Loading...
HomeMy WebLinkAbout4501_Henderson_MSWLF_CDLF_March20LFG_FID1394768_20200324t—NR USE ONLY: I1 IJPJIP- R"Po'l OF Mctron;c; 0alA 1, mall (;I) ((tata loade(' fps r Nn) r)orA vent it C DLNR --T1 Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice INS f0im Rrxf Any infnrmAl ul alfached In II are -I"Ut)(IC Records As defined in NC (;eneral Sletute 132 1 Al 91N.►0 these dcxuments are Av-idahie for rnspeclmn And ewarnmallnn by any rwrson ulx)n request (NC: 61eneral �,leluln 132 (i) Instructions: prepare one form for each individually monitored unit. PfNe* type or print IApibly Attach a not►ficahon table mill values Thal ellam or exceed N(: 21 groundwater standards or NC 29 surface water standards The nr,Micatlon nHrft tncllide a prehmulery analysis of the cause and signifcance of each value to g naturally ocu►rnng off site s(►urce pre existing comblion Mc 1 Attach a notification tahte of any proundwater or surface water values Mill equal nr exceed the reporting limits Alfach a notification table of any methane g•+5 values that altain or exceed explosive gas levels This incAudes any structures on to ntart)y me facility (NCAC 131-1 1629 (4)(8)(1) Send the original signed and seaied form any tables and Electronic Dols Deliverable to Compliance Unit NCDENR-DIHM Solid Waste Sechon. 1646 Mad Service Center Raleigh NC 27699 1846 Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory• consultant, facility owner): Golder Asso( late,, NC, Inc. on behalf of Henderson County Contact for questions about data formatting. Include data preparees name, telephone number and E•mall address: Name David Y Reedy 11 E-mad dreedy0goider com---- Phone 336-852-4903 NC Landfill Rule Actual sampling dates re g Facrhty name Facility Address Facility Permit 0 ( 0500 or 1600) October 20-24 2006) Henderson County Closed Landfill 191 Transfer Station Drive 45-01 1600/0500 Marcri 17 2020 Hendersonville. NC 28791 i Environmental Status: (Check all that apply) inu C,ailBackground Monitoring Detection Monitoring Assessment Monitoring u Corrective Action Type of data submitted: (Check all that apply) Tf Groundwater monitoring data from monitoring wells �X Methane gas monitoring data Groundwater monitoring data from private water supply wells ❑ Corrective action data (specify) i_eachate monitoring data ❑ Surface water monitoring data Olher(specify) Notification attached? r,X; No No groundwater or surface water standards were exceeded Yes a notification of values exceeding a groundwater or surface water standard is attached It includes a list of groundwater and surface water mortilonng points dates analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration Yes a notification of values exceeding an explosive methane gas limit is attached It includes the methane monitoring points dates sample values and explosive methane gas limits. Certification To the test of my knowtedg-ii, tho Infoiiiation reported and statements made on this data submittal and attachments art true and correc► Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification Including the possibility of a fine and imprisonment David Y Reedy II, PG Senior Hydrogeologisl Facd entativeN LUP Printl Title 3 - Z Y-_Zou_ Signature Dale Goidef Associates NC Inc 5B Oak Branch Drive. Greensboro. NC 27407 Facility Representative Address C-2662 NC PE Firm License Number (if applicable effective May 1 2009) Revised 612009 336-852-4903 (Area Code) Telephone N,,-.:Lir4yl Affix NC Lawimaii d U Seal G GOLDER March 24, 2020 Ms. Jaclynne Drummond, Hydrogeologist North Carolina Department of Environmental Quality Division of Waste Management - Solid Waste Section 2090 US Highway 70 Swannanoa, North Carolina 28778 828-296-4706 jaclynne.drummond@ncdenr.gov METHANE MONITORING RESULTS — FIRST QUARTERLY EVENT OF 2020 CLOSED HENDERSON COUNTY LANDFILL, PERMIT NO. 45-01 