HomeMy WebLinkAbout6301_MooreCounty_MSWLF_CDLF_Dec2020LFG_FID1523714_20200112ENR USE ONLY: ❑Paper Report ❑Electronic Data -Email CD data loaded: Yes / No Doc/Event #:
NC DENR I Environmental Monitoring
Division of Waste Management - Solid Waste Reporting Form
Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Instructions:
• Prepare one form for each individually monitored unit.
• Please type or print legibly.
• Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification
must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing
condition, etc.).
• Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits.
• Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the
facility (NCAC 13B .1629 (4)(a)(i).
• Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste
Section, 1646 Mail Service Center, Raleigh, NC 27699-1646.
Solid Waste Monitoring Data Submittal Information
Name of entity submitting data (laboratory, consultant, facility owner):
S&ME, Inc. (on behalf of Moore County)
Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address:
Name: Edmund Q.B. Henriques Phone: 336-288-7180
E-mail: ehenriques@smeinc.com
NC Landfill Rule: Actual sampling dates (e.g.,
Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006)
Moore County Landfill 456 Turning Leaf Way, Aberdeen, NC 63-01 .0500 December 11, 2020
Environmental Status: (Check all that apply)
F] Initial/Background Monitoring [_Xj Detection Monitoring Assessment Monitoring Corrective Action
of data submitted: (Check all that apply)
Groundwater monitoring data from monitoring wells Fx
Groundwater monitoring data from private water supply wells F-1
Leachate monitoring data ❑
Surface water monitoring data
Methane gas monitoring data
Corrective action data (specify)
Other(specify)
Notification attached?
No. No groundwater or surface water standards were exceeded.
Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water
monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and
preliminary analysis of the cause and significance of any concentration.
F_x]Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample
values and explosive methane gas limits.
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct.
Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas
levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there
are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment.
Edmund Q.B. Henriques, PG
Facility Representative Name (Pr
iifn (3 A.4
Signature
Senior Geologist, S&ME Inc. 336-312-3330
Title
8646 W. Market Street, Suite 105, Greensboro NC 27409
Facility Representative Address
F-0176
NC PE Firm License Number (if applicable effective May 1, 2009)
Revised 6/2009
12/23/2020
Date
(Area Code) Telephone Number „
Affix NC Licensed/ Profes�siona;l Geologist Seal
�m p
�iYM O rc,�,,,
N, �,�G s ;
41
0 Gt
. ;: �, ,,�„, :-„,,,.;,�,r"".75i'" rR►� Cam
h __J
NC Division of Waste Management - Solid Waste Section
Landfill Gas Monitoring Data Form
Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Facility Name: Moore County Landfill Permit Number: 63-01
Sampling Date: 12/11 /2020
NC Landfill Rule (.0500 or .1600): 0.0500
Sample collector Name & Position: Gary Simcox / Environmental Technician
Gas Meter Type & Serial Number: GEM 5000 Plus / G504951 Gas Meter Calibration Date: 1 2/8/2020
Field Calibration Date & Time: 12/08/2020
Field Calibration Gas Type (15115 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 4/1 /25
Gas Meter Pump Rate: 680 cc/min
Ambient Air Temperature: 55 Barometric Pressure (in. or mm Hg): 29.76 Weather Conditions: Sunny
Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office).
Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume.
Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)x 20 = % LEL.
*Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual
permit conditions and/or Facility LFG monitoring plan.
Location or
LFG Well ID
S ample
Tube
Purge
Time of
Day
Time
Pumped
(sec)
Initial
% LEL
Stabilized
% LEL
% CH4
volume
(volume)
% 02
(volume)
% CO2
(volume)
% H2S*
(volume)
NOTES
GP-9
60
1130
180
1 0
0
0.1
21.3
0.1
0.0
property boundary
GP-1 OR
60
1145
240
0
0
0.0
17.5
3.3
0.0
property boundary
GP-11
60
1138
180
0
0
0.0
16.1
4.1
0.0
property boundary
GP-12
60
1200
180
0
0
0.0
19.8
1.0
0.0
property boundary,
GP-13R
60
1210
240
0
0
0.0
20.0
1.4
0.0
property boundary
GP14R
60
1218
240
0
0
0.0
19.2
1.1
0.0
property boundary
GP-15R
60
1230
240
0
0
0.0
19.7
.9
0.0
property boundary
GP-16
60
1243
240
0
0
0.0
9.7
11.4
0.0
property boundary
GP-17
60
1253
240
0
0
0.5
2.1
14.5
0.0
property boundary
GP-18
60
1333
180
>5
>5
61.3
0.1
36.1
2.0
property boundary
GP-19
60
1304
240
0
0
0.0
19.0
2.9
0.0
property boundary
NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility.
ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary)
Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary)
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments
are true and correct. I am aware that there are significant penalties for making any false statement, representation,
or certification including the possibility of a fine and imprisonment.
