HomeMy WebLinkAboutSDTF7822_INSP_20210414FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
Page 1 of 6
UNIT TYPE:
Lined
MSWLF LCID YW Transfer Compost SLAS COUNTY: Robeson
Closed
MSWLF HHW White
goods Incin T&P FIRM PERMIT NO.: SDTF 78-22
CDLF Tire T&P /
Collection Tire
Monofill Industrial
Landfill DEMO SDTF X FILE TYPE: COMPLIANCE
Date of Site Inspection: 4/14/2021 Date of Last Inspection: 9/08/2020
FACILITY NAME AND ADDRESS:
Enviro-Choice
P.O. Box 390
Lumberton, NC 28359
GPS COORDINATES: N: 34.70635 E: -79.03776
FACILITY CONTACT NAME AND PHONE NUMBER:
Name: Michael Cody Hunt
Telephone: (910) 738-5311
Email address: envirochoicenc@gmail.com
Fax: (910) 738-5563
FACILITY CONTACT ADDRESS:
3330 Saddletree Road
Lumberton, NC 28360
PARTICIPANTS:
Connie Wylie, Matthew Markus
STATUS OF PERMIT:
Active – permit expires August 24, 2023
PURPOSE OF SITE VISIT:
Routine
STATUS OF PAST NOTED VIOLATIONS:
N/A
OBSERVED VIOLATIONS:
1. .0838(j) Septage shall be transferred to and from a detention system in a manner that prevents leaks or spills onto
the ground surface or exterior surface of the detention system, including septage in pipes used for transferring
waste to and from vehicles.
A significant amount of liquid/effluent was noted on the ground surface behind Secondary Storage Tank #1. I was
informed that an incident had occurred with a hose which caused the spill. Also the honey wagon used to
discharge effluent onto the disposal fields was parked in this area and the valve on the side outlet was dripping
effluent onto the ground.
SEE THE NEXT PAGE
FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
Page 2 of 2
The valves on the honey wagon shall be fixed as needed & maintained in proper working order for this vehicle to
be used for any septage activity. Measures shall be taken to prevent septage spills but if they occur they shall be
cleaned up immediately. A bucket shall be immediately placed under any leaking valve until the issue is fixed.
FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
Page 3 of 3
It was noted that the drip bucket (under the valve connection for flex hoses from discharging pump trucks) was
full of septage liquid and had overflowed onto the ground surface.
This drip bucket shall be emptied and all septage cleaned up from the ground surface.
Also the bottom outlet from Primary Storage Tank #2 had a wet stain area on the ground surface under the valve
and the drip bucket under this outlet had a significant amount of septage liquid.
The septage shall be completely cleaned up from the ground surface in this area. All drip buckets shall be
routinely emptied to prevent overflows. Any septage spills on the ground surface shall be immediately cleaned up.
FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
Page 4 of 4
The concrete sides of the pit area had septage (liquid & solids) on the top edge, down the sides and on the ground
surface in various areas around the pit. Misc trash items (plastic buckets etc) were again noted in the pit area -
this has been noted in previous audits. Only septage is permitted to go in this concrete pit.
.
The septage shall be completely cleaned from the top, sides and ground surface along the concrete perimeter of
the pit. Measures shall be taken to prevent septage spills around the perimeter of the pit. If septage does collect on
the top edge it shall be pushed back into the pit and any spills on the ground surface shall be immediately cleaned
up. Misc trash shall not be dumped in this concrete pit area.
FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
Page 5 of 5
The roll off box beside the pit had a septage spill on the ground surface at one corner. Septage was also noted
along the top and down the sides and on the ground surface in various areas around the roll off box.
Septage shall be properly contained within the roll off box and not be spilled on the top edge, sides or on the
surrounding ground surface. And spills on the top, sides or ground surface shall be immediately cleaned up.
FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
Page 6 of 6
ADDITIONAL COMMENTS
1. The tanks appeared structurally sound.
2. The required signs were posted and the access road was adequate.
3. The approved setbacks are being met.
4. Maintain the required 5’ cleared radius (free of excess vegetation or debris) around the tank & pit.
5. On the day of this site visit there were conversations with Mr. Hunt & Mr. Markus in regards to the violations.
Corrective actions were immediately being implemented.
Please contact me if you have any questions or concerns regarding this inspection report.
_ Phone: (910) 433-3352
Connie S. Wylie
Regional Representative
Sent on: Email Hand delivery X US Mail Certified No. [ _]
The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance
with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an
administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit,
or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to
enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any
such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules.