Loading...
HomeMy WebLinkAboutMO-5714_20117_CA_MRP_20200212_Sampling Results Letter Report,SHIELD ENGINEERING, INC. February 12, 2020 Ms. Trudy Beverly, L.G. NCDEQ - Mooresville Regional Office 601 East Center Street, Suite 301 Mooresville, NC 28115 Ref: Monitoring and Water Supply Well Sampling Results Carolina Fast Mart #2 5104 North Highway 49 Concord, Cabarrus County, North Carolina Groundwater Incident No. 20117 Shield Project 1990047 Dear Ms. Beverly: Shield Engineering, Inc. (Shield) personnel, on behalf of Carolina Oil Company, mobilized to the Carolina Fast Mart #2 site on November 5, 2019 to obtain the monitoring and water supply well samples required to be collected per the North Carolina Department of Environmental Quality (NCDEQ) Notice of Regulatory Requirements (NORR) letter dated August 27, 2019. During our site visit, samples were collected from monitoring wells MW-4 and MW-5 as well as water supply well WSW-lA as requested in the NCDEQ NORR. Figure 1 illustrates the site layout and monitoring well locations. The locations of the area water supply wells are illustrated on the 1,500- foot radius map presented as Figure 2. Monitoring well and groundwater information can be seen in Table 1. The laboratory analytical data for the samples collected on November 5, 2019 from the sampled wells are summarized in Table 2. The laboratory analytical data for the sample collected from MW-5 showed a naphthalene concentration of 7.2 micrograms per liter (ug/L) which is 1.2 ug/L above the North Carolina Administrative Code (NCAC), 15A 2L Class GA Standards (21, Standards) of 6 ug/L for that constituent. No other constituent concentration exceeded the 2L Standards in MW-4 or MW-5. The analytical results for the WSW -IA show that no constituent concentrations exceeded the 2L Standards. A copy of the laboratory analytical report for the November 5, 2019 sampling event is presented in Appendix A. The oxygen released compound (ORC) socks in MW-4 and MW-5 that were installed during the November 2018 sampling event were removed. The NCDEQ has not approved replacement of the ORC Socks. The monitoring and water supply wells were scheduled to be sampled again in May 2020. Due to the site's groundwater constituent concentrations being so close to being below the 2L Standards, Shield recommends sampling MW-4, MW-5, and WSW- IA in the first quarter of 2020. Whm all of the results are below the 2L Standards, we will request a no further action from the NCDEQ. Please let Shield know if the NCDEQ concurs with this approach. 4301 Taggart Creek Road Telephone 704.394.6913 Charlotte, NC 28208 www.shieldengineering.com Fax 704.394.6968 Carolina Fast Mart #2 Concord, Cabarrus County, North Carolina Monitoring and Water Supply Well Sampling Results February 12, 2020 Page 2 If you should have any questions, please contact the undersigned at (704) 394-6913. Sincerely, Shield Engineering, Inc. Kevin P. Stachura Project Manager David A. Stoner, P CG::�?. C. Senior Principal Registered, NC # 1427' H:\Projects\1999\1990047 CFM#2\Reports\2019-11 LTR Report\Sampling Results Letter Report February 2020.doc SHIELD FIGURES LEGEND: DRAINAGE FEATURE — — — NCDOT RIGHT OF WAY #— — POLE LOCATIONS, OVERHEAD ELECTRICAL POWER — sD— 9D— STORM DRAIN + WSw—I T (OUT -OF -USE) /_—POI•ER SUPPLY 1'0 NU / p / Pom SUPPLY " umm 1 / I / I UNDERGROUND ELECTRICAL LUM —/ — — — — — — — — I MW-8 9 POIf� SUPPLY TO uCR79 \ DDIFENSI tS UNDERGROUND EI MOMCAL LUM socE or Pevnonat' — — — — / / N" UST UNDERGROUND AREA FMZRGLAN / PRODUCT LIN I I OseNrrARr satrmt oQ MW-0 I 5B1 I MW-3 6I � I / APPRMMIAT'E YOM=:UST ARRA 11 1 � SB6+:: '. STORE ` 49 FAST MART #2 5B5 ` _''iEr� + a o ❑ I SB4+ MW 1 I ! `'�`T-1 � �• 'all + SB2 , or IS4 mroaoam aL�sxsBR I + MW,7 '-1 MW-5 !9 • S83 s MW-4 �MW 10 r� l D1 + D2 • CAROPY • D3 : 1 I I _..——..—..—..—....._ ..—,- � BMW-6A �W'� I i — -- — — .............. < ................. RIGHT OF WAY —X MW 2 — — — — jKm 6 T- NC HIGHWAY 49 EAST MW-12 - SD - SD - SD - SD - SD - SD - SD -MSa.0 SD - SD - SD - SD - SD - SD SD -- NC HIGHWAY 49 WEST _ — — — — — RIGHT OF WAY SW-B MW-11A DRJ�t �r r d GASOLINE UST (10,000 GALLONS) MONITORING WELL LOCATIONS ABANDONED MONITORING WELL LOCATIONS MANHOLE FOR SANITARY SEWER SOIL BORINGS ATTEMPTED SOIL BORINGS WATER SUPPLY WELL STREAM SAMPLE LOCATION CATCH BASIN O 14 NOTE: ALL LOCATIONS ARE APPROXIMATE. 0 I z �l a o a w 0I 0I a GRAPHIC SCALE 0 10 20 30 40 SCALE: 1 in. = 40 ft. 1,500' RADIUS #1790 _ #1800 #1824 J'7O8 #1826 >642 # 1948 #5250 � #5230 0 r�r fa'J #5170049 #1930 Q/� #5120 � WSW-5 Gt380 WSW-7 CFM N2 rl�p #4811 SIT/E ,f WSW-1A #2143 ZZJ7 WSW-2 #14788 `><? 500' RADIU - WSW-3 �f'f3 #2175 Q 0. #2174 �f+ .4 �. #2245 4 �G' �e �.�7J fil�L #2242 a �O #2265 LEGEND: ''Jt% & JC--.! PARCEL ID NUMBER 1,i100' RADI�s_ #2262 #2317 4301 TAGOMTUiEEKRpN) CIIMLOTTE. NC ewe SHIELD MI 3w-cnu #2143 ADDRESS NUMBER m ^3" wee w ENGINEERING, INC.El ® CFM (CAROLINA FAST MART #2) WATER SUPPLY WELL #2320 NO ONE HOME DURING RECEPTOR SURVEY �'�^t�� �7 0 ?� I 1 500 FOOT RADIUS MAP SERVED BY WATER SUPPLY WELL #2498 Y ® SITE LOCATION #2346 CAROLINA FAST MART #2 CONCORD, NORTH CAROLINA GRAPHIC SCALE SHIELD # 1990047 NOTES: 1- REFERENCE: PROPERTY INFORMATION OBTAINED FROM CABARRUS COUNTY GIS. Jr' #2407 y\� #2400 o iqo z 5 aqo DATE 12112 / 11 DRAWN BY : RBS 2- ALL LOCATIONS ARE APPROXIMATE. 3- WELL INFORMATION IS PROVIDED IN THE CSA REPORT. #2411 �O �'-�� ;-'' 4- RECEPTOR UPDATE COMPLETED ON 12/13/11. 1,500' RADIUS scALE: 1 . = 300 ft. SCALE : AS SHOWN FIGURE: 2 TABLES Table 1: Summary of Well Construction and Historical Groundwater Elevation Data Carolina Fast Mart #2 5104 Noth Highway 49, Concord, Cabarrus County, North Carolina NCDENR GWI #: 20117 Well ID Date Installed Top of Casing Elevation (feet) As -built Depth (feet) Screened Interval (feet) Field Measurements Field Calculations Gauging Date Total Depth (feet) Depth to Static Water (feet) Diff. Between As -Built and Measured Total Depth (feet) Measured Water Column in Well (feet) Ground -water Elevation (feet) MW-1 11l18/1999 10516 15 3-15 7/20/2000 NA 5.49 NA NA 9967 10/11/2000 NA 5.96 NA NA 9920 3/22/2001 NA 3.51 NA _ NA 10165 10/24/2001 NA 5,76 NA NA 9940 4/2/2002 NA 4.43 NA NA 10073 10/11/2002 NA 6,26 NA NA 98.90 1/10/2003 1 14.55 2.96 OA5 11,59 102,20 4/16/2003 14.67 1,98 0,33 12,69 10318 7/2/2003 14.67 2,05 0.33 12.62 103 11 4/16/2004 1467 2.99 0.33 11.68 102.17 5/31/2007 1467 4.12 0.33 10.55 101,04 11/29/2007 1467 6.45 0,33 1 8.22 98,71 5/19/2008 14 81 3.14 0.19 11,67 102.02 11/25/2008 147 3.83 03 10.87 101.33 6/4/2009 14 7 3.17 0.3 11.53 101 99 11/24/2009 NA 2,66 NA NA 102.50 3/4/2011 1469 3.16 0.31 11.84 102.00 12/13/2011 14.69 3.17 0.31 11.52 1O1.99 5/25/2012 1469 3.23 0,31 11.46 101.93 11/7/2012 1474 4,78 0,26 9.96 10038 5/22/2013 1474 3,15 0.26 11,59 10201 11/18/2013 14.74 3 81 0,26 10,93 101 35 5/13/2014 14.74 2.55 0.26 12,19 10261 11/14/2014 14.74 5 0,26 974 100,16 5/21/2015 14.74 3.08 0.26 11 66 10208 11/20/2015 NM - Not Required b NCDEQ MW-2 2/23/2000 10644 15 5-15 7/20/2000 NA 6.77 NA NA 9967 10/11/2000 NA 5.21 NA NA 101.23 3/22/2001 NA 4.65 NA NA 10179 10/24/2001 NA 5.30 NA NA 101.14 4/2/2002 NA 4.63 NA NA 101.81 ABANDONED MN'-3 1 1l18/1999 102 68 20 5-20 7/20/2000 NA 4,80 NA NA 97,88 10/11/2000 NA 5.49 NA NA 97.19 3/22/2001 NA 3.57 NA NA 99,11 10/24/2001 NA 5,92 NA NA 96,76 4/2/2002 NA 4.99 NA NA 97,69 10/11/2002 NA 6.69 NA NA 95.99 1/10/2003 19.61 2.47 0.39 1714 100.21 4/16/2003 19.85 1.11 0.15 18.74 101.57 7/2/2003 19 85 2.08 0.15 1777 100,60 4/13/2004 19.85 2,41 0,15 17.44 100.27 6/4/2009 19.85 239 0.15 1746 100.29 11/24/2009 NA 1.73 NA NA 100,95 3/24/2011 19.84 2,42 0.16 17.42 100.26 12/13/2011 19.84 2.27 0.16 17.57 100,41 5/25/2012 19 84 2.57 0.16 17.27 1 00. 11 11/7/2012 21.81 4,25 1,81 17,56 98.43 5/22/2013 21 81 2,42 1.81 19.39 1OQ26 11/18/2013 21.81 3,05 1.81 18.76 99.63 5/13/2014 21 81 1.63 1 81 2018 101,05 11/14/2014 2181 2.66 1.81 1915 100,02 5/21/2015 21 81 2 23 1.81 1958 100,45 11/20/2015 NM - Not Required by NCDEQ H PROJECT5119990990047ORMR 5-16Table 1 -Well Construction & Hislorical GW Elevation Page I of6 Table 1: Summary of Well Construction and Historical Groundwater Elevation Data Carolina Fast Mart #2 5104 Noth Highway 49, Concord, Cabarrus County, North Carolina NCDENR GWI #: 20117 Well ID Date Installed Top of Casing Elevation (feet) As -built Depth (feet) Screened Interval (feet) Field Measurements Field Calculations Gauging Date Total Depth (feet) Depth to Static Water (feet) Diff. Between As -Built and Measured Total Depth (feet) Measured Water Column in Well (feet) Ground -water Elevation (feet) MW-4 2/24/2000 10544 15 5-15 7/20/2000 NA 8.15 NA NA 97.29 10/11/2000 NA 8.35 NA NA 9709 3/22/2001 NA 6.66 NA NA 98.78 10/24/2001 NA 8,05 NA NA 97.39 4/2/2002 NA 6.75 NA NA 98,69 10/11/2002 NA 8 55 NA NA 96.89 1/10/2003 14.64 6.64 0.36 8.00 98.80 4/16/2003 14,90 5.85 0.1 9.05 99,59 7/2/2003 14.90 635 0.1 8.55 99.09 4/13/2004 14.90 6.7 0.1 8,20 98-74 5/31/2007 14.90 7.16 0.1 7.74 98.28 11/29/2007 14.90 8 86 0,1 6.04 96,58 5/19/2008 14 92 641 0,08 8,51 99.03 11/25/2008 149 6 86 0.1 8.04 98,58 6/4/2009 149 646 0 1 844 98 98 11/24/2009 NA 5.91 NA NA 99 53 3/4/2011 149 6.05 0 1 8 85 99 39 12/13/2011 14.88 6 53 0 