 04/05/2021 1339 Beryllium 0.0 100 81 1 81 3.6 75-125 20 04/05/2021 1339 Cadmium 0.0 100 94 1 94 3.7 75-125 20 04/05/2021 1339 Chromium 11 100 210 N,+ 1 198 60 75-125 20 04/05/2021 1339 Cobalt 0.0 100 95 1 95 4.0 75-125 20 04/05/2021 1339 Copper 5.3 100 100 1 97 2.5 75-125 20 04/05/2021 1339 Lead 2.1 100 100 1 103 2.8 75-125 20 04/05/2021 1339 Nickel 1.6 100 100 1 99 0.30 75-125 20 04/05/2021 1339 Selenium 0.0 100 94 1 94 0.94 75-125 20 04/05/2021 1339 Silver 0.0 100 96 1 96 4.0 75-125 20 04/05/2021 1339 Thallium 0.0 100 100 1 101 2.7 75-125 20 04/05/2021 1339 Vanadium 12 100 110 1 101 2.0 75-125 20 04/05/2021 1339 Zinc 6.3 100 96 1 90 4.2 75-125 20 04/05/2021 1339 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 252 of 269 QC Data for Lot Number: WD01004 ICP-MS Metals - MB Sample ID: WQ88336-001 Matrix: Aqueous Batch: 88336 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/09/2021 0402 Parameter Result Q Dil LOQ DL Units Analysis Date Antimony 2.0 U 1 2.0 0.50 ug/L 04/12/2021 1924 Arsenic 2.0 U 1 2.0 1.3 ug/L 04/12/2021 1924 Barium 5.0 U 1 5.0 1.3 ug/L 04/12/2021 1924 Beryllium 0.40 U 1 0.40 0.15 ug/L 04/12/2021 1924 Cadmium 0.50 U 1 0.50 0.13 ug/L 04/12/2021 1924 Chromium 2.0 J 1 5.0 1.3 ug/L 04112/20211924 Cobalt 5.0 U 1 5.0 1.3 ug/L 04/12/2021 1924 Copper 5.0 U 1 5.0 1.3 ug/L 04/12/2021 1924 Lead 1.0 U 1 1.0 0.25 ug/L 04/12/2021 1924 Nickel 5.0 U 1 5.0 1.3 ug/L 04/12/2021 1924 Selenium 5.0 U 1 5.0 1.3 ug/L 04/12/2021 1924 Silver 1.0 U 1 1.0 0.25 ug/L 04/12/2021 1924 Thallium 0.50 U 1 0.50 0.15 ug/L 04/12/2021 1924 Vanadium 5.0 U 1 5.0 2.5 ug/L 04/12/2021 1924 Zinc 10 U 1 10 2.5 ug/L 04/12/2021 1924 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 253 of 269 QC Data for Lot Number: WD01004 ICP-MS Metals - LCS Sample ID: WQ88336-002 Matrix: Aqueous Batch: 88336 Prep Method: 3005A Analytical Method: 6020B Prep Date: 04/09/2021 0402 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Antimony 100 96 1 96 80-120 04/12/2021 1931 Arsenic 100 96 1 96 80-120 04/12/2021 1931 Barium 100 96 1 96 80-120 04/12/2021 1931 Beryllium 100 93 1 93 80-120 04/12/2021 1931 Cadmium 100 91 1 91 80-120 04/12/2021 1931 Chromium 100 100 1 100 80-120 04/12/2021 1931 Cobalt 100 100 1 103 80-120 04/12/2021 1931 Copper 100 99 1 99 80-120 04/12/2021 1931 Lead 100 100 1 103 80-120 04/12/2021 1931 Nickel 100 100 1 103 80-120 04/12/2021 1931 Selenium 100 82 1 82 80-120 04/12/2021 1931 Silver 100 100 1 100 80-120 04/12/2021 1931 Thallium 100 100 1 101 80-120 04/12/2021 1931 Vanadium 100 100 1 100 80-120 04/12/2021 1931 Zinc 100 92 1 92 80-120 04/12/2021 1931 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 254 of 269 QC Data for Lot Number: WD01004 CVAA -MB Sample ID: WQ88214-001 Matrix: Aqueous Batch: 88214 Prep Method: Analytical Method: 7470A Prep Date: 04/07/2021 1224 Parameter Result Q Dil LOQ DL Units Analysis Date Mercury 0.00020 U 1 0.00020 0.000091 mg/L 04/07/2021 1531 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 255 of 269 QC Data for Lot Number: WD01004 CVAA - LCS Sample ID: WQ88214-002 Matrix: Aqueous Batch: 88214 Prep Method: Analytical Method: 7470A Prep Date: 04/07/2021 1224 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Mercury 0.0020 0.0018 1 92 80-120 04/07/2021 1534 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 256 of 269 QC Data for Lot Number: WD01004 CVAA - MS Sample ID: WD01004-006MS Matrix: Aqueous Batch: 88214 Prep Method: Analytical Method: 7470A Prep Date: 04/07/2021 1224 Sample Spike Amount Amount Result %Rec Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Mercury 0.000097 0.0020 0.0020 1 93 80-120 04/07/2021 1553 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 257 of 269 QC Data for Lot Number: WD01004 CVAA - MSD Sample ID: WD01004-006MD Matrix: Aqueous Batch: 88214 Prep Method: Analytical Method: 7470A Prep Date: 04/07/2021 1224 Sample Spike Amount Amount Result %Rec % RPD Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date Mercury 0.000097 0.0020 0.0019 1 91 2.8 80-120 20 04/07/2021 1601 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 258 of 269 QC Data for Lot Number: WD01004 CVAA -MB Sample ID: WQ88215-001 Matrix: Aqueous Batch: 88215 Prep Method: Analytical Method: 7470A Prep Date: 04/07/2021 1224 Parameter Result Q Dil LOQ DL Units Analysis Date Mercury 0.00020 U 1 0.00020 0.000091 mg/L 04/07/2021 1644 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 259 of 269 QC Data for Lot Number: WD01004 CVAA - LCS Sample ID: WQ88215-002 Matrix: Aqueous Batch: 88215 Prep Method: Analytical Method: 7470A Prep Date: 04/07/2021 1224 Spike Amount Result %Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Mercury 0.0020 0.0019 1 95 80-120 04/07/2021 1646 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 260 of 269 QC Data for Lot Number: WD01004 CVAA - MS Sample ID: WD01004-028MS Matrix: Aqueous Batch: 88215 Prep Method: Analytical Method: 7470A Prep Date: 04/07/2021 1224 Sample Spike Amount Amount Result %Rec Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date Mercury 0.0 0.0020 0.0019 1 93 80-120 04/07/2021 1716 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 261 of 269 QC Data for Lot Number: WD01004 CVAA - MSD Sample ID: WD01004-028MD Matrix: Aqueous Batch: 88215 Prep Method: Analytical Method: 7470A Prep Date: 04/07/2021 1224 Sample Spike Amount Amount Result %Rec % RPD Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec % RPD Limit Limit Analysis Date Mercury 0.0 0.0020 0.0019 1 96 3.1 80-120 20 04/07/2021 1719 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 262 of 269 QC Data for Lot Number: WD01004 Chain of Custody and Miscellaneous Documents Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 263 of 269 PACE ANALYTICAL SERVICES, LLC —I 'TiA � Oyu ICJ > lPdWe1T1�#���I1+13 bl'YV7 - L Pq W�A" MDT KrI-, ; 4Lo S Cr, i'4r' ti NJ Mo. F �I I 5 .