Loading...
HomeMy WebLinkAbout6301_MooreCounty_MSWLF_CDLF_Sept2020LFG_FID1452876_20200925PENR USE ONLY: I I LJPaper Report LlElectronic Data - Email CD (data loaded: Yes / No Doc/Event #: NC DENR I I Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: • Prepare one form for each individually monitored unit. • Please type or print legibly. • Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). • Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. • Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). • Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): S&ME, Inc. (on behalf of Moore County) Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Edmund Q.B. Henriques E-mail: ehenriques@smeinc.com Phone: 336-288-7180 NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) Moore County Landfill 456 Turning Leaf Way, Aberdeen, NC 63-01 .0500 September 15, 2020 Environmental Status: (Check all that apply) Initial/Background Monitoring Fx� Detection Monitoring Assessment Monitoring Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells x❑ Groundwater monitoring data from private water supply wells U Leachate monitoring data ❑ Surface water monitoring data Methane gas monitoring data Corrective action data (specify) Other(specify) Notification attached? e No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. 7x Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Edmund Q.B. Henriques, PG Senior Geologist 336-312-3330 Facility Representative Name (Print) Title (Area Code) Telephone Number .6 9/24/30 Affix NC Lice Signature t Date 8646 W. Market Street, Suite 105, Greensboro NC 27409 Facility Representative Address F-0176 NC PE Firm License Number (if applicable effective May 1, 2009) o—„-4 aionnc) ff�,/ P(!fm ri eologist Seal 40 n .. u^ a 0�1 �`• ,� `ter(• ® E"Y b®��f!" $4aseainota NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Moore County Landfill Permit Number: 63-01 Sampling Date: September 15, 2020 NC Landfill Rule (.0500 or.1600): 0.0500 Sample Collector Name & Position: Gary Simcox / Senior Technician, S&ME, Inc. Gas Meter Type & Serial Number: GEM 5000 P I U S Field Calibration Date & Time: 9/10/20 Gas Meter Calibration Date: 7/30/2020 Field Calibration Gas Type (15115 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 10/2023 Gas Meter Pump Rate: 680 cc/min Ambient Air Temperature: 75 Barometric Pressure (in. or mmHg): 29.82 Weather Conditions: Sunny Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID S ample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized % LEL % CH4 volume (volume) % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES GP-9 60 0945 180 0 0 0.1 21.1 0.1 0 1-inch dia. well GP1 OR 60 1035 240 0 0 0.0 20.8 0.2 0 2-inch dia. well GP-11 60 1020 180 0 0 0.0 10.8 9.7 0 1-inch dia. well GP-12 60 150090 0 0 0.0 20.6 0.6 0 1-inch dia. well GP-13R 60 1110 180 0 0 0.0 20.2 1.3 0 2-inch dia. well GP-14R 60 1420 140 0 0 0.0 19.9 0.2 0 2-inch dia. well GP-15R 60 1445 140 0 0 0.0 20.9 0.3 0 2-inch dia. well GP-16 60 1155 180 0 0 0.0 20.6 0.6 0 1-inch dia. well GP-17 60 1155 180 0 0 0.0 3.9 18.0 0 2-inch dia. well G P-18 60 1220 180 >5 >5 22.5 10.4 15.1 O 2-inch well formerly MW-15 GP-19 60 1140 180 0 0 0.0 20.9 0.2 0 2-inch dia. well NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. q/a