HomeMy WebLinkAbout8003_Rowan_MSWLF_CDLF_May2020LFG_FID1406302_20200515GOLDER
May 12, 2020
Ms. Jaclynne Drummond, Compliance Hydrogeologist
North Carolina Department of Environmental Quality
Division of Waste Management - Solid Waste Section
2090 US Highway 70
Swannanoa, North Carolina 28778
(828) 296-4706
Project No. 19123756.200
RE: METHANE MONITORING RESULTS — SECOND QUARTERLY EVENT — MAY 2020
ROWAN COUNTY LANDFILL, PERMIT NO. 80-03
ROWAN COUNTY, NORTH CAROLINA
Dear Jackie,
Attached are the results from the May 11, 2020, quarterly methane monitoring event conducted at the above -
referenced facility. No methane gas was detected in the facility structures during this monitoring event.
Permanent explosive gas monitoring devices are located in the scale -house and maintenance building. Methane
gas was not detected in compliance monitoring points at concentrations above the lower explosive limit (LEL)
during the second quarterly methane monitoring event.
The next monitoring event is tentatively scheduled for September 2020. If you have any questions or concerns,
please contact us at 336 852-4903.
Sincerely,
Golder As ciates NC, Inc.
Nicolas Tejeda-Torres Rachel P. Kirkman, P.G.
Geologist Associate & Senior Consultant
NTT/RPK/ntt:
Golder Associates NC, Inc.
5B Oak Branch Drive Greensboro, North Carolina, USA 27407 T: +t 336 852-4903 +t 336 852-4904
Golder and the G logo are trademarks of Golder Associates Corporation golder.com
Ms. Jaclynne Drummond, Compliance Hydrogeologist
North Carolina Department of Environmental Quality
CC: Caleb Sinclair, Environmental Management Director, Rowan County
Department of Environmental Management, 1102 N Long Street
Extension, East Spencer, NC 28039
Jeff Boyd, Landfill Supervisor, Rowan County Department of Environmental
Management, 789 Campbell Road, Woodleaf, NC 27054
Mike Plummer, PE, HDR, 440 S. Church Street, 10th Floor, Charlotte, NC
28202, mplummer@hdrinc.com (electronic only)
Attachments: Boundary Gas Probe Monitoring Log — May 11, 2020
Methane Monitoring Location Map
Calibration Certificate
Environmental Monitoring Form
g:\projects\rowan\19123756(2020)\phase 200 methane reports\200 dely\200 drafts issued\2nd quaterly methane 2020\05-11-2020 methane monitoring
report.docx
Project No. 19123756.200
May 12, 2020
GOLDER
NC Division of Waste Management - Solid Waste Section
Landfill Gas Monitoring Data Form
Notice: This farni and any it formation attached to it are "Public Records"as defined in NC General Stat:ae 132-1. As such. these documents are
available for inspection and exaniiiiation by any person upon request (dC General Statute 132-6).
Facility Name: Rowan County Landfill
Sampling Date: 05/1 1 /2020
Sample Collector Name & Position:
ermitNumber: 80-03
Landfill Rule (.0500 or. 1600):
Nicolas Tejeda-Torres
.1600 and .0500
Gas Meter Type & Serial Number: GEM 2000 Plus Gas Meter Calibration Date: 05/06/2020
Field Calibration Date & Time: 05/1 1 /2020 1 3.27
Field Calibration Gas Type (15115 or35/50): 1 5/1 5
Gas Meter Pump Rate: 300 cc/min
ield Calibration Gas Canister Expiration Date: 11 /09/2020
Ambient Air Temperature: 61 � F Barometric Pressure (in. or minHg): 29.01 Weather Conditions: Partly Cloudy, winds NW 18mph
Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office).
Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume.
Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL.
*Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See
individual permit conditions and�or Facility LFG monitoring plan.
