Loading...
HomeMy WebLinkAbout0601_AveryCounty_MSWLF_Dec20LFG_FID1525978_20210119DocuSign Envelope ID: 94A4E2BA-9F31-4125-90EE-104A49CBD747 SMITH{ GARDNER ENGINEERS January 18, 2021 Ms. Jaclynne Drummond NCDENR DWM Solid Waste Section 2090 U.S. 70 Highway Swannanoa, North Carolina 28778-8211 ABBRESS TEL WEB 14 N. Boylan Avenue, Raleigh NC 27603 919.828.0577 www.smithgardnerinc.com RE: Operations, Monitoring, and Maintenance Report — December 2020 Avery County Closed MSW Landfill (Permit No. 06-01) Spruce Pine, North Carolina Dear Ms. Drummond: On behalf of Avery County (County), Smith Gardner, Inc. (S+G) is pleased to present this report regarding the operation and maintenance (0&M) of the Avery County Closed MSW Landfill (Permit No. 06-01) Landfill Gas Collection and Control System (LFGCCS), and the perimeter monitoring probes for December 2020. Site details are provided below. SITE HISTORY The Avery County Closed MSW landfill is located approximately 0.6 miles southeast of the intersection of Highway 19 and Brushy Creek Mountain Road next to the Avery County Airport and the Unimin Corporation sand mine facility. There is no active mining in the immediate vicinity of the landfill. The MSW landfill was operated from 1970 until it closed in 1993. The property consists of approximately 14.4 acres, with the landfill footprint occupying approximately 9.6 acres of the site. Landfill topography ranges in elevation from approximately 2770 ft. msl to 2670 ft. msl, and slopes downhill toward Brushy Creek. Landfill gas monitoring and LFGCCS maintenance is completed on a monthly basis due to landfill gas concentrations detected in monitoring probes off -site. LFG COLLECTION AND CONTROL SYSTEM MONITORING ACTIVITIES The site has an active Landfill Gas Collection and Control System (LFGCCS) consisting of 10 landfill gas extraction wells (W-1 through W-10), HDPE piping for transmission of collected landfill gas, a one (1) horsepower blower, a condensate trap and storage tank, a candlestick flare, and associated valves and gauges. Well field and flare station data are provided in the attached Table 1. DocuSign Envelope ID: 94A4E2BA-9F31-4125-90EE-104A49CBD747 Ms. Drummond January 18, 2021 Page 2of4 LFG Extraction Well Field • W-1 through W-10: S+G performed methane (CH4), oxygen (02), and carbon dioxide (CO2) monitoring as well as flow and pressure monitoring. In general, gas quality has a wide variance across the wellfield. W-6 and W-10 had recorded oxygen levels above 5% this sampling event. These two extraction wells will be evaluated for any leaks or maintenance issues, which will be corrected, and continued to be monitored and tuned as necessary during the January 2021 sampling event. Flare Station Gas quality measured at the flare is nominal with moderate levels recorded of methane, and higher levels recorded of oxygen. The higher oxygen levels may be a result of higher oxygen levels measured in the wellfield, and will be investigated further. The wellfield will continue to be monitored, tuned, and maintained as necessary to identify potential issues with the system and to keep gas quality levels nominal. LFG MONITORING WELL (PERIMETER) MONITORING PROGRAM S+G performed monitoring of the perimeter LFG monitoring network during this event. The network consists of probes P-1 through P-13 located around the facility, and in some cases, on adjacent properties. Monitoring results for this month indicate the following probes have landfill gas concentrations above the LEL: • P-3 It should be noted that P-3 is located on the landfill property, immediately adjacent to waste on the northern boundary of the