HENDERSON COUNTY, NORTH CAROLINA Dear Jackie, 19128179.203 Attached are the results from the March 17, 2020, first quarterly methane monitoring event conducted at the above -referenced facility. As shown on the attached Boundary Gas Probe Monitoring Log, methane was not detected above the lower explosive limit (LEL) in any compliance methane monitoring points but was detected above the LEL in two assessment methane monitoring points (TR-2 and TR-3) during the event. No methane was detected in the facility structures during this compliance monitoring event. If you have any questions or concerns, please contact us at 336-852-4903. Sincerely, Golder Associates NC, Inc. David "Dusty" Y. Reedy II, PG Senior Hydrogeologist Golder Associates NC, Inc. 5B Oak Branch Drive, Greensboro, North Carolina, USA 27407 Engineering Lic. No. C-2862/Geology Lic. No. C-399 Rachel P. Kirkman, PG Associate and Senior Consultant T: +1 336 852-4903 F: +1 336 852-4904 Golder Associates NC, Inc. is a licensed user of the Golder trademark, and an associated operating entity. Golder and the G logo are trademarks of Golder Associates Corporation. goider.com Ms. Jaclynne Drummond, Hydrogeologist North Carolina Department of Environmental Quality CC: Marcus Jones, PE, Director of Engineering, Henderson County, 1 Historic Courthouse Square, Suite 6, Hendersonville, NC 28792. 828-694-6560. majones@hendersoncountync.org Greg Wiggins, Operations Manager, Henderson County, 191 Transfer Station Drive, Hendersonville, North Carolina 28791. 828-694-7982. gwiggins@hendersoncountync.org Attachments: Boundary Gas Probe Monitoring Log — March 17, 2020 Cut-off Trench LFG Vent Monitoring Log — March 17, 2020 Methane Monitoring Location Map Calibration Record gAprojects\henderson county\19128179\phase 203 - 1st qtr Ifg 2020\19128179.203-r-001-rev0-1st_gtr_Ifg_rpt.docx 19128179.203 March 24, 2020 4 GOLDER NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in PVC General Statute 132-1. As such, these documents are available fa- inspection and examination by any person upon request (jVC General Statute t 32-6). Facility Name: Henderson County Landfill Sampling Date: 03/1 7/20 Sample Collector Name & Position: Gas Meter Type & Serial Number: Field Calibration Date & Time: Number: 45-01 Landfill Rule (.0500 or. 1600): T. Martinez, Environmental Scientist GEM 2000+ 03/17/20 12:37 Gas Meter calibration Date: 03/04/20 Field Calibration Gas Type (15115 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 2/21 /21 Gas Meter Pump Rate: 300 cc/min Ambient Air Temperature: 570E Barometric Pressure (in. or mm Hg): 27*95" Weather Conditions: Fair, Winds Omph Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well [D Sample Tube Purge Time of Day Time Pumped P (sec) Initial o /o LEL Stabilized o /o LEL % CH4 (volume) 0 /0 02 (volume) 0 /o CO2 (volume) o M /o H2S' (volume) NOTES MP-1 14:35 60 0 0 0.0 18.7 2.1 1 MP-3 14:19 60 4 4 0.2 15.1 3.6 0 MP-4 14:15 60 0 0 0.0 19.9 0.4 0 MP-7 13:31 60 0 0 0.0 12.7 5.4 0 MP-8 13:27 60 0 0 0.0 20.2 0.4 1 0 MP-9 13:23 60 0 0 0.0 18.8 2.0 0 Activity Building 13:12 60 0 0 0.0 20.8 0.0 0 Animal Shelter 12:51 60 0 0 0.0 21.0 0.1 0 Break House 13:06 60 0 0 0.0 20.8 0.0 0 Bus Garage 12:46 60 0 0 0.0 21.1 0.1 0 Convenience Center 12:42 60 0 0 0.0 21.2 0.1 0 'The Landtec GEM 2000+ has a Maintenance Shop 13:02 1 60 0 0 0.0 20.8 0.0 O CH4 accuracy range of +/- 0.3% NOTE: if needed, attach additional data forms to include additional LFG monitoring data locations for the facithy. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1% by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Environmental Scientist SIGNATURE TITLE Revised - March 6, 2017 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This farm and any information attached to it are "Public Records"as defined in NC General Statute 132-1. As such, these documents are available for inspection and exatnination by any person upon request (NC General Statute 132-6). Facility Name: Henderson County Landfill rmit Number: 45-01 Sampling Date: 03/1 7/20 NC Landfill Rule (.0500 or.1600): Sample Collector Name & Position: Gas Meter Type & Serial Number: Field Calibration Date & Time: T. Martinez, Environmental Scientist GEM 2000+ 03/17/20 12:37 Gas Meter Calibration Date: 03/04/20 Field Calibration Gas Type (15115 or 35/50): 1 5/1 5 Field Calibration Gas Canister Expiration Date: 2/21 /21 Gas Meter Pump Rate: 300 cc/min Ambient Air Temperature: 57o F Barometric Pressure (in. or min Hg): 27'95" Weather Conditions: Fair, Winds Omph Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID S ample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized % LEL % CH4 volume (volume) % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES Scalehouse 12:56 60 0 0 0.0 20.8 0.1 0 Trace Barn 13:19 60 0 0 0.0 20.8 0.0 0 MP-6 13:49 60 0 0 0.0 20.6 0.2 0 TR-2 13:42 60 106 106 5.3 16.0 7.5 0 TR-3 14:27 60 306 306 15.3 14.0 10.2 0 LFG-101 14:51 60 0 0 0.0 20.6 0.1 0 LFG-102 14:47 60 0 0 0.0 18.0 1.6 0 LFG-103 14:42 60 0 0 0.0 14.8 5.2 0 .The Landtec GEM 2000+ has a CH4 accuracy range of +/- 0.3% NOTE: if needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Environmental Scientist SIGNATURE TITLE Revised — March 6, 2017 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request ONC General Statute 132-6). Facility Name: Henderson County Landfill rmit Number: 45-01 Sampling Date: 03/1 7/20 NC Landfill Rule (.0500 or. 1600): Sample Collector Name & Position: T. Martinez, Environmental Scientist Gas Meter Type & Serial Number: Field Calibration Date & Time: GEM 2000+ 03/17/20 12:37 Field Calibration Gas Type (15/15 or 35/50): Gas Meter Pump Rate: 300 cc/min 15/15 Gas Meter Calibration Date: 03/04/20 Field Calibration Gas Canister Expiration Date: 2/21 /21 Ambient Air Temperature: 570 F Barometric Pressure (in. or mm Hg): 27*95" Weather Conditions: Fair, Winds Omph Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions andlor Facility LFG monitoring plan. Location or LFG Well ID S ample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized % LEL % CH4 volume (volume) % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES Cut-off Trench Vent 1 14:08 60 158 158 7.9 2.7 17.0 0 Cut-off Trench Vent 2 14:05 60 56 56 2.8 7.8 9.0 0 'The Landtec GEM 2000+ has a CH4 accuracy range of +/- 0.3% NOTE: /f needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1% by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Environmental Scientist SIGNATURE TITLE Revised — March 6, 2017 r TRACE BARN EW 2 EW�EW a Q 1 ❑ Ci1T-OFF TRENCH VENT 2 - PA \ [ Alf 6 28 ❑2 W. ❑ 5 � u� V I 7 1 CLOT CUT-OFF TRENCH VENT 1 E Ew- 7 t E - , gEMOLI LANDFILL, CLO VI ATEMP 1 L DOSED C6 f 4 ' AST Hi E f o i �3 Ew - , ❑ to 1 r I LOSE e EANON , E / o MP-3 -45 W- w' P j ❑EW-I9 , ti dd❑ 199t r 4 PRIVAT ROPE LEGEND EXISTING 10 FT, CONTOUR EXISTING 2 FT. CONTOUR — - - — PROPERTY LINE — — — LIMITS OF WASTE STREAM BUFFER •'^^^^'^+ 7REELINE EXISTING ROAD FENCE -----,------ LFG COLLECTION PIPING ......... LFG CUT-OFF TRENCH Mw•8 COMPLIANCE MONITORING WELL s mw-1 NON COMPLIANCE MONITORING WELLS . MP-6 COMPLIANCE METHANE MONITORING WELLS A MP8 ASSESSMENT METHANE MONITORING WELLS ❑ BRA SURFACE WATER MONITORING POINT Q EVV-29 LFG EXTRACTION WELL CONVERTED TO PASSIVE VENTING NOTES 1. TOPOGRAPHIC CONTOUR INTERVAL = 2 FEET 2. COORDINATE SYSTEM IS N.C. STATE PLANE GRID. 3. TOPOGRAPHIC DIVIDING LINE DIVIDES THE SASE MAP TOPOGRAPHIC CONTOURS FROM LANDSAT TOPOGRAPHIC CONTOURS. LANDSATTOPOGRAPHICCONTOLRSHAVCASCONTOUR INTERVAL. 4. RECORDS WERE UNABLE TO BE LDCATED FOR LFG EXTRACTION WELLS EW-XI THROUGH EW-Xi AND WERE GIVEN IDENTIFICATION NAMES UNTIL SUCH TIME THAT RECORDS ARE FOUND. 