� o z t7 +k Y � may} t � & r � { Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 264 of 269 PACE ANALYTICAL SERVICES, LLC E. 3 z } h' Js.1/ � w LIV1 V . ti 1� Y a� w Ste}' E qq F � ?11fYJ}{01� #h1 i f31w 7p't�"'d . o PAY* i ..It Y ir rr o- LZ M M L i F Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 265 of 269 PACE ANALYTICAL SERVICES, LLC Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 266 of 269 PACE ANALYTICAL SERVICES, LLC CO LO L z M■E111 ONO �Mwlill � s4�*i'7j1L1 OA 'i ylyOJIh _ �w y a011 idtH JG�N Ak4 r I I I i s ' .a a� n Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 267 of 269 PACE ANALYTICAL SERVICES, LLC o u ir�r y�y�J IG ILE RE . al4 R W % +Ca l r <,a LLY{ W (Ui.} 7 0 3 — t Ln 3.4 I � QLJ �I h� 5 1 r) I t) C I � E r � d LJ I I sg F Ig N yj F U I *-J - t — �. rl X4 w �y 4 L m Q f ��• . C 4 941-v {4 of 4 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 268 of 269 PACE ANALYTICAL SERVICES, LLC Sam P1e3 1Ke[e4rt Chd!CM st (SRCI Re1,i5ed!9PW2020 rIN2e.4rIL7+Y1lC.7r' MijingAttthority= FA ENU -'LNC L Page 7 of 1 Sample Receipt Checklist (SRC} Client: ('1)M1;MrT11 coolCrrimpe3t1edby lal:ile, Mf.H- )+ _ l.,ntlt..WDC10041WU0101L tv3CHnsv: reCoM; Pace Client i �-Ps f i 11 Otk:er, ,K Yes No 1_ Were cadOdY seals PMME on tha cooler`s ` gs No nMA 2, if custody seals were pre nt, w-C(e they intact and unlsrobc�[� PH siriP I u: Chlea-ine Strip lD, N.4 -- - Tested by; nr.eH Uriginul Temperature up rl recgr? i3cTjvvd (CorL-ceted) temperature upl n receipt '✓NSolid Snag-C'up [D: NA 1_R 48 a 3_L /�.] a+ L,S1.5 c 4_G /4.6 °C 'w1�llLu+I_ QTempo-- plank F �lnsr BOCLIns 1R C-un Q ' _ .. !R Gun f aLrectiarL Factor- a . °C \4-rod ofrflatlr_rLL- ❑, Wet lca I, Ice Mcks' L1 T-)i" ice 0 None _ ❑ Yo ❑ N+ NR 3, IF Lemperature of arty tooicr � x—Mit! b_0' , was Prniect Manager NoLifii PM vias Notift cd by; plw-w ? rma:l ? Nce-W,faob (circle one). d Yes lqn I INA d_ tl:e vanilliacial oauricr' a pwt;kin- sGp -ittAcl-mil to this form 7 ,1' Yva Nu 5_ V4+eri plvp*x custody Erl�dt�3ures (Ltlinyu shed'rece'vod) folln�4ed,' „r Yusl I jNoi 6, W'ere sample ]Ds listc.l un Lhe CDC.? J yes �No 7. W'cre sm1ple [Ds liste6 on all sample crrntaineLs7 -- Dye$ tiro g. +,'M'wy cotter -ion drit& time listed on the COC? U yegi F1pda} 9. Wv collectim dais & time NO kio all salrple cunluitrorS? MYuy Na 11), 1)id ull LSLn,Lainer label Intarmation (10, date, titre) agree whir the COC? Yes No 11. Were tuts to 13e potfoznexl ll&Led on AicCOO a Q Yes ❑ No 13, Did all sarLlp'eS arrive in he pni-per --oatainers fair u-eh test andfor in guud conditim, (unb:okerr, ]Ids on, 7.11 Yes Ll Na! l3. Was adecluam-,amplevolunto available? yes t110 14, Were al: sarnplas irut: iv&J with4L VN lheboldirtgtime or48 hours, whlcheveroomcs Flrst? d Yn too 15.Vruoan�'swil 'esuonrrincrsrrl:s€in xcc ircl-01W wLmpiasNotlistedonCOC'� ❑ Y+sst N❑ ❑NA lb. Farr VOA and KSK-175 ,ainrles, -WM hubbles presonI "'Pea -size" ('la'°ar 6mFr in dlamctCr] in arLy C f the V OA Y-mis e ,r y}, N NA M Were all UftO+trletals!nn1r3en1 saltnples received at a pH of a 27 d Yes Ll Nol Lj lq.h IS. U."em all cyanide mrrkoles received at a pH > 12 alld SU ICL& S&F-1-3les rr.rt_iVCLi a a pH > 9? [� Y':A O No � 10 EINA �N 19. Were ail appliarrlbll; N11VTKNAoy0ldJpheno 1 .1198-3 (< O..ng.'L) samples trot, a' residual cLlorine? 20_ %Vwc chopt�L remarkxFNL.Mk.9(:-e requested rlihdior� MWMSD dusiVrations,eto,..j „ , by {.ariscribed ttwn tho CC�C ielto the caramerlt roecdr%n in 1-1148? Yes r-1 Ycv 7�fo1 121. WL15 Ll:� yuo� Lnintber liUtA irrL tlw mim nor label? If yes, [7� ore ran Sample 1"reservatioe (Must be completed for any surrrple(s) hvD1:reorly laresarved Dr w t11 hcac]s -) Sutnple(5j wA _ _ wara received incorrectly prt!wn eed and were Odju;1le(1 ac::Dl'dkgly :n sntnP6 reaaeivi tg witIl M' ML aFcircic anC: H2-503> HNO3, HCI, NaOH using SR 9 M Time oCPt nervation KA ifmnrc tL4w oue pie eTvatiuc is needed, p-cast: F101W in lb-, CO: moots Frlrr4'. $umplc(s} NA - - urere received with hbblm >6 mm in diamdrr. Saluplcs(s)MA — -- wens.reCCj%%+l W'Ith7RC>0,5Were - ddjuSted ,.coor�di igly in samplo rcc_i Bing wiw7 sodi-nn thiomI f•21Gei (NFL S,{)..) xilh 811e by ID, A bwrqucic :abet appiied by' mr•.wa-sr[ wte. Keg: Uf21 { 4rn7[lCnts; r-XCGSS: MW-34 (D1S5 1+{Is rAL.SCONTAI iz4j: NM-6 &. MW-L L (VFA5 VIALS) Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 269 of 269 aceAnalytical Report of Analysis CDM Smith 5400 Glenwood Avenue Suite 400 Raleigh, NC 27612 Attention: Mathew Colone Project Name: North Wake Unlined Landfill Lot Number:WD01011 Date Completed:06/03/2021 06/07/2021 12:11 AM Approved and released by: Project Manager II: Cathy S. Dover =w�4 aecRFo���A4W- TNI / AM Amflvue Acm^rmm Fvu rj (' 4eOfFAi� ACC R E OI TEO TESTINGL aORlTOAY The electronic signature above is the equivalent of a handwritten signature. This report shall not be reproduced, except in its entirety, without the written approval of Pace Analytical Services, LLC. Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 Tel:803-791-9700 Fax:803-791-9111 www.pacelabs.com Page 1 of 15 PACE ANALYTICAL SERVICES, LLC SC DHEC No: 32010001 NELAC No: E87653 NC DENR No: 329 NC Field Parameters No: 5639 Case Narrative CDM Smith Lot Number: WD01011 This Report of Analysis contains the analytical result(s) for the sample(s) listed on the Sample Summary following this Case Narrative. The sample receiving date is documented in the header information associated with each sample. All results listed in this report relate only to the samples that are contained within this report. Sample receipt, sample analysis, and data review have been performed in accordance with the most current approved The NELAC Institute (TNI) standards, the Pace Analytical Services, LLC ("Pace") Laboratory Quality Manual, standard operating procedures (SOPS), and Pace policies. Any exceptions to the TNI standards, the Laboratory Quality Manual, SOPS or policies are qualified on the results page or discussed below. Dissolved Metals 6020B The dissolved metals samples listed below were taken off hold per client for analysis. • MW-6: Cobalt, vanadium • MW-34: Chromium, cobalt, vanadium • MW-36: Chromium, cobalt, vanadium If you have any questions regarding this report please contact the Pace Project Manager listed on the cover page. Pace Analytical Services, LLC (formerly Shealy Environmetal Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 whw.pacelabs.com Page 2 of 15 PACE ANALYTICAL SERVICES, LLC Sample Summary CDM Smith Lot Number: WD01011 Project Name: North Wake Unlined Landfill Project Number: Sample Number Sample ID Matrix Date Sampled Date Received 001 MW-7 Aqueous 03/31/20210745 04/01/2021 002 MW-6 Aqueous 03/31/20210930 04/01/2021 003 MW-34 Aqueous 03/31/20211000 04/01/2021 004 MW-36 Aqueous 03/31/20210905 04/01/2021 005 MW-30 Aqueous 03/31/20211140 04/01/2021 (5 samples) Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 3 of 15 ICP-MS Client:CDM Smith Laboratory ID:WD01011-002 Description: MW-6 Matrix: Aqueous Date Sampled:03/31/2021 0930 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 06/02/2021 1737 BPK 06/01/2021 1113 93889 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Dissolved Cobalt 7440-48-4 Dissolved Vanadium 7440-62-2 6020B 25 5.0 1.3 ug/L 1 6020B 5.0 U 5.0 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 4 of 15 ICP-MS Client:CDM Smith Laboratory ID:WD01011-003 Description: MW-34 Matrix: Aqueous Date Sampled:03/31/2021 1000 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 06/02/2021 1745 BPK 06/01/2021 1113 93889 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Dissolved Chromium Dissolved Cobalt Dissolved Vanadium 7440-47-3 6020B 5.0 U 5.0 1.3 ug/L 1 7440-48-4 6020B 6.2 5.0 1.3 ug/L 1 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 5 of 15 ICP-MS Client:CDM Smith Laboratory ID:WD01011-004 Description: MW-36 Matrix: Aqueous Date Sampled:03/31/2021 0905 Project Name: North Wake Unlined Landfill Date Received:04/01/2021 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 3005A 6020B 1 06/02/2021 1836 BPK 06/01/2021 1113 93889 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run Dissolved Chromium Dissolved Cobalt Dissolved Vanadium 7440-47-3 6020B 5.7 5.0 1.3 ug/L 1 7440-48-4 6020B 5.0 U 5.0 1.3 ug/L 1 7440-62-2 6020B 5.0 U 5.0 2.5 ug/L 1 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = Detection Limit Q = Surrogate failure U = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % J = Estimated result < LOQ and > DL L = LCS/LCSD failure H = Out of holding time W = Reported on wet weight basis D = Dilution > 1 S = MS/MSD failure Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 6 of 15 QC Summary Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: WD01011 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 7 of 15 ICP-MS - MB Sample ID: WQ93889-001 Matrix: Aqueous Batch: 93889 Prep Method: 3005A Analytical Method: 6020B Prep Date: 06/01/2021 1113 Parameter Result Q Dil LOQ DL Units Analysis Date Dissolved Chromium 5.0 U 1 5.0 1.3 ug/L 06/02/2021 1630 Dissolved Cobalt 5.0 U 1 5.0 1.3 ug/L 06/02/2021 1630 Dissolved Vanadium 5.0 U 1 5.0 2.5 ug/L 06/02/2021 1630 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 8 of 15 QC Data for Lot Number: WD01011 ICP-MS - LCS Sample ID: WQ93889-002 Matrix: Aqueous Batch: 93889 Prep Method: 3005A Analytical Method: 6020B Prep Date: 06/01/2021 1113 Spike Amount Result %Rec Parameter (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Dissolved Chromium 100 98 1 98 80-120 06/02/2021 1646 Dissolved Cobalt 100 100 1 103 80-120 06/02/2021 1646 Dissolved Vanadium 100 