Loading...
HomeMy WebLinkAboutSDTF9807_INSP_20200710FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 1 of 2 UNIT TYPE: Lined MSWLF LCID YW Transfer Compost SLAS COUNTY: Wilson Closed MSWLF HHW White goods Incin T&P FIRM PERMIT NO.: SDTF-98-07 CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF X FILE TYPE: COMPLIANCE Date of Site Inspection: 07/10/2020 Date of Last Inspection: 07/12/2019 FACILITY NAME AND ADDRESS: Myrtle Creech Creech’s Septic Tank & Grease Trap Cleaning 8973 Kirby Road Kenly, NC 27542 GPS COORDINATES: N: 35.59458 E: -78.07656 FACILITY CONTACT INFORMATION: Name: Myrtle Creech Address: PO Box 460 – Lucama, NC 27851 Telephone: 252-239-0016 Email address: tcreech23@gmail.com PARTICIPANTS: Chester Cobb (DWM) and Myrtle Creech STATUS OF PERMIT: Active EXPIRES: 03/28/2019 (application received) PURPOSE OF SITE VISIT: Routine STATUS OF PAST NOTED VIOLATIONS: No violations noted on the previous inspection. OBSERVED VIOLATIONS: NONE The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 2 of 2 ADDITIONAL COMMENTS 1) This facility consists of one above ground metal tank with a capacity of 10,000 gallons for the storage of domestic and grease septage. 2) “No Trespassing” signage present along access roads to tank. 3) The access road to the detention facility was in good shape. 4) Tank accessible for inspection. No debris or vegetation blocking the tank from being inspected as per Rule 15A NCAC 13B .0838(i). 5) The 10,000-gallon metal tank appeared to be structurally sound. No leaks noticed. 6) Septage transfers to and from the facility appear to comply with the Septage Rules. No septage spills noticed. 7) No odor or vector issues noticed. 8) Setback distances appear to be ok. Please contact me if you have any questions or concerns regarding this inspection report. ________________________________________ Phone: (919) 707-8283 . Chester R. Cobb, Environmental Program Consultant Division of Waste Management, NCDEQ Regional Representative Sent on: X Email Hand delivery US Mail Certified No. [ _]