12 8.35 98 91 5/25/2012 1 14 88 6.56 0 12 8.32 98.88 11/7/2012 14.94 7.54 0.06 7.40 9790 5/25/2013 i 14 94 670 0.06 824 98 74 11/18/2013 1494 6.80 0,06 8 14 99.64 5/13/2014 14 94 6.39 0.06 855 99 05 11/14/2014 1494 721 0.06 7 73 98.23 5/21/2015 1494 6.92 0.06 802 9852 11/20/2015 14 94 6 14 0.06 8-80 9930 5/6/2016 14.94 620 0.06 8 74 99.24 12/12/2016 14 94 6.92 0.06 8.02 99-52 5/22/2017 14 94 6 83 0.06 8.11 98.61 11 /29/2017 14.94 754 0.06 740 97 90 5/29/2018 14.94 6 85 0.06 809 98 59 11/30/2018 14.94 5.79 0.06 9,15 9965 5/7/2019 14.94 6 14 0.06 8,80 99 30 11/5/2019 14 95 9,98 005 497 95 46 MW-5 5/24/2000 104 13 13 3-13 7/20/2000 NA 5 28 NA NA 98 85 10/11/2000 NA 4.84 NA NA 99,29 3/22/2001 NA 4,46 NA NA 9967 10/24/2001 NA 5.13 NA NA 9900 4/2/2002 NA 4,74 NA NA 9939 10/11/2002 NA 5.31 _ NA NA 98 82 1/10/2003 12.6 4.59 0.4 801 99 54 4/16/2003 12.85 4.30 0 15 8.55 99 83 7/2/2003 12.85 3.91 0 15 8.94 10022 4/13/2004 12.85 4.68 0.15 8.17 9945 5/31/2007 12,85 455 0.15 830 99,58 11/29/2007 12.85 6 23 0.15 6 62 97.90 5/19/2008 12 80 4 52 0 2 8 28 99,61 11/25/2008 12.86 4.93 0.14 793 99.20 6/4/2009 12 86 445 0 14 841 99.68 11/24/2009 NA 4.00 NA NA 100,13 3/4/2011 12 84 4.71 0,16 813 99,42 12/13/2011 12.84 4 72 0.16 8 12 99.41 5/25/2012 12.84 442 0 16 842 99.71 11/7/2012 13.90 5.14 0.90 8 76 98,99 5/22/2013 13.90 4.56 0.90 934 9957 H:PROJECTS0999119900470RMR 5-167-able 1 -Well Construction 8 Historical GW Elevation Page 2 rf6 Table I: Summary of Well Construction and Historical Groundwater Elevation Data Carolina Fast Mart N2 5104 Noth Highway 49, Concord, Cabarrus County, North Carolina NCDENR GWl #: 20117 Well ID Date Installed Top of Casing Elevation (Feet) As -built Depth (feet) Screened Interval (feet) Field Measurements Field Calculations Gauging Date Total Depth (feet) Depth to Static Water (feet) Diff. Between As -Built and Measured Total Depth (feet) Measured Water Column in Well (feet) Ground -water Elevation (feet) M W-5 CONT. 11/18/2013 13.90 4.65 090 9,25 9948 5/13/2014 1390 450 0,90 940 99 63 11/14/2014 13.90 5.51 0.90 839 98.62 5/21 /2015 13.90 4 70 0.90 920 9943 11/20/2015 13.90 4.45 0.90 9A5 99 68 5/6/2016 1390 4.76 090 9.14 99 37 12/12/2016 13.90 5.15 0.90 875 98 98 5/22/2017 1390 464 0,90 926 9949 11/29/2017 1390 4.95 0.90 8 95 99.18 5/29/2018 1390 468 090 922 9945 11 /30/2018 5/7/2019 11 /5/2019 13 90 4.67 090 923 99A6 13 90 4.74 090 9 16 99 39 13.90 6.45 0.90 745 9769 MW-6 5/24/2000 104 80 13 3-13 7/20/2000 NA 8.61 NA NA 96 19 10/11/2000 NA 8,32 NA NA 9648 3/22/2001 NA 6.19 NA NA 9861 10/24/2001 NA 8.55 NA NA 9625 4/2/2002 NA 7 16 NA NA 9764 ABANDONED MW-6A 9/10/2008 10501 13 3-13 11/25/2008 13.21 636 -0.21 6 85 UNK 6/4/2009 13 21 5.70 -0.21 7 51 UNK 11/24/2009 NA 5.32 NA NA 9969 3/4/2011 13 32 5.77 0.32 7.55 99 33 12/13/2011 13 32 5 81 0.32 7.51 99,20 5/25/2012 13 32 569 0.32 7.63 99.32 11/7/2012 13 23 6.84 0.23 6.39 98 17 5/22/2013 13 23 5 70 0.23 7.53 99.31 11/18/2013 13 23 600 0 23 723 9901 5/3/2014 13 23 5.40 0 23 7.83 99.61 11/14/2014 13.23 704 0.23 6.19 9797 5/21/2015 13 23 5 77 0.23 7.46 9924 l l/20/2015 NM - Not Required by NCDEQ MW-7 5/24/2000 105 39 13 3-13 7/20/2000 NA 6.86 NA NA 98 53 10/11/2000 NA 689 NA NA 98.50 3/22/2001 NA 476 NA _ NA 10063 10/24/2001 NA 690 _NA NA 98 49 4/2/2002 NA 5.44 NA _ NA 99 95 __j ABANDONED H:PROJECTS1199911990047WRMR 5-16Table 1 -Well Construction & Historical GWElevation Ng, 3 J6 Table I: Summary of Well Construction and Historical Groundwater Elevation Data Carolina Fast Mart #2 5104 Noth Highway 49, Concord, Cabarrus County, North Carolina NCDENR GWI #: 20117 Well ID Date Installed Top of Casing Elevation (feet) As -built Depth (feet) Screened Interval (feet) Field Measurements Field Calculations Gauging Date Total Depth (feet) Depth to Static Water (feet) Diff. Between As -Built and Measured Total Depth (feet) Measured Water Column in Well (feet) Ground -water Elevation (feet) MW-8 5/24/2000 104 79 13 3-13 7/20/2000 NA 1.96 NA NA 102.83 10/11/2000 NA 1.43 NA NA 103 36 3/22/2001 NA 0,45 NA NA 104,34 10/24/2001 NA 1,45 NA NA 103 34 4/2/2002 NA 1.08 NA NA 103.71 10/11/2002 NA 2,19 NA NA 10260 1/10/2003 12-61 1.33 0,39 11.28 10346 4/16/2003 12 87 0.71 0. 13 12.16 104.08 7/8/2003 12.87 090 0,13 11 97 103 89 4/13/2004 12.87 2.48 0.13 10,39 10231 6/4/2009 12.87 1_23 0.13 11.64 103 56 11/24/2009 NA 0.00 _ NA NA NM 3/4/2011 12.72 0.49 028 12,23 10430 12/13/2011 12.72 0.60 0.28 12.12 104 19 5/25/2012 12.72 0.84 U8 11.88 103 95 11 /7/2012 12 91 2.00 0.09 10.91 102 79 5/22/2013 12.91 0.50 0.09 12.41 10429 11/18/2013 12.91 0.83 0.09 12.08 103.96 5/13/2014 12.91 0.44 009 12.47 10435 11/14/2014 12.91 233 0,09 10.18 102.06 5/21 /2015 12.91 1.76 .0.09 11,15 103.03 11/20/2015 NM - Not Required b. NCDEQ MW-9 7/19/2000 103 34 14 5 4 5-14 5 7/20/2000 NA 6.01 NA NA 97.33 10/11/2000 NA 5.87 NA NA 97.47 3/22/2001 NA 5.03 NA NA 98.31 10/24/2001 NA 6,45 NA NA 96.89 4/2/2002 NA 5,50 NA NA 97.84 10/11/2002 NA 6.26 NA NA 97.08 1/10/2003 14 12 4 82 038 930 98.52 4/16/2003 14„21 4.56 029 965 98.78 7/2/2003 14.21 4.51 0,29 9,7 98 83 4/13/2004 14.21 5 03 0.29 9 18 9831 5/31/2007 1421 5.57 029 864 9777 11/29/2007 14.21 7 11 0.29 7 10 9623 5/19/2008 1436 4,79 0 14 9.57 98.55 11/25/2008 14.2 5 27 0.3 8,93 98.07 6/4/2009 14 2 4 81 0 3 939 9853 11/24/2009 14.2 4,63 03 9,57 98.71 3/4/2011 1U3 5 02 027 9,21 9832 12/13/2011 1423 5.28 0.27 8-95 98-06 5/25/2012 14 23 5,15 0.27 9,08 98.19 11/7/2012 14 25 5,76 0 25 8.49 97.58 5/22/2013 14 25 5.35 0 25 8,90 97.99 11/18/2013 14 25 5,32 0.25 8-93 98.02 5/13/2014 14 25 4.97 0.25 9.28 98,37 11/14/2014 14 25 5,70 0.25 8.55 9764 5/21/2015 14.25 5.03 425 9.22 9831 11/20/2015 1425 4.12 -U5 10.13 9922 5/6/2016 1425 4 51 -0.25 974 98 83 12/12/2016 14.25 546 -U5 8.79 97 88 5/22/2017 14.25 4,82 -0 25 9A3 98 52 11/29/2017 14.25 4.87 -0 25 9 38 9847 5/29/2018 14.25 480 -0.25 9 45 98 54 H PROJECT5119990990047WRMR 5-Wable 1 -Well Construction & Historical GW Elevation Ng' 4 rf6 Table I: Summary of Well Construction and Historical Groundwater Elevation Data Carolina Fast Mart #2 5104 Noth Highway 49, Concord, Cabarrus County, North Carolina NCDENR GWI #: 20117 Well ID Date Installed Top of Casing Elevation (feet) As -built Depth (feet) Screened Interval (feet) Field Measurements Field Calculations Gauging Date Total Depth (feet) Depth to Static Water (feet) Diff. Between As -Built and Measured Total Depth (feet) Measured Water Column in Well (feet) Ground -water Elevation (feet) MW-10 7/19/2000 10547 6 3-6 7/20/2000 NA 3.75 NA NA 101.72 10/11/2000 NA 3.10 NA NA 102.37 3/22/2001 NA 1.62 NA NA 103.85 10124/2001 NA 5.36 NA NA 100,11 4/2/2002 NA 5 41 NA NA 10006 ABANDONED MW-IOA 1 1 /30/2009 10648 10 2-10 12/10/2009 9.91 4.32 -3 91 5,59 101 15 3/4/2011 9.85 5.75 0.15 4.10 10073 12/13/811 9.85 6.18 0.15 3.67 100.30 5/25/2012 985 6.33 0.15 3.52 100 15 11/7/2012 9.88 7.94 0.12 1.94 97.53 5/22/2013 9-88 6.10 0.12 378 100.38 11/18/2013 9.88 TOO 0.12 2.88 99.48 5/13/2014 9.88 523 0.12 4.65 101.25 11/14/2014 9,88 8.01 0J2 1.87 98.47 5/21/2015 9.88 6.1 1 -0.12 3.77 10037 11/20/2015 NM - Not Required b NCDEQ MW-11 7/19/2000 9877 10 2-10 7/20/2000 NA 4.50 NA NA 94.27 10/11/2000 NA 3.90 NA NA 94.87 3/22/2001 NA 0.55 NA NA 9822 10/24/2001 NA 4.13 NA NA 94-64 4/2/2002 NA 2.55 NA NA 96.22 ABANDONED MW-IIA 111/302009 10294 10 2-10 12/10/2009 869 5.38 1.31 331 9756 3/4/2011 918 7.16 0.82 836 95.78 12/13/2011 9 18 6.71 0.82 2.47 9623 5/25/2012 9.18 723 0.82 1.95 95.71 11/7/2012 920 7 80 0.80 1-40 95.14 5/22/2013 926 7 59 0.74 1.67 95.35 11/18/2013 926 7.85 0.74 1.41 9509 5.23/14 926 760 0.74 1.66 95.34 11/14/2014 9 26 7.95 0.74 1.31 9499 5/21/2015 9 26 778 -0.74 1.48 95.16 11/20/2015 NM -Not Re uired b NCDEQ H PROJECTSil999119900471l4RMR 5-16Tabte 1 - Welt Construction & Historical GW Elevation Nge S of 6 "fable 1: Summary of Well Construction and Historical Groundwater Elevation Data Carolina Fast Mart #2 5104 Noth Highway 49, Concord, Cabarrus County, North Carolina NCDENR GWf #: 20117 Well ID L_ Date Installed Top of Casing Elevation (feet) As -built Depth (feet) Screened Interval (feet) Field Measurements Field Calculations Gauging Date Total Depth (feet) Depth to Static Water (feet) Diff. Between As -Built and Measured Total Depth (feet) Measured Water Column in Well (feet) Ground -water Elevation (feet) f-1 2/24/2000 105 42 30 25-30 7/20/2000 NA 1677 NA NA 8865 10/11/2000 NA 13.22 NA NA 92 20 3/22/2001 NA 1965 NA NA 85 77 10/24/2001 NA 18.31 NA NA 8711 4/2/2002 NA 19 89 NA NA 85 53 10/11/2002 NA 25.38 NA NA 8004 1/10/2003 29.76 23 82 0.24 5.94 81 60 4/16/2003 29.85 22.21 0.15 7.64 83 21 7/2/2003 29 85 24.60 0.15 5.25 80 82 4/13/2004 29 85 11.60 0.15 1825 93 82 11/24/2009 NA 16.14 NA NA 89.28 3/4/2011 NA NA NA NA NA 12/13/2011 NA NA NA NA NA 5/25/2012 29 84 0.05 0.16 29.79 105.37 11/7/2012 28.90 0.25 1.1 28.65 105.17 5/22/2013 2890 2.94 1 1 25.96 102.48 11/18/2013 2890 008 1 1 28 82 105.34 5/13/2014 2990 20.01 1 1 8.89 85 41 11/14/2014 2890 2093 1.1 7.97 9449 5/21/2015 28 90 2090 -1.1 8.00 84 52 11/20/2015 28 90 21 26 -l.l 7.64 84 16 5/6/2016 28 90 16 78 -1 1 12.12 88.64 12/12/2016 28 90 17.58 -1.1 11.32 87.84 5/22/2017 28 90 21 28 -1 1 762 84.14 11 /29/2017 2890 18.48 •1.1 1042 8694 5/29/2018 28 90 20.66 -1.1 824 8476 MW-12 4/29/2011 NA 10 2-10 12/13/2011 9.3 T38 07 192 NM 5/25/2012 9.3 7.02 -9 3 2 28 NM 11/7/2012 9.43 8.09 0.57 1.34 NM 5/22/2013 9.43 6.77 0.57 2 66 NM 11/18/2013 9.43 7.84 0.57 159 NM 5/13/2014 9.43 6.76 0.57 2 67 NM 11/14/2014 9.43 7.67 0.57 176 NM 5/21/2015 9.43 7.13 -0.57 230 NM 11/20/2015 9.43 6.23 -0.57 320 NM 5/6/2016 9.43 7.05 -0.57 239 NM 12/12/2016 9.43 7.50 -0.57 193 NM 5/22/2017 9-43 7.01 -0.57 2.42 NM 11/29/2017 943 7.43 -0.57 200 NM 5/29/2018 943 6.96 -0.57 2.47 NM 1. NA Not Appllcuhle 2, DIlY lnsu/Jicenl Water to Well In Al1nw,/or Mecr.