Loading...
HomeMy WebLinkAboutSWC-11-10 092111 Audit11 NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section UNIT TYPE: Lined LCID YW Transfer Compost X SLAS COUNTY: BUNCOMBE MSWLF PERMIT NO.: SWC-11-10 Closed xIIW White Incin T&P FIRM MSWLF goods FILE TYPE: COMPLIANCE CDLF TireT&P Tire Industrial DEMO SDTF Collection Monofill Landfill Date of Site Inspection: 09/21/2011 FACILITY NAME AND ADDRESS: The Asheville School 360 Asheville School Rd. Asheville NC 28806 Date of Last Inspection: 07/05/2011 GPS COORDINATES: N: 35.567000 E:-82.62305 FACILITY CONTACT NAME AND PHONE NUMBER: Name: Andrew Kegg Telephone: (919) 593-2233 Email address: kegga@ashevilleschool.org Ed Maggart (828) 713-0541; maggarte@ashevilleschool.org PARTICIPANTS: Andrea Keller — NCDENR Solid Waste Section Steve Butera — Asheville School (former facility contact) Andrew Kegg — Asheville School (current facility contact) STATUS OF PERMIT: Active - Small Type III Composting Permit Permit renewal date: July 22, 2010 Permit expiration date: July 22, 2015 PURPOSE OF SITE VISIT: Comprehensive site inspection STATUS OF PAST NOTED VIOLATIONS: None OBSERVED VIOLATIONS 1. 15A NCAC 13B .1406 Operational Requirements for Solid Waste Compost Facilities (14)(A) The finished product shall meet the classification and distribution requirements outlined in Rule .1407 of this Section. 2090 US Highway 70, Swannanoa, North Carolina 28778 Phone: 828-296-4500 \ FAX: 828-299-7043 \ Internet: http://Portal.ncdenr.o[g/web/wm/sw Nne orthCarohna naturally An Equal Opportunity \ Affirmative Action Employer FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 2 of 3 Review of facility records indicated that analytical testing for pathogen reduction requirements had not been conducted. The facility produced minimal product over the last 2-year period and product was utilized primarily on facility grounds (not for public purchase). In addition, the reported metal concentrations did not match the required testing regimen. (See Item #2 below) The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. ADDITIONAL COMMENTS 1. Met on site to conduct comprehensive site inspection. New contact (AKegg) for facility, along with previous contact (SButera). 2. Based on the facility's request for clarification of testing and reporting requirements for Grade A compost, historical governing documents for the facility and associated Rule requirements (.1406, .1407, and .1408) were reviewed and are outlined below: Test Requirements Test Description/MethodologyDescription/Methodology Allowable Limits A dried, weighed sample of compost product is passed through Foreign Matter Test a'A inch screen. The material remaining on the screen is (also known as the Manmade inspected and the foreign matter that can be clearly identified is separated and weighed. The weight of the foreign matter <6 % Inerts %dry wet inerts, per divided by the weight of the total sample is determined and 1407 Table 2) multiplied by 100 to calculate the percent dry weight of the foreign matter content. Pathogen Reduction Fecal Coliform <1000 MPN/g (PFRP test) (*more than one option for PFRP testing, Appendix B) Cd < 39 mg/kc Metal Concentration Cadmium (Cd), Copper (Cu), Lead (Pb), Nickel Cu < 1500 mg/kg (.1407 Table 1 and .1408 (Ni), and Zinc (Zn) Pb < 300 mg/kg Table 3) Ni < 420 mg/kc Zn < 2800 mg/kg http://portal.ncdenr.ory,,/web/wm/sw/rules/rulelist 3. Please note that the above test requirements must be met on a semi-annual basis (every six months). If there is no product to be tested during a 6-month cycle, please document why testing had not occurred and understand that the next batch of compost product should be testied prior to use/distribution. 4. The leachate collection system appeared functional at the time of the inspection. The facility was currently producing minimal leachate, and it was stated (SButera) that all leachate is reintroduced into an "active" bin. Temperature requirements were being met and documented in accordance with the Rules. 5. The facility appeared controlled and well -maintained. No issues noted other than the analytical testing requirements. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 3 of 3 Please contact me if you have any questions or concerns regarding this inspection report. Phone: 828-296-4700 Andrea Keller Environmental Senior Specialist Regional Representative Sent on: October 21. 20ll Email: keQQa@ashevilleschool.org ; Hand US Certified No. l� maggarte@ashevilleschool.org delivery Mail ec: Michael Scott, Section Chief — Solid Waste Section Mark Poindexter, Field Operations Branch Head — SWS Jason Watkins, Western District Supervisor — SWS Shawn McKee, Compliance Officer — SWS