98 1 98 80-120 06/02/2021 1646 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 9 of 15 QC Data for Lot Number: WD01011 ICP-MS - MS Sample ID: WD01 01 1-003MS Matrix: Aqueous Batch: 93889 Prep Method: 3005A Analytical Method: 6020B Prep Date: 06/01/2021 1113 Sample Spike Amount Amount Result %Rec Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec Limit Analysis Date Dissolved Chromium 0.0 100 95 1 95 75-125 06/02/2021 1807 Dissolved Cobalt 6.2 100 100 1 98 75-125 06/02/2021 1807 Dissolved Vanadium 0.0 100 97 1 97 75-125 06/02/2021 1807 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 10 of 15 QC Data for Lot Number: WD01011 ICP-MS - MSD Sample ID: WD01 01 1-003MD Matrix: Aqueous Batch: 93889 Prep Method: 3005A Analytical Method: 6020B Prep Date: 06/01/2021 1113 Sample Spike Amount Amount Result %Rec % RPD Parameter (ug/L) (ug/L) (ug/L) Q Dil % Rec % RPD Limit Limit Analysis Date Dissolved Chromium 0.0 100 97 1 97 1.8 75-125 20 06/02/2021 1814 Dissolved Cobalt 6.2 100 110 1 101 2.3 75-125 20 06/02/2021 1814 Dissolved Vanadium 0.0 100 99 1 99 2.6 75-125 20 06/02/2021 1814 LOQ = Limit of Quantitation DL = Detection Limit U = Not detected at or above the LOD J = Estimated result < LOQ and > DL = RSD is out of criteria N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 11 of 15 QC Data for Lot Number: WD01011 Chain of Custody and Miscellaneous Documents Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 12 of 15 PACE ANALYTICAL SERVICES, LLC 00 f� x 12 p 4 9 Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 13 of 15 PACE ANALYTICAL SERVICES, LLC L-f? ,� r .j 0DIN h es 1- _ w R z LU V.3 L) a f 4y Cl ,� r .j 0DIN h es 1- _ w R z LU V.3 L) a f 4y Cl C3 i s^a^or a"wi.rt,Y- o��r II I 13 Ll {3 dT �} Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 14 of 15 PACE ANALYTICAL SERVICES, LLC Sam pies Roreipt theddm (SRCI (ME001EC-15) Re+�isrr{ j 9f 2020 LeArsafyfiCt7f ISSLinZAutho-ity:PaceENV-'JVCDL Page 1of t11 .Ple Receipt C:hooklist (SRQ Eli nt LL}4T$tylrCH C4ale]' hss cc;,3d by,'dale- MU-1. a O1.*112021 1 `A',-)DI(%'XAVD91011 to-rraceipl: Pace M...i[ [TPq � FcJEx Other: 2M&:vs Vr yzs A't, 1_ VJ custnd sr fs present ant�ec o[ r? Yes No TEA 2, Ifd mi) s,sLfp %vcrc resent, u re lllcy inlRct a=Ld unbrakEn? pH Strip ID; Q1�a'Q4 C~hlorrneSnip ITS; K` A1G:1 Tested by: � DrigiaaJ kn)IJ � MMUpon receipt r' Derived (Correehd) tcml,erafata up013 rC(Xipt "AS lid Snap -Cup TT); NA 4.8 :-C 3-1 14.$ �13.1 0c 1.9 11.9 0r- 4.0 14.6 aC f4JeElfud; ZTempolatuLtsBlank7JA aLrst I1rrtLlca [Rdun ]D: ' IR Gn Cnrrrct;an FarLur: 0 ¢C Method ofGoolarf; d V4'ct Ice U Jce Ptic3:s ED f)tv Ice ' None Yes Quo �ty, 3. Iftelaperalurc ofar,,Y Cooler t!);L! ed 6RT, was P-JiGrtMenagr h'r Firm? No PM was Notified h-_ pl,oue e email ' face-tc-Nce (eirc:lc one)_ t�JTcs 4_ Is the com�,3r1;iai eonriw's pwkingslFlo atlar.;jeil _othis fonn? v Yes Nu 5_ %Vwo proper rni3mcly Pit rdure.; (Iry IFLiquisdw ,'received) fal[a4vorn V, YiAt .. NO 6. `]-rm siajii lr Ills Jlstpd on thF, V, Yes ❑ No ?. V.t= sample )1�3 IIS�G DLL all sarrlplc C(J1IL.1inC.M? Yea No kt- WaS c011eVb0'M daLilrp [Isted sin Ihr. f'10C? zjY No 9. WM colrecfiandate r_j]ne listed an al[sample uMtainM? Yc5 lYp Ifl_ Did all vontainer label ir_fi nnution (TT), d4re, 1411g) agree with the COC? 71 Yes No I !. er-a wis to, l,c ptTfarmed fisted or, Lhc C oC? a*r—, l J2L T7rrl 0111 San tpics arrive in [heprupercon talncrs fovea&-as.armUo~ in 2xd acu,diri= (unEmken, lids Ott, etc,) I:i- Wa* tldcquate i;a�t !e nl-1 me availnhiPO Jd, lkfere t ll sairrl�l� received tit-itltirl flthe 1,4ldllls�* E ❑-dg hours, whick_eVy-r-Ca15. 1� eE u y samples C=311lors m issin eh¢es , i rc'r� CHI ram p:es Nut li steel! on cod? 0 Yes,1 NO E]N 4 [6. Fc�r Yi1R zrLd IL K-] 75 x�1rLp[es u�v bubbies pl%MrL( >"fez -sirs„ (�44"{rr 63r.tr- in r[inme[er) m atly of the VOA Vials? "esKa NA 17. Wore allDR0lmeiaisiLkttrieJ 1 samples received tlt 11 p] 1 of <? O V A 19- Wea•e all c)�ani�c son, Ales rGUivcd atlR p¢I -, 12 and git1J U-z sslttplesl received At aO � 1�'A ] 9. LVere all al,['icx�bie 1dHii l'[{i�lCyatLLdelphcnall�2S,I E.3 (� 1,5mz) sarrlplrb tree aY ❑ yes Na ©NA 2Q. Were cricnt rcrrrarkslr�l,exts (i.e. rcquL:sted dilLt[Jon$, MSdhfRl] desj�r1L11ians, etc... correctly trar.scribed f o71 the COC inlD dhe ccgttrr_ellt ycx;fion in 1.TMS? 'ea v ]- Was the uot-- number listed un the container [ohol? lfyee, Quart 4�1A ullPIP Pmu.natiom (MIA31be WMtILefed foranp #Arnple(s) incorrectly preserved or with head�J,�ree.j - SarsLple{s) NA _worcreceived incorredlyprt--imed and WMe Wiusrcdace wd; g;y in Sample receiving turkh Nr~ LnL orcirere ime: H2SO4, AN{33, MC], Na0 iI 11sill Timo ofprc541vadmi lCmora than one eavntive i,, needed, rase t]ude in he C Xn neri(, bUI93 �- -- F� [I; t S{vlip[e(r;j n vca e�ceiv;d with aubhles >6 mJn i_, dialne*er. were received wiki TRC c 1 adjn.sLtap:grding[y in S2mplc receiving witll sCxliulr'Itiosalfate b. in {]. +lei isAty}anCf �rcrc (Nn. sla3) with SjL,�Ajy lE): NA Rbatwdclabels ippl6,6bw: MEWJSH T];tc _ - Cl turn ilts: tXCES5: NNW-30 (0r3S METALS CD" I.1 iPJ_I)! P-iW4 & M yJ-1; (WAS MO.) Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 15 of 15 aceAnalytical LELAP CERTIFICATE NUMBER: 01955 DOD-ELAP ACCREDITATION NUMBER: 74960 ANALYTICAL RESULTS PERFORMED BY Pace Analytical Gulf Coast 7979 Innovation Park Dr. Baton Rouge, LA 70820 (225) 769-4900 Report Date 04/26/2021 Report Y 211041544 �1��i �1��i �1��i �1��i �1��i �1��i �1��i �1��i �1��i III Project N. Wake Unlined LF WD01004 Deliver To Cathy Dover Pace Analytical Services South Carolina 106 Vantage Point Drive West Columbia, SC 29172 (803)791-9700 PJLA Testing DOD ELAP Additional Recipients NONE zSO V 7025 L Pace Gulf Coast Report#: 221041544 Page 1 of 15 Report#: 221041544 ace k k+ytUh Project ID: N. Wake Unlined LF WD01004 Report Date: 04/26/2021 Laboratory Endorsement Sample analysis was performed in accordance with approved methodologies provided by the Environmental Protection Agency or other recognized agencies. The samples and their corresponding extracts will be maintained for a period of 30 days unless otherwise arranged. Following this retention period the samples will be disposed in accordance with Pace Gulf Coast's Standard Operating Procedures. Common Abbreviations that may be Utilized in this Report ND Indicates the result was Not Detected at the specified reporting limit NO Indicates the sample did not ignite when preliminary test performed for EPA Method 1030 DO Indicates the result was Diluted Out MI Indicates the result was subject to Matrix Interference TNTC Indicates the result was Too Numerous To Count SUBC Indicates the analysis was Sub -Contracted FLD Indicates the analysis was performed in the Field DL Detection Limit LOD Limit of Detection LOQ Limit of Quantitation RE Re -analysis CF HPLC or GC Confirmation 00:01 Reported as a time equivalent to 12:00 AM Reporting Flags that may be Utilized in this Report J or I Indicates the result is between the MDL and LOQ J DOD flag on analyte in the parent sample for MS/MSD outside acceptance criteria U Indicates the compound was analyzed for but not detected B or V Indicates the analyte was detected in the associated Method Blank Q Indicates a non -compliant QC Result (See Q Flag Application Report) " Indicates a non -compliant or not applicable QC recovery or RPD — see narrative E Organics - The result is estimated because it exceeded the instrument calibration range E Metals - % diference for the serial dilution is > 10% L Reporting Limits adjusted to meet risk -based limit. P RPD between primary and confirmation result is greater than 40 DL Diluted analysis — when appended to Client Sample ID Sample receipt at Pace Gulf Coast is documented through the attached chain of custody. In accordance with NELAC, this report shall be reproduced only in full and with the written permission of Pace Gulf Coast. The results contained within this report relate only to the samples reported. The documented results are presented within this report. This report pertains only to the samples listed in the Report Sample Summary and should be retained as a permanent record thereof. The results contained within this report are intended for the use of the client. Any unauthorized use of the information contained in this report is prohibited. I certify that this data package is in compliance with The NELAC Institute (TNI) Standard 2009 and terms and conditions of the contract and Statement of Work both technically and for completeness, for other than the conditions in the case narrative. Release of the data contained in this hardcopy data package and in the computer readable data submitted has been authorized by the Quality Assurance Manager or his/her designee, as verified by the following signature. Estimated uncertainty of measurement is available upon request. This report is in compliance with the DOD QSM as specified in the contract if applicable. Authorized Signature Pace Gulf Coast Report 221041544 Pace Gulf Coast Report#: 221041544 Page 2 of 15 PaceAr�alYl�+l Report#: 221041544 Project ID: N. Wake Unlined LF WD01004 Report Date: 04/26/2021 Certifications Certification Certification Number DOD ELAP 74960 Alabama 01955 Arkansas 88-0655 Colorado 01955 Delaware 01955 Florida E87854 Georgia 01955 Hawaii 01955 Idaho 01955 Illinois 200048 Indiana 01955 Kansas E-10354 Kentucky 95 Louisiana 01955 Maryland 01955 Massachusetts 01955 Michigan 01955 Mississippi 01955 Missouri 01955 Montana N/A Nebraska 01955 New Mexico 01955 North Carolina 618 North Dakota R-195 Oklahoma 9403 South Carolina 73006001 South Dakota 01955 Tennessee 01955 Texas T104704178 Vermont 01955 Virginia 460215 Washington C929 USDA Soil Permit P330-16-00234 Pace Gulf Coast Report#: 221041544 Page 3 of 15 Report#: 221041544 ace k k+ytUh Project ID: N. Wake Unlined LF WD01004 Report Date: 04/26/2021 Case Narrative Client: Pace Analytical Services South Carolina Report: 221041544 Pace Analytical Gulf Coast received and analyzed the sample(s) listed on the Report Sample Summary page of this report. Receipt of the sample(s) is documented by the attached chain of custody. This applies only to the sample(s) listed in this report. No sample integrity or quality control exceptions were identified unless noted below. PROJECT