Location or
LFG Well ID
Sample
Tube
Purge
Time of
Day
Time
Primped
(sec)
"Initial
% LEL
Stabilized
%LEL
% CH4
(volume)
% 02
(volume)
% CO2
(volume)
% H2S*
(volume)
NOTES
MMW-1
13:56
90
0
0
0.0
18.1
3.4
0.0
MMW-2A
14:07
90
0
0
0.0
20.3
0.5
0.0
MMW-3
14:11
90
0
0
0.0
19.7
1.7
0.0
MMW-4
14:16
90
0
0
0.0
11.2
8.7
0.0
MMW-5A
14:20
90
0
0
0.0
14.9
3.9
0.0
MMW-6A
14:24
90
0
0
0.0
14.7
3.1
0.0
MMW-7
14:32
90
0
0
0.0
17.9
3.8
0.0
MMW-CD
13:50
90
0
0
0.0
20.1
0.6
0.0
Maintenance Building
13:37
300
0
0
0.0
21.0
0.0
0.0
Scalehouse
13:31
300
0
0
0.0
21.0
0.0
0.0
MMW-2(NotCompliance)
14:00
90
0
0
0.0
20.2
1.5
0.0
MMW-5(NotCompliance)
14:39
1 90
0
0
0.0
20.1
0.5
0.0
NOTE: /f needed. attach additional data fornis to include additional LFG monitoring data locations for the facility.
AC11-I01, LEN ELS: Methane: >1.25% by volume (inside structures) AND >S% by volume (at facility boundary)
Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary)
Certification
To the best of my ledge, the information reported and statements made on this data submittal and attachments
are true and c r . I am aware th re are significant penalties for making any false statement, representation,
or certific ro ncluding the po rb' ty of 4.1yne and imprisonment.
Geologist
TURE
TITLE
Revised - March 6, 2017
NC Division of Waste Management - Solid Waste Section
Landfill Gas Monitoring Data Form
Notice: This form and any information attached to it are 'Public Records "as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Facility Name: Rowan County Landfill Permit Number. 80-03
Sampling Date: 05/11 /2020
Sample Collector Name & Position:
Landfill Rule (.0500 or .1600):
Nicolas Tejeda-Torres
Gas Meter Type & Serial Number: G E M 2000 Plus
Field Calibration Date & Time: 05/1 1 /2020 13:27
.1600 and .0500
Gas Meter Calibration Date: 05/06/2020
Field Calibration Gas Type (15115 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 11 /09/2020
Gas Meter Pump Rate:
300 cc/min
61 OF 29.01 Partly Cloudy, winds NW 18mph
Ambient Air Temperature: Barometric Pressure (in. or min Hg): Weather Conditions:
Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office).
Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume.
Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL.
*Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See
individual permit conditions and/or Facility LFG monitoring plan.
Location or
LFG Well ID
Sample
Tube
Purge
Time of
Day
Time
Pumped
p
(sec)
Initial
%LEL
Stabilized
%LEL
% CH4
(volume)
volume
0
/0 02
(volume)
0
/o CO2
(volume)
0
/o H2S
(volume)
NOTES
MMW6(Not Conpliance)
14:26
90
0
0
2.4
16.2
3.3
0.0
MMW-B(Nol Compliance)
13:44
90
62.0
62.0
1.7
10.4
11.2
0.0
NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility.
ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary)
Hydrogen Sulfide: >I % by volume (inside structures) AND >4% by volume (at facility boundary)
Certification
To the best o knowledge, the inf ation reported and statements made on this data submittal and attachments
are true d rrect. I am aware a ere are significant penalties for making any false statement, representation,
or certification including the ssi ity of a fine an ' risonment.
Geologist
AT TITLE
Revised — March 6, 2017
OLD
EXISTING LANDFILL
SEDIMENT ENTRANCE
BASIN
i
,i, MMW-5A�
_... I /_PHASE I
WLA DFLL _
Dill 0
EXISTING
SEDIMEN
BASIN
M 48�
i �,{L}'�"�'
♦
PHASE
MOW LA DFLL
o
1
o
I
PHASE 0
MOW LA DFLL ,
MW-200 ,
684.80 I o o
MMW-70- I ♦,I
♦♦ o _
♦
♦� , lo
o
♦�,
I I'
M661
1 _ ♦ - 61
1s02�♦_ 4*
✓ ,�♦ PHASE N AFEA "\\' !