Environmental Technician
SIGNATURE TITLE
Revised - February 4, 2020
NC Division of Waste Management - Solid Waste Section
Landfill Gas Monitoring Data Form
Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Facility Name: Moore County Landfill Permit Number: 63-0 1
Sampling Date: 12/11 /2020 NC Landfill Rule (.0500 or. 1600): 0.0500
Sample collector Name & Position: Gary Simcox / Environmental Technician
Gas Meter Type & Serial Number: GEM 5000 Plus / G504951
Field Calibration Date & Time: 12/8/2020
Field Calibration Gas Type (15115 or 35/50): 15/15
Gas Meter Pump Rate: 680 cc/min
Ambient Air Temperature: 55
Gas Meter Calibration Date: 1 2/8/2020
Field Calibration Gas Canister Expiration Date: 4/1 /25
Barometric Pressure (in. or mm Hg): 29.76 Weather Conditions: Sunny
Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office).
Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume.
Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)x 20 = % LEL.
*Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual
permit conditions and/or Facility LFG monitoring plan.
Location or
LFG Well ID
S ample
Tube
Purge
Time of
Day
Time
Pumped
(sec)
Initial
% LEL
Stabilized
% LEL
% CH4
(volume)
volume
% 02
(volume)
% CO2
(volume)
% H2S*
(volume)
NOTES
MW-6
60
13101
120
>5
>5
9.6
13.6
6.5
0.0
MW-6 is not at facility boundary
GV-33
60
1325
120
>5
>5
45.0
0.1
34.9
1.0
vent for gas cut-off trench
GV-34
60
1318
120
>5
>5
52.2
0.2
37.4
4.0
vent for gas cut-off trench
Blake Residence
60
1100
60
0
0
0.1
21.5
0.1
0.0
inside crawispace door
Maintenance shop
60
1342
120
0
0
0.0
20.9
0.1
0.0
inside on -site structure
Transfer station
60
1400
120
0
0
0.0
21.1
0.9
0.0
inside on -site structure
Scale House
60
1410
120
0
0
0.0
21.2
0.1
0.0
inside on -site structure
NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility.
ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary)
Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary)
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments
are true and correct. I am aware that there are significant penalties for making any false statement, representation,
or certification including the possibility of a fine and imprisonment.
Environmental Technician, S&ME Inc.
SIGNATURE TITLE
Revised - February 4, 2020
Table 1
Summary of 2020 Methane Gas Readings
Moore County Landfill (Permit 63-01)
Moore County, North Carolina
S&ME Project No. 4358-20-043A
_
,
r7-A
02/17/20
0.0%
0.0%
0.0%
0.0%
0.0% 18.7%
0.0%
0.0% 0.0%
0.0% 0.0%
0.0% 0.0%
0.0%
0.0%
0.0%
11.9%
28.1 %
04/07/20
0.0%
0.0%
0.0%
0.0%
0.0% 32.2%
0.0%
0.0% 0.0%
0.0% 0.0%
0.0% 0.0%
0.0%
0.0%
0.4%
23.6%
59.9%
09/15/20
0.1%
0.0%
0.0%
0.0%
0.1% abandoned
0.0% 0.0%
0.0% abandoned
0.0% abandoned
0.0% abandoned
0.0%
0.0%
0.0%
0.0%
22.5%
0.0%
12/14/20
0.0%
0.0%
0.0%
0.1%
0.1% abandoned
0.0% 0.0%
0.0% abandoned
0.0% abandoned
0.0% abandoned
0.0%
0.0%
0.5%
9.6%
61.3%
0.0%
Notes:
Monitoring Point Types: PB = Property Boundary, ONSS = On Site Structure, OFFSS = Off -site Structure
Note* = MW-6 was replace by GP-19 as the property boundary compliance point. MW-6 is approximately 150 feet inside the property boundary.
all measurements recorded in percent methane by volume
Lower explosive limit of methane gas: 5%
Upper explosive limit of methane gas: 15%
All data recorded prior to 9/15/20 supplied by Golder
-- Indicates no measurement recorded/obtained.
Yellow highlight cells and values in bold print indicate methane percent by volume greater than or equal to 5% at property boundary monitoring point
Orange highlight cells and values in bold print indicate methane percent by volume greater than or equal to 1.25% inside structures.
Z:\Shared\SME\Op,\ENV\Projec[ \2020\4358-20-043A Moore County Routine LFG & WQ Monitoring\Task 02 - Quarterly Landfill Gas\Field Data\LFG Readings T ble..I,.
ENVIRO—EQUIPMENT, INC.
LANDTEC GEM 5000 Plus CALIBRATION DATA SHEET
Serial Number Date Inspector
Time/Date �C �i�L. Battery Level ru Memory Cleared Pump Faults Q ,ALA .