MANAGER COMMENTS The samples were received at the laboratory on the day that holding times expired for Hydrogen analysis. The analyses were completed as quickly as possible. (Ruth Welsh 04/16/2021 09:24) Pace Gulf Coast Report#: 221041544 Page 4 of 15 aceAr�alYl�+l Report#: 221041544 Project ID: N. Wake Unlined LF WD01004 Report Date: 04/26/2021 Sample Summary LAB ID Client ID Matrix Collect Date Receive Date 22104154401 MW-5R Water 03/31/202110:25 04/14/2021 09:50 22104154402 MW-6 Water 03/31/202109:30 04/14/2021 09:50 22104154403 MW-8 Water 03/31/202113:45 04/14/2021 09:50 22104154404 MW-9 Water 03/31/202108:45 04/14/2021 09:50 22104154405 MW-10 Water 03/31/202108:20 04/14/2021 09:50 22104154406 MW-11 Water 03/31/202112:30 04/14/2021 09:50 22104154407 MW-34 Water 03/31/202110:00 04/14/2021 09:50 22104154408 MW-34d Water 03/31/202110:10 04/14/2021 09:50 22104154409 MW-36 Water 03/31/202109:05 04/14/2021 09:50 22104154410 MW-5R (1-12) Bubble Strip 03/31/2021 10:25 04/14/2021 09:50 22104154411 MW-6 (1-12) Bubble Strip 03/31/2021 09:30 04/14/2021 09:50 22104154412 MW-8 (1-12) Bubble Strip 03/31/2021 13:45 04/14/2021 09:50 Pace Gulf Coast Report#: 221041544 Page 5 of 15 ace k k+ytUh Report#: 221041544 Project ID: N. Wake Unlined LF WD01004 Report Date: 04/26/2021 Detect Summary LAB ID Client ID Method Parameter Result Units 22104154401 MW-5R AM23G Acetic Acid 63 mg/L 22104154401 MW-5R AM23G Formic Acid 59 mg/L 22104154401 MW-5R AM23G Propionic Acid 4.3J mg/L 22104154402 MW-6 AM23G Acetic Acid 0.24J mg/L 22104154402 MW-6 AM23G Formic Acid 5.6 mg/L 22104154403 MW-8 AM23G Acetic Acid 1.7J mg/L 22104154403 MW-8 AM23G Formic Acid 25 mg/L 22104154404 MW-9 AM23G Acetic Acid 0.27J mg/L 22104154404 MW-9 AM23G Butyric Acid 0.14J mg/L 22104154404 MW-9 AM23G Formic Acid 5.6 mg/L 22104154405 MW-10 AM23G Acetic Acid 0.22J mg/L 22104154405 MW-10 AM23G Formic Acid 5.2 mg/L 22104154406 MW-11 AM23G Acetic Acid 0.50J mg/L 22104154406 MW-11 AM23G Formic Acid 11 mg/L 22104154407 MW-34 AM23G Acetic Acid 1.1J mg/L 22104154407 MW-34 AM23G Formic Acid 34 mg/L 22104154408 MW-34d AM23G Acetic Acid 0.27J mg/L 22104154408 MW-34d AM23G Formic Acid 6.3 mg/L 22104154409 MW-36 AM23G Acetic Acid 1.2J mg/L 22104154409 MW-36 AM23G Formic Acid 28 mg/L 22104154410 MW-5R (H2) AM20GAX Hydrogen 2.9 nM 22104154412 MW-8 (H2) AM20GAX Hydrogen 2.1 nM Pace Gulf Coast Report#: 221041544 Page 6 of 15 Report#: 221041544 Project ID: N. Wake Unlined LF WD01004 Report Date: 04/26/2021 Sample Results Collect Date 03/31/2021 10:25 LAB ID 22104154401 MW-5R Receive Date 04/14/2021 09:50 Matrix Water AM23G Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 10 04/20/202101:42 MOS 708803 CAS# Parameter Result DL LOQ Units 64-19-7 Acetic Acid 63 1.2 5.0 mg/L 107-92-6 Butyric Acid 0.58U 0.58 5.0 mg/L 64-18-6 Formic Acid 59 0.55 5.0 mg/L 142-62-1 Hexanoic Acid 0.581-1 0.58 5.0 mg/L 646-07-1 i-Hexanoic Acid 0.56U 0.56 5.0 mg/L 503-74-2 i-Pentanoic Acid 0.61 U 0.61 5.0 mg/L 50-21-5 Lactic Acid 0.531-1 0.53 5.0 mg/L 109-52-4 Pentanoic Acid 0.56U 0.56 5.0 mg/L 79-09-4 Propionic Acid 4.3J 0.53 5.0 mg/L 127-17-3 Pyruvic Acid 0.60U 0.60 5.0 mg/L Collect Date 03/31/2021 09:30 LAB ID 22104154402 MW-6 Receive Date 04/14/2021 09:50 Matrix Water AM23G Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 04/20/202102:36 MOS 708803 CAS# Parameter Result DL LOQ Units 64-19-7 Acetic Acid 0.24J 0.12 0.50 mg/L 107-92-6 Butyric Acid 0.0581.1 0.058 0.50 mg/L 64-18-6 Formic Acid 5.6 0.055 0.50 mg/L 142-62-1 Hexanoic Acid 0.0581-1 0.058 0.50 mg/L 646-07-1 i-Hexanoic Acid 0.0561.1 0.056 0.50 mg/L 503-74-2 i-Pentanoic Acid 0.061 U 0.061 0.50 mg/L 50-21-5 Lactic Acid 0.0531-1 0.053 0.50 mg/L 109-52-4 Pentanoic Acid 0.0561.1 0.056 0.50 mg/L 79-09-4 Propionic Acid 0.0531.1 0.053 0.50 mg/L 127-17-3 Pyruvic Acid 0.0601-1 0.060 0.50 mg/L Collect Date 03/31/2021 13:45 LAB ID 22104154403 MW-8 Receive Date 04/14/2021 09:50 Matrix Water AM23G Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 5 04/20/202103:29 MOS 708803 CAS# Parameter Result DL LOQ Units 64-19-7 Acetic Acid 1.7J 0.62 2.5 mg/L 107-92-6 Butyric Acid 0.291.1 0.29 2.5 mg/L 64-18-6 Formic Acid 25 0.27 2.5 mg/L 142-62-1 Hexanoic Acid 0.29U 0.29 2.5 mg/L 646-07-1 i-Hexanoic Acid 0.281.1 0.28 2.5 mg/L 503-74-2 i-Pentanoic Acid 0.30U 0.30 2.5 mg/L 50-21-5 Lactic Acid 0.261J 0.26 2.5 mg/L 109-52-4 Pentanoic Acid 0.281.1 0.28 2.5 mg/L 79-09-4 Propionic Acid 0.261.1 0.26 2.5 mg/L Pace Gulf Coast Report#: 221041544 Page 7 of 15 Report#: 221041544 Project ID: N. Wake Unlined LF WD01004 Report Date: 04/26/2021 Sample Results Collect Date 03/31/2021 13:45 LAB ID 22104154403 MW-8 Receive Date 04/14/2021 09:50 Matrix Water AM23G (Continued) Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 5 04/20/202103:29 MOS 708803 CAS# Parameter Result DL LOQ Units 127-17-3 Pyruvic Acid 0.30U 0.30 2.5 mg/L Collect Date 03/31/2021 08:45 LAB ID 22104154404 M W-9 Receive Date 04/14/2021 09:50 Matrix Water AM23G Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 04/20/202104:23 MOS 708803 CAS# Parameter Result DL LOQ Units 64-19-7 Acetic Acid 0.27J 0.12 0.50 mg/L 107-92-6 Butyric Acid 0.14J 0.058 0.50 