1 �!
611.400 ! ;
I
! FUTURE
MSW LANDFILL
1 _ - I (PHASES IV &V)
L--
41
1 _
N
SCALE
HOUSE
MW-16
706x42 �.
�c TAW -CD
______— W17
.\ - - 706.07
<
2.
8 _ L O D
/� �� ♦ °3
FUTURE
MSIN LANDFLL ♦ ♦ ♦ c
11) ] (PHASES M TO IX) oo
_ I I
4 ,.� !!
I" ,♦ ! ! MW-18R�
_ ♦ ! ! 646.92 „!
PROPERTY
LINE
may! \
cLOBED �-_1 .5
DEMOLITION _ ♦ -
\ LANDFLL ♦ - ✓ \
N -
EXISTING >„ !I� ! ❑ SW-5
r SEDIMENT 0!
! BASH
1 i � .20
ON ✓ j G
01
1.67 A
0
j O
FRENCH DRAIN
SAMPLE POINT
!
I
!
C1
�)
54 `v.MW-27A•
!
656.2440
��
I
I
.....OMW-
sal, �!
!
\'� If
ill
a
EXISTING
SEDIMENT
BASIN
! 100-YEAR
FLOODPLAIN 1
J'
/f
ly,
EXISTING
SEDIMENT
BASIN
ue.,,o,,,
s 1.
'=SITE LOCATION
x.
�° irk , ��� ✓� }, /
ip
SITE LOCATION MAP
1" = 10,000'
CLIENT
ROWAN COUNTY
\ CONSULTANT PG C-399 YYYY-MM-DD 2020-03-12
(\ PREPARED HAC
I 1 G DESIGN NTT
=E NOTE 6) G O L D E R
REVIEW RPK
GOLDER ASSOCIATES NC, INC. APPROVED RPK
LEGEND
----ezo� EXISTING TOPOGRAPHIC CONTOUR
FACILITY BOUNDARY
APPROXIMATE LIMITS OF WASTE
_ 650 GROUNDWATER SURFACE CONTOURS
�"I APPROXIMATE GROUNDWATER FLOW SEGMENT USED TO CALCULATE GRADIENT
O647.56 EXISTING GROUNDWATER MONITORING WELL WITH GROUNDWATER ELEVATION
❑SW-4 SURFACE WATER MONITORING POINT
COMPLIANCE METHANE MONITORING POINT
ASSESSMENT METHANE MONITORING POINT
NM NOT MEASURED
® FRENCH DRAIN MONITORING POINT
NOTES
1. TOPOGRAPHIC CONTOUR INTERVAL = 2 FEET.
2. GROUNDWATER SURFACE CONTOUR INTERVAL = 10 FEET.
3. GROUNDWATER ELEVATIONS MEASURED ON JANUARY 16, 2020.
4. GROUNDWATER CONTOURS ARE BASED ON LINEAR INTERPOLATION BETWEEN AND
EXTRAPOLATION FROM KNOWN DATA, TOPOGRAPHIC CONTOURS, AND KNOWN FIELD CONDITIONS.
THEREFORE, GROUNDWATER CONTOURS MAY NOT REFLECT ACTUAL GROUNDWATER
CONDITIONS.
5. GROUNDWATER CONTOUR LINES SHOW THE WATER TABLE SHAPE AND ELEVATION. THESE
CONTOURS ARE INFERRED LINES FOLLOWING THE GROUNDWATER SURFACE AT CONSTANT
ELEVATION ABOVE SEA LEVEL. THE GROUNDWATER FLOW DIRECTION IS GENERALLY
PERPENDICULAR TO THE GROUNDWATER SURFACE CONTOURS, SIMILAR TO THE RELATIONSHIP
BETWEEN SURFACE WATER FLOW AND TOPOGRAPHIC CONTOURS.
