Loading...
HomeMy WebLinkAbout1203_Burke_JohnsRiver_MSWLF_Sept20LFG_FID1457182_20201007[ENR USE ONLY ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #. ' NC DENR Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): LaBella Associates (Joyce Engineering) Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Van Burbach Phone: (336) 323-0092 E-mail: Vburbach@labellapc.com NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) Johns River 2500 Marsh Trail Waste Management Facility Morganton, NC 12-03 .1600 September 1, 2020 C&D-over-MSW Landfill Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring ❑ Detection Monitoring Assessment Monitoring Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells XD Groundwater monitoring data from private water supply wells Leachate monitoring data El water monitoring data Methane gas monitoring data Corrective action data (specify) Other(specify) Notification attached? e No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. OX Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. G. Van Ness Burbach, Ph.D., P.G. Technical Consultant (336) 323-0092 Facility ieuresentativ,w Name (PrO4 _ Title _ (Area Code) Telephone Number 2211 W. Meadowview Rd., Ste. 101 Greensboro, NC 27407 Facility Representative Address C-07a2 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 Affix NC Licensed/ Professional Geologist Seal �NRO(jN . 4 _ LaBella Powered by oartnershiD. October 7, 2020 Mr. Miles Champion Burke County General Services Director/County Engineer P.O. Box 219 Morganton, NC 28680 RE: Burke County, Johns River Landfill Permit Number 12-03 Third Quarterly Landfill Gas Monitoring Report of 2020 Project No. 2192621 Phase: 04 Dear Mr. Champion: LaBella Associates (LaBella) is submitting the attached methane monitoring results for Johns River Landfill, Permit Number 12-03. The 2020 third quarter landfill gas monitoring event was performed on September 1, 2020. During this event, gas probes GP-1S, GP-1D, GP-2S, GP-21, GP-2D, GP-4, GP-5, GP-6, GP-7, and GP-8 were monitored in accordance with the facility's Landfill Gas Monitoring Plan. GP-3S and GP-3D were abandoned in February 2018 for construction of new landfill Phases 2A and 4. The facility buildings, including the scale house (GMP-1), the shop (GMP-2), the office GMP-3), the shed (GMP-4), the shooting range (GMP-13), and the Recycling Center (GMP-14) were also monitored on September 1, 2020, as were ambient air monitoring points GMP-5 through GMP-12. The locations of the gas probes and monitoring points are depicted in Drawing 1. The monitoring data for the gas probes and buildings are summarized in the attached Landfill Gas Monitoring Data Logs. Methane was detected above the lower explosive limit (LEL) in gas probes GP-2S, GP-21, GP-2D, and GP-4, and below the LEL in GP-5. Gas probes GP-2S, GP-21, and GP-2D are a nested set located in close proximity to waste in the old C&D-over-MSW landfill and are not considered boundary probes. GP-4 is located between the two landfills and is also not a boundary probe. No exceedances were recorded for any of the other probes, monitoring points, or structures. The methane detections and exceedances are summarized in Table 1 and Table 2, respectively. We have included a NCDEQ Environmental Monitoring Reporting Form (EMRF) and will forward a copy of this report to Jaclynne Drummond with the NCDEQ Solid Waste Section. A copy of this report should be maintained in the facility's records. The next quarterly monitoring event is tentatively scheduled for November -December 2020. If we can provide any additional information please do not hesitate to call me at (336) 323-0092. 