Loading...
HomeMy WebLinkAbout4501_Henderson_MSWLF_CDLF_May2020LFG_FID1406301_20200518kUSE ONLY [:]Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #: NC DENR Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Golder Associates NC, Inc. on behalf of Henderson County Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: David Y. Reedy II Phone: 336-852-4903 E-mail: dreedy@golder.com NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) Henderson County Closed Landfill 191 Transfer Station Drive 45-01 .1600/.0500 May 13, 2020 Hendersonville, NC 28791 Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring Detection Monitoring ❑X Assessment Monitoring ❑X Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells ❑X Groundwater monitoring data from private water supply wells ❑ Leachate monitoring data 1-1Surface water monitoring data Methane gas monitoring data Corrective action data (specify) Other(specify) Notification attached? eX No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. ❑ Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. David Y. Reedy II, PG Facility Reqjgse"ve Name nature Senior Hydrogeologist Title Golder Associates NC, Inc., 5B Oak Branch Drive, Greensboro, NC 27407 Facility Representative Address C-2862 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 •/a•20 Date 336-852-4903 (Area Code) Telephone Number Affix NC Licensed/ Professional Geologist Seal GOLDER May 18, 2020 Ms. Jaclynne Drummond, Hydrogeologist North Carolina Department of Environmental Quality Division of Waste Management - Solid Waste Section 2090 US Highway 70 Swannanoa, North Carolina 28778 828-296-4706 jaclynne.drummond@ncdenr.gov METHANE MONITORING RESULTS — SECOND QUARTERLY EVENT OF 2020 CLOSED HENDERSON COUNTY LANDFILL, PERMIT NO. 45-01 HENDERSON COUNTY, NORTH CAROLINA Dear Jackie, 19128179.204 Attached are the results from the May 13, 2020, second quarterly methane monitoring event conducted at the above -referenced facility. As shown on the attached Boundary Gas Probe Monitoring Log, methane was not detected above the lower explosive limit (LEL) in any compliance methane monitoring points. No methane was detected in the facility structures during this compliance monitoring event. If you have any questions or concerns, please contact us at 336-852-4903. Sincerely, Golder Associates NC, Inc. 4? �: 4-Z ce, 00 1 �_ 16ci—-11 r"c�,.. David "Dusty" Y. Reedy II, PG Rachel P. Kirkman, PG Senior Hydrogeologist Associate and Senior Consultant Golder Associates NC, Inc. 5B Oak Branch Drive, Greensboro, North Carolina, USA 27407 Engineering Lic. No. C-2862/Geology Lic. No. C-399 T: +1 336 852-4903 F: +1 336 852-4904 Golder Associates NC, Inc. is a licensed user of the Golder trademark, and an associated operating entity. Golder and the G logo are trademarks of Golder Associates Corporation. golder.com Ms. Jaclynne Drummond, Hydrogeologist North Carolina Department of Environmental Quality CC: Marcus Jones, PE, Director of Engineering, Henderson County, 1 Historic Courthouse Square, Suite 6, Hendersonville, NC 28792. 828-694-6560. majones@hendersoncountync.org Greg Wiggins, Operations Manager, Henderson County, 191 Transfer Station Drive, Hendersonville, North Carolina 28791. 828-694-7982. gwiggins@hendersoncountync.org Attachments: Boundary Gas Probe Monitoring Log — May 13, 2020 Cut-off Trench LFG Vent Monitoring Log — May 13, 2020 Methane Monitoring Location Map Calibration Record https://golderassociates.sharepoint.com/sites/125046/19128179/phase 204- 2nd qtr Ifg 2020/200 deliverables/252 final issued/19128179.203-r-001-rev0- 1 st_gtr_lfg_rpt.docx 19128179.204 May 18, 2020 4 GOLDER NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This fo•nn and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available fo• inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Henderson County Landfill Sampling Date: 05/13/2020 Number: 45-01 Landfill Rule (.0500 or. 1600): Sample Collector Name & Position: Nicolas