Loading...
HomeMy WebLinkAbout8003_Rowan_MSWLF_CDLF_May2020LFG_FID1406302_20200515GOLDER May 12, 2020 Ms. Jaclynne Drummond, Compliance Hydrogeologist North Carolina Department of Environmental Quality Division of Waste Management - Solid Waste Section 2090 US Highway 70 Swannanoa, North Carolina 28778 (828) 296-4706 Project No. 19123756.200 RE: METHANE MONITORING RESULTS — SECOND QUARTERLY EVENT — MAY 2020 ROWAN COUNTY LANDFILL, PERMIT NO. 80-03 ROWAN COUNTY, NORTH CAROLINA Dear Jackie, Attached are the results from the May 11, 2020, quarterly methane monitoring event conducted at the above - referenced facility. No methane gas was detected in the facility structures during this monitoring event. Permanent explosive gas monitoring devices are located in the scale -house and maintenance building. Methane gas was not detected in compliance monitoring points at concentrations above the lower explosive limit (LEL) during the second quarterly methane monitoring event. The next monitoring event is tentatively scheduled for September 2020. If you have any questions or concerns, please contact us at 336 852-4903. Sincerely, Golder As ciates NC, Inc. Nicolas Tejeda-Torres Rachel P. Kirkman, P.G. Geologist Associate & Senior Consultant NTT/RPK/ntt: Golder Associates NC, Inc. 5B Oak Branch Drive Greensboro, North Carolina, USA 27407 T: +t 336 852-4903 +t 336 852-4904 Golder and the G logo are trademarks of Golder Associates Corporation golder.com Ms. Jaclynne Drummond, Compliance Hydrogeologist North Carolina Department of Environmental Quality CC: Caleb Sinclair, Environmental Management Director, Rowan County Department of Environmental Management, 1102 N Long Street Extension, East Spencer, NC 28039 Jeff Boyd, Landfill Supervisor, Rowan County Department of Environmental Management, 789 Campbell Road, Woodleaf, NC 27054 Mike Plummer, PE, HDR, 440 S. Church Street, 10th Floor, Charlotte, NC 28202, mplummer@hdrinc.com (electronic only) Attachments: Boundary Gas Probe Monitoring Log — May 11, 2020 Methane Monitoring Location Map Calibration Certificate Environmental Monitoring Form g:\projects\rowan\19123756(2020)\phase 200 methane reports\200 dely\200 drafts issued\2nd quaterly methane 2020\05-11-2020 methane monitoring report.docx Project No. 19123756.200 May 12, 2020 GOLDER NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This farni and any it formation attached to it are "Public Records"as defined in NC General Stat:ae 132-1. As such. these documents are available for inspection and exaniiiiation by any person upon request (dC General Statute 132-6). Facility Name: Rowan County Landfill Sampling Date: 05/1 1 /2020 Sample Collector Name & Position: ermitNumber: 80-03 Landfill Rule (.0500 or. 1600): Nicolas Tejeda-Torres .1600 and .0500 Gas Meter Type & Serial Number: GEM 2000 Plus Gas Meter Calibration Date: 05/06/2020 Field Calibration Date & Time: 05/1 1 /2020 1 3.27 Field Calibration Gas Type (15115 or35/50): 1 5/1 5 Gas Meter Pump Rate: 300 cc/min ield Calibration Gas Canister Expiration Date: 11 /09/2020 Ambient Air Temperature: 61 � F Barometric Pressure (in. or minHg): 29.01 Weather Conditions: Partly Cloudy, winds NW 18mph Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and�or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Primped (sec) "Initial % LEL Stabilized %LEL % CH4 (volume) % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES MMW-1 13:56 90 0 0 0.0 18.1 3.4 0.0 MMW-2A 14:07 90 0 0 0.0 20.3 0.5 0.0 MMW-3 14:11 90 0 0 0.0 19.7 1.7 0.0 MMW-4 14:16 90 0 0 0.0 11.2 8.7 0.0 MMW-5A 14:20 90 0 0 0.0 14.9 3.9 0.0 MMW-6A 14:24 90 0 0 0.0 14.7 3.1 0.0 MMW-7 14:32 90 0 0 0.0 17.9 3.8 0.0 MMW-CD 13:50 90 0 0 0.0 20.1 0.6 0.0 Maintenance Building 13:37 300 0 0 0.0 21.0 0.0 0.0 Scalehouse 13:31 300 0 0 0.0 21.0 0.0 0.0 MMW-2(NotCompliance) 14:00 90 0 0 0.0 20.2 1.5 0.0 MMW-5(NotCompliance) 14:39 1 90 0 0 0.0 20.1 0.5 0.0 NOTE: /f needed. attach additional data fornis to include additional LFG monitoring data locations for the facility. AC11-I01, LEN ELS: Methane: >1.25% by volume (inside structures) AND >S% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my ledge, the information reported and statements made on this data submittal and attachments are true and c r . I am aware th re are significant penalties for making any false statement, representation, or certific ro ncluding the po rb' ty of 4.1yne and imprisonment. Geologist TURE TITLE Revised - March 6, 2017 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records "as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Rowan County Landfill Permit Number. 80-03 Sampling Date: 05/11 /2020 Sample Collector Name & Position: Landfill Rule (.0500 or .1600): Nicolas Tejeda-Torres Gas Meter Type & Serial Number: G E M 2000 Plus Field Calibration Date & Time: 05/1 1 /2020 13:27 .1600 and .0500 Gas Meter Calibration Date: 05/06/2020 Field Calibration Gas Type (15115 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 11 /09/2020 Gas Meter Pump Rate: 300 cc/min 61 OF 29.01 Partly Cloudy, winds NW 18mph Ambient Air Temperature: Barometric Pressure (in. or min Hg): Weather Conditions: Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped p (sec) Initial %LEL Stabilized %LEL % CH4 (volume) volume 0 /0 02 (volume) 0 /o CO2 (volume) 0 /o H2S (volume) NOTES MMW6(Not Conpliance) 14:26 90 0 0 2.4 16.2 3.3 0.0 MMW-B(Nol Compliance) 13:44 90 62.0 62.0 1.7 10.4 11.2 0.0 NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >I % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best o knowledge, the inf ation reported and statements made on this data submittal and attachments are true d rrect. I am aware a ere are significant penalties for making any false statement, representation, or certification including the ssi ity of a fine an ' risonment. Geologist AT TITLE Revised — March 6, 2017 OLD EXISTING LANDFILL SEDIMENT ENTRANCE BASIN i ,i, MMW-5A� _... I /_PHASE I WLA DFLL _ Dill 0 EXISTING SEDIMEN BASIN M 48� i �,{L}'�"�' ♦ PHASE MOW LA DFLL o 1 o I PHASE 0 MOW LA DFLL , MW-200 , 684.80 I o o MMW-70- I ♦,I ♦♦ o _ ♦ ♦� , lo o ♦�, I I' M661 1 _ ♦ - 61 1s02�♦_ 4* ✓ ,�♦ PHASE N AFEA "\\' ! 1 �! 611.400 ! ; I ! FUTURE MSW LANDFILL 1 _ - I (PHASES IV &V) L-- 41 1 _ N SCALE HOUSE MW-16 706x42 �. �c TAW -CD ______— W17 .\ - - 706.07 < 2. 8 _ L O D /� �� ♦ °3 FUTURE MSIN LANDFLL ♦ ♦ ♦ c 11) ] (PHASES M TO IX) oo _ I I 4 ,.� !! I" ,♦ ! ! MW-18R� _ ♦ ! ! 646.92 „! PROPERTY LINE may! \ cLOBED �-_1 .5 DEMOLITION _ ♦ - \ LANDFLL ♦ - ✓ \ N - EXISTING >„ !I� ! ❑ SW-5 r SEDIMENT 0! ! BASH 1 i � .20 ON ✓ j G 01 1.67 A 0 j O FRENCH DRAIN SAMPLE POINT ! I ! C1 �) 54 `v.MW-27A• ! 656.2440 �� I I .....OMW- sal, �! ! \'� If ill a EXISTING SEDIMENT BASIN ! 