Loading...
HomeMy WebLinkAbout23008_500 W Trade St_SIR_20210119DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 01/19/2021 3:10 PM I.Inspection Information Date & Time: 01/19/2021 8:59 AM Inspection Type: Meeting Brownfields Staff: Kevin Slaughter Other Personnel: Greg Icenhour, Dan Nielsen-S&ME, Niel Edwards & Walt Morris - Northwood Raven Location: Lat: 35.23207, Long: -80.84682, Brownfields Inspection Report: Mecklenburg Hotel, 23008-19-060 01/19/2021 8:59 AM Page 2 of 6 II.Project Information Number: 23008-19-060 Name: Mecklenburg Hotel Address: 500 West Trade Street City: Charlotte County: Mecklenburg III. Environmental Current Use of Property: Commercial/Retail, Mixed Use, Residential Structures on Property: New Structures Violation: No Vapor Mitigation Systems: Observed Vapor Mitigation Violation: Unknown Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Exposed Soils: Not Observed Exposed Soils Violation: No Summary: Both active and passive (non-vented barrier) systems present. Active systems require pour-back area repair, completion of some risers, riser labels, and fan installation (following pre-occupancy sampling). Summary: N/A Summary: Mixed use retail/apartment building Summary: N/A Brownfields Inspection Report: Mecklenburg Hotel, 23008-19-060 01/19/2021 8:59 AM Page 3 of 6 Use of Basements: Not Observed Basement Violation: No Storage of Chemicals: Not Observed Chemical Violation: No Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: N/A Summary: N/A Condition: Summary: N/A No risks observed with exception of pour-back areas within enclosed space that need repair. Brownfields Inspection Report: Mecklenburg Hotel, 23008-19-060 01/19/2021 8:59 AM Page 4 of 6 IV.Inspector Comments V.PHOTOGRAPHS Photo 1: View of residential portion of site looking north from 5th street. Onsite to meet with S&ME personnel to discuss vapor monitoring point location and installation methods. During site visit, observed that pour-back areas had not been repaired that were discussed during June 2020 site visit. Discussed need to repair pour- back areas now that building shell was closed in, and that it would need to be done prior to pre-occupancy sampling being discussed. Walked all mitigated areas of site including roof-top to observe risers that have terminated above the roof so far. S&ME to produce a pre-occupancy sampling Work Plan prior to sampling. Brownfields Inspection Report: Mecklenburg Hotel, 23008-19-060 01/19/2021 8:59 AM Page 5 of 6 Photo 2: Pour-back area in need of repair in northern corner of building. Vapor collection pit, and 6” dia. steel riser piping visible in upper right of photograph. Photo 3: Exposed VIMS barrier in pour-back area. All pour back areas to be repaired prior to pre-occupancy sampling. Brownfields Inspection Report: Mecklenburg Hotel, 23008-19-060 01/19/2021 8:59 AM Page 6 of 6 Photo 4: Close up of VIMS vapor collection pit. Photo 5: Roof top riser termination prior to installation of electric VIMS fans. Electrical conduit visible adjacent to 6” dia. PVC exhaust riser.