Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
MO-28288_47548_CA_UST-61_20201230_24-Hour Release and UST Leak Reporting Form
UST-61 I 24-Hour Release and UST Leak Reporting Form. For Releases This form should be completed and submitted to the UST Section's regional office following a known or suspected release from an underground storage tank (UST) system. This form is required to be submitted within 24 hours of discovery of a known or in NC suspected release (DWM USE ONLY) Suspected Contamination? (Y/N) Y Facility ID Number N/A Incident # Risk (H,I,L,U) Confirmed GW Contamination? (Y/N) N Date Leak Discovered December 1, 2020 Received On Received By Confirmed Soil Contamination ?(Y/N) Y Comm/Non-Commercial? Non-com Reported by (circle one): Phone, Fax or Report Samples Taken?(Y/N) Y Reg/Non-regulated? Non -Reg Region Free Product? (Y/N) N If Yes, State Greatest Thickness INCIDENT DESCRIPTION Incident Name: EmpnasisAds. Inc Address: 1619 North Graham Street County: Mecklenburg Regional Office (circle one): Asheville, Mooresville, Fayetteville, City/Town: Charlotte Zip Code: 28206 Raleigh, Washington, Wilmington, Winston-Salem Latitude (decimal degrees): 35.24386 Longitude (decimal degrees) :-80.83300 Obtained by: ❑GPS Briefly describe suspected or confirmed release: (including but not limited to: nature of release, date of release, amount of release, amount of free product resent and recoveryefforts, initial responses conducted, impacts to rece tors ❑Topographic map ❑GIS Address matching DOther ❑unknown Describe location: In conjunction with a pending real estate transaction, a Phase I Assessment indicated the site may have been a historic service station prior to 1980 with evidence that the may have been removed prior to the UST regulations being promulgated. A soil boring in the former tank basin indicated petroleum impacted soil remains on -site. HOW RELEASE WAS DISCOVERED (Release code) (Check one) ❑Release Detection Equipment or Methods ❑Visual/Odor ❑Groundwater Contamination ❑During UST Closure/Removal ❑Water in Tank ❑Surface Water Contamination ®Property Transfer [—]Water Supply Well Contamination ❑Other (specify) SOURCE OF CONTAMINATION Source of Release Cause of Release Type of Release Product Type Released (Check primary source) (Check primary cause) (Check one) (Check primary product type released) ❑ Tank ❑ Spill © Petroleum 0 Gasoline/ Diesel/ ❑ DieselNeg. Oil ❑ Piping ❑ Overfill ❑ Non -Petroleum Kerosene Blend ❑Dispenser ❑ Heating Oil ❑ Vegetable Oil 100% p Corrosion ❑Both ❑ Submersible Turbine Pump ❑ Physical/Mechanical ❑ Other Petroleum ❑ El — E20 Damage Location Products ❑E21 —E84 ❑ Delivery Problem (Check one) ❑ Metals ❑ Install Problem ❑ E85 — E99 ❑ Spill Bucket ❑ Other Inorganics ❑ Other ®Facility ❑ Other ❑Ethanol 100% Unknown ❑Residence ❑ Other Organics ❑ E01 — E09 ® Unknown ❑Other Definitions presented on reverse Definitions presented on reverse Ownership 1. Municipal 2. Military 3. Unknown 4. Private 5. Federal 6. County 7. State Operation Type 1. Public Service 2. Agricultural 3. Residential 4. Education/Relig. 5. Industrial 6. Commercial Mining UST Form 61 (02/19) Page 1 of 2 IMPACT ON DRINKING WATER SUPPLIES Water Supply Wells Affected? 1. Yes 2. No 3. Unknown Number of Water Supply Wells Affected Water Supply Wells Contaminated: (Include Users Names, Addresses and Phone Numbers. Attach additional sheet if necessary) 1. 2. 3. UST SYSTEM OWNER UST Owner/Company Unknown Point of Contact Address City State Zip Code Telephone Number UST SYSTEM OPERATOR UST Operator/Company Address Unknown City State Zip Code Telephone Number LANDOWNER AT LOCATION OF UST INCIDENT Landowner Address Emphisis Ads, Inc. P.O. Box 5524 City State Zip Code Telephone Number Charlotte INC 28299 Draw Sketch of Area (showing two major road intersections) or Attach Map See Attached. Person Reporting IncidentR. Harmon Company Harmon Environmental, PA Telephone Number704-292-4527 Title C. �. Address 615 Brun TM R..d, Ma ., NC 28112 Date 12-3 2020 UST Form 61 (02119) Page 2 of 2 Definitions of Sources Tank: means the tank that stores the product and is part of the underground storage tank system Piping: means the piping and connectors running from the tank or submersible turbine pump to the dispenser or other end -use equipment (Vent, vapor recovery, or fill lines arc excluded.) Dispenser: includes the dispenser and the equipment used to connect the dispenser to the piping (e.g., a release from a suction pump or from components located above the shear valve) Submersible Turbine Pump (STP) Area includes the submersible turbine pump head (typically located in the tank sump), the line leak detector, and the piping that connects the submersible turbine pump to the tank Delivery Problem: identifies releases that occurred during product delivery to the tank. (Typical causes associated with this source are spills and overfills.) Other: serves as the option to use when the release source is known but does not fit into one of the preceding categories (e.g., for releases from vent lines, vapor recovery lines, and fill lines) Unknown: identifies releases for which the source has not been determined Definitions of Causes Spill: use this cause when a spill occurs (e.g., when the delivery hose is disconnected from the tank fill pipe or when the nozzle is removed from the dispenser) Overfill: use when an overfill occurs (e.g., overfills may occur from the fill pipe at