HomeMy WebLinkAboutMO-28176_47436_CA_CLO_20200924_Tank Abandoment ReportCedar Rock
ENVIRONMENTAL
September 24, 2020
Mr. Ryan Kozusko
7527 Glencannon Drive
Charlotte, NC 28227
CEDAR ROCK ENVIRONMENTAL, P.C.
107 Pioneer Trail
Graham, NC 27253
(336) 376-0394
RE: Underground Storage Tank (UST) Closure Assessment Report
7527 Glencannon Drive, Charlotte, North Carolina
Cedar Rock Project Number 302222590
Dear Mr. Kozusko:
Cedar Rock Environmental, P.C. (Cedar Rock) is pleased to submit this report describing activities
and results for the in -place abandonment of the onsite UST located at 7527 Glencannon Drive in
Charlotte, North Carolina. The UST abandonment was performed on September 21, 2020.
Included in this report are project documents consisting of a disposal manifest and photographic
documentation. This report should be kept with other documents pertaining to the residential
property.
Soil contamination was detected beneath the UST during a site inspection performed on September
7, 2020. The release was reported to the Department of Environmental Quality (DEQ) using a
UST-61 form on September 10, 2020. Although the State no longer requires further assessment
of the contamination, the State does require the filing of a Notice of Residual Petroleum (NRP)
prior to conveying the property to another party. The NRP includes land use restrictions
prohibiting any disturbance of site soils within a specified radius of the estimated extent of soil
contamination and prohibits the use or installation of any water supply wells on the property.
Cedar Rock filed the NRP on September 16, 2020. The DEQ will issue a Conditional Notice of
No Further Action (NFA) letter within the next few days. Upon receipt of proof that the local
officials and adjacent property owners have been notified of the release by receiving a copy of the
Conditional NFA letter, and that the NRP has been filed, the DEQ will reissue the NFA letter with
no conditions to officially close out the petroleum release incident.
Enclosed is an invoice for this work effort. If you have any questions, please do not hesitate to
contact me at 336-376-0394. Thank you for your consideration of Cedar Rock to provide you with
this service.
Sincerely,
Robert A. Payne, Z.G.
President
RAP:rp
Attachments
UNDERGROUND STORAGE TANK
CLOSURE ASSESSMENT REPORT FOR
7527 GLENCANNON DRIVE
CHARLOTTE, NORTH CAROLINA
Prepared for:
Mr. Ryan Kozusko
Charlotte, North Carolina
Prepared by:
Cedar Rock Environmental, P.C.
107 Pioneer Trail
Graham, North Carolina
Robert A. Payne, L.G.
President
September 24, 2020
CR #302222590
Section
TABLE OF CONTENTS
1.0 INTRODUCTION
2.0 PROJECT
FIGURE
Site Map
APPENDICES
A Fluid Disposal Manifest
B Photographic Documentation
Page No.
I hereby certify this 24th day of September 2020 that this report was prepared by me or under my
direct supervision. ..&#"
Robert A. Payne, L.G
Geologist
ii
1.0 INTRODUCTION
Cedar Rock Environmental, P.C. (Cedar Rock) was contacted by Mr. Ryan Kozusko of Charlotte,
North Carolina to abandon in -place an underground storage tank (UST) located at 7527
Glencannon Drive in Charlotte, North Carolina. The UST was first inspected on September 7,
2020. An inactive UST was observed to be located parallel to and centered beneath the
easternmost northern foundation wall the house (sunroom) and about 6.0 feet west of the
easternmost northeastern corner of the house (sunroom). Both the fill and vent pipe(?) of the UST
were observed to be intact and elbowed out from beneath the sunroom slab with the suspected vent
pipe being capped. The depth to the top of the UST is approximately 26 inches below land surface
(bls). The UST has a length of about 79 inches with a diameter of approximately 43 inches and
an estimated capacity of about 500 gallons. The contents of the UST could not be determined as
there was no direct access to the interior of the tank. White flagging was installed to mark the ends
of the UST. No other USTs on the property were discovered using a metal detector to survey the
outside perimeter of the residence where USTs are usually located. A single copper fuel delivery
line was observed to be cut and crimped inside the crawlspace. No petroleum odors were observed
in the crawlspace from the crawlspace entry in the sunroom.