+uremen! 3 NM -Not Measured 4. NCDEQ = North Carolina Department of Environmental Quality H PROJECTSI7999119900470RMR 5-16Table 1 -Well Construction & Hisloncal GW Elevation Mg, f6 Table 2: Summary of Analytical Results - Groundwater Samples Carolina Fast Mart #2 5104 North Highway 49, Concord, Cabarrus County, North Carolina NCDENR GWI #: 20117 Analytical Method—> EPA 62006 EPA 504.1 EPA 200.7 I a, o u a a a E s a, s i fi O O6 V J D6 t j, o G O U Z C f � 15A NCAC 2L.0202 Standard—> 6000 1 70 600 600 70 100 70 70 70 500 20 70 6 70 0.0004 15 15A NCAC 2LA715 Gross Contamination level Co 6,000,000 5,000 8,500 260,000 84,500 250,000 10000 ,0 6,900 300,000 15,000 85,500 200,000 70,000 6,000 70,000 0.0004 15,000 Location Date u¢/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/l MW-4 11/05/19 6 1 J ND ND ND 0.47 J ND ND ND 0 3 J ND ND 13 067 041 J ND ND 0.00057 J MW-5 11/05/19 21 ND 068 ND 0.99 6 ND 0.28 J 10 ND 0,73 J 13 037 J 7.2 ND ND ND WSW -IA 11/05/19 2.0 J ND ND ND ND ND ND ND ND ND ND ND ND ND 0.34 J ND 0.000621 Trip Blank - 1.8 J ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND NA Notes ug/l = Units in micrograms per liter ND = Not detected at or above the method detection limit specified in the laboratory report NA = Not analyzed per NCDEQ Request J = Detected but below the Reporting Limit, therefore, the result is an estimated concentration 15A. NCAC 2L.0202 = North Carolina Administrative Code 2L Groundwater Standards Gross Contamination Levels = NCDEQ Standard Statute for risked based maximum gross contamination levels for groundwater as presented in the NCDEQ "Guidelines for Assessment and Corrective Action," dated April 2001, effective July 1, 2001 BOLD = Above 2L Standards All other data can be seen in the attached laboratory report H:\Projects\l999\1990047 CFM#2\Reports\2019-11 LTR Report\Table 2 - Groundwater Analytical Results Page 1 'PENDIX A PRISM AaU WORIFFS INC Shield Engineering, Inc. Kevin Stachura 4301 Taggart Creek Rd. Charlotte, NC 28208 NC Certification No. 402 Full -Service Analytical & NC Drinking Water Cert No. 37735 Environmental Solutions 5C Certification No. 99012 Project: Carolina Fast Mart #2 Lab Submittal Date: 11/06/2019 Prism Work Order: 9110119 Case Narrative 11/15/19 10:11 This data package contains the analytical results for the project identified above and includes a Case Narrative, Sample Results and Chain of Custody. Unless otherwise noted, all samples were received in acceptable condition and processed according to the referenced methods. Data qualifiers are flagged individually on each sample. A key reference for the data qualifiers appears at the end of this case narrative. Please call if you have any questions relating to this analytical report. Respectfully, PRISM LABORATORIES, INC. Robbi A. Jones President/Project Manager Data Qualifiers Key Reference: Reviewed By Robbi A. Jones President/Project Manager CCV CCV result is above the control limits. Analyte not detected in the sample. No further action taken. D RPD value outside of the control limits. J Detected but below the Reporting Limit; therefore, result is an estimated concentration (CLP J-Flag). U Not Detected at the MDL MDL Method Detection Limit RPD Relative Percent Difference * Results reported to the reporting limit. All other results are reported to the MDL with values between MDL and reporting limit indicated with a J. This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224.0543 Phone: 704/529-6364 - Toll Free Number: 1.800/529-6364 - Fax: 704/525-0409 Page 1 of 19 PRISM I Environmental Analytical 8 Environrnontal Solutions Sample Receipt Summary 11 /15/2019 Prism Work Order: 9110119 Client Sample ID Lab Sample ID Matrix Date/Time Sampled Date/Time Received MW-4 9110119-01 Water 11/05/19 12:00 11/06/19 15:30 MW-5 9110119-02 Water 11/05/19 11:45 11/06/19 15:30 WSW-1A 9110119-03 Water 11/05/19 11:25 11/06/19 15:30 Trip Blank 9110119-04 Water 11/05/19 0:00 11/06/19 15:30 Samples were received in good condition at 3.2 degrees C unless otherwise noted. This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529.6364 - Toll Free Number: 1-8001629-6364 - Fax: 704/525-0409 Page 2 of 19 GeneralMethod PRISMFu l l(annlcu Analytical s EIIVifOnf110n1al Solutions Summary of Detections 11/15/2019 Prism Work Order: 9110119 Prism ID Client ID Parameter General Method Method Result Units 9110119-01 MW-4 Lead Total Metals 6020E 0.00053 mg/L 9110119-01 MW-4 Acetone Volatile Organic Compounds by GC/MS SM6200 B 6.1 J ug/L 9110119-01 MW-4 Ethylbenzene Volatile Organic Compounds by GC/MS SM6200 B 0.47 J ug/L 9110119-01 MW-4 Isopropyl Ether Volatile Organic Compounds by GC/MS SM6200 B 0.67 ug/L 9110119-01 MW-4 Methyl-tert-Butyl Ether Volatile Organic Compounds by GC/MS SM6200 B 1.3 ug/L 9110119-01 MW-4 Naphthalene Volatile Organic Compounds by GC/MS SM6200 B 0.41 J ug/L 9110119-01 MW-4 n-Propylbenzene Volatile Organic Compounds by GC/MS SM6200 B 0.30 J ug/L 911 Q119-02 MW-5 Acetone Volatile Organic Compounds by GC/MS SM6200 B 21 ug/L 9110119-02 MW-5 Ethylbenzene Volatile Organic Compounds by GC/MS SM6200 B 0.99 ug/L 9110119-02 MW-5 Isopropyl Ether Volatile Organic Compounds by GC/MS SM6200 B 0.37 J ug/L 9110119-02 MW-5 Isopropylbenzene (Cumene) Volatile Organic Compounds by GC/MS SM6200 B 6.0 ug/L 9110119-02 MW-5 m,p-Xylenes Volatile Organic Compounds by GC/MS SM6200 B 0.73 J ug/L 9110119-02 MW-5 Methyl Ethyl Ketone (2-ButancVolatile Organic Compounds by GC/MS SM6200 B 2.6 J ug/L 9110119-02 MW-5 Methyl-tert-Butyl Ether Volatile Organic Compounds by GC/MS SM6200 B 13 ug/L 9110119-02 MW-5 Naphthalene Volatile Organic Compounds by GC/MS SM6200 B 7.2 ug/L 9110119-02 MW-5 n-Butylbenzene Volatile Organic Compounds by GC/MS SM6200 B 0.28 J ug/L 9110119-02 MW-5 n-Propylbenzene Volatile Organic Compounds by GC/MS SM6200 B 10 ug/L 9110119-02 MW-5 sec-Butylbenzene Volatile Organic Compounds by GC/MS SM6200 B 068 ug/L 9110119-02 MW-5 Xylenes, total Volatile Organic Compounds by GC/MS SM6200 B 0.73 J ug/L 9110119-03 WSW-1A Lead Total Metals 6020E 0.00062 mg/L 9110119-03 WSW-lA Acetone Volatile Organic Compounds by GC/MS SM6200 B 2.0 J ug/L 9110119-03 WSW-1A Chloroform Volatile Organic Compounds by GC/MS SM6200 B 0.34 J ug/L 9110119-04 Trip Blank Acetone Volatile Organic Compounds by GC/MS SM6200 B 1.8 J ug/L This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc, 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 7041525.0409 Page 3 of 19 PRISM I Envifa rviAnalytical Environmananlal Solutions 11-11+Cne4t S - Shield Engineering, Inc. Attn: Kevin Stachura 4301 Taggart Creek Rd. Charlotte. NC 28208 Project: Carolina Fast Mart #2 Sample Matrix: Water Laboratory Report 11 / 15/2019 Client Sample ID: MW-4 Prism Sample ID: 9110119-01 Prism Work Order: 9110119 Time Collected: 11/05/19 12:00 Time Submitted: 11/06/19 15:30 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor Date/Time ID Total Metals Lead 0.00057 J mg/L 0.0010 0.00044 1 6020B 1118/19 18:18 MMR P911(0164 Volatile Organic Compounds by GC/ECD 1,2-Dibromoethane (EDB) 0.0025 U ug/L 0.021 0.0025 1 504.1 11/11/19 12:25 NMB P91<0194 Volatile Organic Compounds by GC/MS 1,1,1,2-Tetrachloroethane 0.11 U ug/L 0.50 0.11 1 SM6200 B 11/11/19 15:42 KDM P91<0225 1,1,1-Trichloroethane 0.061 U ug/L 0.50 0.061 1 SM6200 B 11/11/19 15:42 KDM P91<0225 1,1.2,2-Tetrachloroethane 0.036 U ug/L 0.50 0.036 1 SM6200 B 11/11/19 15:42 KDM P91<0225 1,1,2-Trichloroethane 0.066 U ug/L 0.50 0.066 1 SM6200 B 11/11/19 15:42 KDM P91<0225 1.1-Dichloroethane 0.083 U ug/L 0.50 0.083 1 SM6200 B 11/11/19 15:42 KDM P91<0225 1,1-Dichloroethylene 0.083 U ug/L 0.50 0.083 1 SM6200 B 11/11/19 15.42 KDM P91<0225 1 1-Dichloropropylene 0.051 U ug/L 0.50 0,051 1 SM6200 8 11/11/19 15:42 KDM P91<0225 1,2,3-Tiichlorobenzene 0.40 U ug/L 0,50 0.40 1 SM6200 8 11/11/19 15:42 KDM P91<0225 1,2.3-Trichloropropane 0.14 U ug/L 0-50 0.14 1 SM6200 B 11/11/19 15:42 KDM P91<0225 1,2,4-Trichlorobenzene 0,13 U ug/L 0,50 0.13 1 SM6200 B 11/11/19 15:42 KDM P91<0225 1,2,4-Trimethylbenzene 0,054 U ug/L 0.50 0.054 1 SM6200 B 11/11/19 15:42 KDM P91<0225 1,2-Dibromo-3-chloropropane 0.17 U ug/L 2.0 0.17 1 SM6200 B 11/11/19 15:42 KDM P91<0225 1,2-Dibromoethane 0,051 U ug/L 0.50 0.051 1 SM6200 B 11/11/19 15:42 KDM P91<0225 1,2-Dichlorobenzene 0.076 U ug/L 0.50 0.076 1 SM6200 B 11111/19 15:42 KDM P91<0225 1.2-Dichloroethane 0,066 U ug/L 0,50 0.066 1 SM6200 B 11111/19 15:42 KDM P9K0225 1.2-Dichloropropane 0.11 U ug/L 0.50 0.11 1 SM6200 B 11/11/19 15:42 KDM P91<0225 1,3,5-Trimethylbenzene 0.076 U ug/L 0,50 0.076 1 SM6200 B 11/11/19 15:42 KDM P91<0225 1,3-Dichlorobenzene 0,054 U ug/L 0.50 0.054 1 SM6200 B 11/11/19 15:42 KDM P91<0225 1,3-Dichloropropane 0.043 U