Loading...
HomeMy WebLinkAbout6301_Moore_MSWLF_CDLF_LFG_FID1390369_20200224I pENR USE ONLY ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #: NC DENR I IEnvironmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source: pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Golder Associates NC, Inc. (on behalf of Moore County) Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Benjamin S. Draper, PG Phone: 336-852-4903 E-mail: bdraper@golder.com NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) Moore County Landfill 456 Turning Leaf Way 63-01 .0500 February 17, 2020 Aberdeen, NC 28315 Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring ❑ Detection Monitoring Assessment Monitoring �X Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells �R Methane gas monitoring data Groundwater monitoring data from private water supply wells F1 Corrective action data (specify) Leachate monitoring data Surface water monitoring data Other(specify) Notification attached? e No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard. NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. �X Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Benjamin S. Draper, PG Senior Project Geologist 336-852-4903 Facility Regr�itative Name title CZ-2Y— 2D Date Golder Associates NC, Inc., 5B Oak Branch Drive, Greensboro, NC 27407 Facility Representative Address PE C-2862; PG C-399 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 (Area Code) Telephone Number Affix NC LicensecU CAR = 33 % �`'o��►'�i'*%OL OG�S S V�•�a �044000 Seal NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Moore County Landfill Permit Number: 63-01 Sampling Date: 2/17/20 NC Landfill Rule (.0500 or.1600): Sample Collector Name & Position: Erik Vasko Gas Meter Type & Serial Number: GEM 5000 Field Calibration Date & Time: 2/17/20 15:02 0500 Gas Meter Calibration Date: 2/14/20 Field Calibration Gas Type (15115 or35/50): 15/15 Field Calibration Gas Canister Expiration Date: 2/21 /21 Gas Meter Pump Rate: 300 cc/min 61 OF 29.96 Fair, winds E at 7mph Ambient Air Temperature: Barometric Pressure (in. or min Hg): Weather Conditions: Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to %LEL as follows: % methane (by volume)/20 = %LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID S ample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized LEL % % CH4 ( volume ) % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES MW-6 60 15:42 60 238 238 11.9 15.0 6.9 0 2 Inch Groundwater Well MW-15 60 15:50 60 562 562 28.1 9.7 18.6 1 2Inch GroundmterWell converted tomethane probe GV-33 (Eastern Vent) 60 15:45 1 60 718 718 35.9 BDL 32.2 0 Gas Vent GV-34 (Western Vent) 60 15:44 60 0 0 0.3 20.6 0.4 0 Gas Vent SCALEHOUSE 60 15:26 90 0 0 1 0.0 20.8 0.0 0 Building Maintenance Shop 60 15:33 90 0 0 0.0 20.7 0.0 0 Building Transfer station 60 15:30 1 90 0 0 0.0 20.8 0.0 1 0 Building &�eRe�den�t� spevt 60 15:08 90 0 0 0.0 21.0 0.0 0 Building ` The Landtec GEM 5000 has a CH4 accuracy range of +/- 0.3 % NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1% by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for malting any false statement, representation, or certiAotion including a possibility of a fine and imprisonment. Geologist SIGNATURE ER 1 K AS KD TITLE Revised — March 6, 2017 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Moore County Landfill Permit Number: 63-01 Sampling Date: 2/17/20 NC Landfill Rule (.0500 or.1600): •0500 Sample Collector Name & Position: Erik Vasko Gas Meter Type & Serial Number: GEM 5000 Field Calibration Date & Time: 2/17/20 15'02 Gas Meter Calibration Date: 2/14/20 Field Calibration Gas Type (15/15 or35/50): 15/15 Field Calibration Gas Canister Expiration Date: 2/21 /21 Gas Meter Pump Rate: 300 cc/min Ambient Air Temperature: 61 OF Barometric Pressure (in. or min Hg): 29.96 Weather Conditions: Fair, winds E at 7mph Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID S ample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized /o LEL % CH4 (volume) % 02 (volume) % CO2 (volume) % H2S" (volume) NOTES GP-9 60 16:37 60 0 0 0.0 21.6 0.0 0 1 Inch Well GP-10 60 16:26 60 374 374 18.7 5.3 11.8 0 1 Inch Well GP-11 60 16:31 60 0 0 0.0 20.4 1.0 0 1 Inch Well GP-12 60 15:37 60 0 0 0.0 20.5 0.0 0 1 Inch Well GP-13 60 16:20 60 0 0 0.0 20.7 0.7 0 1 Inch Well GP-13R 60 16:16 60 1 0 0 0.0 1 20.9 0.5 0 1 1 Inch Well GP-14 60 16:13 60 0 0 0.0 18.2 2.3 0 1 Inch Well GP-14R 60 16:11 60 0 0 0.0 19.0 1.2 0 1 Inch Well GP-15 60 16:02 60 0 0 0.0 16.5 1.9 0 1 Inch Well GP-15R 60 16:08 60 0 0 0.0 20.7 0.4 0 1 Inch Well GP-16 60 15:59 60 0 1 0 1 0.0 15.6 5.9 0 1 1 Inch Well GP-17 1 60 15:54 60 0 0 0.0 1 18.8 0.7 0 1 Inch Well NOTE: /f needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1% by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, ;;M;;� ty of a fine and imprisonment. � Geologist SIGNAT C4Z) /C V>AS ►CC) TITLE Revised - March 6, 2017 LEGEND SW-2 [']� l�\ DENSE GETATION ,I DENSE VEGETATION I \ DENSE VEGETATION I` DENSE GETATION GROUND OBSCURED DENSE VEGETATION SEE ACCURACY NOTE \ DE VEGETATION GROUND OBSCURED SEE ACCURACY NOTE SITE LOCATION MAP NOT TO SCALE V LILIV 1 MOORE COUNTY wall vuvjon■ 444SIIO1G91W, rr«rmmEu GO L D E R DESIGN REVIEW DENSE � �`VEGETATI DENSE C— STREAM, POND, AND WETLAND LIMITS EXISTING 10 FT GROUND SURFACE CONTOUR EXISTING 2 FT GROUND SURFACE CONTOUR PROPERTY LINE APPROXIMATE LIMITS OF WASTE EXISTING ROAD 385 POTENTIOMETRIC GROUNDWATER CONTOURS (5 FT. INTERVAL) GROUNDWATER FLOW SEGMENTS MW-1 MONITORING WELL AND IDENTIFICATION '380.94 GP-10 METHANE PROBE AND IDENTIFICATION ❑ SW-1 SURFACE WATER MONITORING POINT AND IDENTIFICATION LANDFILL GAS TRENCH VENTS AND IDENTIFICATION m PASSIVE LANDFILL GAS VENTS 0 PW-1 PRIVATE WELL LOCATION AND IDENTIFICATION 4 WETLAND AREA SB-2 SOIL SAMPLE LOCATIONS PZ-2 PIEZOMETERS NOTES 1. TOPOGRAPHIC CONTOUR INTERVAL = 2 FEET 2. GROUNDWATER SURFACE CONTOUR INTERVAL = 5 FEET 3. GROUNDWATER ELEVATIONS MEASURED ON NOVEMBER 19, 2019. 4. GROUNDWATER CONTOURS BASED ON LINEAR INTERPOLATION BETWEEN AND EXTRAPOLATION FROM KNOWN DATA, TOPOGRAPHIC CONTOURS, AND KNOWN FIELD CONDITIONS. THEREFORE, GROUNDWATER CONTOURS MAY NOT REFLECT ACTUAL CONDITIONS. 5. GROUNDWATER CONTOUR LINES SHOW THE WATER TABLE SHAPE AND ELEVATION. THESE CONTOURS ARE INFERRED LINES FOLLOWING THE GROUNDWATER SURFACE AT A CONSTANT ELEVATION ABOVE SEA LEVEL. THE GROUNDWATER FLOW DIRECTION IS GENERALLY PERPENDICULAR TO THE GROUNDWATER SURFACE CONTOURS, SIMILAR TO THE RELATIONSHIP BETWEEN SURFACE WATER FLOW AND TOPOGRAPHIC CONTOURS. 6. PROPERTY BOUNDARY SURVEY BY JAMES L. WRIGHT DATED NOVEMBER 1984. ITS LOCATION IS RELATIVE TO TOPOGRAPHY APPROXIMATE BY HDR ENGINEERING, INC. 7. EXISTING TOPOGRAPHY WITHIN ACTIVE AND PROPOSED LANDFILL PROVIDED BY MATTHEWS LAND SURVEYING & MAPPING, PLLC DATED APRIL 17, 2015 AND JUNE 2018. 8. MONITORING WELLS MW-1 THROUGH MW-5 SURVEYED JUNE 1987 BY S&ME, INC. MONITORING WELLS MW-6 THROUGH MW-16 SURVEYED APRIL 1995, SEPTEMBER 1996, AND APRIL 2003 BY HDR ENGINEERING INC./ ED BUCKNER RLS APRIL 17, 2015. 9. THE LOCATIONS OF LANDFILL GAS TRENCH VENTS ARE APPROXIMATE. 10. GROUNDWATER WELLS MW-11 DR, MW-13D, AND MW-17D ARE NOT SCREENED IN THE SHALLOW AQUIFER AND ELEVATION DATA WERE NOT USED IN THE CONSTRUCTION OF GROUNDWATER CONTOURS. 0 200 400 SCALE FEET PROJECT MOORE COUNTY LANDFILL NC SOLID WASTE PERMIT NO. 63-01 ABERDEEN, MOORE COUNTY, NORTH CAROLINA TITLE GROUNDWATER SURFACE CONTOUR MAP NOVEMBER 19, 2019 PROJECT No. PHASE Rev. DRAWING 19127453 100 0 it II' 11 APPROVED RPK LU a u LL LU u L o � N LLI M 0 LV O� L O to N J 0 -O O Lru U 4-0 _ E C O a� E Z L id 4-1 N 75 �EEEE O 75 75 G E >>Q _o 0 M � O N _ ca CD d d d _ > > c > a ■� o o o LO N M O O (J) 0 = cV I = U