mg/L 64-18-6 Formic Acid 5.6 0.055 0.50 mg/L 142-62-1 Hexanoic Acid 0.058U 0.058 0.50 mg/L 646-07-1 i-Hexanoic Acid 0.056U 0.056 0.50 mg/L 503-74-2 i-Pentanoic Acid 0.061 U 0.061 0.50 mg/L 50-21-5 Lactic Acid 0.053U 0.053 0.50 mg/L 109-52-4 Pentanoic Acid 0.056U 0.056 0.50 mg/L 79-09-4 Propionic Acid 0.0531-1 0.053 0.50 mg/L 127-17-3 Pyruvic Acid 0.060U 0.060 0.50 mg/L Collect Date 03/31/2021 08:20 LAB ID 22104154405 MW-10 Receive Date 04/14/2021 09:50 Matrix Water AM23G Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 04/20/202107:03 MOS 708803 CAS# Parameter 64-19-7 Acetic Acid 107-92-6 Butyric Acid 64-18-6 Formic Acid 142-62-1 Hexanoic Acid 646-07-1 i-Hexanoic Acid 503-74-2 i-Pentanoic Acid 50-21-5 Lactic Acid 109-52-4 Pentanoic Acid 79-09-4 Propionic Acid 127-17-3 Pyruvic Acid Result DL LOQ Units 0.22J 0.12 0.50 mg/L 0.0581.1 0.058 0.50 mg/L 5.2 0.055 0.50 mg/L 0.0581.1 0.058 0.50 mg/L 0.0561.1 0.056 0.50 mg/L 0.061 U 0.061 0.50 mg/L 0.0531.1 0.053 0.50 mg/L 0.0561.1 0.056 0.50 mg/L 0.053U 0.053 0.50 mg/L 0.0601.1 0.060 0.50 mg/L Pace Gulf Coast Report#: 221041544 Page 8 of 15 Report#: 221041544 Project ID: N. Wake Unlined LF WD01004 Report Date: 04/26/2021 Sample Results Collect Date 03/31/2021 12:30 LAB ID 22104154406 MW-11 Receive Date 04/14/2021 09:50 Matrix Water AM23G Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 2 04/20/202120:24 MOS 708803 CAS# Parameter Result DL LOQ Units 64-19-7 Acetic Acid 0.50J 0.25 1.0 mg/L 107-92-6 Butyric Acid 0.12U 0.12 1.0 mg/L 64-18-6 Formic Acid 11 0.11 1.0 mg/L 142-62-1 Hexanoic Acid 0.121-1 0.12 1.0 mg/L 646-07-1 i-Hexanoic Acid 0.11 U 0.11 1.0 mg/L 503-74-2 i-Pentanoic Acid 0.121-1 0.12 1.0 mg/L 50-21-5 Lactic Acid 0.11 U 0.11 1.0 mg/L 109-52-4 Pentanoic Acid 0.11 U 0.11 1.0 mg/L 79-09-4 Propionic Acid 0.11 U 0.11 1.0 mg/L 127-17-3 Pyruvic Acid 0.121J 0.12 1.0 mg/L Collect Date 03/31/2021 10:00 LAB ID 22104154407 MW-34 Receive Date 04/14/2021 09:50 Matrix Water AM23G Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 5 04/20/202108:50 MOS 708803 CAS# Parameter Result DL LOQ Units 64-19-7 Acetic Acid 1.11 0.62 2.5 mg/L 107-92-6 Butyric Acid 0.291.1 0.29 2.5 mg/L 64-18-6 Formic Acid 34 0.27 2.5 mg/L 142-62-1 Hexanoic Acid 0.291.1 0.29 2.5 mg/L 646-07-1 i-Hexanoic Acid 0.281.1 0.28 2.5 mg/L 503-74-2 i-Pentanoic Acid 0.301-1 0.30 2.5 mg/L 50-21-5 Lactic Acid 0.261.1 0.26 2.5 mg/L 109-52-4 Pentanoic Acid 0.281.1 0.28 2.5 mg/L 79-09-4 Propionic Acid 0.261-1 0.26 2.5 mg/L 127-17-3 Pyruvic Acid 0.301.1 0.30 2.5 mg/L Collect Date 03/31/2021 10:10 LAB ID 22104154408 MW-34d Receive Date 04/14/2021 09:50 Matrix Water AM23G Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 04/20/202109:43 MOS 708803 CAS# Parameter Result DL LOQ Units 64-19-7 Acetic Acid 0.27J 0.12 0.50 mg/L 107-92-6 Butyric Acid 0.0581.1 0.058 0.50 mg/L 64-18-6 Formic Acid 6.3 0.055 0.50 mg/L 142-62-1 Hexanoic Acid 0.0581.1 0.058 0.50 mg/L 646-07-1 i-Hexanoic Acid 0.0561.1 0.056 0.50 mg/L 503-74-2 i-Pentanoic Acid 0.061 U 0.061 0.50 mg/L 50-21-5 Lactic Acid 0.0531.1 0.053 0.50 mg/L 109-52-4 Pentanoic Acid 0.0561.1 0.056 0.50 mg/L 79-09-4 Propionic Acid 0.053U 0.053 0.50 mg/L Pace Gulf Coast Report#: 221041544 Page 9 of 15 Report#: 221041544 Project ID: N. Wake Unlined LF WD01004 Report Date: 04/26/2021 Sample Results Collect Date 03/31/2021 10:10 LAB ID 22104154408 MW-34d Receive Date 04/14/2021 09:50 Matrix Water 3G (Continued) Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 04/20/202109:43 MOS 708803 CAS# Parameter Result DL LOQ Units 127-17-3 Pyruvic Acid 0.060U 0.060 0.50 mg/L Collect Date 03/31/2021 09:05 LAB ID 22104154409 MW-36 Receive Date 04/14/2021 09:50 Matrix Water 3G Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 5 04/20/202118:37 MOS 708803 CAS# Parameter Result DL LOQ Units 64-19-7 Acetic Acid 1.2J 0.62 2.5 mg/L 107-92-6 Butyric Acid 0.29U 0.29 2.5 mg/L 64-18-6 Formic Acid 28 0.27 2.5 mg/L 142-62-1 Hexanoic Acid 0.29U 0.29 2.5 mg/L 646-07-1 i-Hexanoic Acid 0.28U 0.28 2.5 mg/L 503-74-2 i-Pentanoic Acid 0.30U 0.30 2.5 mg/L 50-21-5 Lactic Acid 0.26U 0.26 2.5 mg/L 109-52-4 Pentanoic Acid 0.28U 0.28 2.5 mg/L 79-09-4 Propionic Acid 0.26U 0.26 2.5 mg/L 127-17-3 Pyruvic Acid 0.30U 0.30 2.5 mg/L Collect Date 03/31/2021 10:25 LAB ID 22104154410 MW-5R (H2) Receive Date 04/14/2021 09:50 Matrix Bubble Strip OGAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 04/18/202114:43 JCK2 708745 CAS# Parameter Result DL LOQ Units 1333-74-0 Hydrogen 2.9 0.49 1.9 nM Collect Date 03/31/2021 09:30 LAB ID 22104154411 MW-6 (H2) Receive Date 04/14/2021 09:50 Matrix Bubble Strip OGAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 2 04/18/202114:55 JCK2 708745 CAS# Parameter 1333-74-0 Hydrogen Result DL LOQ Units 0.98U 0.98 3.8 nM Pace Gulf Coast Report#: 221041544 Page 10 of 15 Report#: 221041544 Project ID: N. Wake Unlined LF WD01004 Report Date: 04/26/2021 Sample Results Collect Date 03/31/2021 13:45 LAB ID 22104154412 MW-8 (H2) Receive Date 04/14/2021 09:50 Matrix Bubble Strip AM20GAX Prep Date Prep Batch Prep Method Dilution Analysis Date By Analytical Batch NA NA NA 1 04/18/202115:07 JCK2 708745 CAS# Parameter Result DL LOQ Units 1333-74-0 Hydrogen 2.1 0.49 1.9 nM Pace Gulf Coast Report#: 221041544 Page 11 of 15 Report#: 221041544 Project ID: N. Wake Unlined LF WD01004 Report Date: 04/26/2021 General Chemistry QC Summary Analytical Batch Client ID MB708803 LCS708803 LCSD708803 708803 LAB ID 2173032 2173033 2173034 Sample Type MB LCS LCSD Prep Date Analysis Date 04/19/21 19:29 04/19/21 18:35 04/20/21 05:16 Matrix Water Water Water AM23G Units mg/L Spike Result %R Control Spike Result %R RPD RPD Result DL Added Limits%R Added Limit Acetic Acid 64-19-7 0.12U 0.12 2.0 2.0 99 70 - 130 2.0 1.9 95 4 20 Butyric Acid 107-92-6 0.058U 0.058 2.0 1.9 95 70 - 130 2.0 1.9 97 2 20 Formic Acid 64-18-6 0.055U 0.055 2.0 1.8 92 70 - 130 2.0 1.8 92 0 20 Hexanoic Acid 142-62-1 0.058U 0.058 2.0 2.0 98 70 - 130 2.0 1.9 97 1 20 i-Hexanoic Acid 646-07-1 0.056U 0.056 2.0 1.8 89 70 - 130 2.0 1.8 88 1 20 i-Pentanoic Acid 503-74-2 0.061 U 0.061 2.0 1.9 96 70 - 130 2.0 1.9 97 1 20 Lactic Acid 50-21-5 0.053U 0.053 2.0 1.8 89 70 - 130 2.0 1.8 90 1 20 Pentanoic Acid 109-52-4 0.056U 0.056 2.0 1.9 95 70 - 130 2.0 1.9 95 0 20 Propionic Acid 79-09-4 0.053U 0.053 2.0 1.8 91 70 - 130 2.0 1.8 93 2 20 Pyruvic Acid 127-17-3 0.060U 0.060 2.0 1.8 90 70 - 130 2.0 1.8 91 1 20 Pace Gulf Coast Report#: 221041544 Page 12 of 15 Report#: 221041544 Project ID: N. Wake Unlined LF WD01004 Report Date: 04/26/2021 General Chromatography QC Summary Analytical Batch Client ID MB708745 LCS708745 LCSD708745 708745 LAB ID 2172876 2172877 2172878 Sample Type MB LCS LCSD Prep Date Analysis Date 04/18/21 13:57 04/18/21 14:11 04/18/21 14:30 Matrix AM20GAX Units nM Spike Result I %R I I Control Spike Result I %R I RPD I RPD Result DLI Added Limits%R 1 Added Limit Hydrogen 1333-74-0 0.49U 1 0.491 121 13 11081 70 - 130 1 121 1411161 7 1 20 Pace Gulf Coast Report#: 221041544 Page 13 of 15 aceAnalytical rtu Pace Analytical Services, LLC. Chain of Custody 106 Vantage Point Drive Record West Columbia, South Carolina 29172 Telephone No. (803) 791-9700 Fax No. (803) 791• _ www�acelabs. com CIlent ID; Shealy Envir - Pace Analysical SeMoos South Carolina PM: RVVe 1!11111 111 1 i ii i iiiiiiiii I III Client Report to ContactTelephone No.1 E-mail Quote No. Pace Analytical Services -SC Cathy Dover 919 16.11So mth Aover ( }6 y @pacelabs.00m Address Sampler's Signature Analysis (Attach list if more space is needed) Page 106 Van [age point Drive X 1 or 1 _ City State Zlp Code Lot # Bar Code West Columbia SC 29172 Printed Name y (lab use only) Project Name N.Wake Unlined LF 0 Project Number P C• No- Matrix No of Containers by g �? r5 c� Preservative Type Sample ID 1 Description Collection Collection y a p a o a ❑ „ x Y .0 a d (Cantaine+s ror each sample may be combined on one line) Date(s) Time w Z = z k' w rn Remarks 1 Cooler I.D. (military) a 7 ; C3 MW-5R 3/31/2021 1025 X X X X I VFA-BAK Pres. 0 WD01004.038 MW 8 3/31/2021 0930 X X X X VFA-BAK Pres. a I WD01004.039 MW-8 3/31/2021 1345 X X X X VFA-BAK Pres. 01WD01004-040 MW-9 3/31/2021 0845 X X VFA-BAK Pres. WD01004-041 MW-10 3/31/2021 0820 X X VFA-BAK Pres. rj WD01004-042 MW-11 3/31/2021 1230 X X VFA-BAK Pres. WD01004-043 MW-34 3/31/2021 1000 X X VFA-BAK Pres. WD01004-044 MW-34d 3/31/2021 1010 X X VFA-BAK Pres. WD01004-045 MW-36 3/31/2021 0905 X X VFA-BAK Pres, 01 WD01004-046 'rum Around Time Required (Prior lab approval required for expedited TAT) Sample Disposal Possible Hazard Identification (Lis[ any known hazards in the remarks] QC Requirements ❑ Standard 0 Rush (Please Specify) 5-7 business days ❑ ReSurn to Client Disposal by Lab ❑Non.Hazardom ❑ Flammable ❑ skin ura.m ❑SGS pmvided ❑ nNnown 1. Relinquished by Date Time 1. Received by Date Time 2. Relinquished bf Daat Ti 2. Received by Date TI a Y -,I) rr l V 3, Relinquished by Dath Time 3. Received by Oat Time 4. Relinquished by Date Time 4. Laboratory Received by Date Time Note: All samples are retained for four weeks from LAB USE ONLY Receipt Temp. Temp. Blank receipt unless other arrangements are made I Received on Ice (Check) ❑ Y ❑ N ❑ Ice Pack 6 :Z o C ❑ Y 1 ❑N yo C-P 1-N 1 LkL -3 . U-2,N Pace Gulf Coast Report#: 221041544 Page 14 of 15 /.5navivfica' SAMPLE RECEIVING CHECKLIST IIIIII�INIIIII SAMPLE DELIVERY GROUP 221041544 CHECKLIST YES NO Client PM RWe Transport Method Samples received with proper thermal preservation? *❑ ❑ Shealy Envir - Pace Analytical FEDDC Services South Carolina Radioactivity is <1600 cpm? If no, record cpm value in notes section. COC relinquished and complete (including samplelDs, collect times, and sampler)? *❑ *❑ ❑ ❑ Profile Number Received By 284727 N/bCune, DDdie K All containers received in good condition and within hold time? All sample labels and containers received match the chain of custody? *❑ 0 ❑ ❑ Line Item(s) Receive Date(s) 1 - LL VFA 04/14/21 2- hydrogen Preservative added to any containers? ❑ *❑ If received, was headspace for VOC water containers < 6mm? *❑ ❑ Samples collected in containers provided by Pace Gulf Coast? 0 ❑ COOLERS DISCREPANCIES LAB PRESERVATIONS Airbill Thermometer ID: E34 Temp °C None None 166334653621 0.7 NOTES Revision 1.6 Page 1 of 1 Pace Gulf Coast Report#: 221041544 Page 15 of 15