site. The concentration in P-3 is significantly lower than the peak observed in fall of 2019. Monitoring probe P-7, also located on the landfill property adjacent to waste, had a methane concentration of 2.6% this month. This is below the LEL, and is slightly lower than previous events. P-7 will continue to be monitored closely. Off -site monitoring probes, P-1, P-2, P-4, P- 6, P-9, P-10, P-12 and P-13 all exhibited methane concentrations of 0%. Attachment 1 includes the monitoring forms with results while Attachment 2 provides a CH4 concentration graph over time for monitoring wells that have historically had methane present. Monitoring of the current well network will continue, and data will be reported to NCDEQ and the County. CONCLUSIONS In general, the landfill gas extraction system continues to operate nominally. Elevated levels of oxygen were measured in two landfill gas extraction wells during this sampling event. S+G will continue to monitor the methane concentrations at the site monthly, and advise the County as needed on repairs required to maintain an effective collection system. DocuSign Envelope ID: 94A4E2BA-9F31-4125-90EE-104A49CBD747 Ms. Drummond January 18, 2021 Page 3of4 The next monitoring event is scheduled for January 2021. If you have any questions, or require additional information, please contact us at your earliest convenience at 919-828-0577 or by e-mail (address below). Sincerely, SMITH GARDNER, INC. N CAR � 'F S Si0 ��/ti. j rQPO �� • ; DocuSignedby: = SEAL 1/19/20L21 �PUA t ,v� ili1. RbUhmm�t 046707 ` z 81313721KE5F488... 41 �.t r:• O Spencer W. Hollomon, P.E. %�' �`.FN ��'' 0 Project Engineer, ext. 134 �rr.t� ,R�W`�N,11` SDencer(asmithaardnerinc.comuntn1% Attachments cc: Eric Foster - Avery County file CAlpO`� Q. N � p SSF,1'.gL DocuSigned by: 1 369 E ba� Q. SM 5� B9779EBA711F488... Joan A. Smyth, P.G. A. S Senior Hydrogeologist A. 22��� ioan(asmithaardnerinc.com H:\Projects\Avery County INCI\02 AC Compliance\LFG Monitoring\MSW\2020\12 December 2020onitoring Report.docx 1 DocuSign Envelope ID: 94A4E2BA-9F31-4125-90EE-104A49CBD747 Ms. Drummond January 18, 2021 Page 4of4 This page intentionally left blank. DocuSign Envelope ID: 94A4E2BA-9F31-4125-90EE-104A49CBD747 FIGURES DocuSign Envelope ID: 94A4E2BA-9F31-4125-90EE-104A49CBD747 ti or P'0-6�40' 41 . .r,r.tf fr '� i•1 110, 11w �� • op # 04. w#` If• r/ r~ �� � ice' ' •f�c • +�l. kit • • # U 7 % # '* i4L a 96..E • .� r .• - r + . :Opp + P 4 e+ 1 ■ • , a �r ► F Oro- - 40 ii�ss a'' :,P • LEGEND - T� � ' 1. • 04 0 EXISTING LANDFILL GAS PROBE • +• ® OFFSITE STRUCTURE TO BE ' •^ ■ MONITORED ,,. •�;�` REFERENCES «� 1. ADJACENT PROPERTIES ARE FROM AVERY COUNTY GIS MAPPING DEPARTMENT. rom F.w' _• r 2. MONITORING WELL LOCATIONS FROM FIELD SURVEY DATED 1/14/08, BY `pSURVEYING SOLUTIONS, P.C. '} _ 3. PROPERTY LINE FROM FIELD SURVEY DATED APRIL 9, 2010, BY .1�►.,N APPALACHIAN PROFESSIONAL LAND SURVEYORS & CONSULTANTS. ` 4. LFG PROBES LOCATIONS FROM FIELD SURVEY DATED APRIL 9, 2010, BY APPALACHIAN PROFESSIONAL LAND SURVEYORS & CONSULTANTS. ` �, - : PROBE P-2, P-3, AND P-9 THROUGH P-13 LOCATIONS WERE NOT A.a goo- � ; SURVEYED AND ARE APPROXIMATE. H < + , • 0 200' 400' • Y4l 0 r �� f J Z J cn o W d C/7 C j � U Q y x cm y o � J V J a LL. Z CU Z J Z O a G U W >- c.3 x x W d Q en DocuSign Envelope ID: 94A4E2BA-9F31-4125-90EE-104A49CBD747 TABLES DocuSign Envelope ID: 94A4E2BA-9F31-4125-90EE-104A49CBD747 SMITH GARDNER TABLE 1 Avery County Closed MSW Landfill Landfill Gas Collection and Control System Monitoring December 2020 DATE: December 28, 2020 BY: MJL Device10 Date/Time CH4 C62 02 Balance Init. Temperature Init. Static Pressure