Senior Geologist / S&ME, Inc. SIGNATURE TITLE Revised - March 6, 2017 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Moore County Landfill Permit Number: 63-01 Sampling Date: September 15, 2020 NC Landfill Rule (.0500 or.1600): 0.0500 Sample Collector Name & Position: Gary Simcox / Senior Technician, S&ME, Inc. Gas Meter Type & Serial Number: GEM 5000 Plus Field Calibration Date & Time: 9/10/20 Gas Meter Calibration Date: 7/30/2020 Field Calibration Gas Type (15/15 or 35150): 15/15 Field Calibration Gas Canister Expiration Date: 10/2023 Gas Meter Pump Rate: 680 cc/min Ambient Air Temperature: 75 Barometric Pressure (in. or mm Hg): 29.82 Weather Conditions: Sunny Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID S ample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized % LEL % CH4 volume � � % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES MW-6 60 1140 180 0 0 0.0 21.1 2� 0.0 0.0 2-inch monitoring well upslope of GP-19 Blake Residence�rawlspace 60 1520 60 0 0 0.0 /1� 22.0 0.0 0.0 off -site structure Gv-33(east vent) 60 120560 >5 >5 25.0 0.6 30.0 2.0 gas cut-off trench vent Gv-34 (west vent) 60 121060 >5 >5 22.1 1.3 28.4 0.0 gas cut-off trench vent Scale House 60 1545 120 0 0 0.1 22.3 0.0 0.0 on -site structure Maintenance shop 60 144590 0 0 0.0 21.5 0.0 0.0 on -site structure Transfer Station 60 152060 0 0 0.0 22.1 0.0 0.0 on -site structure NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. ia, oz• Senior Geologist / S&ME, Inc. SIGNATURE TITLE Revised - March 6, 2017 Table 1 Summary of 2020 Methane Gas Readings Moore County Landfill (Permit 63-01) Moore County, North Carolina S&ME Project No. 4358-20-043A Location Scale -house Maintenance Transfer Blake GP-9 GP-10 GP-10R GP-11 GP-12 GP-13 GP-13R GP-14 GP-14R GP-15 GP-15R GP-16 GP-17 MW-6 MW-19 MW-15/ Shop Station Crawlspace GP-18 Monitoring Point Type ONSS NSS ONSS OFFSS PB PB PBJ$B JIB PB JjPB PB JJ PB PB 10 PB PB J PB PB PB Date r r r r•. r r•. r r'. r r•. r r'.�� r r•. r r'. r r•. r r'. r �•. r r'. r �•. r r'. r �•. r r'.��� r- r r r• r � r r•. r r'. r r•.�� r r'. r r•. r r'.� r r'.� r r'.� r r'. r r•. r r'. r r•. � r'.� Notes: Monitoring Point Types: PB = Property Boundary, ONSS = On Site Structure, OFFSS = Off -site Structure all measurements recorded in percent methane by volume Lower explosive limit of methane gas: 5% Upper explosive limit of methane gas: 15% All data recorded prior to 9/15/20 supplied by Golder --Indicates no measurement recorded/obtained. Yellow highlight cells and values in bold print indicate methane percent by volume greater than or equal to 5% at property boundary monitoring point T:\Projects\2020\ENV\435& 43A Moore C.-ty Routine LFG&WQ Monitoring\Task 02- Quarterly Landfill Gas\LFG Readings T.ble.rlsx ENVI RO-EQU I P M ENT, INC., LANDTEC GEM 5000 Plus CALIBRATION DATA SHEET Serial Number GS(7)410( 5 Date (Z(:�/I0Inspector Tinte/Date Battery Level Plo Memory Cleared 1 Pump Faults Gas Alarms: CHa = 100.0% COz = 100.0% OZ = 22.0% DEN Zero Transducers Pump Flow Rate ����yr+tin Vacuum Tested To 80" HZOCkOG --j Calibration Gas Pure N. High CH, High COZ Low CH - Low CO, Low O, High O, CO H2S Calibration Check (Performed at Room Temperature) Calibration Gas Concentration �o 35�1. 4° 1,. 20.9% E5(Zf?pr.N Ill wr.^ Lot Number 112'�3�9 IZ m2 IZGm'L� I l5�-�b2 1 I S�-3b2 It 0 \q) N/A 133b�8�- 1336�a� Expiration Reading Accuracy* IQ`O*% 49.9n. 35. m- 15.0'7. 15. m"- n. 211nn. 9 �1. -Accuracy depends upon calibration range; 15%FS range for CH4 & COi, 0.5% volume for (i, 0%-FS for HiS, and 10%,of reading for CO. INSPECTOR'S MAINTENANCE NOTES uai ceH'oo° N,,, U Fo, , mn z P CERTIFICATION' OF CALIARATION GPw6. No. 66916 Date Of Calibration: 30-Jul-2020 Issued by:.QED Envjionmental Systems Inc.-, Non Accredited results: Certificate Number: G504615_9/39725 Pressure Transducers inches of water column Transducer Certified (Low) Reading (Low) Certified (High) Reading (High) Accuracy Static 0.. 01. 40" 40.05" 2.0" Differential 0" 0111 411 1 3.99" 1 0.7" As received gas check readings: .Methane CH4 Certified Gas °6 Instrument Reading % 5 ro 5.4' 15.0 15.3 50.0 , . 49.9 Carbon Dioxide [CO Certified Gas % Instrument Reading % 4.9 5.2 15.0 15.1 50.0 49.2 Oxygen 02 Certified Gas % Instrument Reading % ' 20.9 20.9 • L. As received Gas readings recorded at: 32.4 °C/90.4'F As received Barometric Pressure recorded at: 21.8'C/71.27 As received gas check readings are only recorded if the instrument is Where the instrument is received damaged no reading can be Men. r Date of Issue : 31 Jul 2020 Approved By Signatory in a w g condition. Kyle Racine - '.LabAtory Inspection The calibration results published in this certificate were obtained using equipment capable of producing results that are traceable through NIST to the International System of Units (SI). Certification only applies to results shown. This certificate may not be reproduced other than in full, except withthe prior written approval of the Issuing laboratory. Calib ixion Instance: 107 10C lnstuc, C 107 P,B 2 of 21 LP015LNANIST-I.1 www.ge.denv.com (800) 624-2026 info@ge.denv.com QED Environmental Systems Inc..2355 Bisho p Circle West, Dexter, MI 48130 CERTIFICATION OF CALIBRATION, Nor 66916 Date Of 0,[ibration: 3Q=Jul-202O Issued by:,QED Environmental Systems Inc. customer: Enviro Equipment Inc 11180 Downs Rd Pineville, NC 28134 USA Description: - Landtec Gas Analyzer Model: GEM5DD0 Serial Number: G504615 Accredited Results: f�Certfled G .05.0 0.0 VQnD Certificate Number: G504�15_9MTV;: 0.66 1" Certified Gas Ufa - "' " 0.43 4.9 4.6 145 0.71 . 15.0 t 1 q Gas cylioders are traceable and details can be provided if s . requested..: Barometric Pressure: CH4, CO2 readings recorded at: 32.4 °C/90.4 0980"Hg/28.93 "Hg 02 readings recorded at: 21.8 °C/71.2 °F . Method of Test,&he analyzer is calibrated in a temperature zontrolled chamber using a series of reference �.. gases, incorfiplia ce with procedure ISP17: - - - - The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. The uncertainty evaluation has been carried out in accordance with NIST requirements. _ of The calibration results published In this certificate were obtained using equipment capable of producing results that are traceable through NIST to the International System ry Units (SI). Certification only applies to results shown. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory. ` - - - Page l of 21 LMISLNANIST-LI Calibration Nstancc: 107 ICc Instance: 107 f. - www.gedenv.com -(80p)-624-2026 info@gedenv.com QED Environmental Systems Inc. 2355'Bi>hop Circle West, Dexter, MI 48130 000 ❑£xsE V£Gi:T877GN 000 000 00 nNNse vscernnoN 0 DENSE V•EGETaTrON n�nsE vEGErnzlv6 _ 1EN58 VEGEfAFEON � I t d DENSE YEGE[AAT30N I �J7t7!' Z a PSNU Y-SGELATIaV u OP.Ns6 VEGfti•ATTPN r DENSE VEGETATION _— £ENJ£ VEGETA•I•I0N - -- QENSE VEGETATION DENSE V8•rETp.4lpti DENn VEC6TAT[ON GP-17 r 7rAnoN woo — — �d ° OV J 1p 4 - -- y�;GP-19 DENSE VBG[TAMN U.B. YE1GC.rATION 10 ��'� 0MW-6 GP-1 "$a 'ad ° fo QENSE VEGErATT➢ 00000 00 "'r "� ❑ ° ° o I woo* PEN: I: DIME VEGETATION P-15R ' cp ' ACTIVE ' C&D °q0❑ 00 LANDFILL ,� q go40 DENSE YEUTATION ` 000 3 DENSE VEGETATION - r]tN Vie: V4:G L1A'1..N ' aeNsE VEGETATION yT.N9& vERPTRTIDN �1 •.. _.. A -13R o �. O ~ ! .' ➢£K9E V rATION ' NAINTENA aENSE VEGETATION / BOIL 1f yY� pENSE vBGET�IIM, PENS£ VEGETAT[UH �r• l DEN MAINTENANCE SHOP,w.,,� -�T �- f7 P-18 - - - - - ISNII YEIE'I':.:.'ON - �. MOM �111 1111111111_ £ENS£ Y$GSTATTi1N SITE LOCATION MAP NOT TO SCALE Qxnsis V£cExeTlG 1� CAP-12 \ DENSE VEGETATION DEMM YNSE VECETAT N E= RESIDENCE (CRAWL SPACE MONITORED) 1 � lmoowV::L 1EGY "JON LL.'r-I_ ': EGE rz'�i•]': —_ _ 11ENN$. YECETATfON - - -- - DENSE VEGETATION - z - GP-11 NSE DENWEIGEfATI TRANSFER STATION OFFICEjilo DENSE VEGETATIUN j I a MNSIZ VENWATTPN .. - r {.• p QENBE V$OLTA7'1uH � un-FIC VN III� f,� ' II G 0 ASN38 VEGETATON / ' • ' QENSE VEGETATION _/ — ..............'.�. _ .. � • D8E36 vF,GETATlG9 ❑ENSE VECE7A'YIDN 7 GNvss VEM7A,770N VEG£riTION III {I h' I :NSE VEGETATION I` j ➢ :P _ _ - - -- � I vfx • rrnn DENSE VLMETATIGE 14 5 1 .. QEN9E YBGEf ' DN E VEG87'ATTDN DENSE VEC£TATIOA - �- N. -� P- Z (iPNs& VEGETATION .--......ION j III, SE VEGETATION QBNSE VEGEPA77 ,� R u SCALEHOUSE LEGEND — STREAM, POND, AND WETLAND LIMITS EXISTING 10 FT GROUND SURFACE CONTOUR EXISTING 2 FT GROUND SURFACE CONTOUR i PROPERTY LINE JJJ. JJJJJJJ. JJJJJJJ. JJJJJJJ. JJJ. APPROXIMATE LIMITS OF WASTE EXISTING ROAD O MW-1 MONITORING WELL AND IDENTIFICATION &GP-9 METHANE PROBE AND IDENTIFICATION AGP-10R METHANE PROBE AND IDENTIFICATION (INSTALLED JUNE 2020) I� LANDFILL GAS TRENCH VENTS AND IDENTIFICATION PASSIVE LANDFILL GAS VENTS METHANE PROBE ABANDONED (JUNE 2020 OR AUGUST 2020) NOTES 1. TOPOGRAPHIC CONTOUR INTERVAL = 2 FEET 2. PROPERTY BOUNDARY SURVEY BY JAMES L. WRIGHT DATED NOVEMBER 1984. ITS LOCATION IS RELATIVE TO TOPOGRAPHY APPROXIMATE BY HDR ENGINEERING, INC. 3. EXISTING TOPOGRAPHY WITHIN ACTIVE AND PROPOSED LANDFILL PROVIDED BY MATTHEWS LAND SURVEYING & MAPPING, PLLC DATED APRIL 17, 2015 AND JUNE 2018. 4. MONITORING WELLS MIN-6 THROUGH MW-16 SURVEYED APRIL 1995, SEPTEMBER 1996, AND APRIL 2003 BY HDR ENGINEERING INC.! ED BUCKNER RLS APRIL 17, 2015. 5. THE LOCATIONS OF LANDFILL GAS TRENCH VENTS ARE APPROXIMATE. 6. NOTE GP-18 IS FORMER GROUNDWATER MONITORING WELL MW-15 (AS DETAILED IN THE LANDFILL GAS MONITORING PLAN (GOLDER 2019) +' r SCALE FEET C - = CLIENT PROJECT c MOORE COUNTY PUBLIC WORKS MOORE COUNTY LANDFILL (PERMIT #63-01 ) PO BOX 1927 456 TURNING LEAF WAY 4 CARTHAGE, NORTH CAROLINA ABERDEEN, NORTH CAROLINA " - •r. CONSULTANT _ PPC�C YYYY-MM-DD 2020-08-17 TITLE 2399 LANDFILL GAS MONITORING WELLS ti PREPARED BSD WELL INSTALLATION AND ABANDONMENT REPORT `^ - ,- GOLDER DESIGN BSD REVIEW RPK PROJECT No- PHASE Rev. DRAWING GOLDER ASSOCIATES INC, INC. APPROVED RPK 19133605 002 Q 0