100-YEAR FLOODPLAIN 1 J' /f ly, EXISTING SEDIMENT BASIN ue.,,o,,, s 1. '=SITE LOCATION x. �° irk , ��� ✓� }, / ip SITE LOCATION MAP 1" = 10,000' CLIENT ROWAN COUNTY \ CONSULTANT PG C-399 YYYY-MM-DD 2020-03-12 (\ PREPARED HAC I 1 G DESIGN NTT =E NOTE 6) G O L D E R REVIEW RPK GOLDER ASSOCIATES NC, INC. APPROVED RPK LEGEND ----ezo� EXISTING TOPOGRAPHIC CONTOUR FACILITY BOUNDARY APPROXIMATE LIMITS OF WASTE _ 650 GROUNDWATER SURFACE CONTOURS �"I APPROXIMATE GROUNDWATER FLOW SEGMENT USED TO CALCULATE GRADIENT O647.56 EXISTING GROUNDWATER MONITORING WELL WITH GROUNDWATER ELEVATION ❑SW-4 SURFACE WATER MONITORING POINT COMPLIANCE METHANE MONITORING POINT ASSESSMENT METHANE MONITORING POINT NM NOT MEASURED ® FRENCH DRAIN MONITORING POINT NOTES 1. TOPOGRAPHIC CONTOUR INTERVAL = 2 FEET. 2. GROUNDWATER SURFACE CONTOUR INTERVAL = 10 FEET. 3. GROUNDWATER ELEVATIONS MEASURED ON JANUARY 16, 2020. 4. GROUNDWATER CONTOURS ARE BASED ON LINEAR INTERPOLATION BETWEEN AND EXTRAPOLATION FROM KNOWN DATA, TOPOGRAPHIC CONTOURS, AND KNOWN FIELD CONDITIONS. THEREFORE, GROUNDWATER CONTOURS MAY NOT REFLECT ACTUAL GROUNDWATER CONDITIONS. 5. GROUNDWATER CONTOUR LINES SHOW THE WATER TABLE SHAPE AND ELEVATION. THESE CONTOURS ARE INFERRED LINES FOLLOWING THE GROUNDWATER SURFACE AT CONSTANT ELEVATION ABOVE SEA LEVEL. THE GROUNDWATER FLOW DIRECTION IS GENERALLY PERPENDICULAR TO THE GROUNDWATER SURFACE CONTOURS, SIMILAR TO THE RELATIONSHIP BETWEEN SURFACE WATER FLOW AND TOPOGRAPHIC CONTOURS. 6. SURFACE WATER MONITORING POINT SW-1 IS APPROXIMATELY 550 FEET OFF THE MAPPING LIMITS SHOWN AND IS COLLECTED FROM SECOND CREEK. 7. MONITORING WELLS MW-27A, MW-28 AND MW-6 ARE UTILIZED FOR WATER LEVEL MONITORING ONLY. 'bs 8. THE LOCATION OF THE FRENCH DRAIN MONITORING POINT IS APPROXIMATE. 9. MW-28R WAS INSTALLED JULY 11, 2017 TO REPLACE MW-28. MW-28 WILL CONTINUE TO BE UTILIZED FOR WATER LEVEL MONITORING. REFERENCES 1. OVERALL SITE BASE TOPOGRAPHY PROVIDED BY S&ME ENGINEERING, INC 0 250 500 SCALE FEET PROJECT ROWAN COUNTY ACTIVE AND CLOSED LANDFILLS PERMIT NO.80-03 ROWAN COUNTY, NORTH CAROLINA TITLE GROUNDWATER CONTOUR MAP JANUARY 13, 2020 PROJECT No. Rev. DRAWING 19123756 100 0 4INSTRUMENT CALIBRATION REPORT , Pine Environmental Services 1LLC 92 North Main St, Building 20 Windsor, NJ 08561 Toll -free: (800) 301-9663 Pine Environmental Services, Inc. Instrument ID 15740 Description Gem 2000+ Calibrated 5/6/2020 2:44:30PM Test Instruments Used During the Calibration (As Of Cal Entry Date) Serial Number / Next Cal Date / Test Standard ID Description Manufacturer Model Number Lot Number Last Cal Date/ Expiration Date Opened Date NC 50 35 NC 50 CH4/35 CO2 Gasco GP 12126 - 31803 CBJ-399-1 2/8/2023 CBJ-399-1 NC CO CARBON Pine BBH-408BST- 1000/1­12S50 MONOXIDE/HYDRO 1 GEN SULFIDE Notes about this calibration Calibration Result Calibration Successful Who Calibrated Blaine Bunch All instruments are calibrated by Pine Environmental Services LLC according to the manufacturer's specifications, but it is the customer's responsibility to calibrate and maintain this unit in accordance with the manufacturer's specifications and/or the customer's own specific needs. Notify Pine Environmental Services LLC of any defect within 24 hours of receipt of equipment Please call 800-301-9663 for Technical Assistance Pine Environmental Services LLC