ug/L 050 0.043 1 SM6200 B 11/11/19 15:42 KDM P91<0225 1,4-Dichlorobenzene 0.050 U ug/L 0.50 0.050 1 SM6200 B 11/11/19 15:42 KDM P91<0225 2 2-Dichloropropane 0,11 U ug/L 2.0 0.11 1 SM6200 B 11/11/19 15:42 KDM P91<0225 2-Chlorotoluene 0.066 U ug/L 050 0.066 1 SM6200 B 11/11/19 15:42 KDM P91<0225 4-Chlorotoluene 0,050 U ug/L 0-50 0.050 1 SM6200 B 11/11/19 15:42 KDM P91<0225 4-Isopropyltoluene 0 089 U ug/L 0.50 0.089 1 SM6200 B 11/11/19 15:42 KDM P91<0225 Acetone 6.1 1 ug/L 10 0.31 1 SM6200 B 11/11/19 15:42 KDM P9K0225 Benzene 0.048 U ug/L 0.50 0.048 1 SM6200 B 11/11/19 15:42 KDM P91<0225 Bromobenzene 0.057 U ug/L 0.50 0.057 1 SM6200 B 11/11/19 15:42 KDM P91<0225 Bromochloromethane 0.14 U ug/L 0.50 0.14 1 SM6200 B 11/11/19 15:42 KDM P91<0225 Bromodichloromethane 0.062 U ug/L 0.50 0.062 1 SM6200 B 11/11/19 15:42 KDM P91<0225 Bromoform 0.040 U ug/L 0.50 0.040 1 SM6200 B 11/11/19 15:42 KDM 1391<0225 Bromomethane 0.18 U ug/L 1.0 0.18 1 SM6200 B 11/11/19 15:42 KDM 1391<0225 Carbon Tetrachloride 0.11 U ug/L 0.50 0,11 1 SM6200 B 11/11/19 15:42 KDM P91<0225 Chlorobenzene 0.062 U ug/L 0.50 0.062 1 SM6200 B 11/11/19 15:42 KDM P91<0225 Chloroethane 0.22 U ug/L 0.50 0,22 1 SM6200 B 11/11/19 15:42 KDM P91<0225 Chloroform 0.076 U ug/L 0.50 0.076 1 SM6200 B 11/11/19 15:42 KDM P91<0225 Chloromethane 0.079 U ug/L 0.50 0,079 1 SM6200 B 11/11/19 15:42 KDM P91<0225 cis- 1,2-Dichloroethylene 0,056 U ug/L 0.50 0.056 1 SM6200 B 11/11/19 15:42 KDM P91<0225 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/629-6364 - Toll Free Number: 1-8001529-6364 - Fax: 704/525-0409 Page 4 of 19 Laboratory Report 11/15/2019 PRISM FIflI-':TMlrukce Analy Yi ral A Fnvll'tl�irrie nl al Sr>lutio ns Shield Engineering, Inc. Attn: Kevin Stachura 4301 Taggart Creek Rd. Charlotte, NC 28208 Project: Carolina Fast Mart #2 Sample Matrix: Water Parameter Result Units cis- 1,3-Dichloropropylene 0.079 U ug/L Dibromochloromethane 0.081 U ug/L Dibromomethane 0.065 U ug/L Dichlorodifluoromethane 0.11 UCCV ug/L Ethanol 27 U ug/L Ethylbenzene 0.47 J ug/L Hexachlorobutadiene 0,16 U ug/L Isopropyl Ether 0.67 ug/L Isopropylbenzene (Cumene) 0.054 U ug/L m,p-Xylenes 0.12 U ug/L Methyl Butyl Ketone (2-Hexanone) 0.065 U ug/L Methyl Ethyl Ketone (2-Butanone) 0.24 U ug/L Methyl Isobutyl Ketone 0.078 U ug/L Methylene Chloride 0.083 U ug/L Methyl-tert-Butyl Ether 1.3 ug/L Naphthalene 0.41 J ug/L n-Butylbenzene 0.076 U ug/L n-Propylbenzene 0.30 J ug/L o-Xylene 0,044 U ug/L sec-Butylbenzene 0.076 U ug/L Styrene 0.047 U ug/L tert-Butylbenzene 0,088 U ug/L Tetrachloroethylene 0,098 U ug/L Toluene 0,044 U ug/L trans-1,2-Dichloroethylene 0.070 U ug/L trans-1,3-Dichloropropylene 0,12 U ug/L Trichloroethylene 0,078 U ug/L Trichlorofluoromethane 0.062 U ug/L Vinyl acetate 0,060 U ug/L Vinyl chloride 0.097 U ug/L Xylenes, total 0,15 U ug/L Report Limit 0.50 0,50 0 50 1.0 200 0.50 20 0.50 0.50 1.0 1.0 5.0 1.0 2.0 1.0 1.0 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 5.0 0.50 1.5 Surrogate Client Sample ID: MW-4 Prism Sample ID: 9110119-01 Prism Work Order: 9110119 Time Collected: 11/05/19 12:00 Time Submitted: 11/06/19 15:30 MDL Dilution Factor Method Analysis Analyst Date/Time Batch ID 0.079 1 SM6200 B 11/11/19 15:42 KDM P91<0225 0.081 t SM6200 B 11/11/19 15:42 KDM P9K0225 0.065 t SM5200 B 11/11/19 15:42 KDM P91<0225 0.11 1 SM6200 B 11/11/19 15:42 KDM P91<0225 27 1 SM6200 B 11/11/19 15:42 KDM P91<0225 0.061 1 SM6200 B 11111/19 15:42 KDM P91K0225 0.16 1 SM6200 B 11/11/19 15:42 KDM P91<0225 0.050 1 SM6200 B 11111/19 15:42 KDM P9K0226 0.054 1 SM6200 B 11/11/19 15:42 KDM P91<0225 0,12 1 SM6200 B 11/11/19 15:42 KDM P91<0225 0,065 1 SM6200 B 11/11/19 15:42 KDM P91<0225 0.24 1 SM6200 B 11/11/19 15:42 KDM P91<0225 0 078 1 SM6200 B 11/11/19 15:42 KDM P91<0225 0.083 1 SM6200 B 11/11/19 15:42 KDM P91<0225 0.042 1 SM6200 B 11/11119 15:42 KDM P91<0225 0.19 1 SM6200 B 11/11119 15:42 KDM P9K0225 0,076 1 SM6200 B 11/11/19 15:42 KDM P91<0225 0.087 1 SM6200 B 11/11/19 15;42 KDM 1391<0225 0.044 1 SM6200 B 11/11/19 15:42 KDM P91<0225 0.076 1 SM6200 B 11/11/19 15:42 KDM P91<0225 0 047 1 SM6200 B 11/11/19 15:42 KDM P91<0225 0.088 1 SM6200 B 11/11/19 15:42 KDM P91<0225 0.098 1 SM6200 B 11/11/19 15:42 KDM P91<0225 0.044 1 SM6200 B 11/11/19 15:42 KDM P91<0225 0.070 1 SM6200 B 11/11/19 15:42 KDM P91<0225 0.12 1 SM6200 B 11/11/19 15:42 KDM P91<0225 0.078 1 SM6200 B 11/11/19 15:42 KDM P91<0225 0.062 1 SM6200 B 11/11/19 15:42 KDM P9K0225 0.060 1 SM6200 B 11/11/19 15:42 KDM P9K0225 0,097 1 SM6200 B 11/11/19 15:42 KDM P9K0225 0.15 1 SM6200 B 11/11/19 15:42 KDM P9K0225 Recovery Control Limits 4-Bromofluorobenzene 99 % 70-130 Dibromofluoromethane 100 % 70-130 Toluene-d8 96 % 70-130 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224.0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529.6364 - Fax: 704/525.0409 Page 5 of 19 SM I F..n r r ll�i-SAIfVtCH Analyticei it Laboratory Report ,y virejnmental Solutions 11 /15/2019 Shield Engineering, Inc. Project: Carolina Fast Mart #2 Client Sample ID: MW-5 Attn: Kevin Stachura Prism Sample ID: 9110119-02 4301 Taggart Creek Rd. Prism Work Order: 9110119 Charlotte, NC 28208 Sample Matrix: Water Time Collected: 11/05/19 11:45 Time Submitted: 11 /06/19 15:30 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor Date/Time ID Total Metals Lead 0.00044 U mg/L 0.0010 0.00044 1 6020B 11/8/19 18:37 MMR P91<0164 Volatile Organic Compounds by GC/ECD 1,2-Dibromoethane (EDB) 00025 U ug/L 0.020 0.0025 1 504.1 11/11/19 12:56 NMB 139K0194 Volatile Organic Compounds by GC/MS 1.1,1,2-Tetrachloroethane 0.11 U ug/L 0.50 0.11 1 SM6200 B 11/11/19 16:09 KDM P9K0225 1,1,1-Trichloroethane 0 061 U ug/L 0.50 0.061 1 SM6200 B 11/11/19 16:09 KDM P9K0225 1,1,2,2-Tetrachloroethane 0.036 U ug/L 0.50 0.036 1 SM6200 B 11/11/19 16:09 KDM P9K0225 1,1,2-Trichloroethane 0.066 U ug/L 0.50 0.066 1 SM6200 B 11/11/19 16:09 KDM P9K0225 1,1-Dichloroethane 0.083 U ug/L 0.50 0.083 1 SM6200 B 11/11/19 16:09 KDM P9K0225 1,1-Dichloroethylene 0,083 U ug/L 0.50 0.083 1 SM6200 B 11/11/19 16:09 KDM P9K0225' 1,1-Dichloropropylene 0,051 U ug/L 0.50 0.051 1 SM6200 B 11/11/19 16:09 KDM P9K0225 1,2,3-Trichlorobenzene 0.40 U ug/L 0,50 0.40 1 SM6200 B 11/11/19 16:09 KDM P9K0225 1,2,3-Trichloropropane 0.14 U ug/L 0.50 0.14 1 SM6200 B 11/11/19 16:09 KDM P9K0225 1,2,4-Trichlorobenzene 0.13 U ug/L 0.50 0.13 1 SM6200 B 11/11/19 16:09 KDM P91<0225 1,2,4-Trimethylbenzene 0.054 U ug/L 0.50 0.054 1 SM6200 B 11/11/19 16:09 KDM P91<0225 1,2-Dibromo-3-chloropropane 0.17 U ug/L 2.0 0.17 1 SM6200 B 11/11/19 16:09 KDM P91<0225 1,2-Dibromoethane 0.051 U ug/L 0.50 0.051 1 SM6200 B 11/11/19 16,09 KDM P91<0225 1,2-Dichlorobenzene 0.076 U ug/L 0.50 0.076 1 SM6200 B 11/11/19 16:09 KDM P91<0225 1.2-Dichloroethane 0.066 U ug/L 0.50 0.066 1 SM6200 B 11/11/19 16:09 KDM P91<0225 1,2-Dichloropropane 0,11 U ug/L 0.50 0,11 1 SM6200 B 11/11/19 16:09 KDM P91<0225 1,3,5-Trimethylbenzene 0-076 U ug/L 0.50 0.076 1 SM6200 B 11/11/19 16:09 KDM P91<0225 1,3-Dichlorobenzene 0.054 U ug/L 0,50 0.054 1 SM6200 B 11/11/19 16:09 KDM P91<0225 1,3-Dichloropropane 0,043 U ug/L 050 0.043 1 SM6200 B 11/11/19 16:09 KDM P91<0225 1.4-Dichlorobenzene 0.050 U ug/L 0,50 0.050 1 SM6200 B 11/11/19 16:09 KDM P91<0225 2,2-Dichloropropane 0.11 U ug/L 2.0 0.11 1 SM6200 B 11/11/19 16:09 KDM P91<0225 2-Chlorotoluene 0.066 U ug/L 0,50 0.066 1 SM6200 B 11/11/19 16:09 KDM P91<0225 4-Chlorotoluene 0.050 U ug/L 0.50 0.050 1 SM6200 B 11/11/19 16:09 KDM P91<0225 4-Isopropyltoluene 0 089 U ug/L 0.50 0.089 1 SM6200 B 11/11/19 16:09 KDM P91<0225 Acetone 21 ug1L 10 0.31 1 SM6200 B 11/11/19 16:09 KDM P9K0225 Benzene 0.048 U ug/L 0.50 0.048 1 SM6200 B 11/11/19 16:09 KDM P91<0225 Bromobenzene 0.057 U ug/L 0.50 0.057 1 SM6200 B 11/11/19 16:09 KDM P91<0225 Bromochloromethane 0.14 U ug/L 0.50 0.14 1 SM6200 B 11/11/19 16:09 KDM P91<0225 Bromodichloromethane 0,062 U ug/L 0.50 0.062 1 SM6200 B 11/11/19 16:09 KDM P9K0225 Bromoform 0.040 U ug/L 0.50 0,040 1 SM6200 B 11/11/19 16:09 KDM P9K0225 Bromomethane 0.18 U ug/L 1.0 D.18 1 SM6200 B 11/11/19 16:09 KDM P9K0225 Carbon Tetrachloride 0.11 U ug/L 0.50 0.11 1 SM6200 B 11/11/19 16:09 KDM P9K0225 Chlorobenzene 0,062 U ug/L 0,50 0,062 1 SM6200 B 11/11/19 16:09 KDM P91<0225 Chloroethane 0.22 U ug/L 0.50 0.22 1 SM6200 B 11/11/19 16:09 KDM P90225 Chloroform 0.076 U ug/L 0.50 0.076 1 SM6200 B 11/11/19 16:09 KDM P9K0225 Chloromethane 0,079 U ug/L 0.50 0.079 1 SM6200 B 11/11/19 16:09 KDM P9K0225 cis-1,2-Dichloroethylene 0.056 U ug/L 0.50 0.056 1 SM6200 B 11/11/19 16:09 KDM P91<0225 cis-1,3-Dichloropropylene 0,079 U ug/L 0.50 0.079 1 SM6200 B 11/11/19 16:09 KDM P91<0225 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc 449 Springbrook Road - P.O. Box 240643 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 7041625.0409 Page 6 of 19 I EAnalyticals Laboratory Report PRISM.Fnviroinenlal Olutions 11/15/2019 Shield Engineering, Inc. Project: Carolina Fast Mart #2 Client Sample ID: MW-5 Attn: Kevin Stachura Prism Sample ID: 9110119-02 4301 Taggart Creek Rd. Prism Work Order: 9110119 Charlotte, NC 28208 Sample Matrix: Water Time Collected: 11/05/19 11:45 Time Submitted: 11/06/19 15:30 Parameter Result Units Report Limit MOIL Dilution Factor Method Analysis Analyst Date/Time Batch ID Dibromochloromethane 0.081 U ug/L 