Loading...
HomeMy WebLinkAbout6301_Moore_MSWLF_CDLF_April20LFG_FID1395726_202004014WMIAlln C DENR " Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: • Prepare one form for each individually monitored unlL • Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, preexisting condition, etc.). • Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. • Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This Includes any structures on or nearby the facility (NCAC 138 .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. owner): Golder Associates INC, Inc. (on behalf of Moore County) Contact for questions about date formatting. Include data preparers name, telephone number and E-mail address: Name: Benjamin S. Draper, PG Phone: 336-862-1903 E-mail: bdreper@golder.cem NC Landfill Rute: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit# (.0500 or.1600) October 20-24, 2006) 456 Moore County Landfill TurningLeaf 63-pt .0500 Aberdeen,en,f WFApnI72020 NC of Environmental Status: (Check all that apply) ❑ Ini iallBadiground Monitoring ❑ Detection Monitoring of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells Groundwater monitoring data from private water supply wells Leachate monitoring data Surface water monitoring data ❑ Assessment Monitoring XX Corrective Action QX Methane gas monitoring data Corrective action data (specify) Other(specify) NotMeation attached? eNo. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dales, analytical values, NC 2L groundwater standard, NC 28 surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and COrrGCL Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment Benjamin S. Draper, PG Facility Repres a Senior Project Geologist eY Date Golder Associates NC, Inc., 5B Oak Branch Drive, Greensboro, NC 27407 Facility Representative Address PE C-2862; PG C-399 NC PE Firm License Number (d applicable effective May 1, 2009) 336-8524903 (Area Code) Telepha Affix NC t1 G A j�Q Geologist Seal 0 GA1". L s 231 tz p�OG1g z Revised 6/2009 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: Thisform andany information attached to it are "Public Records"as dined in NC Genera! Statute 132-1. As such, these documents are available for inspection mid examination by am' person upon request (SC General Statute 132-6). FacilityName: Moore County Landfill Sampling Date: 04/07/2020 N Sample Collector Name & Position: Nicolas T Gas Meter Type & Serial Number: Field Calibration Date & Time: GEM 5000 Number: 63-01 Landfill Rule (.0500 or.1600): eda-Torres 04/07/2020 11:35 0500 Gas Meter Calibration Date: 03/31 /2020 Field Calibration Gas Type (115/15 5/I5 or 35150): Field Calibration Gas Canister Expiration Date: 01/06/2021 Gas Meter Pump Rate: 300 cc/min Ambient Air Temperature: 77 F Barometric Pressure (in. or nun 29,79 Hg): Weather Conditions: Fair, winds SW at 5mph Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location may or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. "Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well iD Sample Tube Purge Time of Day Time Pum (sac) ,:) Initial % LEL Stabilized %LEL %CH4 (volume) op o 02 (volume) v CO_ (volume) oa v lum (volume) NOTES GP-9 60 13:29 60 0 0 0.0 20.5 0.2 0 1 Inch Well GP-10 60 13:22 60 374 374 32.2 