Date of Site Inspection: April 27, 2017 Date of Last Inspection: September 1, 2016
FACILITY NAME AND ADDRESS:
Town of Ahoskie Yard Waste Site
Old Sewer Plant
South End of Rhue Street
Ahoskie, NC 27910
GPS COORDINATES: N: 36.27327' W: - 76.99193
FACILITY CONTACT NAME AND PHONE NUMBER:
Name: Linda L. Blackburn, Mayor Pro Tem, Justin Freeman, Council Member
Telephone: 252-332-5146 Town Hall
Email address: blackburn.lindal&amail.com Justinfreemanl8gamail.com
Kirk Rogers, Public Works Director, 252-332-5165, kirkrogers@ahoskie.org
Stephen Lassiter, Assistant Public Works Director, 252-332-5146, stephenlassiter@ahoskie.org
FACILITY CONTACT ADDRESS:
Hal Mason, Ahoskie Interim Town Manager
201 W. Main Street
P.O. Box 767
Ahoskie, NC 27910
Kirk Rogers, 500 S. Catherine Street, Ahoskie, NC 27910
Steve Lassiter, 500 S. Catherine Street, Ahoskie, NC 27910
PARTICIPANTS:
Mary Whaley, NCDEQ, Solid Waste Section
STATUS OF PERMIT:
Site is a notified site. Every year the site must be notified by June ls`
PURPOSE OF SITE VISIT:
Partial Inspection
STATUS OF PAST NOTED VIOLATIONS:
NA
OBSERVED VIOLATIONS:
1. 15A NCAC 13B .1406 An operator shall be on duty at the site at all times while the facility is open for public
use to ensure compliance with operational requirements and access to such facilities shall be controlled. The
gate was wide open, not locked, as it is supposed to be without an attendant on duty. The gate being left
open has been stated on most of the previous reports.
Page 1 of 4
FACILITY COMPLIANCE INSPECTION REPORT
�a Waste Management Division of Waste Management
EN VIRONf4ENTAL OUAL ITV
r Solid Waste Section
2. 15A NCAC 1313.1404 (a) If there are Edge of Waste markers, marking the 50 foot buffer from a proper
line. thev are not easilv visible and within line of siLyht. T posts were observed with painted toes. but it
could not be distinguished as being a property line marker or edge of waste marker. There was a T- post
(with painted top) within 50 feet of the canal- what is its purpose, as all waste is to be kept a minimum of
50 feet from surface water. This has been commented on in the last several reports.
3. 15A NCAC 1313.1406 (3) Surface water shall be diverted from the operational, compost curing, and storage
areas. The site must be graded to prevent ponding of water and there is to be no waste in water. There
were many areas of standing water and waste in water at the site.
The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance
with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an
administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit,
or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to
enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any
such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules.
ADDITIONAL COMMENTS
1. There appeared to be an area where driller's mud has been off loaded. Driller's mud cannot be put at the
Yard Waste site. This material must be removed from the site and brought to an approved disposal site.
2. There was some unacceptable waste in with the debris. Remove all unacceptable waste. The amount of
unacceptable debris is much less than usual, so good job, but, make sure there is no unacceptable debris. This
has been commented on, on most every previous inspection report
3. This yard waste site appears not to have been used recently. There are tall grasses and weeds growing up over
the site.
4. A 25-foot minimum distance is required around the site as well as between compost areas and swales or berms
to allow for adequate access of firefighting equipment.
5. A 50-foot minimum buffer for debris is required from all property lines.
Please contact me if you have any questions or concerns regarding this inspection report.
A"17 Phone: 919-693-5023
Environmental Senior Specialist
Regional Representative
Sent on: May 5, 2017 Email Hand delivery US Mail Certified No. fI
Copies: Andrew Hammonds, Eastern District Supervisor - Solid Waste Section
Jessica Montie, Compliance Officer - Solid Waste Section
Page 2 of 4
FACILITY COMPLIANCE INSPECTION REPORT
�a Waste Management Division of Waste Management
EN VIRONf4ENTAL OUAL ITV
Solid Waste Section
Gate wide open and no one at the site
r
Site does not appear to be used much and is growing up with weeds
Page 3 of 4
to Waste Management
ENVIRONMENTAL QUALITY
FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
ry,7 -
Driller's mud must be removed and disposed of at a permitted facility able to accept the material
Standing water- site to be graded to prevent ponding water