Once the orientation of the UST was determined, a soil boring was performed along the northern
side of the tank at its western end using a 3.25-inch diameter stainless steel hand auger. The soil
boring was advanced to a depth of approximately 3.0 feet bls, about 3.0 feet above the bottom of
the UST. A strong petroleum odor and local discoloration was observed in the soils from a depth
of approximately 2.5 to 3.0 feet bls suggesting significant leakage from the UST has occurred.
The soils at the base of the boring consist of an orange brown sandy silt.
2.0 PROJECT
The in -place abandonment of the UST was performed on September 21, 2020. The abandonment
consisted of the hand excavation of the soils overlying the western end of the UST to expose the
topside of the tank. A hole approximately 1.5 feet in diameter was then cut on the top of the UST
to allow for removal of the tank contents, cleaning and visual inspection of the UST interior, and
subsequent filling. The tank was pressure washed to remove all residual petroleum sludge. A
vacuum was placed on the fuel line in an attempt to remove any residual oil within the line.
Approximately 520 gallons of fluid and sludge (including rinsate) were removed from the UST.
The fluid disposal manifest for the tank contents is included in Appendix A.
After the interior of the UST was cleaned, the tank was then entirely filled with an excavatable
flowable fill cement slurry. Once filled, the exposed portion of the UST was then covered with
site soils (see Appendix B - Photographic Documentation).
1
FIGURE
SITE MAP
4
0 5 10 20
: T1 = 500-Gallon UST
1 Inch = 10 Feet
PROJECT: Ryan Kozusko Property
INCIDENT # Pending
LOCATION: 7527 Glencannon Drive
Charlotte Mecklenburg Co.
CRE PROJECT NUMBER: 302222590
CEDAR ROCK
ENVIRONMENTAL, P.C.
FILENAME:
VERSION DATE
3022-Fig7.fc7
9/22/2020
SITE MAP
FIGURE 1
APPENDIX A
FLUID DISPOSAL MANIFEST
MATERIAL
MANIFEST
EMERGENCY PHONE NO.
(336) 841-5276
Name
Street Address
DESCRIPTION OF MATERIALS
Manifest Document No.
Page of
tnrkonmen)ai & H.dwtiia! Sm. ricer
POST OFFICE BOX 357 TEL (336) 841-5276 I Zebra Job No.
HIGH POINT, NC 27261 FAX (336) 841-5509
GENERATOR INFORMATION
Mailing Address
Phone No.
ontact
USDOT Proper Shipping Name
HMI (Complete All Items for Hazardous Materials)
Hazard
Class or Div
UN / NA
ID No.
Packing
Group
Containers
Qty. Type
Total
Quantity
Unit
Wt./vol.
a.
b.
C.
ADDITIONAL INFORMATION
ERG No.
Zebra Profile Code
Facility Use
a.
b.
C.
GENERATOR'S CERTIFICATION
This is to certify that the above -described materials are properly classified, described, packaged, marked and labeled, and are in
proper condition for transportation according to the applicable regulations of the Department of Transportation. 1 further certify that
none of the materials described above are a hazardous waste as defined by EPA 40 CFR Part 261 or any applicable state law, and
unless specifically identified above, the materials contain less than 1, 000 ppm total halogens and do not contain quantifiable levels
(2 ppm) of PCBs as defined by EPA 40 CFR Parts 279 and 761.
me
ay
TRANSPORTER
INFORMATION
Transporter Zebra Environmental & Industrial Services Inc
I hereby acknowledge receipt of the above -described materials for transport
from the generator site listed above.
Address
901 East Springfield Road
High Point, NC 27263
Signature Shipment Date
I hereby acknowledge receipt of the above -described materials were received
from the generator site and were transported to the facility listed below.
