HomeMy WebLinkAbout2613-TRANSFER-2010_INSP_20210412FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management
Solid Waste Section
Page 1 of 5
UNIT TYPE:
Lined MSWLF LCID YW Transfer X Compost SLAS COUNTY: Cumberland
Closed MSWLF HHW White goods Incin T&P FIRM PERMIT NO.: 2613-Transfer-2010
CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF FILE TYPE: COMPLIANCE
Date of Site Inspection: April 12, 2021 Date of Last Inspection: February 23, 2021
FACILITY NAME AND ADDRESS: AAA Hauling of NC, Inc., 1171 S. Eastern Blvd, Fayetteville, North Carolina GPS COORDINATES: Lat: 35.02625 Long: -78.88159
FACILITY CONTACT NAME AND PHONE NUMBER: Kenny Hardin, 910-321-6037 or 910-868-5800 aaahaulingofnc@yahoo.com David Williams dfwblw@msn.com
FACILITY CONTACT ADDRESS: AAA Hauling of NC, Inc., 1171 S. Eastern Blvd, Fayetteville, North Carolina
PARTICIPANTS: Drew Hammonds, NC DEQ – Solid Waste Section
David Powell, NC DEQ – Solid Waste Section Kenny Hardin – AAA Hauling David Williams – AAA Hauling
Sherri Lawton – AAA Hauling STATUS OF PERMIT: PTO Issued May 18, 2018 – Expires Dec. 2, 2070 Active
PURPOSE OF SITE VISIT: Routine Comprehensive Inspection Follow up
STATUS OF PAST NOTED VIOLATIONS: 15A NCAC 13B .0405 (a)(3)(D) - RESOLVED
OBSERVED VIOLATIONS: NA
The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules.
FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management
Solid Waste Section
Page 2 of 5
ADDITIONAL COMMENTS
1. Andrew Hammonds and David Powell with the Section, inspected Triple “A” Hauling Transfer station to follow up on the issues mentioned in the previous inspection.
2. Previous inspection, dated 2/23/2021, stated the fire, that was previously onsite at the transfer station, had been put into a roll off onsite. Mr. Harding informed Section staff this was not true, but that the burned material in
the roll off was from an offsite job and not the onsite fire. 3. Tipping floor was cleaner and more orderly this visit. Good Job. The tipping floor and transfer loading area
must be maintained in a clean, sanitary condition and must be cleaned at least daily in accordance with the approved operations plan. Waste must only be deposited on a “tipping floor” or directly into a transfer container. Waste “must not be stored on the “tipping floor” after operating hours. All waste must be placed in containers by the end of the day or removed for disposal. Including the piles of comingled waste reportedly to be screened.
Permit Attachment 3 Part IV. 18. - b. Waste must only be deposited on a “tipping floor” or directly into a transfer container. Waste must not be stored on the “tipping floor” after operating hours. 4. Site still needs to address storm water management, and therefore leachate management. Site needs proper grading to shed storm water properly and prevent comingling of storm water with waste onsite creating
additional leachate. Refer to approved Sedimentation Erosion Control Plan to manage storm water. Road should be of all-weather construction and pad should be built up more. Discussions onsite were that the facility needs to update Operations Plan and resubmit to Section with a new map. Concrete pad needs to be bigger for accounting for the needed tipping floor working area.
FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management
Solid Waste Section
Page 3 of 5
5. Entrance to rear of facility, where tipping floor is, has had most of the tires removed except what’s been kept for reselling. Good job, but be sure to follow through with removal of the older ones in edge of woods behind palletized resell tires.
6. Onsite roll offs were in better condition. Containers not taken to landfill by end of the day need to be covered overnight and taken by the next day. Be diligent in repairing and taking damaged ones out of service to prevent
leachate from leaving site or soaking in surrounding area which may cause surface water or ground water issues. Another reason for updating Operations plan is to address leachate issues and how the cleanup response will be done. Speedy dry mix cannot address some of the issues that Section staff have witnessed onsite.
Permit Attachment 3 Part IV. 18. - c. Waste may be stored on-site, in leak proof transfer trailers, with watertight covers, a maximum of 24 hours except that a minimal amount of waste may be stored for a maximum of 72 hours when the facility is closed during a weekend or holiday. Storage of the waste must not cause any nuisance, such as odor or attraction of vectors.
FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management
Solid Waste Section
Page 4 of 5
7. Current approved Operations Plan allows for the grinding of clean wood. Clean wood will be ground on “the pad” and then the ground wood will be containerized and shipped to customer. Conveyor and grinder was not operating during inspection. Clean wood goes to Wilkes road facility.
8. This facility is not approved to grind construction and demolition debris. Changes to the operations plan and or permit conditions must be submitted to the permitting branch staff for review and approval before commencing. 9. C and D soil screenings go to Ann St. landfill to be used as ADC. Analytical testing and/or waste characterization of the soil screenings should be completed periodically to ensure unacceptable wastes are not comingled in the screenings and end up in the wrong disposal site for that waste type.
10. Windblown litter was not an issue during inspection. Good job. 11. Certified Transfer Station Operations Specialist Certification are currently David Williams and John Killian.
Mr. Hardin says he will be taking the course soon to ensure they have enough certified operators. 12. Mr. Hardin informed Section staff that currently, approximately 90% of his loads go to the landfill. It may be necessary to direct haul waste to the permitted landfill(s) if it isn’t possible to manage it in accordance with the permit and approved operations plans. 13. Sign at front entrance of facility was no longer blocked by vegetation. Vegetation will grow back quickly so be diligent in trimming to ensure visibility with signage.
FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management
Solid Waste Section
Page 5 of 5
14. On June 4, 2021, Mr. Powell emailed David Williams and Kenny Hardin the new Transfer Station rules, copy of the 2/23/2021 inspection, and the current PTO and Operations plan for the station. SWANA contact, Scott, email was also given so that Mr. Williams could contact SWANA for literature on Transfer Station Operations. Please contact me if you have any questions or concerns regarding this inspection report. ________________________________________ Phone: (910) 433 - 3350_______ David Powell
Environmental Senior Specialist
Regional Representative
Sent on: 4/26/2021 X Email Hand delivery US Mail Certified No. [ _]
Copies: Drew Hammonds, Eastern District Supervisor - Solid Waste Section Ben Jackson, Permitting Engineer Sherri Stanley, Permitting Branch Head