Loading...
HomeMy WebLinkAbout4101_Guilford_HighPoint_Seaboard_MSWLF_Sept20LFG_FID1518981_20201222DocuSign Envelope ID: 5F918BFC-F78B-4922-8D58-CFDAFDOBF4AD DENR USE ONLY ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #: NC DENR I IEnvironmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Smith Gardner, Inc. Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Joan A. Smvth. PG Phone: (919) 828 - 0577 x221 E-mail: Joan@smithgardnerinc.com NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) High Point Riverdale Closed MSW Riverdale Drive, High Point, NC 41-01 .0500 September 16, 2020 Landfill Environmental Status: (Check all that apply) Initial/Background Monitoring 0 Detection Monitoring Assessment Monitoring Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells 0 Groundwater monitoring data from private water supply wells El Leachate monitoring data El water monitoring data Methane gas monitoring data Corrective action data (specify) Other(specify) Notification attached? e No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. FXI Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Joan A. Smyth, PG Senior Hydrogeologist (919) 828 - 0577 x221 Name (Print) Title (Area Code) Telephone Number L, 9/29/2020 Affix NC Licensed/ Professional Geologist Seal Date 14 N. Boylan Ave, Raleigh, NC 27603 Facility Representative Address F-1370 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 C AR aUEA ozo ` A. ltNUB DocuSign Envelope ID: 5F918BFC-F78B-4922-8D58-CFDAFDOBF4AD This page intentionally left blank. DocuSign Envelope ID: 5F918BFC-F78B-4922-8D58-CFDAFDOBF4AD NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: �gfig�h��C��lv�rl�l��f�14�1 Permit Number: 41-A1_01 Date of Sampling: 9/16/2020 NC Landfill Rule (.0500 or .1600): .0509500 Name and Position of Sample Collector: Michael J. Liebl - Staff Environmental Technician Type and Serial Number of Gas Meter: GEM 5000 Date and Time of Field Calibration: 9/16/2020 0953 Calibration Date of Gas Meter: 1/2020 Type of Field Calibration Gas (15115 or 35/50): 15/15 Expiration Date of Field Calibration Gas Canister: 12/2020 Pump Rate of Gas Meter: 0.5 LPM Ambient Air Temperature: 72 F Barometric Pressure: 29.32 in Hg General Weather Conditions: Sunny/Clear Instructions: Under "Location or LFG Well" identify the monitoring wells or describe the location for other tests (e.g., inside buildings). A drawing showing the location of test must be attached. Report methane readings in both % LEL and % methane by volume. A reading in percent methane by volume can be converted to % LEL as follows: % methane by volume = % LEL/20 LocaEDn or LFG V4 a ID Sample Tube Purge Time Time Pumped (s) Initial %LEL Stabilized °•oLEL %CFI4 by Volume %02 %1202 Notes H2 S ppm 1-1 >60s 1103 >60s 10 10 0.5 18.1 1.3 2 LFG 3 >60s 1057 >60s 0 0 0.0 11.3 7.4 2 LFG 4 >60s 1111 >60s 0 0 0.0 17.9 2.7 2 LFG 5 >60s 1125 >60s 0 0 0.0 13.5 4.1 2 LFG 6 >60s 1120 >60s 92 92 4.6 8.8 17.7 2 LFG 7 >60s 1204 >60s 950 950 47.5 3.7 19.6 3 7-1 >60s 1212 >60s 304 304 15.2 4.2 18.4 1 7-2 >60s 1208 >60s 2 2 0.1 19.3 1.1 1 7-3 >60s 1201 >60s 2 2 0.1 17.8 6.9 0 74 _ - - - _ _ - Inaccessible LFG 8 - - - - - - - Inaccessible LFG 8A >60s 1155 >60s 1156 1156 57.8 1.1 28.1 3 LFG 8B >60s 1156 >60s 488 488 24.4 11.3 16.5 3 8-1 >60s 1153 >60s 1146 1146 57.3 0.6 35.2 3 8-2 >60s 1151 >60s 1064 1064 53.2 0.2 40.1 3 8-3 >60s 1149 >60s 994 994 49.7 0.2 40.2 2 8-4 >60s 1137 >60s 988 988 49.4 0.6 37.0 2 8-5 >60s 1142 >60s 304 304 15.2 4.0 21.7 3 LFG 9 >60s 1140 >60s 822 822 41.1 3.3 29.7 3 9-1 >60s 1145 >60s 796 796 39.8 2.2 37.5 2 LFG 10 - - - - - - - Inaccessible Old Maint Bldg >60s 1128 >60s 0 0 0.0 20.1 0.1 3 Electrical Shop >60s 1130 >60s 0 0 0.0 20.0 0.1 2 If your facility has more gas monitoring locations than there is room on this form, please attach additional sheets listing the same information as contained on this form. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Staff Environmental Technician SIGNATURE TITLE DocuSign Envelope ID: 5F918BFC-F78B-4922-8D58-CFDAFDOBF4AD This page intentionally left blank. DocuSign Envelope ID: 5F918BFC-F78B-4922-8D58-CFDAFDOBF4AD f +� •! y LFG 5 LFG-3 ��9f$r ' LFG-4 + 5 O LFG Probes 300 150 0 300 Feet LFG-6 f , =-. 'rI`" rj;j� At' �." V # . 7-3 7-4 LFG-8 g_1 8-3 ° 8B 7.1 LFG-7 7-2 8A�• LFG-9 LFG-10 0 cn Z O J U In O za Z Q Z w � O m J a o a o O a p� = tU Z > 0 O O Q O L Z C V 2 O LL LIA J r