0.50 0,081 1 SM6200 B 11/11/19 16:09 KDM P91<0225 Dibromomethane 0 065 U ug/L 0.50 0.065 1 SM6200 B 11/11/19 16:09 KDM 1391<0225 Dichlorodifluoromethane 0.11 UCCV ug/L 1.0 0.11 1 SM6200 B 11/11/19 16:09 KDM P91<0225 Ethanol 27 U ug/L 200 27 1 SM6200 B 11/11/19 16:09 KDM P9K0225 Ethylbenzene 0.99 ug/L 0.50 0.061 1 SM6200 B 11/11119 16:09 KDM P91K0225 Hexachlorobutadiene 0.16 U ug/L 2.0 0.16 1 SM6200 B 11/11/19 16:09 KDM P9K0225 Isopropyl Ether 0.37 J ug/L 0.50 0.050 1 SM6200 B 11111119 16:09 KDM P91K0225 Isopropylbenzene (Cumene) 6.0 ug/L 0.50 0.054 1 SM6200 B 11111119 16:09 KDM P91<0225 m,p-Xylenes 0.73 J ug/L 1.0 0.12 1 SM6200 B 11111119 16:09 KDM P91K0225 Methyl Butyl Ketone (2-Hexanone) 0,065 U ug/L 1.0 0.065 1 SM6200 B 11/11/19 16:09 KDM P91<0225 Methyl Ethyl Ketone (2-Butanone) 2.6 J ug/L 5.0 0.24 1 SM6200 B 11111119 16:09 KDM P91<0225 Methyl Isobutyl Ketone 0.078 U ug/L 1.0 0.078 1 SM6200 B 11/11/19 16:09 KDM P91<0225 Methylene Chloride 0.083 U ug/L 2.0 0.083 1 SM6200 B 11/11/19 16:09 KDM P9K0225 Methyl-tert-Butyl Ether 13 ug/L 1.0 0.042 1 SM6200 B 11111/19 16:09 KDM P91K0225 Naphthalene 7.2 ug/L 1.0 0.19 1 SM6200 B 11111119 16:09 KDM P9K0225 n-Butylbenzene 0.28 J ug/L 0.50 0.076 1 SM6200 B 11111/19 16:09 KDM P91K0225 n-Propylbenzene 10 ug/L 0.50 0.087 1 SM6200 B 11111/19 16:09 KDM P9K0225 o-Xylene 0 044 U ug/L 0.50 0 044 1, SM6200 B 11/11/19 16:09 KDM P91<0225 sec-Butylbenzene 0,68 ug/L 0.50 0.076 1 SM6200 B 11/11/19 16:09 KDM P91K0225 Styrene 0 047 U ug/L 0.50 0,047 1 SM6200 B 11/11/19 16:09 KDM P91<0225 tert-Butylbenzene 0.088 U ug/L 0.50 0.088 1 SM6200 B 11/11/19 16:09 KDM P9K0225 Tetrachloroethylene 0.098 U ug/L 0.50 0.098 1 SM6200 B 11/11/19 16:09 KDM P9K0225 Toluene 0.044 U ug/L 0,50 0,044 1 SM6200 B 11/11/19 16:09 KDM P9K0225 trans-1,2-Dichloroethylene 0.070 U ug/L 0.50 0.070 1 SM6200 B 11/11/19 16:09 KDM P9K0225 trans-1,3-Dichloropropylene 0.12 U ug/L 0.50 0.12 1 SM6200 B 11/11/19 16:09 KDM P91<0225 Trichloroethylene 0,078 U ug/L 0.50 0.078 1 SM6200 B 11/11/19 16:09 KDM P91<0225 Trichlorofluoromethane 0.062 U ug/L 0,50 0.062 1 SM6200 B 11/11/19 16:09 KDM P91<0225 Vinyl acetate 0.060 U ug/L 5 0 0.060 1 SM6200 B 11/11/19 16:09 KDM P91<0225 Vinyl chloride 0.097 U ug/L 0.50 0.097 t SM6200 B 11/11/19 16:09 KDM P91<0225 Xylenes, total 0.73 J uglL 1.5 0.16 1 SM6200 B 11111119 16:09 KDM P91K0225 Surrogate Recovery Control Limits 4-Bromofluorobe nzene 97 % 70-130 Dibromofluoromethane 99 % 70-130 Toluene-d8 95 % 70-130 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-8001529-6364 - Fax: 704/525-0409 Page 7 of 19 Analytical8 Laboratory Report �'PRISMI Enviroilmanl91 olulioos 11/15/2019 ' ...a. . ,AF[IFAttIRIFS ING Shield Engineering, Inc. Project: Carolina Fast Mart #2 Client Sample ID: WSW-1A Attn: Kevin Stachura Prism Sample ID: 9110119-03 4301 Taggart Creek Rd. Prism Work Order: 9110119 Charlotte, NC 28208 Sample Matrix: Water Time Collected: 11/05/19 11:25 Time Submitted: 11/06/19 15:30 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor Date/Time ID Total Metals Lead 0.00062 J mg/L 0.0010 0.00044 1 6020B 1118/19 18:44 MMR P9K0164 Volatile Organic Compounds by GC/ECD 1,2-Dibromoethane (EDB) 0,0024 U ug/L 0.020 0.0024 1 504A 11/11/19 13:26 NMB P91<0194 Volatile Organic Compounds by GCIMS 1,1,1,2-Tetrachloroethane 0,11 U ug/L 0.50 0.11 1 SM6200 B 11/11/19 16:35 KDM P91<0225 1.1,1-Trichloroethane 0.061 U ug/L 0.50 0.061 1 SM6200 B 11/11/19 16:35 KDM P91<0225 1,1,2,2-Tetrachloroethane 0.036 U ug/L 0.50 0.036 1 SM6200 B 11/11/19 16:35 KDM P91<0225 1.1,2-Trichloroethane 0.066 U ug/L 0.50 0.066 1 SM6200 B 11/11/19 16:35 KDM P91<0225 1,1-Dichloroethane 0.083 U ug/L 0.50 0.083 1 SM6200 B 11/11/19 16:35 KDM P91<0225 1,1-Dichloroethylene 0.083 U ug/L 0,50 0.083 1 SM6200 B 11/11/19 16:35 KDM P91<0225 1,1-Dichloropropylene 0.051 U ug/L 0.50 0.051 1 SM6200 B 11/11/19 16:35 KDM P91<0225 1,2,3-Trichlorobenzene 0.40 U ug/L 0.50 0.40 1 SM6200 B 11/11/19 16:35 KDM P91<0225 1,2,3-Trichloropropane 0,14 U ug/L 0,50 0.14 1 SM6200 B 11/11/19 16:35 KDM P91<0225 1,2,4-Trichlorobenzene 0,13 U ug/L 0.50 0.13 1 SM6200 B 11/11/19 16:35 KDM P91<0225 1,2,4-Trimethylbenzene 0.054 U ug/L 0.50 0.054 1 SM6200 B 11/11/19 16.35 KDM P9K0225 1,2-Dibromo-3-chloropropane 0.17 U ug/L 2.0 0.17 1 SM6200 B 11/11/19 16:35 KDM 1391<0225 1,2-Dibromoethane 0.051 U ug/L 0.50 0.051 1 SM6200 B 11/11/19 16:35 KDM P91<0225 1.2-Dichlorobenzene 0.076 U ug/L 0.50 0.076 1 SM6200 B 11/11/19 16:35 KDM P91<0225 1.2-Dichloroethane 0.066 U ug/L 0.50 0.066 1 SM6200 B 11/11/19 16:35 KDM P91<0225 1,2-Dichloropropane 0.11 U ug/L 0,50 0,11 1 SM6200 8 11/11/19 16:35 KDM 1391<0225 1,3,5-Trimethylbenzene 0.076 U ug/L 0.50 0.076 1 SM6200 B 11/11/19 16:35 KDM P91<0225 1,3-Dichlorobenzene 0.054 U u9/L 0.50 0,054 1 SM6200 B 11/11/19 16:35 KDM P91<0225 1,3-Dichloropropane 0,043 U ug/L 0.50 0.043 1 SM6200 B 11/11/19 16:35 KDM P91<0225 1,4-Dichlorobenzene 0.050 U ug/L 0.50 0.050 1 SM6200 B 11/11/19 16:35 KDM P91<0225 2,2-Dichloropropane 0.11 U ug/L 2.0 0.11 1 SM6200 8 11/11/19 16:35 KDM P91<0225 2-Chlorotoluene 0,066 U ug/L 0.50 0.066 1 SM6200 B 11/11/19 16:35 KDM P91<0225 4-Chlorotoluene 0.050 U ug/L 0.50 0.050 1 SM6200 B 11/11/19 16:35 KDM P91<0225 4-Isopropyltoluene 0.089 U ug/L 0.50 0.089 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Acetone 2.0 J ug/L 10 0.31 1 SM6200 B 11111/19 16:35 KDM 1391<0225 Benzene 0.048 U ug/L 0.50 0.048 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Bromobenzene 0.057 U ug/L 0.50 0.057 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Bromochloromethane 0.14 U ug/L 0.50 014 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Bromodichloromethane 0,062 U ug/L 0,50 0.062 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Bromoform 0.040 U ug/L 0.50 0,040 1 SM6200 B 11/11/19 16:35 KDM P9K0225 Bromomethane 0.18 U ug/L 1.0 0.18 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Carbon Tetrachloride 0.11 U ug/L 0.50 0.11 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Chlorobenzene 0.062 U ug/L 0.50 0.062 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Chloroethane 0.22 U ug/L 0.50 0.22 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Chloroform 0.34 J ug/L 0.50 0.076 1 SM6200 B 11111119 16:35 KDM P91<0225 Chloromethane 0,079 U ug/L 0.50 0,079 1 SM6200 B 11/11/19 16:35 KDM P91<0225 cis- 1,2-Dichloroethylene 0,056 U ug/L 0.50 0,056 1 SM6200 B 11/11/19 16:35 KDM P91<0225 cis- 1, 3-Dichloropropylene 0.079 U ug/L 0.50 0.079 1 SM6200 B 11/11/19 16:35 KDM P91<0225 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/629-6364 - Fax: 704/626-0409 Page 8 of 19 Laboratory Report P R I S M Env Service aJ Solutions s 11 /1512019 Environmental Solutions 1_1h"I'll Ann - Shield Engineering, Inc. Project: Carolina Fast Mart #2 Client Sample ID: WSW-1A Attn: Kevin Stachura Prism Sample ID: 9110119-03 4301 Taggart Creek Rd. Prism Work Order: 9110119 Charlotte, NC 28208 Sample Matrix: Water Time Collected: 11/05/19 11:25 Time Submitted: 11/06/19 15:30 Parameter Result Units Report Limit MDL Dilution Factor Method Analysis Analyst Date/Time Batch ID Dibromochloromethane 0.081 U ug/L 0.50 0.0B1 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Dibromomethane 0.065 U ug/L 0.50 0.065 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Dichlorodifluoromethane 0.11 UCCV ug/L 1.0 0.11 1 SM6200 B 11/11/19 16:35 KDM P9K0225 Ethanol P7 U ug/L 200 27 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Ethylbenzene 0,061 U ug/L 0,50 0.061 1 SM6200 B 11/11/19 16,35 KDM P91<0225 Hexachlorobutadiene 0.16 U ug/L 2.0 0.16 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Isopropyl Ether 0 050 U ug/L 0.50 0.050 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Isopropylbenzene (Cumene) 0.054 U ug/L 0.50 0,054 1 SM6200 B 11/11/19 16:35 KDM P9K0225 m,p-Xylenes 0,12 U ug/L 1.0 0.12 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Methyl Butyl Ketone (2-Hexanone) 0,065 U ug/L 1.0 0.065 1 SM6200 B 11/11/19 16:35 KDM POK0225 Methyl Ethyl Ketone (2-Butanone) 0.24 U ug/L 5.0 0.24 1 SM6200 B 11/11/19 16:35 KDM P91<0225, Methyl Isobutyl Ketone 0.078 U ug/L 1.0 0.078 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Methylene Chloride 0,083 U ug/L 2.0 0.083 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Methyl-tert-Butyl Ether 0.042 U ug/L 1.0 0.042 1 SM6200 B 11/11/19 16:35 KDM P9K0225 Naphthalene 0.19 U u9/L 1.0 0.19 1 SM6200 B 11/11/19 16:35 KDM P91<0225 n-Butylbenzene 0.076 U ug/L 0.50 0.076 1 SM6200 B 11/11/19 16:35 KDM P91<0225 n-Propylbenzene 0.087 U ug/L 0.50 0.087 1 SM6200 B 11/11/19 16:35 KDM 1391<0225 o-Xylene 0.044 U ug/L 0.50 0.044 1 SM6200 B 11/11/19 16:35 KDM P9K0225 sec-Butylbenzene 0.076 U ug/L 0-50 0.076 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Styrene 0,047 U ug/L 0,50 0.047 1 SM6200 B 11/11/19 16:35 KDM P91<0225 tart-Butylbenzene 0.088 U ug/L 0.50 0.088 1 SM6200 B 11/11/19 16:35 KDM P9K0225 Tetrachloroethylene 0.098 U ug/L 0.50 0.098 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Toluene 0.044 U ug/L 0.50 0,044 1 SM6200 B 11/11/19 16:35 KDM P91<0225 trans-1,2-Dichloroethylene 0-070 U ug/L 0.50 0.070 1 SM6200 B 11/11/19 16:35 KDM P91<0225 trans- 1,3-Dichloropropylene 0.12 U ug/L 0.50 0.12 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Trichloroethylene 