Gas Alarms: CHa = 100.0% C��g� CO2 = 100.0% 02 = 22.0% ��
Zero Transducers Chu _ Pump Flow Rate Z\ c "/rni r-N Vacuum Tested To 80" HzD �^
Calibration Gas
Pure N2
High CH.$
High CO2
Low CH,
Law CO2
Low 0,
High 02
CO
H,S
Calibration Check (Performed a! Room Temperature)
Calibration Gas
Concentration
?IqC .Q99ylo
35a-�
20.9%
Win
Lot Number
","m "'mINS
1► 4SO
■
•
rr:■ ``a
s
i
l rr
Expiration
R-j+� r�--
Reading Accuracy*
2%
± 2%
± 2%
± 2%
:1: 2%
*Accuracy depends upon calibration range, 15%-FS range for CHa & CO2, 0-5%volume for Oi, 0%-FS for H2S, and 10%of reading forCO.
INSPECTOR'S MAINTENANCE NOTES
f F:I C, L 1 E 2M hlu 9 Ca1 roan 0! 1 k 2
CERTIFICATION
OF CALIBRATION a
No. 66916
Date Of Calibration: 11-Mar-2020 . Certificate Number: G50495I_9/38675
Issued•by: QED Enviranmerjta[ Systems Inc. • ~ `
Customer: ENVIRO EQUIPMENT INC
11180 DOWNS R❑ PINEVILLE, NC 28134
USA
Description: Landtec Gas Analyzer
Model: GEM5000
Serial Number: G504951
Accredited Results:
MaFhwm lrN&l
Certified Gas 96
Instrument Reading %
Uncertainty 96
5.0 -
4.9
0.42
15.0
15.0
0.66 .
50.0
49:5
1.03
Carbon Dioxide CO2 "
Certified Gas 9b -
Instru nt Readih %
-Uncertainty96
4.9
4.7
0.43
15.0
14.7
0.71
50.0
50.3
1.19
Oxygen 0Z
Certified Gas N
Instrument Reading 96
Uncertainty 96
21.0
21.0
0.25
Gas cylinders are traceable and -details can be provided if
requested. ,
CH4, CO2 readings recorded at: 32.2 °C/89.9 °F Baeometric Pressure: 0983 mbar/29.02"HL
02 readings recorded at: 21.8 °C/71.5 "F
MetHod of Test : The analyzer is calibrated in -a temperature controlled chamber using a series df reference
gases, in compliance with procedure 15P17.
The reported expanded uncertainty is based on a standard -u' certainty multiplied by wcoverg4e factor of k=2,
providing a level of confidence of approxjmately 95%. The uncertainty evaluation has been carried -out -in jrrcordance
with NIST requirements.
The calibration results published in this certificate were obtained using equipment capable of'producing results that are traceable through MST to the I nternat Iona I System of
Units ISIj. Certification only applles to results sown. This certificate may not be reproduced other than in tull, exceptwith the prior written approval of the TsyuIng laboratory.
Calibration lmtw[e: 107 IGC Instance: 107 Pagc I oft 1 LK15LNANIST--I.I
www.gede.nv.6om (8001 624-2026' info@gedenv.caam
QED Environmental Systems Inc. 2355 Bishop Circl'e West,.Dexter, M1 48130
CERTiFiCATION VQ E. D
OF CALIBRATION
No. 66916
Date Of Calibration: 11-Mar-2020 Certificate Number: G504951_9/3867-9
Issued by: QED Environmental Systems Inc.
Non Accredited results:
Pressure Transducers inches of water column
Transducer Certified (Low) Reading (Low) Certified (High) Reading (High) Accuracy
Static 0"
0.00"
40" 40.04" 2.0"
Differential 0"
0.00"
4" 4.01" 0.7"
Barometer mbar
Reference
Instrument Reading
0983 mbar 29.02 "Hg
0984 mbar 29.07 "H
As received gas check readings:
Methane CH4
Certified Gas 9b
Instrument Readin °%
5.0
.5.1
15.0
15.3
50.0
50.2
Carbon Dioxide CO2
Certified Gas 96
Instrument Reading9b
4.9
5.0
15.0
14.7
50.0
49.8
Qx en 02
Certified Gas %
Instrument Readin 96
21.0
21.6
As received Gas readings recorded at: 32.2 °C/89.9 7
As received Barometric Pressure recorded at: 21.9 T/71.5'F
Date of Issue., 12 Mar 2020 Approved By Signatory
Dan McCarty
Laboratory Inspection
i
The calibration results published in this certificate were obtained using equipment capable of producing results that are traceable through NIST to the International System of
Units [SI]. Certification only applies to results shown. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory.
CWibralian IIISUMCC: 107 1GC Instance: 107 Page 2 nr21 LP015LNANI5T-1.1
www.gedenv.com (800) 624-2026 info@gedenv.com
QED Environmental Systems Inc. 2355 Bishop Circle West, Dexter, MI 48130