3.9 11.1 16 1 Inch Well GP-11 60 1 13:36 60 0 0 0.0 11.1 6.1 0 1 Inch Well GP-12 60 13:44 60 0 0 0.0 20.3 0.3 0 1 1 Inch Well GP-13 60 12:13 60 0 0 0.0 19.1 0.6 0 1 Inch Well GP-13R 60 12:17 60 0 0 0.0 19.0 0.9 0 1 Inch Well GP-14 60 12:26 60 0 0 0.0 14.6 5.1 0 1 Inch Well GP-14R 60 12:21 60 0 0 0.0 18.9 0.4 0 1 Inch Well GP-15 60 12:45 60 0 0 0.0 9.1 5.5 0 1 Inch Well GP-15R 60 12:33 60 0 0 0.0 18.7 0.5 0 1 Inch Well GP-16 60 12:51 60 0 0 0.0 15.9 4.1 0 1 Inch Well GP-17 60 13:50 60 0 0 0.4 0.9 13.3 0 1 Inch Well ,VOTE: !f needed, attach addiliowl dam forms to include additional LFG monitoring data lowitors jar the facility. V UION Lt:v ELti: Methane: I._>",b by volume (inside structures) AND ",, by volume (at facility boundary) Hydrogen Sulfide: - by volume (inside structures) AND _- by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or Bert' catiog.'mc •ng the possibility of a fine and imprisonment. Geologist SIGNATURE Njcot�f•s T6Ta0w-rattc5 TITLE Revised -March 6, 2017 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form mid mry infornmlion mtac)wd io it are "Public Remrds" as dined in NC General Statute 132-1. As such these documents are available for inspecifon and exanrinarion by any person upon request (NC General.Statute 132-6). Facility Name: Moore County Landfill Number: 63-01 Sampling Date: 4/07/2020 NC Landfill Rule (.0500 or.1600): Sample Collector Name & Position: Nicolas Tejeda-Torres Gas Meter Type & Serial Number: GEM 5000 Field Calibration Date & Time: 04/07/2020 11:35 0500 Gas Meter Calibration Date: 03/31 /2020 Field Calibration Gas Type (15/15 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 2/21 /21 Gas Meter Pump Rate: 300 cc/min Ambient Air Temperature: 77 F Barometric Pressure (in. or rum 29.79 Hg): Weather Conditions: Fair, winds SW at 5mph Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. "Hydrogen Suy7de (H2S) gas monitoring may be required.for Construction &. Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped (sec) Initial % �- Stabilized % LEL % CH4 (volume) r o 4o O_ (volume) v Cme (volume) o, o •� / (volume) (volume) NOTES MW-6 60 16:36 60 238 238 23.6 10.2 11.7 0 2 Inch Groundwater Well MW-15 60 13:04 60 562 562 59.9 0.2 33.3 0 cvaa fees vam) 60 13:09 60 718 718 42.0 0.9 33.5 1 Gas Vent ov-saiweam,v"m, 60 13:11 60 0 0 9.0 15.4 6.9 1 Gas Vent SCALEHOUSE 60 12:00 90 0 0 0.0 19.8 0.0 0 Building Mariumwce Shop 60 12:08 90 0 0 0.0 19.7 0.0 0 Building Transfer station 60 12:04 90 0 0 0.0 19.7 0.0 0 Building 60 16:36 90 0 0 0.0 20.8 0.0 0 Building The Landtec GEM 5000 has a CH4 accuracy range of+/- 0.3 % NOTE: Ifneeded,, attach additional dala forms is include additional LFG monitoring data lowllonsfor thefacilin'. • +� .! v I Methane: r .]> by volume (insidc structures) AND ->` .by volume (at facility boundary) Hydrogen Sulfide: by volume (inside structures) AND by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certific 'on d't mcluhe possibility of a fine and imprisonment. 