5. LOCATION OF CCMFLIANCE METHANE MONITORING WELL MP-4 ISAPPROXIMATE. REFERENCE I. BASE MAP PROVIOEO BY CAMP DRESSER & MCKEE FROM PREVIOUS wATER QUALITY MONITORING REPORTS. 2. WELLS MP-?, MPS, AND MP-R WERE SURVEYED BY REGIONAL LAND SURVEYING. INC. ON JUNE 1 T. 2C T5. L SITELOCATIONAP N TO S D 150 300 SCALE FEET PRCJECT HENDERSON COUNTY HENDERSON COUNTY CLOSED MSVV AND C&D LANDFILL ����CLIENT ���::::::PERMIT#45-01 �_ONSULTANTPG C-399 YYYY-MM•DD 2G16.09.12 717— _ METHANE MONITORING LOCATION MAP �v PREPARED MAK s G a L D E R DESIGN DYR REVIEW DYR PROJECT No. DRAVUk- GOLDER ASSOCIATES NC, INC. APPROVED RPK 08396506 1 INSTRUMENT CALIBRATION REPORT Pine Environmental Services LLC 92 North Main St, Building 20 Windsor, NJ 08561 Toll -free: (800) 301-9663 Pine Environmental Services, Inc. Instrument ID R11083 Description Gem 2000+ Calibrated 3/4/2020 1:43:02PM Manufacturer CES Landtec State Certified Model Number GEM2000+ Status Pass Serial Number/ Lot GM10443 Temp °C 23.9 Number Location New Jersey Humidity % 19 Department Calibration Specifications Group # 1 Range Ace % 0.0000 Group Name Methane Reading Ace % 3.0000 Stated Accy Pct of Reading Plus/Minus 0.0 Nom In Val / In Val In Type Out Val Out Type Fnd As Lft As Dev% Pass/Fail 50.0/50.0 %Volume 50.0 %Volume 49.9 50.0 0.00% Pass Group # 2 Range Ace % 0.0000 Group Name Carbon Dioxide Reading Ace % 3.0000 Stated Accy Pct of Reading Plus/Minus 0.0 Nom In Val / In Val In Type Out Val Out a Fnd As Lft As Dev% Pass/Fail 35.0/35.0 %Volume 35.0 %Volume 34.8 35.0 0.00% Pass Group # 3 Range Ace % 0.0000 Group Name Oxygen Reading Ace % 3.0000 Stated Accy Pct of Reading Plus/Minus 0.0 Nom In Val / In Val In Type Out Val Out Tvpe Fnd As Lft As Dev% Pass/Fail 20.9/20.9 %Volume 20.9 %Volume 20.8 20.9 0.00% Pass Group # 4 Range Ace % 0.0000 Group Name Hydrogen Sulfide Reading Ace % 3.0000 Stated Accy Pct of Reading Plus/Minus 0.00 Nom In Val / In Val In Type Out Val Out Type Fnd As Lft As Dev% Pass/Fail 25.00 / 25.00 PPM 25.00 PPM 24.70 25.00 0.00% Pass Group # 5 Range Ace % 0.0000 Group Name Carbon Monoxide Reading Ace % 3.0000 Stated Accy Pct of Reading Plus/Minus 0.0 Nom In Val / In Val In Type Out Val Out Type Fnd As Lft As Dev% Pass/Fail 50.0 / 50.0 PPM 50.0 PPM 49.9 50.0 0.00% Pass Pine Environmental Services LLC Windsor Industrial Park, 92 North Main Street, Bldg 20, Windsor, NJ 08561, 800-301-9663 www.pine-environmental.com INSTRUMENT CALIBRATION REPORT Pine Environmental Services LLC 92 North Main St, Building 20 Windsor, NJ 08561 Toll -free: (800) 301-9663 Pine Environmental Services, Inc. Instrument ID R11083 Description Gem 2000+ Calibrated 3/4/2020 1:43:02PM Test Instruments Used During the Calibration (As Of Cal Entry Date) Serial Number / Next Cal Date / Test Standard ID Description Manufacturer Model Number Lot Number Last Cal Date/ Expiration Date Opened Date NJ NJ 50% CH4, 35%CO2 Liquid 31808 IBI-399-4 11/7/2022 50%CH4/35%C 105 LITERS- Technology 02 - IBI-399-4 IBI-399-4 NJ CO 1000/ NJ CO 1000/ H2S 50 - Pine 32278 983987 7/l/2020 H2S 50 - 983987 983987 Environmental Services, Inc. NJ CO2 / CH4 - CH4 AND CO2 Pine 31808 KAP-399-1 8/19/2016 8/19/2017 -b05L- KAP-399-1 Environmental CAP7399-1 Services, Inc. Notes about this calibration Calibration Result Calibration Successful Who Calibrated Martin Konn All instruments are calibrated by Pine Environmental Services LLC according to the manufacturer's specifications, but it is the customer's responsibility to calibrate and maintain this unit in accordance with the . manufacturer's specifications and/or the customer's own specific needs. Notify Pine Environmental Services LLC of any defect within 24 hours of receipt of equipment Please call 800-301-9663 for Technical Assistance Pine Environmental Services LLC Windsor Industrial Park, 92 North Main Street, Bldg 20, Windsor, NJ 08561, 800-301-9663 www.pine-environmental.com