Tejeda-Torres, Geologist Gas Meter Type & Serial Number: G E M 2000+ Gas Meter Calibration Date: Field Calibration Date & Time: 05/13/2020, 11:57 Field Calibration Gas Type (15115 or35/50): 1 5/1 5 F Gas Meter Pump Rate: 300 cc/min 05/06/2020 eld Calibration Gas Canister Expiration Date: 2/21 /2021 Ambient Air Temperature: 560 F Barometric Pressure (in. or min Hg): 28.05" Weather Conditions: Cloudy, winds 5mph Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and�or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized % LEL %CH4 ( ) volume % 02 volume (Volume) % CO2 volume (Volume) %H2S* volume (volume) NOTES MP-1 14:19 60 0 0 0.0 14.9 4.5 0 MP-3 14:11 60 2 2 0.1 15.6 4.5 0 MP-4 13:40 60 0 0 0.0 19.5 0.7 0 MP-7 13:59 60 0 0 0.0 12.3 5.4 0 MP-8 13:21 60 0 0 0.0 18.0 1.9 0 MP-9 13:12 60 0 0 0.0 18.6 2.1 0 Activity Building 12:24 60 0 0 0.0 20.4 0.0 0 Animal Shelter 12:58 60 0 0 0.0 20.5 0.0 0 Break House 12:29 60 0 0 0.0 20.5 0.0 0 Bus Garage 12:47 60 0 0 0.0 20.5 0.0 0 Convenience Center 13:02 60 0 0 0.0 20.6 0.0 0 'The Landtec GEM 2000+ has a Maintenance Shop 12:34 1 60 0 0 0.0 20.5 0.0 0 CH4 accuracy range of +/- 0.3% NOTE: If needed, attach additional data fornns to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Senior Hydrogeologist SIGNAT TITLE Revised - March 6, 2017 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records"as defined in AV General Statute 132-1. As s:tch, these documents are available for inspection and examination by any person upon request (AIC General Statute 132-6). Facility Name: Henderson County Landfill Number: 45-01 Sampling Date: 05/1 3/2020 NC Landfill Rule (.0500 or.1600): Sample Collector Name &Position: Nicolas Tejeda-Torres, Geologist Gas Meter Type & Serial Number: G E M 2000+ Gas Meter Calibration Date: Field Calibration Date & Time: 05/13/2020, 11:57 05/06/2020 Field Calibration Gas Type (15115 or 35/50): 1 5/1 5 Field Calibration Gas Canister Expiration Date: 2/21 /2021 Gas Meter Pump Rate: 300 cc/min Ambient Air Temperature: 560E Barometric Pressure (in. or mm Hg): 28.0511 Weather Conditions: Cloudy, Winds 5mph Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required far Construction & Demolition Landfills (CDLFs). See individual permit conditions and�or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized % LEL ° /°CH4 (volume) % 02 (volume) % CO2 (volume) %H2S* (volume) NOTES Scalehouse 12:12 60 0 0 0.0 20.5 0.0 0 Trace Barn 13:06 60 0 0 0.0 20.4 0.0 0 MP-6 13:32 60 0 0 0.0 20.7 0.0 0 TR-2 13:25 60 20 20 1.0 19.1 2.1 0 TR-3 14:01 60 14 14 0.7 17.1 4.7 0 LFG-101 14:27 60 0 0 0.0 20.7 0.1 0 LFG-102 14:23 60 0 0 0.0 18.2 1.4 0 LFG-103 14:32 60 0 0 0.0 15.3 4.9 0 `The Landtec GEM 2000+ has a CH4 accuracy range of +/- 0.3% NOTE: 1f needed, attach additional data forms to include additional LFG monitoring data locations for- the facility. ACTION, LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1% by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Senior Hydrogeologist SIGNATUKE TITLE Revised — March 6, 2017 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Henderson County Landfill Permit Number: 45-01 Sampling Date: 05/13/2020 Sample Collector Name & Position: Landfill Rule (.0500 or .1600): Nicolas Tejeda-Torres, Geologist Gas Meter Type & Serial Number: G E NI 2000+ Field Calibration Date & Time: 05/13/2020, 11:57 Gas Meter Calibration Date: 05/06/2020 Field Calibration Gas Type (15115 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 2/2 /2O2 Gas Meter Pump Rate: 300 cc/min Ambient Air Temperature: 56o F Barometric Pressure (in. or min Hg): 28.05" Weather Conditions: Cloudy, Winds 5mph Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LEG Well ID Sample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized % LEL % CH4 volume (volume) % 02 (volume) % CO2 (volume) % H2S• (volume) NOTES Cut-off Trench Vent 1 13:56 60 30 30 1.5 8.7 5.8 0 Cut-off Trench Vent 2 13: 50 60 10 10 0.5 19.5 0.6 0 *The Landtec GEM 2000+ has a CH4 accuracy range