2 Geologist p re GNATUAE r/d,eeL.t•f TITLE Revised —March 6, 2017 LEGEND SW-2 [']� l�\ DENSE GETATION ,I DENSE VEGETATION I \ DENSE VEGETATION I` DENSE GETATION GROUND OBSCURED DENSE VEGETATION SEE ACCURACY NOTE \ DE VEGETATION GROUND OBSCURED SEE ACCURACY NOTE SITE LOCATION MAP NOT TO SCALE V LILIV 1 MOORE COUNTY wall vuvjon■ 444SIIO1G91W, rr«rmmEu GO L D E R DESIGN REVIEW DENSE � �`VEGETATI DENSE C— STREAM, POND, AND WETLAND LIMITS EXISTING 10 FT GROUND SURFACE CONTOUR EXISTING 2 FT GROUND SURFACE CONTOUR PROPERTY LINE APPROXIMATE LIMITS OF WASTE EXISTING ROAD 385 POTENTIOMETRIC GROUNDWATER CONTOURS (5 FT. INTERVAL) GROUNDWATER FLOW SEGMENTS MW-1 MONITORING WELL AND IDENTIFICATION '380.94 GP-10 METHANE PROBE AND IDENTIFICATION ❑ SW-1 SURFACE WATER MONITORING POINT AND IDENTIFICATION LANDFILL GAS TRENCH VENTS AND IDENTIFICATION m PASSIVE LANDFILL GAS VENTS 0 PW-1 PRIVATE WELL LOCATION AND IDENTIFICATION 4 WETLAND AREA SB-2 SOIL SAMPLE LOCATIONS PZ-2 PIEZOMETERS NOTES 1. TOPOGRAPHIC CONTOUR INTERVAL = 2 FEET 2. GROUNDWATER SURFACE CONTOUR INTERVAL = 5 FEET 3. GROUNDWATER ELEVATIONS MEASURED ON NOVEMBER 19, 2019. 4. GROUNDWATER CONTOURS BASED ON LINEAR INTERPOLATION BETWEEN AND EXTRAPOLATION FROM KNOWN DATA, TOPOGRAPHIC CONTOURS, AND KNOWN FIELD CONDITIONS. THEREFORE, GROUNDWATER CONTOURS MAY NOT REFLECT ACTUAL CONDITIONS. 5. GROUNDWATER CONTOUR LINES SHOW THE WATER TABLE SHAPE AND ELEVATION. THESE CONTOURS ARE INFERRED LINES FOLLOWING THE GROUNDWATER SURFACE AT A CONSTANT ELEVATION ABOVE SEA LEVEL. THE GROUNDWATER FLOW DIRECTION IS GENERALLY PERPENDICULAR TO THE GROUNDWATER SURFACE CONTOURS, SIMILAR TO THE RELATIONSHIP BETWEEN SURFACE WATER FLOW AND TOPOGRAPHIC CONTOURS. 6. PROPERTY BOUNDARY SURVEY BY JAMES L. WRIGHT DATED NOVEMBER 1984. ITS LOCATION IS RELATIVE TO TOPOGRAPHY APPROXIMATE BY HDR ENGINEERING, INC. 7. EXISTING TOPOGRAPHY WITHIN ACTIVE AND PROPOSED LANDFILL PROVIDED BY MATTHEWS LAND SURVEYING & MAPPING, PLLC DATED APRIL 17, 2015 AND JUNE 2018. 8. MONITORING WELLS MW-1 THROUGH MW-5 SURVEYED JUNE 1987 BY S&ME, INC. MONITORING WELLS MW-6 THROUGH MW-16 SURVEYED APRIL 1995, SEPTEMBER 1996, AND APRIL 2003 BY HDR ENGINEERING INC./ ED BUCKNER RLS APRIL 17, 2015. 9. THE LOCATIONS OF LANDFILL GAS TRENCH VENTS ARE APPROXIMATE. 10. GROUNDWATER WELLS MW-11 DR, MW-13D, AND MW-17D ARE NOT SCREENED IN THE SHALLOW AQUIFER AND ELEVATION DATA WERE NOT USED IN THE CONSTRUCTION OF GROUNDWATER CONTOURS. 0 200 400 SCALE FEET PROJECT MOORE COUNTY LANDFILL NC SOLID WASTE PERMIT NO. 63-01 ABERDEEN, MOORE COUNTY, NORTH CAROLINA TITLE GROUNDWATER SURFACE CONTOUR MAP NOVEMBER 19, 2019 PROJECT No. PHASE Rev. DRAWING 19127453 100 0 it II' 11 APPROVED RPK ENVIRO—EQUIPMENT, INC.. LANDTEC GEM 5000 Plus CALIBRATION DATA SHEET Serial Number (�SQ-1637 Date 3J& O Inspector Time/Date Battery Level Memory Cleared '� Pump Faults Gas Alarms: CHa = 100.0% CO2 = 100.0% OZ = 22.0% Zero Transducers v Pump Flow Rate _ 7 Vacuum Tested To 80" H2O !� Calibration Check (Performed at Room Temperature) Calibration Gas Calibration Gas Lot Number Expiration Reading Accuracy*, Concentration Pure NZ % (� O,. c� Q(� / 1 I• !� High CHy So/ l l9�'68S _� Se yo t2 High CO, 3 $°l� u 49 b$S 9 � f 2%% Low CHI L s y� ►`-� ti a ! s lb 2% Low CO2 t 2% �T^ t 2% o High OZ 20.9% N/A , N/A a o .9 l�_ t 10% co 5 19aga7 10% H2S 'Accuracy depends upon calibration range; 15%-FS range for CHa & CO2, 0-5% volume for O2, 0%-FS for H2S, and 10- of reading for CO. INSPECTOR'S MAINTENANCE NOTES EEI GEM 2000 Plus Cal Form 01/12