6. SURFACE WATER MONITORING POINT SW-1 IS APPROXIMATELY 550 FEET OFF THE MAPPING LIMITS
SHOWN AND IS COLLECTED FROM SECOND CREEK.
7. MONITORING WELLS MW-27A, MW-28 AND MW-6 ARE UTILIZED FOR WATER LEVEL MONITORING
ONLY.
'bs 8. THE LOCATION OF THE FRENCH DRAIN MONITORING POINT IS APPROXIMATE.
9. MW-28R WAS INSTALLED JULY 11, 2017 TO REPLACE MW-28. MW-28 WILL CONTINUE TO BE UTILIZED
FOR WATER LEVEL MONITORING.
REFERENCES
1. OVERALL SITE BASE TOPOGRAPHY PROVIDED BY S&ME ENGINEERING, INC
0 250 500
SCALE FEET
PROJECT
ROWAN COUNTY ACTIVE AND CLOSED LANDFILLS
PERMIT NO.80-03
ROWAN COUNTY, NORTH CAROLINA
TITLE
GROUNDWATER CONTOUR MAP
JANUARY 13, 2020
PROJECT No. Rev. DRAWING
19123756 100 0
4INSTRUMENT CALIBRATION REPORT ,
Pine Environmental Services 1LLC
92 North Main St, Building 20
Windsor, NJ 08561
Toll -free: (800) 301-9663
Pine Environmental Services, Inc.
Instrument ID 15740
Description Gem 2000+
Calibrated 5/6/2020 2:44:30PM
Test Instruments Used During the Calibration
(As Of Cal Entry Date)
Serial Number /
Next Cal Date /
Test Standard ID
Description Manufacturer
Model Number Lot Number
Last Cal Date/ Expiration Date
Opened Date
NC 50 35
NC 50 CH4/35 CO2 Gasco
GP 12126 - 31803 CBJ-399-1
2/8/2023
CBJ-399-1
NC CO
CARBON Pine
BBH-408BST-
1000/112S50
MONOXIDE/HYDRO
1
GEN SULFIDE
Notes about this calibration
Calibration Result Calibration Successful
Who Calibrated Blaine Bunch
All instruments are calibrated by Pine Environmental Services LLC according to the manufacturer's
specifications, but it is the customer's responsibility to calibrate and maintain this unit in accordance with the
manufacturer's specifications and/or the customer's own specific needs.
Notify Pine Environmental Services LLC of any defect within 24 hours of receipt of equipment
Please call 800-301-9663 for Technical Assistance
Pine Environmental Services LLC Windsor Industrial Park, 92 North Main Street, Bldg 20, Windsor, NJ 08561, 800-301-9663
www.pine-environmental.com
INSTRUMENT CALIBRATION REPORT
Pine Environmental Services LLC
92 North Main St, Building 20
Windsor, NJ 08561
Toll -free: (800) 301-9663
Pine Environmental Services, Inc.