0,076 U ug/L 0.50 0.078 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Trichlorofluoroinethane 0,062 U ug/L 0.50 0.062 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Vinyl acetate 0.060 U ug/L 5.0 0.060 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Vinyl chloride 0.097 U ug/L 0.50 0.097 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Xylenes, total 0,15 U ug/L 1.5 0.15 1 SM6200 B 11/11/19 16:35 KDM P91<0225 Surrogate Recovery Control Limits 4-Bromofluorobenzene 98 % 70-130 Dibromofluoromethane 98 % 70-130 Toluene-d8 96 % 70-130 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0643 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 7041526-0409 Page 9 of 19 Fi M' Laboratory Report Full-Su+vrre Analyriral $ En Vimnrnenlal Solutions 11/15/2019 ,,1, .AefleRif WA M. Shield Engineering, Inc. Attn: Kevin Stachura 4301 Taggart Creek Rd. Charlotte, NC 28208 Project: Carolina Fast Mart #2 Sample Matrix: Water Client Sample ID: Trip Blank Prism Sample ID: 9110119-04 Prism Work Order: 9110119 Time Collected: 11 /05/19 00:00 Time Submitted: 11/06/19 15:30 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor Date/Time ID Volatile Organic Compounds by GC/MS 1,1,1,2-Tetrachloroethane 0.11 U ug/L 0 50 0 11 1 SM6200 B 11/11/19 15:16 KDM P91<0225 1,1,1-Trichloroethane 0,061 U ug/L 0.50 0.061 1 SM6200 B 11/11/19 15:16 KDM P9K0225 1,1,2,2-Tetrachloroethane 0.036 U ug/L 0.50 0.036 1 SM6200 B 11/11/19 15:16 KDM P91<0225 1,1,2-Trichloroethane 0.066 U ug/L 0 50 0.066 1 SM6200 B 11/11/19 15:16 KDM 1391<0225 1,1-Dichloroethane 0.083 U ug/L 0,50 0.083 1 SM6200 B 11/11/19 15:16 KDM P91<0225 1,1-Dichloroethylene 0.083 U ug/L 0.50 0.083 1 SM6200 B 11/11/19 15:16 KDM P91<0225 1,1-Dichloropropylene 0,051 U ug/L 0.50 0.051 1 SM6200 B 11/11/19 15:16 KDM 1391<0225 1,2,3-Trichlorobenzene 0.40 U ug/L 0.50 0.40 1 SM6200 B 11/11/19 15:16 KDM P9K0225 1,2,3-Trichloropropane 0.14 U ug/L 0.50 0.14 1 SM6200 B 11/11/19 15:16 KDM P91<0225 1,2,4-Trichlorobenzene 0.13 U ug/L 0.50 0.13 1 SM6200 B 11/11/19 15:16 KDM P91<0225 1,2,4-Trimethyl benzene 0,054 U ug/L 0.50 0.054 1 SM6200 B 11/11/19 15:16 KDM P91<0225 1,2-Dibromo-3-chloropropane 0.17 U ug/L 2.0 0.17 1 SM6200 B 11/11/19 15:16 KDM P91<0225 1,2-Dibromoethane 0,051 U ug/L 0.50 0,051 1 SM6200 B 11/11/19 15:16 KDM P91<0225 1,2-Dichlorobenzene 0.076 U ug/L 0.50 0,076 1 SM6200 B 11/11/19 15:16 KDM P91<0225 1,2-Dichloroethane 0,066 U ug/L 0.50 0.066 1 SM6200 B 11/11/19 15:16 KDM P91<0225 1,2-Dichloropropane 0.11 U ug/L 0.50 0.11 1 SM6200 B 11/11/19 15:16 KDM P9K0225 1,3,5-Trimethylben7ene 0.076 U ug/L 0,50 0.076 1 SM6200 B 11/11/19 15:16 KDM P91<0225 1,3-Dichlorobenzene 0.054 U ug/L 0.50 0.054 1 SM6200 B 11/11/19 15:16 KDM P91<0225 1,3-Dichloropropane 0.043 U ug/L 0.50 0.043 1 SM6200 B 11/11/19 15:16 KDM P91<0225 1,4-Dichlorobenzene 0,050 U ug/L 0.50 0.050 1 SM6200 B 11/11/19 15:16 KDM P91<0225 2,2-Dichloropropane 0.11 U ug/L 2.0 0 11 1 SM6200 B 11/11/19 15:16 KDM P91<0225 2-Chlorotoluene 0.066 U ug/L 0,50 0.066 1 SM6200 B 11/11/19 15:16 KDM P91<0225 4-Chlorotoluene 0.050 U ug/L 0.50 0.050 1 SM6200 B 11/11/19 15:16 KDM P91<0225 4-Isopropyltoluene 0.089 U ug/L 0.50 0.089 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Acetone 1.8 J ug/L 10 0.31 1 SM6200 B 11111119 15:16 KDM P9K0225 Benzene 0.048 U ug/L 0.50 0.048 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Bromobenzene 0.057 U ug/L 0,50 0.057 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Bromochloromethane 0.14 U ug/L 0.50 0.14 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Bromodichloromethane 0.062 U ug/L 0.50 0.062 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Bromoform 0.040 U ug/L 0.50 0.040 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Bromomethane 0.18 U ug/L 1.0 0.18 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Carbon Tetrachloride 0.11 U ug/L 0.50 0.11 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Chlorobenzene 0.062 U ug/L 0.50 0.062 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Chloroethane 0.22 U ug/L 0.50 0.22 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Chloroform 0,076 U ug/L 0,50 0.076 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Chloromethane 0,079 U ug/L 0.50 0 079 1 SM6200 B 11/11/19 15:16 KDM P91<0225 cis-1,2-Dichloroethylene 0,056 U ug/L 0.50 0.056 1 SM6200 B 11/11/19 15:16 KDM P91<0225 cis-1,3-Dichloropropylene 0,079 U ug/L 0.50 0.079 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Dibromochloromethane 0,081 U ug/L 0,50 0.081 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Dibromomethane 0,065 U ug/L 0.50 0.065 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Dichlorodifluoromethane 0.11 UCCv ug/L 1.0 0.11 1 SM6200 B 11/11/19 15:16 KDM P9K0225 Ethanol 27 U ug/L 200 27 1 SM6200 B 11/11/19 15:16 KDM P91<0225 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc- 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224.0543 Phone: 704/529-6364 - Toll Free Number: 1.8001529-6364 - Fax: 704/525.0409 Page 16 Of 1 9 Laboratory Report PRISM E'nwoo11-Smen al Solution s 11/15/2019 Enviinnmenial Solutions Shield Engineering, Inc. Project: Carolina Fast Mart #2 Client Sample ID: Trip Blank Attn: Kevin Stachura Prism Sample ID: 9110119-04 4301 Taggart Creek Rd, Prism Work Order: 9110119 Charlotte, NC 28208 Sample Matrix: Water Time Collected: 11/05/19 00:00 Time Submitted: 11/06/19 15:30 Parameter Result Units Report Limit MDL Dilution Factor Method Analysis Analyst Date/Time Batch ID Ethylbenzene 0.061 U ug/L 0.50 0.061 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Hexachlorobutadiene 0.16 U ug/L 2.0 0.16 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Isopropyl Ether 0,050 U ug/L 0.50 0.050 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Isopropylbenzene (Cumene) 0.054 U ug/L 0.50 0,054 1 SM6200 B 11/11/19 15:16 KDM P91<0225 m,p,Xylenes 0.12 U ug/L 1.0 0.12 1 SM6200 B 11/11/19 15:16 KDM P9K0225 Methyl Butyl Ketone (2-Hexanone) 0.065 U ug/L 1.0 0.065 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Methyl Ethyl Ketone (2-Butanone) 0.24 U ug/L 5.0 0.24 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Methyl Isobutyl Ketone 0,078 U ug/L 1.0 0.078 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Methylene Chloride 0.083 U ug/L 2.0 0.083 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Methyl-tert-Butyl Ether 0,042 U ug/L 1.0 0.042 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Naphthalene 0.19 U ug/L 1.0 0.19 1 SM6200 B 11/11/19 15:16 KDM P91<0225 n-Butylbenzene 0.076 U ug/L 0.50 0.076 1 SM6200 B 11/11/19 15:16 KDM P91(0225 n-Propylbenzene 0.087 U ug/L 0.50 0.087 1 SM6200 B 11/11/19 15:16 KDM P91<0225 o-Xylene 0,044 U ug/L 0.50 0 044 1 SM6200 B 11/11/19 15:16 KDM P91<0225 sec-Butylbenzene 0.076 U ug/L 0.50 0.076 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Styrene 0.047 U ug/L 0.50 0 047 1 SM6200 B 11/11/19 15:16 KDM P91<0225 tert-Butylbenzene 0.088 U ug/L 0.50 0.066 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Tetrachloroethylene 0.098 U ug/L 0.50 0.098 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Toluene 0.044 U ug/L 0.50 0.044 1 SM6200 B 11/11/19 15:16 KDM P91<0225 trans-1,2-Dichloroethylene 0.070 U ug/L 0.50 0.070 1 SM6200 B 11/11/19 15:16 KDM P91<0225 trans-1,3-Dichloropropylene 0.12 U ug/L 0.50 0.12 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Trichloroethylene 0.078 U ug/L 0.50 0.078 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Trichlorofluoromethane 0.062 U ug/L 0.50 0.062 1 SM6200 B 11/11/19 15:16 KDM P9K0225 Vinyl acetate 0.060 U ug/L 5,0 0,060 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Vinyl chloride 0,097 U ug/L 0,50 0,097 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Xylenes, total 0.15 U ug/L 1,5 0.15 1 SM6200 B 11/11/19 15:16 KDM P91<0225 Surrogate Recovery Control Limits 4-Bromofluorobenzene 99 % 70-130 Dibromofluoromethane 100 % 70-130 Toluene -dB 97 % 70-130 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0643 Phone: 704/529-6364 -Toll Free Number: 1.8001629-6364 - Fax: 7041525.0409 Page 11 of 19 PRISMEul r-vice Analylir. al R Fn vrronmental Solutions ne�wxem�u.v �m Shield Engineering, Inc. Project: Carolina Fast Mart #2 Attn: Kevin Stachura 4301 Taggart Creek Rd. Charlotte, NC 28208 Volatile Organic Compounds by GC/MS - Quality Control Level II QC Report 11/15/19 Prism Work Order: 9110119 Time Submitted: 11/6/2019 3:30:OOPM Reporting Spike Source %REC RPD Analyte Result Limit Units Level Result %REC Limits RPD Limit Notes Batch P9K0225 - SM6200 B Blank (P9K0225-BLK1) Prepared &Analyzed: 11/11/19 1,1,1,2-Tetrachloroethane BRL 0.50 ug/L 1.1.1-Trichloroethane BRL 0.50 ug/L 1,1,2,2-Tetrachloroethane BRL 0.50 ug/L 1,1,2-Trichloroethane BRL 0.50 ug/L 1,1-Dichloroethane BRL 0.50 ug/L 1,1-Dichloroethylene BRL 0.50 ug/L 1,1-Dichloropropylene BRL 0.50 ug/L 1,2,3-Trichlorobenzene BRL 0.50 ug/L 1,2,3-Trichloropropane BRL 0.50 ug/L 1,2,4-Trichlorobenzene BRL 0.50 ug/L 1,2,4-Trimethylbenzene BRL 0.50 ug/L 1.2-Dibromo-3-chloropropane BRL 2.0 ug/L 1,2-Dibromoethane BRL 0,5o ug/L 1,2-Dichlorobenzene BRL 0.50 ug/L 1,2-Dichloroethane BRL 0.50 ug/L 1,2-Dichloropropane BRL 0.50 ug/L 1,3,5-Trimethylbenzene BRL 0.50 ug/L 1,3-Dichlorobenzene BRL 0.50 ug/L 1.3-Dichloropropane BRL 