the tank or when the nozzle fails to shut off at the dispenser) Physical or Mechanical Damage: use for all types of physical or mechanical damage, except corrosion (e.g., puncture of tank or piping, loose fittings, broken components, and components that have changed dimension) Corrosion: use when a metal tank, piping, or other component has a release due to corrosion (e.g., for steel, corrosion takes the form of rust) Installation Problem: use when the problem is determined to have occurred specifically because the UST system was not installed properly Other: use this option when the cause is known but does not fit into one of the preceding categories (e.g., putting regulated substances into monitoring wells) Unknown: use when the cause has not been determined Polaris 3G Map — Mecklenburg County, North Carolina Date Printed: 12/22/2020 3:14:54 PM 00. A-�-66 .1 . , .9 '9 OF � Vi -:0q 74W' '9' 60.4QP IM0.03 Miles 15 N! ..t*11-Sr4�1 (This map or report is prepared for the inventory of real property within Mecklenburg County and is compiled from recorded deeds, plats, tax maps, surveys, planimetric maps, and other public records and data. Users of this map or report are hereby notified that the aforementioned public primary information sources should be consulted for verification. Mecklenburg County and its mapping contractors assume no legal responsibility for the information contained herein. I �ff PaceAnalytical www.pacelabs.com 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 ANALYTICAL RESULTS Project: 861-01 Pace Project No.: 92507531 Sample: B-2 (4-8) Lab ID: 92507531001 Collected. 11/17/20 09:40 Received: 11/20/20 11:15 Matrix: Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 8015 GCS THC-Diesel Analytical Method: EPA 8015C Modified Preparation Method: EPA 3546 Pace Analytical Services - Charlotte Diesel Range Organics(C10-C28) 167 mg/kg 6.0 1 11/25/20 12:16 11/30/20 21:27 Surrogates n-Pentacosane (S) 80 % 32-130 1 11/25/20 12:16 11/30/20 21:27 629-99-2 Gasoline Range Organics Analytical Method: EPA 8015C Modified Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gas Range Organics (C6-C10) 217 mg/kg 6.3 1 11/23/20 09:59 11/23/20 15:35 Surrogates 4-Bromofluorobenzene (S) 290 % 66-131 1 11/23/20 09:59 11/23/20 15:35 460-00-4 Percent Moisture Analytical Method: ASTM D2974-87 Pace Analytical Services - Charlotte Percent Moisture 14.7 % 0.10 1 11/20/20 17:43 Date: 12/01/2020 03:12 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. S5 Page 8 of 14 Beverly, Trudy From: Beverly, Trudy Sent: Monday, January 4, 2021 7:24 AM To: Rick Harmon Cc: Byron Burns Subject: RE: [External] UST-61 Form for 1619 North Graham Street Charlotte, NC Received. Trudy Trudy Beverly, L.G. D_�IE Hydrogeologist, Division of Waste Management North Carolina Department of Environmental Quality UST Section, Mooresville Regional Office IFeparlren[ol Gmn-nnmental4ua, 704.235.2182 (Office) Trudy. B everlykncdenr. gov Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Office Mailing Address: 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Branch's Underground Storage Tanks Website Address: https://deg.nc.gov/about/divisions/waste-management/ust Branch's Above Ground Storage Tanks Website Address: hit2s://deq.nc.gov/about/divisions/waste-management/ust/ast-program INTERACTIVE MAPS WITH DWM SITES AND PERMITTED FACILITIES: httns://dea.nc. gov/about/divisions/waste-management/waste-management-rules-data/waste-management-gis-mans File Review Procedures: hops://deq.ne. gov/about/divisions/waste-management/ust/file-review-procedures#mooresville-regional-office ONLINE ACCESS TO UST SECTION DOCUMENTS (Laserfiche): fts://deq.nc.gov/about/divisions/waste-manaizement/laserfiche Document Submittal & UST File Names for Laserfiche Policies: htti)s:Hfiles.ne.izov/nedeafWaste%2OMana2ement/DWM/UST[WhatsNew/Final-Electronic-Document-Submittal-Policv.l)df https:Hfiles.nc.gov/ncdeq/Waste%20Management/DWM/UST/Corrective%2OAction/UST%20filc%20names%20for%2OLaserfiche.docx From: Rick Harmon [mailto:harmonenv@yahoo.com] Sent: Wednesday, December 30, 2020 8:4S AM To: Beverly, Trudy <trudy.beverly@ncdenr.gov> Cc: Byron Burns <byron@red iron partners.com> Subject: [External] UST-61 Form for 1619 North Graham Street Charlotte, NC CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Ms. Beverly: As discussed in a -mails earlier this year, in conjunction with a pending property transfer, a Phase I Environmental Assessment was conducted on this site by another consultant. This Phase I indicated this site may have been a historic service station until the late 1970's. Harmon Environmental, PA evaluated the historic records and determined that a portion of the former tank basin is now located under the North Graham Street right-of-way. A Geoprobe boring advanced in the on -site portion of the former tank basin on November 17, 2020 indicated the presence of petroleum compounds in the soil. Attached please find a UST-61 Form addressing this release. Our client, Mr. Byron Burns of Red Iron Properties, LLC desires to close this site with a Notice of Residual Petroleum (NORP). Per our earlier email conversations, during the week of January 4, 2020, Harmon Environmental, PA will initiate a 1,000 foot radius receptor survey of this site. Please call or email if you have any questions. Richard Harmon, P.G. Harmon Environmental, PA 615 Bruce Thomas Road Monroe, NC 28112 704-292-4527 harmonenvironmental.com