Loading...
HomeMy WebLinkAboutNCS01490_INSP_20190712FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 1 of 3 UNIT TYPE: Lined MSWLF LCID YW Transfer Compost SLAS COUNTY: Wilson Closed MSWLF HHW White goods Incin T&P FIRM X PERMIT NO.: NCS-01490 CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF FILE TYPE: COMPLIANCE Date of Site Inspection: 07/12/2019 Date of Last Inspection: . FACILITY NAME AND ADDRESS: Mr. William Terrell Pickett III Walston Mechanical Inc. Septic Tank Cleaning 1711 Roxbury Drive Wilson, NC 27893 GPS COORDINATES: N: NA E: NA FACILITY CONTACT INFORMATION: Name: William Terrell Pickett III Address: PO Box 571 – Wilson, NC 27894 Telephone: 252-281-1538 Email address: walstonmechanical@yahoo.com PARTICIPANTS: Chester Cobb (DWM) and William Pickett STATUS OF PERMIT: Pending EXPIRES: PURPOSE OF SITE VISIT: Pre-operational STATUS OF PAST NOTED VIOLATIONS: NA OBSERVED VIOLATIONS: NONE The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 2 of 3 ADDITIONAL COMMENTS TRUCK LICENSE PLATE # VIN # TANK CAPACITY (gal) JP-9560 1HTMMAAL1BH316566 1,800 1) Inspected pump truck listed above. The firm name, town name, phone number, and firm permit number was on both sides of the truck. The letters were three (3) inches in height or greater except for the town name. Mr. Pickett changed the lettering for the town name to meet the 3-inch letter height requirement and emailed pictures to me on 07/15/2019. See pictures below. The lettering was distinguishable and not blocked from view. The lettering meets the requirements of 15A NCAC 13B .0835(b). 2) The tank is made of steel and affixed to the frame of the truck as per 15A NCAC 13B .0835(a)(1). 3) The valves appeared to be in working order and closed as per 15A NCAC 13B .0835(a)(2). Caps present on the ports. 4) The access ports had lids in good repair and were sealed as per 15A NCAC 13B .0835(a)(3). 5) No leaks noticed as per 15A NCAC 13B .0835(a). 0BPicture emailed by Mr. Pickett on 07/15/2019 showing that the letters for the town name had been changed to meet the 3-inch height requirement. 1BPicture emailed by Mr. Pickett on 07/15/2019. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 3 of 3 Please contact me if you have any questions or concerns regarding this inspection report. ____________________________________________ Phone: (919) 707-8283 . Chester R. Cobb, Environmental Program Consultant Division of Waste Management, NCDEQ Regional Representative Sent on: Email Hand delivery US Mail Certified No. [ _]