Loading...
HomeMy WebLinkAboutCCB0058a_InspectionReport_20190710STRUCTUAL FILL COAL ASH INSPECTION Notification Number/Site Name: CCB0058a/Randy Vann Property County: Nash Date of Inspection / Site Visit: July 10, 2019 and November 13, 2019 Inspection Performed by (Inspector / Division): Elizabeth Werner, Davy Conners and Benjamin Jackson (DWM) Physical Address / Crossroads of Location / GPS Location: 401, 411, 421 and 431 S Wesleyan Blvd, Rocky Mounty, NC 27803; GPS: 35.947519,-77.828527 Size of Structural Fill: Unknown, pre 1994 <10,000 cubic yards (CY) Between 10,000 and 100,000 CY >100,000 CY Landowner verified: See Additional Comments and Figure 1, Parcel Numbers. Current use of site? Has use changed from last inspection? Are there any areas of exposed ash? Design concerns (if applicable) This site is paved and has the Maple Creek Plaza shopping center on it. What is the proximity of the structural fill to receptors? Private Dwellings — no, see Figure 2, Proximity Map. Community Centers — no. Surface Water Features 50' (Lakes, Ponds, Wetlands, Streams) — yes, depending on the location of the edge of fill, Maple creek might be as little as 40 feet from the fill, see Figure 3, Wetlands Map. Water Supply Wells 100'/500' (Public and Private) - unknown Desktop Receptor Check Seasonal high groundwater table — unknown, pre-1994 100 year / 500 year floodplain — yes, see Figure 4, Flood Risk Map. Are there any known utilities in close proximity to, within and/or beneath the fill area? — yes, powerlines run along the road, near the fill Page 1 of 9 Revised 2019 supplemental SF site inspection STRUCTUAL FILL COAL ASH INSPECTION Past Noted Violations: (What were they and were the violations resolved?) None. Additional Comments: On July 17, 1990 Reuse Technology submitted a letter of request to use coal ash as structural fill on approximately 3 acres of commercial property Rocky Mount, NC. In the letter of request, the generators of the ash were specified as Cogentrix's plants and the proposed start date of the project was August 1, 1990. On August 22, DEQ (formerly DEHNR) approved the reuse of coal ash at the site. The site is referred to in the letters as the Randy Vann Property and Randy Vann is carbon copied on the approval letter. This site was closed prior to Jan 1994, therefore there is no notice of coal combustion by-products recorded with the Register of Deeds. Based on our files and the description of the property, the site is located on the property described in Nash County Deed book 1308 Page 81, deeded to Kelly Randolph Vann and wife, Rebecca Davis Vann, dated June 1, 1990. The property in this deed is 4.23 acres and is a parcel of land lying on the east side of US Highway 301, the south side of Maple Creek and the west side of the Tar River. This parcel of land has been subdivided into four parcels: 047707, 047708, 004631, and 046293 (see Figure 1). The owners of the parcels are as follows: 047707 (431 S Wesleyan Blvd) and 044631 (411 S Wesleyan Blvd): Kelly Randolph Vann and wife, Rebecca Davis Vann (Deed 1308/81) 129 Candlewood Rd Rocky Mount, NC 27804 047708 (421 S Wesleyan Blvd): Yard Dog Properties LLC (Deed 2989/299) 421 S Wesleyan Blvd Rocky Mount, NC 27803 046293 (401 S Wesleyan Blvd): Steven E Luper, Jr. (Deed 1997/1019) 2913 Old Mill Rd Rocky Mount, NC 27803 Page 2 of 9 Revised 2019 supplemental SF site inspection STRUCTUAL FILL COAL ASH INSPECTION 040 03 8 04 62 93 --4117.07 ' 4�, . 1 .... i r, 04747 F eke 1t,11in6. t I Figure 1: Parcel Numbers Davy Conners, DWM/Solid Waste Section Inspector Name and Division/Section These pope ties make up the Randy Vann Pr per (CCB0058a) 919) 707-8290 Phone Number Page 3 of 9 Revised 2019 supplemental SF site inspection STRUCTUAL FILL COAL ASH INSPECTION Pictures r ' IA111A11 c� c o'�.• - - xr ^owr' Belch Bi .' i 1:k Figure 2: Proximity Map t Page 4 of 9 Revised 2019 supplemental SF site inspection STRUCTUAL FILL COAL ASH INSPECTION �r y Y it .. 1 Figure 3: Wetlands Map, approximate area of CC80058a outlined in orange Page 5 of 9 Revised 2019 supplemental SF site inspection STRUCTUAL FILL COAL ASH INSPECTION National Flood Hazard Layer FIRMette 0 250 S00 1,000 1,500 2,000 Figure 4: Flood Risk Map, approximate area of CC80058a outlined in orange ,FFt FEMA Legend xxnaln ease Flood ElermtlAn (BFEJ SPECIAL FLOOD WNh RFEa Depth iem aF. ao.iw. tiE. ut HAZARDAREAS Regulalary Floudaay D.2 Annual Chance Bondi Hazard. A eas d1%annual chance flood with a.erage depin yeas tnan one roar or frith drai.nage areas of teas Iran one aqua re We= wture �M""OHM 1%Rnnual ` cnanre rmoo nex, Area wllh Rm ucetl Roetl Risk dae to RHER AREAS OF .� Lea'ee-See Hotel. xo•ea FLOOD HAZARD r Area wIM Flom Rakdue to Levee_.. c Area of MM1naal Flom Harard ETrectl` LOMRs OTHER AREAS Area of Unnet—War! Floor HBmM GMERAI ---- C-nnel, LUNerL or Stone Sewer STRUCTURES r r Levee. pNe, or Flondwall nS Cross Secnona Mth 1%A11111 Chance Waler surl.- El—M.. o- - - Coaatal Tfansect --- Sam FFnod EI—Mon LIhe 4UE) Lm It of Study - ]Ilrlsd Icuo h Nan Iadary _.._ Coaatel Trenoeet Baseline OTEIER - Pr Mle MwAne FEATURES Iydragrapnk Feature DIVWI Data RvallaRle W DlgNal Data AraheGe MAP PAHELS unmapped p Tne MI n dspl" on me map Is an a"roWmale 7 point selected by Ine user and does nol repreaent an authodtatice W"&ty loc jan- THa map cw"p wlln FEMR's aoo hoards for the use or dlgitoI flootl maps H If t nol Vold as tleacnhed Me - TM hammap shown complk with FEMA's haaemap acaureq standards The rood hamM Inlormauon Is decked mreny from Ire authonarove NFHL a�ab sWAces M—Ided hf RM - ms map erportetl on 9. 3h: 2019 at 123E 58 PM em does no! reflect.no.@-or amemm-2 sub".emm lhlsd and Hme. Tne MEH . and ettenNve Inlormallon may mange or — me 5aperse,ad by new data —r Ilme. INS map Image Is vom N the one or more of the rdlomng map elemenre do not appear_ aasemap Imagery.nootl zone laeeb. legend, scale bar. map needml dale. canmunlry IdenHners, FIRA1 panel m`rnWr. and FIRM eifective date. Map Imagesrm mapped and unmodernf-d areas cannot Me —d for regleatory purposes. Page 6 of 9 Revised 2019 supplemental SF site inspection STRUCTUAL FILL COAL ASH INSPECTION Page 7 of 9 Revised 2019 supplemental SF site inspection STRUCTUAL FILL COAL ASH INSPECTION Page 8 of 9 Revised 2019 supplemental SF site inspection STRUCTUAL FILL COAL ASH INSPECTION Page 9 of 9 Revised 2019 supplemental SF site inspection