Transporter or
NCO991302669
Unit No.
EPA ID No.
Signature Delivery Date
Phone (336) 841-5276
FACILITY INFORMATION
Facility Zebra Environmental & Industrial Services, Inc.
I hereby acknowledge receipt of the materials covered by this manifest
except for any discrepancy noted below.
Address
901 East Springfield Road
High Point, NC 27263
Signature Receipt Date
Discrepancies t Routing Codes / Handing Methods
Facility or NC0991302669
EPA 1D No.
a'
Phone (336) 841-5276
b.
Contact gill Hunter
C.
ORIGINAL - Facility Retain COPY 2 - Return to Generator COPY 3 - Transporter Retain COPY 4 - Generator Retain
APPENDIX B
PHOTOGRAPHIC DOCUMENTATION
Photo 1. View of the UST site prior to abandonment activities.
Photo 2. View of the UST interior prior to the removal of tank contents.
Photo 3. View of the UST interior after the removal of UST contents and
pressure wash cleaning of the tank interior.
Photo 4. View of the UST being filled with flowable fill cement slurry.
r
r
'y
Jr.,a
Photo 5. View of the UST after filling with flowable fill cement slurry.
Photo 6. View of the UST site after the completion of abandonment activities.
Beverly, Trudy
From: damienkc@bellsouth.net
Sent: Tuesday, December 22, 2020 11:03 AM
To: Beverly, Trudy
Subject: [External] Ryan Kozusko Property reports
Attachments: RyanKozusko-Abandonment 3022.pdf, RyanKozusko-Inspection 3022.pdf
CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to
Report Spam.
Ryan Kozusko property reports attached.
Damien
Beverly, Trudy
From: Beverly, Trudy
Sent: Tuesday, December 22, 2020 11:06 AM
To: damienkc@bellsouth.net
Subject: RE: [External] Ryan Kozusko Property reports
Received.
Trudy
Trudy Beverly, L.G.
D
IE �1
Hydrogeologist, Division of Waste Management
_ North Carolina Department of Environmental Quality
Q�
LF Pa.rI n. of Lnorun,w 0MOT ` UST Section, Mooresville Regional Office
704.235.2182 (Office)
Trudy. B everlykncdenn gov
Email correspondence to and from this address is subject to the
North Carolina Public Records Law and may be disclosed to third parties.
Office Mailing Address:
610 East Center Avenue, Suite 301
Mooresville, NC 28115
Branch's Underground Storage Tanks Website Address: ht_pt s://deg.nc.gov/about/divisions/waste-management/ust
Branch's Above Ground Storage Tanks Website Address: hgps:Hdeg.nc.gov/about/divisions/waste-management/ust/ast-proeram
INTERACTIVE MAPS WITH DWM SITES AND PERMITTED FACILITIES:
httns://deu.nc. eov/about/divisions/waste-manaeement/waste-manaeement-rules-data/waste-manaeement-eis-mans
File Review Procedures:
ht_pt s://deq.nc.gov/about/divisions/waste-manaeement/ust/file-review-procedures#mooresville-regional-office
ONLINE ACCESS TO UST SECTION DOCUMENTS (Laserfiche):
httns: //dea.nc. eov/about/divisions/waste-manaeement/laserfiche
Document Submittal & UST File Names for Laserfiche Policies:
httys:Hfiles.nc.eov/nedea/Waste%2OMana2ement/DWM/UST[WhatsNew/Final-Electronic-Document-Submittal-Policy.odf
https:Hfiles.nc.gov/ncdeg/Waste%2OManagement/D WM/UST/Corrective%2OAction/UST%20file%20names%20for%2OLaserfiche.docx
From: damienkc@bellsouth.net [mailto:damienkc@bellsouth.net]
Sent: Tuesday, December 22, 2020 11:03 AM
To: Beverly, Trudy <trudy.beverly@ncdenr.gov>
Subject: [External] Ryan Kozusko Property reports
CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to
Report Spam.
Ryan Kozusko property reports attached.
Damien