Windsor Industrial Park, 92 North Main Street, Bldg 20, Windsor, NJ 08561, 800-301-9663 www.pine-environmental.com INSTRUMENT CALIBRATION REPORT Pine Environmental Services LLC 92 North Main St, Building 20 Windsor, NJ 08561 Toll -free: (800) 301-9663 Pine Environmental Services, Inc. Instrument ID 15740 Description Gem 2000+ Calibrated 5/6/2020 2:44:30PM Manufacturer CES Landtec State Certified Model Number GEM2000 Status Pass Serial Number/ Lot GM 12334/10 Temp °C 25 Number Location New Jersey Humidity % 33 Department Calibration Specifications Group # 1 Range Acc % 0.0000 Group Name Methane Reading Acc % 3.0000 Stated Accy Pet of Reading Plus/Minus 0.0 Nom In Val / In Val In Type Out Val Out Type Fnd As Lft As Dev% Pass/Fail 50.0/50.0 %Volume 50.0 %Volume 50.0 50.0 0.00% Pass Group # 2 Range Acc % 0.0000 Group Name Carbon Dioxide Reading Acc % 3.0000 Stated Accy Pct of Reading Plus/Minus 0.0 Nom In Val / In Val In Type Out Val Out Type Fnd As Lft As Dev% Pass/Fail 35.0/35.0 %Volume 35.0 %Volume 35.0 35.0 0.00% Pass Group # 3 Range Acc % 0.0000 Group Name Oxygen Reading Acc % 3.0000 Stated Accy Pct of Reading Plus/Minus 0.0 Nom In Val / In Val In Type Out Val Out Type Fnd As Lft As Dev% Pass/Fail 20.9 / 20.9 %Volume 20.9 %Volume 20.7 20.9 0.00% Pass Group # 4 Range Acc % 0.0000 Group Name Cabon Monoxide Reading Acc % 3.0000 Stated Accy Pct of Reading Plus/Minus 0.00 Nom In Val / In Val In Type Out Val Out Type Fnd As Lft As Dev% Pass/Fail 1000.00 / 1000.00 PPM 1000.00 PPM 998.00 999.00 -0.10% Pass -----..__ Group # 5 Range Acc % 0.0000 Group Name Hydrogen Sulfide Reading Acc % 3.0000 Stated Accy Pct of Reading Range Plus/Minus 0.00 Nom In Val / In Val In Type Out Val Out Type Fnd As Lft As Dev% Pass/Fail 50.00 / 50.00 PPM 50.00 PPM 49.00 50.00 0.00% Pass Pine Environmental Services LLC Windsor Industrial Park, 92 North Main Street, Bldg 20, Windsor, NJ 08561, 800-301-9663 www.pine-environmental.com IDENR USE ONLY: I i ❑Paper Report [-]Electronic Data - Email CD (data loaded: Yes / No Doc/Event #: NC DENR I Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Golder Associates NC, Inc. on behalf of Rowan County Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Darren Cox Phone: 336-852-4903 E-mail: Darren_Cox@golder.com NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) Rowan County Landfills 789 Campbell Road 80-03 .1600 and .500 May 11, 2020 (Active MSW and Closed C&D) Woodleaf, NC 27054 Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring Detection Monitoring Assessment Monitoring Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells ❑X Groundwater monitoring data from private water supply wells ❑ Leachate monitoring data ❑ Surface water monitoring data Methane gas monitoring data Corrective action data (specify) Other(specify) Notification attached? 8 No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. ❑ Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Rachel P. Kirkman Associate & Senior Consultant 336-852-4903 Facility Representative Name,(Print) Title (Area Code) Telephone Number Signature Date Golder Associates NC, Inc., 5B Oak Branch Drive, Greensboro, NC 27407 Facility Representative Address Affix NC Licensed/ Professional Geologist Seal ���snmraurq�y� G i I AC t_i A V O ! PE C-2862: PG C-399 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 OX• ( p43j� P.