0.50 ug/L 1,4-Dichlorobenzene BRL 0.50 ug/L 2,2-Dichloropropane BRL 2.0 ug/L 2-Chlorotoluene BRL Mo ug/L 4-Chlorotoluene BRL 0.50 ug/L 4-Isopropyltoluene BRL 0.50 ug/L Acetone BRL 10 ug/L Benzene BRL 0.50 ug/L Bromobenzene BRL 0.50 ug/L Bromochloromethane BRL 0,50 ug/L Bromodichloromethane BRL 0.50 ug/L Bromoform BRL 0.50 ug/L Bromomethane BRL 1.0 ug/L Carbon Tetrachloride BRL 0.50 ug/L Chlorobenzene BRL 0.50 ug/L Chloroethane BRL 0,50 ug/L Chloroform BRL MO ug/L Chloromethane BRL 0,50 ug/L cis-1,2-Dichloroethylene BRL 0.50 ug/L cis- 1,3-Dichloropropylene BRL 0.50 ug/L Dibromochloromethane BRL 0150 ug/L Dibromomethane BRL 0.50 ug/L Dichlorodifluoromethane BRL 1.0 ug/L Ethanol BRL 200 ug/L Ethylbenzene BRL 0.50 ug/L Hezachlorobutadiene BRL 2.0 ug/L Isopropyl Ether BRL 050 ug/L Isopropylbenzene (Cumene) BRL 0.50 ug/L This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240643 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/629-6364 - Fax: 7041525-0409 Page 12 0f 19 Level II QC Report 11/15/19 PRISM P nw.,rvicu Analytical & Envirailn-mtal Solutions Shield Engineering, Inc. Project: Carolina Fast Mart #2 Attn: Kevin Stachura 4301 Taggart Creek Rd, Charlotte, NC 28208 Volatile Organic Compounds by GC/MS - Quality Control Analyte Reporting Result Limit Units Prism Work Order: 9110119 Time Submitted: 11/6/2019 3:30:OOPM Spike Source %REC RPD Level Result %REC Limits RPD Limit Notes Batch P91(0225 - SM6200 B Blank (P9K0225-BLK1) Prepared &Analyzed: 11/11/19 m,p-Xylenes BRL 1.0 ug/L Methyl Butyl Ketone (2-Hexanone) BRL 1.0 ug/L Methyl Ethyl Ketone (2-Butanone) BRL 5.0 ug/L Methyl Isobutyl Ketone BRL 1.0 ug/L Methylene Chloride BRL 2.0 ug/L Methyl-tert-Butyl Ether BRL 1.0 ug/L Naphthalene BRL 1.0 ug/L n-Butylbenzene BRL 0.50 ug/L n-Propylbenzene BRL 0.50 ug/L o-Xylene BRL 0.50 ug/L sec-Butylbenzene BRL 0.50 ug/L Styrene BRL 0.50 ug/L tert-Butylbenzene BRL 0.50 ug/L Tetra chloroethylena BRL 0.50 ug/L Toluene BRL 0,50 ug/L trans-1,2-Dichloroethylene BRL 0.50 ug/L trans- 1,3-Dichloropropylene BRL 0.50 ug/L Trichloroethylene BRL 0.50 ug/L Trichlorofluoromethane BRL 0.50 ug/L Vinyl acetate BRL 5.0 ug/L Vinyl chloride BRL 0.50 ug/L Xylenes, total BRL 1.5 ug/L Surrogate:4-Bromofluorobenzene 48.4 ug/L 50.00 97 70-130 Surrogate: Dibromofluoromethane 496 ug/L 5000 100 70-130 Surrogate: Toluene-d8 479 ug/L 5000 96 70-130 1-CS (P9K0225-BSI) _ Prepared &Analyzed: 11/11/19 1,1,1,2-Tetrachloroethane 21.5 0.50 ug/L 20.00 108 70-130 1,1,1-Trichloroethane 22.6 0.50 ug/L 20.00 113 70-130 1,1,2,2-Tetrachloroethane 20.0 0,50 ug/L 20.00 100 70-130 1,1,2-Trichloroethane 21.1 0.50 ug/L 20.00 106 70-130 1,1-Dichloroethane 21.3 0,50 ug/L 20.00 106 70-130 1,1-Dichloroethylene 22.1 0,50 ug/L 20.00 111 70-130 1,1-Dichloropropylene 22.6 0.50 ug/L 20,00 113 70-130 1,2,3-Trichlorobe nzene 22.4 0.50 ug/L 20.00 112 70-130 1,2,3-Trichloropropane 20.7 0.50 ug/L 20,00 103 70-130 1,2,4-Trichlorobe nzene 21.5 0.50 ug/L 20,00 107 70-130 1,2,4-Trimethylbenzene 20.7 0.50 ug/L 20.00 103 70-130 1,2-Dibromo-3-chloropropane 22.1 2.0 ug/L 20.00 111 70-130 1,2-Dibromoethans 20.9 0.50 ug/L 20-00 104 70-130 1,2-Dichlorobenzene 20.6 0.50 ug/L 20.00 103 70-130 1.2-Dichloroethane 20.4 0,50 ug/L 20.00 102 70-130 1,2-Dichloropropane 20.6 0,50 ug/L 20.00 103 70-130 1,3,5-Trimethylbenzene 20.8 0.50 ug/L 20.00 104 70-130 1,3-Dichlorobenzene 20.4 0.50 ug/L 2000 102 70-130 1,3-Dichloropropane 21.3 0.50 ug/L 20.00 107 70-130 1,4-Dichlorobenzene 20.3 0.50 ug/L 20.00 101 70-130 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 _ Phone: 704/529.6364 - Toll Free Number: 1.8001529-6364 - Fax: 704/525.0409 Page 13 of 19 r]RISM PUI65n�ricn Analytical & �--� Envirnrvrnen[al Solutions Shield Engineering, Inc. Attn: Kevin Stachura 4301 Taggart Creek Rd. Charlotte, NC 28208 Project: Carolina Fast Mart #2 Volatile Organic Compounds by GC/MS - Quality Control Analyte Batch P9K0225 - SM6200 B Reporting Result Limit Units Level II QC Report 11 /15/19 Prism Work Order: 9110119 Time Submitted: 11/6/2019 3:30:OOPM Spike Source %REC RPD Level Result %REC Limits RPD Limit Notes LCS (P9K0225-BS1) Prepared &Analyzed: 11/11/19 2,2-Dichloropropane 23.1 2.0 ug/L 20.00 115 70-130 2-Chlorotoluene 20.1 0.50 ug/L 20.00 101 70-130 4-Chlorotoluene 20.0 0.50 ug/L 20.00 100 70-130 4-Isopropyltoluene 21.8 0.50 ug/L 20.00 109 70-130 Acetone 41.7 10 ug/L 40.00 104 40-160 Benzene 20.7 0.50 ug/L 20.00 104 70-130 Bromobenzene 19.8 0,50 ug/L 20.00 99 70-130 Bromochloromethane 21.8 0.50 ug/L 20.00 109 70-130 Bromodichloromethane 21.7 0.50 ug/L 20,00 109 70-130 Bromoform 22.9 0.50 ug/L 20.00 114 70-130 Bromomethane 22A 1.0 ug/L 20.00 112 60-140 Carbon Tetrachloride 23.3 0.50 ug/L 20.00 116 70-130 Chlorobenzene 20.3 0,50 ug/L 20.00 102 70-130 Chloroethane 22.6 0,50 ug/L 20.00 113 60-140 Chloroform 21.3 0.50 ug/L 20.00 107 70-130 Chloromethane 21.6 0.50 ug/L 20.00 108 60-140 cis-1,2-Dichloroethylene 19.4 0.50 ug/L 20.00 97 70-130 cis-1,3-Dichloropropylene 22.6 0.50 ug/L 20,00 114 70-130 Dibromochloromethane 219 0.50 ug/L 20,00 110 70-130 Dibromomethane 20.6 0.50 ug/L 20.00 103 70-130 Dichlorodifluoromethane 26.1 1.0 ug/L 20.00 130 60-140 Ethanol 502 200 ug/L 500.0 100 60-140 Ethylbenzene 21.2 0.50 ug/L 20.00 106 70-130 Hexachlorobutadiene 22.3 2.0 ug/L 20.00 111 70-130 Isopropyl Ether 19.3 0.50 ug/L 20.00 97 70-130 Isopropylbenzene (Cumene) 21.6 0.50 ug/L 20,00 108 70-130 m,p-Xylenes 42.8 1.0 ug/L 40.00 107 70-130 Methyl Butyl Ketone (2-Hexanone) 20.7 1.0 ug/L 20,00 103 60-140 Methyl Ethyl Ketone (2-Butanone) 21.7 5.0 ug/L 20.00 108 60-140 Methyl Isobutyl Ketone 20.6 1.0 ug/L 20,00 103 60-140 Methylene Chloride 18.8 2.0 ug/L 20.00 94 70-130 Methyl-tert-Butyl Ether 21.6 1.0 ug/L 20.00 108 70-130 Naphthalene 221 1.0 ug/L 20.00 110 70-130 n-Butylbenzene 21.6 0.50 ug/L 20.00 108 70-130 n-Propylbenzene 207 0.50 ug/L 2000. 103 70-130 o-Xylene 21.3 0.50 ug/L 20.00 107 70-130 sec-Butylbenzene 219 0.50 ug/L 20.00 109 70-130 Styrene 22 1 0.50 ug/L 20,00 110 70-130 tart-Butylbenzene 21.7 0.50 ug/L 20.00 109 70-130 Tetrachloroethylene 23 0 0.50 ug/L 20.00 115 70-130 Toluene 21.1 0.50 ug/L 20.00 106 70-130 trans-1,2-Dichloroethylene 20.9 0.50 ug/L 20.00 104 70-130 trans-1,3-Dichloropropylene 23.0 0.50 ug/L 20.00 115 70-130 Trichloroethylene 20.9 0.50 ug/L 20.00 105 70-130 Trichlorofluoromethane 25.5 0.50 ug/L 20.00 127 60-140 Vinyl acetate 22.0 5.0 ug/L 20.00 110 60-140 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 14 0f 19 P I %� Env Servico Analytical s '�i Enviranmuntal Solutions . v,r,.rv„ 11 w�. Shield Engineering, Inc. Project: Carolina Fast Mart #2 Attn: Kevin Stachura 4301 Taggart Creek Rd. Charlotte, NC 28208 Volatile Organic Compounds by GC/MS - Quality Control Analyte Reporting Result Limit Units Level II QC Report 11/15/19 Prism Work Order: 9110119 Time Submitted: 11/6/2019 3:30:OOPM Spike Source %REC RPD Level Result %REC Limits RPD Limit Notes Batch P9K0225 - SM6200 B LCS (P9K0225-BS1) _ Prepared &Analyzed: 11/11/19 Vinyl chloride 24.1 0.50 ug/L 20.00 120 60-140 Xylenes, total 64.2 1.5 ug/L 60.00 107 70-130 Surrogate:4-Bromofluorobenzene 48.0 ug/L 50.00 96 70-130 Surrogate: Dibromofluoromethane 49.8 ug/L 50.00 100 70-130 Surrogate: Toluene-d8 48.5 ug/L 50.00 97 70-130 LCS Dup (P9K0225-8_S_D_1) Prepared &Analyzed: 11 /11 /19 1.1,1,2-Tetrachloroethane 21.0 0.50 ug/L 20.00 105 70-130 2 20 1.1,1-Trichloroethane 22.6 0,50 ug/L 20.00 113 70-130 0.09 20 1,1,2,2-Tetrachloroethane 19.7 0.50 ug/L 20.00 98 70-130 2 20 1,1,2-Trichloroethane 20.8 0.50 ug/L 20.00 104 70-130 1 20 1,1-Dichloroethane 21.2 0.50 ug/L 20.00 106 70-130 0.2 20 1,1-Dichloroethylene 22.6 0.50 ug/L 20,00 113 70-130 2 20 1,1-Dichloropropylene 23 0 0.50 ug/L 20.00 115 70-130 1 20 1_2,3-Trichlorobenzene 22.2 0,50 ug/L 20.00 ill 70-130 0.9 20 1,2,3-Trichloropropane 20.6 0.50 ug/L 20.00 103 70-130 0.3 20 1,2,4-Trichlorobenzene 21.2 0.50 ug/L 20.00 106 70-130 1 20 1,2,4-Trimethylbenzene 20 8 0.50 ug/L 20,00 104 70-130 0.5 20 1,2-Dibromo-3-chloropropane 21.5 2.0 ug/L 20.00 107 70-130 3 20 1,2-Dibromoethane 20.5 0.50 ug/L 20.00 103 70-130 2 20 1,2-Dichlorobenzene 20.6 0.50 ug/L 20.00 103 70-130 0 20 1,2-Dichloroethane 19.9 0.50 ug/L 20.00 100 70-130 2 20 1,2-Dichloropropane 20.4 0.50 ug/L 20.00 102 70-130 0.7 20 1,3,5-Trimethylbenzene 20 9 0.50 ug/L 20,00 104 70-130 0.2 20 1,3-Dichlorobenzene 201 0.50 ug/L 20,00 101 70-130 1 20 1,3-Dichloropropane 20.8 0.50 ug/L 20.00 104 70-130 2 20 1,4-Dichlorobenzene 20.3 0.50 ug/L 20.00 102 70-130 0,2 20 2,2-Dichloropropane 22.8 2.0 ug/L 20,00 114 70-130 1 20 2-Chlorotoluene 20.1 0.50 ug/L 20.00 100 70-130 0.2 20 4-Chlorotoluene Ml 0.50 ug/L 20.00 100 70-130 0.7 20 4-Isopropyltoluene 21.9 0.50 ug/L 20.00 109 70-130 0.09 20 Acetone 40.5 10 ug/L 40.00 101 40-160 3 20 Benzene 20.8 0.50 ug/L 20.00 104 70-130 0A 20 Bromobenzene 19.5 0.50 ug/L 20.00 98 70-130 1 20 Bromochloromethane 21.1 0.50 ug/L 20.00 106 70-130 3 20 Bromodichloromethane 21.9 0.50 ug/L 20.00 109 70-130 0.7 20 Bromoform 22.8 0.50 ug/L 20.00 114 70-130 0.4 20 Bromomethane 23.1 1.0 ug/L 20.00 116 60-140 3 20 Carbon Tetrachloride 23.5 0.50 ug/L 20.00 117 70-130 0.7 20 Chlorobenzene 20.2 0.50 ug/L 20.00 101 70-130 0.5 20 Chloroethane 21.8 0.50 ug/L 20.00 109 60-140 4 20 Chloroform 21.4 0.50 ug/L 20.00 107 