of +/- 0.3% NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >I % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Senior Hydrogeologist SIGNAT TITLE Revised — March 6, 2017 PeN: V1pleanGeltlCAVi_2008'A939fi509 - �WGT 1 • 2W19 LFG RnreEie6en Plan% I FIa Name-093B6 l510 .dwq z m~ O 0 0 z a In mxz- n z;X A g �n 0 C Z r 0 a m i m y' ❑ a m z m S ❑ 0 20 cl n z T1 r r III A m m A m 2 m x fl B2 �8 80 2q2 o n s rp qC �O C m nn 8q z-. � N n 8 n � z x p S m N Na N� n �8 A g� x W as a a� pa y� rimiliffill-®rAWMI ArA � l c 'jjJ 1 O4TZ M- i INSTRUMENT CALIBRATION REPORT Pine Environmental Services LLC 92 North Main St, Building 20 Windsor, NJ 08561 Toll -free: (800) 301-9663 Pine Environmental Services, Inc. instrument ID 15740 Description Gem 2000+ Calibrated 5/6/2020 2:44:30PM Manufacturer CES Landtec State Certified Model Number GEM2000 Status Pass Serial Number/ Lot GM12334/10 Temp °C 25 Number Location New Jersey Humidity % 33 Department Calibration Specifications Group # I Range Ace % 0.0000 Group Name Methane Reading Ace % 3.0000 Stated Accy Pct of Reading Plus/Minus 0.0 Nom In Val / In Val In Type Out Val Out Type Fnd As Lft As Dev% Pass/Fail 50.0 / 50.0 %Volume 50.0 %Volume 50.0 50.0 0.00% Pass Group # 2 Range Ace % 0.0000 Group Name Carbon Dioxide Reading Ace % 3.0000 Stated Accy Pct of Reading Plus/Minus 0.0 Nom In Val / In Val In Type Out Val Out Tvpe Fnd As Lft As Dev% Pass/Fail 35.0 / 35.0 %Volume 35.0 ------ -- - -- ------------- ----- ---------- --- - ----------- %Volume ----------------- - 35.0 ------- 35.0 ------------------ 0.00% Pass _ Group # 3 Range Ace % 0.0000 Group Name Oxygen Reading Ace % 3.0000 Stated Accy Pct of Reading Plus/Minus 0.0 Nom In Val ! In Val In Type Out Val Out Type Fnd As Lft As Dev% Pass/Fail 20.9 / 20.9 %Volume 20.9 %Volume ------------ --- 20.7 ---------------------------------- 20.9 0.00% ---------- --- Pass --- --------------- -- Group# 4 Range Ace% 0.0000 Group Name Cabon Monoxide Reading Ace % 3.0000 Stated Accy Pet of Reading Plus/Minus 0.00 Nom In Val / In Val In Type Out Val Out Tvpe Fnd As Lft As Dev% Pass/Fail 1000.00 / 1000.00 PPM 1000.00 - - ------------- --- ---------------------- - PPM -------------------- --- 998.00 ------------------------- 999.00 ---------- -0.10% ----------- Pass --------- ----------------- Group # 5 Range Ace % 0.0000 Group Name Hydrogen Sulfide Reading Ace % 3.0000 Stated Accy Pet of Reading Range Plus/Minus 0.00 Nom In Val / In Val In Type Out Val Out Type Fnd As Lft As Dev% Pass/Fail 50.00 / 50.00 PPM 50.00 PPM 49.00 50.00 0.00% Pass Pine Environmental Services LLC Windsor Industrial Park, 92 North Main Street, Bldg 20, Windsor, NJ 08561, 800-301-9663 www.pine-environmental.com I INSTRUMENT CALIBRATION REPORT Pine Environmental Services LLC 92 North Main St, Building 20 Windsor, NJ 08561 Toll -free: (800) 301-9663 Pine Environmental Services, Inc. Instrument ID 15740 Description Gem 2000+ Calibrated 5/6/2020 2:44:30PM Test Instruments Used During the Calibration (As Of Cal Entry Date) Serial Number / Next Cal Date / Test Standard ID Description Manufacturer Model Number Lot Number Last Cal Date/ Expiration Date Opened Date NC 50 35 NC 50 CH4/35 CO2 Gasco GP 12126 - 31803 CBJ-399-1 2/8/2023 CBJ-399-1 NC CO CARBON Pine BBFI-408BST- I000/1-12S50 MONOXIDE/HYDRO I GEN SULFIDE Notes about this calibration Calibration Result Calibration Successful Who Calibrated Blaine Bunch All instruments are calibrated by Pine Environmental Services LLC according to the manufacturer's specifications, but it is the customer's responsibility to calibrate and maintain this unit in accordance with the manufacturer's specifications and/or the customer's own specific needs. Notify Pine Environmental Services LLC of any defect within 24 hours of receipt of equipment Please call 800-301-9663 for Technical Assistance Pine Environmental Services LLC Windsor Industrial Park, 92 North Main Street, Bldg 20, Windsor, NJ 08561, 800-30I-9663 www. pine -environmental. com