2211 W. Meadowview Road #1o1 i Greensboro. NC 27407 P (336) 323-0092 www.LabeLLapc.com 0=1 Respectfully submitted, LaBella Associates Van Burbach, PhD. PG Sr. Technical Consultant Attachments: Environmental Monitoring Reporting Form (EMRF) Tables 1 & 2 Landfill Gas Monitoring Logs Drawing 1- Site Map with Gas Monitoring Locations cc: Jaclynne Drummond, NCDEQ Table 1: Methane Detections - Sept. 1, 2020 LFG Probe CH4 (%Vol.) CH4 (%LEL) GP-2 S 57.8 1156 GP-2 1 57.8 1156 GP-2 D 57.8 1156 GP-4 58.0 1160 G P-5 2.6 52 Table 2: Methane Exceedances - Sept. 1, 2020 LFG CH4 CH4 Probe (%Vol.) (%LEL) GP-2 S 57.8 1156 GP-2 1 57.8 1156 GP-2 D 57.8 1156 GP-4 58.0 1160 Notes: CH4 = Methane. %Vol. = Concentration in pecent-by-volume. %LEL = Concentration as a percent of the LEL. LEL = Lower Explosive Limit = 5%Vol for Methane. S = Shallow Screen. I = Intermediate Screen. D = Deep Screen. BOLD = Exceedance. Burke Co., Johns River Landfill Permit # 12-03 Labella Associates NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: Thus form and any information attached to it are 'Public Records" as defined to NC General Statute 132-1. As such. these docionents are avadable for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: �4trKei — RyeY— Permit Number: 12 — 03 Sampling Date: D9.10 I I � NC Landfill Rule (.0500 or.1600): - (a 00 Sample Collector Name& Position: R • rYltsub•ed_— EAv. 1i44 uivvc ttomt Gas Meter Type & Serial Number: Ca Err 5DD() (VN : 6SUSi4q Gas Meter Calibration Date: 0�tavgo Field Calibration Date & Time: CAI'D 1 I Z020 11 IS aP E gu, Field Calibration Gas Type (15'15 35/5 5b/•te+yt 3Si CV-7-FieldCalibration Gas Canister Expiration Date: IQIg oyZ Gas Meter Pump Rate: 300 Mt-hf rl nF cto"d Ambient Air Temperature: Barometric Pressure (in. or mm Hg): -�8 -$2 Weather Conditions: Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CHa by volume. Convert % CH4 (by vohtme) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring mciv be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and or Facility LFG monitoring plan. Location or LFG Well [D Sample Tube Puree Time of Day Time Pumped um P (sec) Initial % LEL Stabilized °u LEL °u CHd (volume) o /0 02 (volume) Q. COZ (volume) "o H2S* (volume) NOTES Gq-1& i51$ 6o 0 1LI•0 5•-+ G V-1D i&iq D 13, q I & -. C-I -Zs 8 Is43 v O15'(p 0$ 40.4 faP-22 15 bu 0 115,6 0 40.5 &P-',D 1 1945 lP D 0 I I sfa 0 40. 6 CAP- 15'35 60 1 p 0.3 40.5 cle-5 IS52 (p t) V d• 14 • (0 4. S &?-0 1914 (OD V 1 0.9 13.2 8 1&02 b1) 0 0 (Y•3 GP-S i SSB G 0 fsMp-isr e i&D (00 raw-Z Re b3 60 D A o • 1 VOTE tf needed, attach additional data forms to rnchide additional LFG monitoring data locations for the facility V I lo,, LF N F I �. Methane: >1.25% by volume (inside structures) AND >5%, by volume (at facility boundary) Hydrogen Sulfide: >1". by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. "u _ Env. 6e)d Cow+ar t SIG, ATURE TITLE Revised — March 6, 2017 PA.I oF*3 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This farm and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and esantination by any person upon request (NC General Statute 132-6). Facility Name: bArK& 'Johns 14ev- Permit Number: Sampling Date: 091 Q1 W70 NC Landfill Rule (.0500 or.1600): _ I2 o-3 rolo Sample Collector Name & Position: I.I 6 — Milt • Eitld cp nsida r r Gas Meter Type & Serial Number: A rM POO ( SIN : 