HomeMy WebLinkAboutSDTF5501_INSP_20191014FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management
Solid Waste Section
Page 1 of 2
UNIT TYPE:
Lined MSWLF LCID YW Transfer Compost SLAS COUNTY: Lincoln
Closed MSWLF HHW White goods Incin T&P FIRM PERMIT NO.: SDTF-55-01
CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF X FILE TYPE: COMPLIANCE
Date of Site Inspection: 10/14/2019 Date of Last Inspection: 5/7/2019 FACILITY NAME AND ADDRESS:
Dennis Hoyle Services 7337 Reeps Grove Church Rd.
Vale, NC 28168 GPS COORDINATES: N: 35.53474° W: 31.42380° FACILITY CONTACT NAME AND PHONE NUMBER:
Name: Dennis Hoyle Telephone: (704) 276-2080 (o) (980) 429-0438
Email address: dhseptics@gmail.com FACILITY CONTACT ADDRESS:
P.O. Box 84 Vale, NC 28168
PARTICIPANTS: Troy Harrison, NC Solid Waste Section
Dennis Hoyle, Dennis Hoyle Services STATUS OF PERMIT:
Active Issued: 8/19/2019
Expired: 8/19/2024 Permit renewal submitted
PURPOSE OF SITE VISIT: Permitting Inspection
STATUS OF PAST NOTED VIOLATIONS: N/A
OBSERVED VIOLATIONS:
The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules.
FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section
Page 2 of 2
ADDITIONAL COMMENTS
1. The Septage Detention and Treatment facility (SDTF) consisted of one 4,000-gallon, one 8,000-gallon, and
one 12,000-gallon tank for a total capacity of 34,000 gallons. These tanks are above ground and shall be used for the storage of domestic septage (including portable toilet waste) and grease trap septage.
2. There was also a 20,000-gallon tank on site that is NOT listed on the permit. This tank shall not be used for septage storage until placed in position, inspected by the Solid Waste Section and found to be in compliance. 3. Set-back/buffer requirements appear to have been met. 4. The “No Trespassing” sign was observed 5. All weather roads are maintained for access to the site. 6. The 4,000-gallon, 8,000-gallon and 12,000 tanks appeared to be structurally sound and well maintained. The
10,000-gallon tank was observed during previous inspections to have multiple open holes and extensive rust damage with evidence of a previous leaks on the side. The tank has been emptied and no longer listed on the permit and cannot be used. 7. No leaks or spills were observed around the tanks.
8. No odors were observed around the tanks. Please contact me if you have any questions or concerns regarding this inspection report.
_______________________________________ Phone: 828-296-4701 Troy Harrison Environmental Senior Specialist Regional Representative
Sent on: 10/14/2019 X Email Hand delivery US Mail Certified No.
Copies: Connie Wylie, NC Solid Waste Section files