HomeMy WebLinkAboutCCB0010_LanierPropertyProject_INSP_20191121STRUCTUAL FILL
COAL ASH INSPECTION
Page 1 of 6 Revised 2019 supplemental SF site inspection
ID No. and Site Name: CCB0010 Lanier Property Project
County: Brunswick County
Date of Inspection / Site Visit: November 21, 2019 and January 22, 2020
Inspection Performed by (Inspector / Division): Liz Patterson, Ben Jackson/ DWM, Solid Waste Section
Physical Address / Crossroads of Location / GPS Location: Lanier Coal Ash Site Field at end of Turceau Trail (off
Greenhill Rd.) Leland, NC/ N: 34.16058 W: -78.13893
Size of Structural Fill:
<10,000 cubic yards (CY)
XBetween 10,000 and 100,000 CY
>100,000 CY
Landowner verified:
Mr. William D. Lanier
917 Greenhill Road, NE
Leland, NC 28451
Current use of site? Has use changed from last inspection? Are there any areas of exposed ash?
Design concerns (if applicable)
Ash located under a vegetated field to allow access road through property. Current use has not changed since last
inspection on December 30. 2009.
What is the proximity of the structural fill to receptors?
Private Dwellings – yes, see Figure 2: Proximity Map
Community Centers - none
Surface Water Features 50’ (Lakes, Ponds, Wetlands, Streams) - none
Water Supply Wells 100’/500’ (Public and Private) - none
Desktop Receptor Check
Seasonal high groundwater table - unknown
100 year / 500 year floodplain – Area of minimal flood hazard (Zone X), see Figure 3: Flood Risk Map
Are there any known utilities in close proximity to, within and/or beneath the fill area? unknown
STRUCTUAL FILL
COAL ASH INSPECTION
Page 2 of 6 Revised 2019 supplemental SF site inspection
Past Noted Violations: (What were they and were the violations resolved?)
NONE
Additional Comments:
The ash is located under a vegetated field. The ash volume is 30,000 cubic yards. The project was completed in
2000. The area is covered with healthy stand of pines with no apparent ash migration. Files indicate the deed
recordation has occurred, as required.
Figure 1: Structural Fill Location
STRUCTUAL FILL
COAL ASH INSPECTION
Page 3 of 6 Revised 2019 supplemental SF site inspection
Figure 2: Proximity Map
STRUCTUAL FILL
COAL ASH INSPECTION
Page 4 of 6 Revised 2019 supplemental SF site inspection
Figure 3: Flood Risk Map
Liz Patterson, DWM/Solid Waste Section_____ 910-796-7405
Inspector Name and Division/Section Phone Number
STRUCTUAL FILL
COAL ASH INSPECTION
Page 5 of 6 Revised 2019 supplemental SF site inspection
Pictures
Gate securing area so no trespassing for hunting occurs
STRUCTUAL FILL
COAL ASH INSPECTION
Page 6 of 6 Revised 2019 supplemental SF site inspection
The area is covered with healthy stand of pines with no apparent ash migration.