6T'O.5-140 Gas Meter Calibration Date: 041 Z07-0 Field Calibration Date & Time: o f ID ( 1"7,D P i / is; p t 16LIwye. Field Calibration Gas Type (15115 0 35/5/ :.S�/a+4, 3- ` 91 0-2 Field Calibration Gas Canister Expiration Date: r2 ozz Gas Meter Pump Rate: 300 m1'/ 1'Y11 Yt Ambient Air Temperature: 80 T Barometric Pressure (in. or min Hg): aA •$2Weather Conditions: Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and or Facility LFG monitoring plan. E�Pu`mped • • %, • © I 1 r, M- ACE i e M� - �®P. r �0 mm-mmm== /� ii 1 MME �IFEMM K 0 rim MEE mo MIN /9 M "If ®.S W`. ' I M r , / / k - /,# = Jim■■ ;VOTE; if needed, attach additional data forms to include additional LFG nionitoriitg data locatiotis for the facility. Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundan) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. SIdNXTURE TITLE Revised — March 6, 2017 Poi - a of NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records "as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon regitest NC General Statute 132-6), Facility Name: RUVKe, —JL*ns Rtv•etr Permit Number: (2-03 Sampling Date: QqIDI`� NC Landfill Rule (.0500 or.1600): p (*DO Sample Collector Name & Position: R•mesubed —Env Bet4 C.owlawfa.nt Gas Meter Type & Serial Number: G EM 5OOD CA: 6500 f ) —Gas Meter Calibration Date: lDg1U %0 Field Calibration Date & Time: �%°I 101 to zp %Qi /1 IS �lq- Field Calibration Gas Type (15115 C35/5))_Jjp`/ (Ffyt 3�'%lr7�Field Calibration Gas Canister Expiration Date: ZZ Gas Meter Pump Rate: 300 f'/"V1 Ambient Air Temperature: Z V' P Barometric Pressure (in. or mm Hg)tX.32, Weather Conditions: ripwi Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CHl (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. "Hydrogen Sulfide (112S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and or Facility LFG monitoring plan. Location or LFG Well ID S ample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized % LEL % CHa (volume) % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES -� yc1 i6a� 60 20.o n. I VOTE If needed. attach additional data forms to include additional LFG monitoring data locations for the facility. V I ION LF x F I s. Methane: >1.2:i% by volume (inside structures) AND >51/4 by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported'and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. ,p lr>'i^Env f3A Cb1ggj+441t SIGNATURE TITLE Revised — March 6, 2017 P0. 3 of 3 _ o� 10 _ a 0 0 a 7.x. 3\ W �� GMP-1� DJepo22. v/� o-20 GIIAIP KW $ a 3-0B-10 P�AC1A Pw x a a o // s ze 000ao HASE /� PHASE 2 PHASE 4 4.] AC s / \ H E Y6 \ SAC /4.0 AC /NLE Lu / �PZ-38+PZ-30Y PZ-22S D/�, 2zz S p0� a GP 1 AB GP-2 `� GP-2 T P NLE GP-3 P SE 8 i/ V 3 a 4.2AC PZ-35 / / / / / / l� W PZ-'16D G oPz GP-< GV-02 , - �PZ-23 4 0 Ac Pz GV-03 E PZ-1q 8�z-8D !,, _ _ - / < z �rGP� PHASE 6 / / �J Y GMP-5 ( \ GV-04� i / Pz-12 �.9 AC A _ / Z O0-1 -O5� PHASE 7, \ �� LLI 0-, O GV 4.2 AC > GMP 12 PZULu . LL GV 06 L Pz -27 Z z GV-07 — �13 .� �� �♦ nPZ-18/ I �/ i �� LE W z !P 6 P3 iso� —A� Q SSZ O p GV-07 GAS VENT W WILL U' >`� J GMP-14 GAS MONITORING POINT E m �Oti %I �, A ___ _ �•1 - - A �V GP-2 Z is,\ \ — GMP 0 \ GAS PROBE _ GMP-7 MW-30 MONITORING WELL � J 10 FOOT CONTOUR LINE PROJECT NO. I/ j _ / —8-�-h �1 —• fNW-1sU — � /� / \ ( ( _M°°=sue 2 FOOT CONTOUR 277.1002.11 \ {}' GMP-7A — — — — — / _ _ PROPERTY BOUNDARY SCALE AS SHOWN _ ... 0 MW-18 0 MW-19 GRAPHIC SCALE DRAWING NO. / l AB = ABANDONED 0 150 300 soo NLE=LONGER EXISTING (P LFG-01 (PRESUMED DESTROYED) (FEET)