70-130 0,6 20 Chloromethane 22.2 0.50 ug/L 20.00 111 60-140 3 20 cis-1,2-Dichloroethylene 19.6 0.50 ug/L 20.00 98 70-130 0.8 20 cis- 1,3-Dichloropropylene 22.8 0.50 ug/L 20.00 114 70-130 0.04 20 Dibromochloromethane 21.2 0.50 ug/L 20.00 106 70-130 3 20 Dibromomethane 20.8 0.50 ug/L 20.00 104 70-130 0.8 20 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/526-0409 Page 15 of 19 P R I S n ■, Envir omen Analytical s l V, � Envlrchnlenlal Solutions - -... �nWs,elVriwB. Mlu Shield Engineering, Inc. Project: Carolina Fast Mart #2 Attn: Kevin Stachura 4301 Taggart Creek Rd. Charlotte, NC 28208 Volatile Organic Compounds by GC/MS - Quality Control Level II QC Report 11/15/19 Prism Work Order: 9110119 Time Submitted: 11/6/2019 3:30:OOPM Reporting Spike Source %REC RPD Analyte Result Limit Units Level Result %REC Limits RPD Limit Notes Batch P9KO225 - SM6200 B LCS Du_p (P9K0225-I3SD_1)_ _ _ _ Prepared &Analyzed: 11 /11 /19 _ Dichlorodifluoromethane 26.4 1.0 ug/L 20.00 132 60-140 1 20 Ethanol 500 200 ug/L 500,0 100 60-140 0.4 20 Ethylbenzene 21,0 0.50 ug/L 20.00 105 70-130 1 20 Hexachlorobutadiene 22.1 2.0 ug/L 20.00 111 70-130 0.6 20 Isopropyl Ether 19.6 0.50 ug/L 20.00 98 70-130 1 20 Isopropylbenzene (Cumene) 21.8 0,50 ug/L 20.00 109 70-130 1 20 m,p-Xylenes 43.1 1.0 ug/L 40.00 108 70-130 0.5 20 Methyl Butyl Ketone (2-Hexanone) 20.5 1.0 ug/L 20.00 102 60-140 1 20 Methyl Ethyl Ketone (2-Butanone) 20.0 5.0 ug/L 20.00 100 60-140 8 20 Methyl Isobutyl Ketone 20.2 1.0 ug/L 20.00 101 60-140 2 20 Methylene Chloride 19.0 2.0 ug/L 20.00 95 70-130 0.6 20 Methyl-tert-Butyl Ether 21.8 1.0 ug/L 20.00 109 70-130 0.8 20 Naphthalene 21.4 1.0 ug/L 20.00 107 70-130 3 20 n-Butylbenzene 21.6 0.50 ug/L 20.00 108 70-130 0.09 20 n-Propylbenzene 20.7 0.50 ug/L 20.00 103 70-130 0,05 20 o-Xylene 21.1 0.50 ug/L 20,00 106 70-130 1 20 sec-Butylbenzene 21.8 0.50 ug/L 20,00 109 70-130 0.2 20 Styrene 21.6 0.50 ug/L 20.00 108 70-130 2 20 tert-Butylbenzene 21.9 0.50 ug/L 20.00 109 70-130 0.8 20 Tetrachloroethylene 22.8 0,50 ug/L 20.00 114 70-130 0.9 20 Toluene 21.3 0.50 ug/L 20.00 106 70-130 0.8 20 trans-1,2-Dichloroethylene 20.8 0.50 ug/L 20.00 104 70-130 0.5 20 trans-1,3-Dichloropropylene 23.1 0.50 ug/L 20.00 115 70-130 0.2 20 Trichloroethylene 20.9 0.50 ug/L 20.00 104 70-130 0.05 20 Trichlorofluoromethane 25.0 0.50 ug/L 20.00 125 60-140 2 20 Vinyl acetate 21.9 5.0 ug/L 20,00 110 60-140 0.3 20 Vinyl chloride 23.8 0.50 ug/L 20.00 119 60-140 1 20 Xylenes, total 64,2 1.5 ug/L 60.00 107 70-130 0.02 20 Surrogate:4-Bromofluorobenzene 46.5 ug/L 50,00 97 70-130 Surrogate: Dibromofluoromethane 49.9 ug/L 50.00 100 70-130 Surrogate: Toluene -de 48.5 ug/L 50.00 97 70-130 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 7041629-6364 - Toll Free Number: 1-800/529.6364 - Fax: 7041525-0409 Page 16 of 19 Level II QC Report I /� rnll-Suoq;oo Analytical a 11 /15/19 41I! EnvlrArimenlal Solutlonc Shield Engineering, Inc. Project: Carolina Fast Mart #2 Prism Work Order: 9110119 Attn: Kevin Stachura Time Submitted: 11/6/2019 3:30:OOPM 4301 Taggart Creek Rd. Charlotte, NC 28208 Volatile Organic Compounds by GC/ECD - Quality Control Reporting Spike Source %REC RPD Analyte Result Limit Units Level Result %REC Limits RPD Limit Notes Batch P9K0194 - 504.1 Blank (P9K0194-BLK1) Prepared &Analyzed: 11/11/19 1.2-Dibromoethane (EDB) BRL 0 020 ug/L LCS (P9K0194-BS1) Prepared &Analyzed: 11/11/19 1,2-Dibromoethane (EDB) 0.199 0.020 ug/L 0.2500 80 70-130 1,2-Dibromo-3-chloropropane 0.196 0.020 ug/L 0.2500 78 70-130 LCS Du;p TP 1<0194-BSO1) Prepared &Analyzed: 11/11/19 1,2-Dibromoethane (EDB) 0.314 0.020 ug/L 0.2500 126 70-130 45 1,2-Dibromo-3-chloropropane 0.282 0.020 ug/L 0.2500 113 70-130 36 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-8001629.6364 - Fax: 704/625.0409 20 D 20 D Page 17 of 19 Ii Foll-Swyl— Analytical & En Vlrenmonial Solutions �`- Ia„1,,,,, , .. Shield Engineering, Inc. Attn: Kevin Stachura 4301 Taggart Creek Rd. Charlotte, NC 28208 Total Metals - Quality Control Analyte Project: Carolina Fast Mart #2 Level II QC Report 11/15/19 Prism Work Order: 9110119 Time Submitted: 11/6/2019 3:30:OOPM Reporting Spike Source %REC RPD Result Limit Units Level Result %REC Limits RPD Limit Notes Batch 1391<0164 - 3005A Blank IP9K0164-BLK1) Prepared &Analyzed: 11/08/19 Lead BRL 0 0010 mg/L LCS (P9K0164-BS1) Prepared &Analyzed: 11/08/19 Lead 0,0983 0.0010 mg/L 0.1000 98 80-120 Matrix Spike (P9K0164-MS1y Source: 9110119-01 Prepared &Analyzed: 11/08/19 _ v 0.100 0.0010 mg/L 0.1000 0.000572 99 75-125 Matrix Spike Dup (P9K0164-MSD1) Source: 9110119-01 _ Prepared &Analyzed: 11/08/19 0.0983 0,0010 mg/L 0.1000 0.000572 98 75-125 2 20 Post Spike (P9K0164-PS1) Source: 9110119-01 Prepared &Analyzed: 11/08/19 Lead 96.7 ug/L 100.0 0.572 96 80-120 Sample Extraction Data Prep Method: 3005A Lab Number Batch Initial Final Date/Time 9110119-01 P91<0164 50 mL 50 mL 11/08/19 9:02 9110119-02 P91<0164 50 mL 50 mL 11/08/19 9:02 9110119-03 P91<0164 50 mL 50 mL 11/0B/19 9:02 Prep Method: 504.1 Lab Number Batch Initial Final Date/Time 9110119-01 P91<0194 33.8 mL 35 mL 11/11/19 9:35 9110119-02 P9K0194 34.2 mL 35 mL 11/11/19 9:35 9110119-03 1`91<0194 34A mL 35 mL 11/11/19 9:35 Prep Method: SM6200 B Lab Number Batch Initial Final DateMme 9110119-01 1`91<0225 10 mL 10 mL 11/11/19 10:05 9110119-02 P91<0225 10 mL 10 mL 11/11/19 10:05 9110119-03 P91<0225 10 mL 10 mL 11/11/19 10:05 9110119-04 P91<0225 10 mL 10 mL 11/11/19 10:05 This report should not be reproduced, exc@pt in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0643 Phone: 7041629-6364 - Toll Free Number: 1-800/529-6364 - Fax: 7041525-0409 Page 18 0f 19 1 I L i S M I Full -Service Analytical s Environmental Solutions - .AHGR�TO-ttFS, qIF 449 Springbrook Road • Charlotte, NC 28217 Phone 7041529-6364 ,• Fax: 7441525-D409 r � Client Company Name: h I {+i,ne� )h� Report TolContact Name: K2y1• �+KCkvr:. Reporting Address: L( fJ) Fr : c•�i I�� CkTrk0 _y 112 fi�e. CHAIN OF CUSTODY RECORD PAGE i OF 1 QUOTE # TO ENSURE PROPER BILLING: �.�1 Project Name: CGt 3 ` t rY, Ir- _ Short Hold Analysis: (Yes) WW UST Project: k_e3l) (NO) `Please ATTACH any project speck reporting (QC LEVEL 1 II lil IV) provisions andlor QC Requirements t Invoice To: Address: YES NO N/A Samples INTACT upon arrival? i Received ON WET ICE? PROPER PRESERVATIVES indicated? Received WITHIN HOLDING TIMES? CUSTODY SEALS INTACT? T /_ VOLATILES reed W/OUT HEADSPACE? PROPER CONTAINERS used? TEMP: Therm fD: E� ! Observed: — s I °C ; C.c r L' Phone: ' P4` S`ttry` 16`1 i Fa Yes),(No): Purchase Order No./Billing Reference t`f fl�14 ? Email Address: K5 14 C�Lf:. j�ir{� IaY1r i+y . CJ�k Requested Due Date ❑ 1 Day ❑ 2 Days ❑ 3 Days ❑ 4 Days ❑ 5 Days EDD Type. PDF_Excel _Other _ "Working Days" ❑ 6-9 Days Standard 10 days Z.,Rush Work Must Be Pre -Approved Site Location Name: �' r4l .),V. % Samples received after 14.00 will be processed next business day. TO BE FILLED IN BY CLIENTISAMPLING PERSONNEL .i Certification: NELAC DOD FL NC SC OTHER NIA Site Location Physical Address: �e , Turnaround time is based on business days, excluding weekends and holidays. (SEE REVERSE FOR TERMS 8 CONDITIONS REGARDING SERVICES RENDERED BY PRISM LABORATORIES, INC. TO CLIENT) Water Chlorinated: YES_ NO Sample Iced Upon Collection: YES ENO_ TIME MATRIX SAMPLE CONTAINER CLIENT DATE COLLECTED (SOIL, SAMPLE DESCRIPTION COLLECTED MILITARY WATER OR HOURS SLUDGE) SEE• BE OW NO. SIZE - ANALYSIS REQUESTED PRESERVA- :J 4, ' ' REMARKS TIMES S� Y- /� / PRISM LAB ID NO. -- v ll l3> - i ! F of/ o l� I �`A 017 l A 1 � I i I , I Sanpler's Signature J)Uk I Sampled By (Print Name)-r k C� all r I Affiliation Upon relinquishing, this 6hain of Custody is your authorization for Prism to proceed with the analyses as requested above. Any changes must be submitted in writing to the Prism Project Manager. There will be charges for any cl4anges after analyses have been initialized. R?Nrquished Br tSignaiure; Received Bye (Signature) ate ry(Houn; ite ! Additional Comments: S 7 Relirqurshed By: tSs gnaturel Received By: (S linatum) ate Site ^ Field Tech Fee: _U timm-4 By fstgna:uro) Received For PremLabzgtoms By Date A �" ' � %� \ V— + r� Mileage: (D of Shipmert NOTE: ALL SAMPLE I.ERS ULD BE TAPED SHUT S ODY SEALS FOR TRAMP ATION TO THE LABORA RY. C Grate No SAMPLES ARE NOT CEPTEO AND VERIFIED AGAINST CDC UNTIL RECEIVED AT THE LABORATORY. °I p Ez ❑UPS ❑Hand-delivereG Prism Field Service ❑ 07her llu�j UST: GROUNDWATER: DRINKING WATER: SOLID WASTE: RCRA: CERCLA LANDFILL OTHER: TES: ❑SC� ❑NC ❑SC ❑NC ❑SC ❑NC ❑SC ❑NC ❑SC ❑NCOSCI ❑NC El SC ❑NC ❑SCI ❑NC ❑SC _ Ell - — Cl_ ❑ I ❑ D ❑ ❑ I❑ "CONTAINER TYPE CODES: A = Amber C = Clear G= Glass P = Plastic-, TL = Teflon -Lined Cap VOA = Volatile Organics Analysis (Zero Head Space) 0RiGlfvAl APPENDIX B Carolina Fast Mart #2 Calibration and Field Measurment Log Field Meter YSI Pro Plus Serial # 15C100265 Calibration Standard Pre -Calibration Read Calibration Read Post -Sample Read pH 7 7 7.03 7 7.05 p H 4 4 4.01 4 4 pH 10 10 10.09 10 10.06 Spec Cond (us/cm) 1413 1374 1413 1395 ORP (mVolts) 200 203 200 205 Field Measuremnt Log ID DO pH Spec Cond (us/cm) Temp (°C) ORP (mV) MW-4 1.77 10.96 452 22.4 -6.6 MW-5 3.14 7.17 514.4 23.1 261.4 WSW-1A 3.57 6.47 173.7 18.0 304.4