Instrument ID 15740
Description Gem 2000+
Calibrated 5/6/2020 2:44:30PM
Manufacturer
CES Landtec
State Certified
Model Number
GEM2000
Status Pass
Serial Number/ Lot
GM 12334/10
Temp °C 25
Number
Location
New Jersey
Humidity % 33
Department
Calibration Specifications
Group # 1
Range Acc %
0.0000
Group Name Methane
Reading Acc %
3.0000
Stated Accy Pet of Reading
Plus/Minus
0.0
Nom In Val / In Val In Type Out Val
Out Type
Fnd As
Lft As
Dev%
Pass/Fail
50.0/50.0 %Volume 50.0
%Volume
50.0
50.0
0.00%
Pass
Group # 2
Range Acc %
0.0000
Group Name Carbon Dioxide
Reading Acc %
3.0000
Stated Accy Pct of Reading
Plus/Minus
0.0
Nom In Val / In Val In Type Out Val
Out Type
Fnd As
Lft As
Dev%
Pass/Fail
35.0/35.0 %Volume 35.0
%Volume
35.0
35.0
0.00%
Pass
Group # 3
Range Acc %
0.0000
Group Name Oxygen
Reading Acc %
3.0000
Stated Accy Pct of Reading
Plus/Minus
0.0
Nom In Val / In Val In Type Out Val
Out Type
Fnd As
Lft As
Dev%
Pass/Fail
20.9 / 20.9 %Volume 20.9
%Volume
20.7
20.9
0.00%
Pass
Group # 4
Range Acc %
0.0000
Group Name Cabon Monoxide
Reading Acc %
3.0000
Stated Accy Pct of Reading
Plus/Minus
0.00
Nom In Val / In Val In Type Out Val
Out Type
Fnd As
Lft As
Dev%
Pass/Fail
1000.00 / 1000.00 PPM 1000.00
PPM
998.00
999.00
-0.10%
Pass
-----..__
Group # 5
Range Acc %
0.0000
Group Name Hydrogen Sulfide
Reading Acc %
3.0000
Stated Accy Pct of Reading Range
Plus/Minus
0.00
Nom In Val / In Val In Type Out Val
Out Type
Fnd As
Lft As
Dev%
Pass/Fail
50.00 / 50.00 PPM 50.00
PPM
49.00
50.00
0.00%
Pass
Pine Environmental Services LLC Windsor Industrial Park, 92 North Main Street, Bldg 20, Windsor, NJ 08561, 800-301-9663
www.pine-environmental.com
IDENR USE ONLY: I i ❑Paper Report [-]Electronic Data - Email CD (data loaded: Yes / No Doc/Event #:
NC DENR I Environmental Monitoring
Division of Waste Management - Solid Waste Reporting Form
Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Instructions:
Prepare one form for each individually monitored unit.
Please type or print legibly.
Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification
must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing
condition, etc.).
Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits.
Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the
facility (NCAC 13B .1629 (4)(a)(i).
Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste
Section, 1646 Mail Service Center, Raleigh, NC 27699-1646.
Solid Waste Monitoring Data Submittal Information
Name of entity submitting data (laboratory, consultant, facility owner):
Golder Associates NC, Inc. on behalf of Rowan County
Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address:
Name: Darren Cox Phone: 336-852-4903
E-mail: Darren_Cox@golder.com
NC Landfill Rule: Actual sampling dates (e.g.,
Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006)
Rowan County Landfills 789 Campbell Road 80-03 .1600 and .500 May 11, 2020
(Active MSW and Closed C&D) Woodleaf, NC 27054
Environmental Status: (Check all that apply)
❑ Initial/Background Monitoring Detection Monitoring Assessment Monitoring Corrective Action
of data submitted: (Check all that apply)
Groundwater monitoring data from monitoring wells ❑X
Groundwater monitoring data from private water supply wells ❑
Leachate monitoring data ❑
Surface water monitoring data
Methane gas monitoring data
Corrective action data (specify)
Other(specify)
Notification attached?
8 No. No groundwater or surface water standards were exceeded.
Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water
monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and
preliminary analysis of the cause and significance of any concentration.
❑ Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample
values and explosive methane gas limits.
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct.
Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas
levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there
are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment.
Rachel P. Kirkman Associate & Senior Consultant 336-852-4903
Facility Representative Name,(Print) Title (Area Code) Telephone Number
Signature Date
Golder Associates NC, Inc., 5B Oak Branch Drive, Greensboro, NC 27407
Facility Representative Address
Affix NC Licensed/ Professional Geologist Seal
���snmraurq�y�
G
i I AC t_i A V O !
PE C-2862: PG C-399
NC PE Firm License Number (if applicable effective May 1, 2009)
Revised 6/2009
OX• (