Adj. Static Pressure Init. Diff. Pressure* Init. Flow Adj. Flow System Pressure mm/dd/yyyy % % % % deg F in H2O in H2O in H2O Scfm Scfm in H2O AVERY-WI 12/22/2020 62.6 26.6 1.1 9.6 48 -39.05 -39.11 0.045 0 0 -38.35 AVERY-W2 12/22/2020 69.5 24.5 0.5 5.5 53 -39.49 -39.68 0.207 0 0 -39 AVERY-W3 12/22/2020 67 25.5 0.9 6.6 56 -39.95 -40.02 0.222 0 0 -39.74 AVERY-W4 12/22/2020 38 17.1 0.7 44.2 54 -39.65 -39.84 0.002 0 0 -38.02 AVERY-W5 12/22/2020 38.7 26.4 0.9 33.9 53 -32.3 -32.28 0.435 0 0 -32.27 AVERY-W6 12/22/2020 7.2 15.4 7.6 69.8 56 -39.78 -39.78 0.044 0 0 -39.77 AVERY-W7 12/22/2020 42.2 26.3 0 31.5 55 -19.91 -19.85 0.167 0 0 -19.77 AVERY-W8 12/22/2020 49.6 33.8 0.2 16.4 54 -39.96 -39.98 0.005 0 0 -39.93 AVERY-W9 12/22/2020 51.4 24.8 0.1 23.6 55 -39.07 -39.14 -0.004 0 0 -38.57 AVERY-W10 12/22/2020 6.8 3.8 18.6 70.8 53 -14.62 -38.85 0.002 0 0 -38.02 Av-Flare 12/22/2020 29.7 19.1 6.8 37.5 58 3.43 3.49 -0.92 0 0 3.14 *The differential pressure measurement should be positive. A negative differential pressure may indicate no gas flow. Negative differential pressure can be the result of dirt or water obstructing the pitot tube perforations. Overpulling by adjacent extraction wells may also result in negative pressure being displayed. NR= not recorded DocuSign Envelope ID: 94A4E2BA-9F31-4125-90EE-104A49CBD747 ATTACH MENT 1 PERIMETER MONITORING PROBE DATA DocuSign Envelope ID: 94A4E2BA-9F31-4125-90EE-104A49CBD747 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). FacilityName: Arj g9Lkf-&P[Q,4eLdlM§ L990filLandf ill Permit Number: 06 AL O 1 Date of Sampling: 12/22/2020 NC Landfill Rule (.0500 or .1600): .050@500 Name and Position of Sample Collector: Michael J. Liebl - Staff Environmental Technician Type and Serial Number of Gas Meter: GEM50001 G506472 Date and Time of Field Calibration: 12/22/2020, 1152 Calibration Date of Gas Meter: 12/2020 Type of Field Calibration Gas (15115 or 35/50): 35/15 Expiration Date of Field Calibration Gas Canister: 10/2022 Pump Rate of Gas Meter: 0.5 LPM Ambient Air Temperature: 48 F Barometric Pressure: 29.97 inHg General Weather Conditions: Sunny Instructions: Under "Location or LFG Well" identify the monitoring wells or describe the location for other tests (e.g., inside buildings). A drawing showing the location of test must be attached. Report methane readings in both % LEL and % methane by volume. A reading in percent methane by volume can be converted to % LEL as follows: % methane by volume = % LEL/20 Location or LFG Well ID Sample Tube Purge Time Time P--ped (s) InitW o/uLEL Stabilized 01nLFL 11/XH4 by Volume %0-2 %IoCO2 Notes H 2S p p m P-1 >60s 1359 >60s 0 0 0.0 20.1 0.2 0 P-2 >60s 1404 >60s 0 0 0.0 19.8 0.1 0 P-3 >60s 1410 >60s 226 226 11.3 9.7 12.4 3 P-4 >60s 1416 >60s 0 0 0.0 19.6 0.5 1 P-5 >60s 1347 >60s 2 2 0.1 19.8 2.2 2 P-6 >60s 1335 >60s 0 0 0.0 20.2 1.6 2 P-7 >60s 1328 >60s 52 52 2.6 16.5 3.8 2 P-8 >60s 1320 >60s 4 4 0.2 18.3 2.3 1 P-9 >60s 1431 >60s 0 0 0.0 19.2 0.1 1 P-10 >60s 1435 >60s 0 0 0.0 20.0 0.1 1 P-11 >60s 1422 >60s 2 2 0.1 20.0 2.1 0 P-12 >60s 1324 >60s 0 0 0.0 19.9 1.7 2 P-13 >60s 1448 >60s 0 0 0.0 19.0 0.2 1 Airport Structures >60s 1452 >60s 0 0 0.0 20.4 0.1 0 If your facility has more gas monitoring locations than there is room on this form, please attach additional sheets listing the same information as contained on this form. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are sign tptuecfroyroaldng any false statement, representation, or certification including the possibility of a fine and imprisonment. COFF2284CA504F5... Environmental Technician SIGNATURE TITLE DocuSign Envelope ID: 94A4E2BA-9F31-4125-90EE-104A49CBD747 ATTACHMENT 2 HISTORICAL PERIMETER MONITORING PROBE TRENDS DocuSign Envelope ID: 94A4E2BA-9F31-4125-90EE-104A49CBD747 M11111stMA11,111V Avery County MSW Landfill Landfill Gas Monitoring Well Network Volume Rio by Methane Concentrations Between January 2014 and December 2020 By: MJL Date: 12/28/2020 80.0 Installation of W9/P3 Connection Installation of P7/W8 and P1/W10Connection (September 11, 2014 P (September 3, 2015) 70.0 60.0 , 50.0 40.0 30.0 20.0 ' 10.0 0.0 , v L v R* v v v'zj- r0 -�t Ln Ln i Ln Ln Ln Ln Ln Ln Ln L LO LO W c-I r-I �' a --I c-I a --I c-I r-I i r, � � r > c-I a-i � 00 00 'L 00 00 00 00 00 00 00 M rn L rn airnairnai rnoo � 0 00000 0 L N T N N N N N 0 N � r0 C g i 2i C bA Q V O Z U C-0 i C W Q V O Z U C-0 C W QV O Z U C-0 C W QV O Z U C-0 Cba-+ O r0 O Z U C-0 C— bA 0-+Z U Cn3-0 ra O C— z U r0 LL Q�n O Q Qn O LL Q Qn O LL Q Qn O LL Q Qn O LL Q Qcn O LL Q Qcn O P1 Well P3 P7 Certificate Of Completion Envelope Id: 94A4E2BA9F31412590EE104A49CBD747 Subject: Please DocuSign: December 2020 Avery MSW LFG Monitoring Report Final.pdf Source Envelope: Document Pages: 12 Signatures: 3 Certificate Pages: 2 Initials: 0 AutoNav: Enabled Envelopeld Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) Record Tracking Status: Original 1/18/2021 9:43:46 AM Signer Events Michael Liebl michael@smithgardnerinc.com Environmental Technician Smith Gardner, Inc. Security Level: Email, Account Authentication (None) Electronic Record and Signature Disclosure: Not Offered via DocuSign Spencer W. Hollomon spencer@smithgardnerinc.com Project Engineer Smith Gardner, Inc. Security Level: Email, Account Authentication (None) Electronic Record and Signature Disclosure Not Offered via DocuSign Joan A. Smyth joan@smithgardnerinc.com Vice President Smith Gardner, Inc. Security Level: Email, Account Authentication (None) Electronic Record and Signature Disclosure: Not Offered via DocuSign In Person Signer Events Editor Delivery Events Agent Delivery Events Intermediary Delivery Events Certified Delivery Events Carbon Copy Events Holder: Michael Liebl michael@smithgardnerinc.com Signature ED11"Sil"Id by: COFF2284CA504F5... Signature Adoption: Pre -selected Style Using IP Address: 24.106.183.110 by: EDICUSig"Id pwLu r K NbUaKow 8813721B7E5F488... Signature Adoption: Pre -selected Style Using IP Address: 24.106.183.110 ocuSigned by: ED bw& Q. SPA B9779EBA711 F488... Signature Adoption: Pre -selected Style Using IP Address: 24.106.183.110 Signature Status Status Status Status Status Docu5�". 6 S E C U R E 6 Status: Completed Envelope Originator: Michael Liebl 14 N. Boylan Ave Raleigh, NC 27603 michael@smithgardnerinc.com IP Address: 24.106.183.110 Location: DocuSign Timestamp Sent: 1/18/2021 9:49:52 AM Viewed: 1/18/2021 9:50:09 AM Signed: 1/18/2021 9:50:19 AM Sent: 1/18/2021 9:50:20 AM Viewed: 1/18/2021 10:57:00 AM Signed: 1/18/2021 10:57:58 AM Sent: 1/18/2021 10:57:59 AM Viewed: 1/18/2021 11:26:15 AM Signed: 1/18/2021 11:26:21 AM Timestamp Timestamp Timestamp Timestamp Timestamp Timestamp Carbon Copy Events Status Michael Liebl COPIED michael@smithgardnerinc.com Environmental Technician Smith Gardner, Inc. Security Level: Email, Account Authentication (None) Electronic Record and Signature Disclosure: Not Offered via DocuSign Witness Events Signature Notary Events Signature Envelope Summary Events Status Envelope Sent Hashed/Encrypted Certified Delivered Security Checked Signing Complete Security Checked Completed Security Checked Timestamp Sent: 1/18/2021 11:26:22 AM Timestamp Timestamp Timestamps 1 /18/2021 9:49:52 AM 1 /18/2021 11:26:15 AM 1 /18/2021 11:26:21 AM 1 /18/2021 11:26:22 AM Payment Events Status Timestamps