Loading...
HomeMy WebLinkAbout0601_Avery_MSWLF_LFG_FID1386876_20200103DocuSign Envelope ID: 1E5C5E84-C12A-4FED-8723-F8CC375A1B6B SMITH{ GARDNER ENGINEERS i• - I • • •S � F • : Li i i♦ Dear Ms. Drummond: ADORESS TEL WEB 14 N. Boylan Avenue, Raleigh NC 27603 919.828.0577 www.smithgardnerinc.com On behalf of Avery County (County), Smith Gardner, Inc. (S+G) is pleased to present this report regarding the operation and maintenance (O&M) of the Avery County Closed MSW Landfill (Permit No. 06-01) Landfill Gas Collection and Control System (LFGCCS), and the perimeter monitoring probes for the time period July 2019 through December 2019. Site details are provided below. IIVC-8; R110.MII:::'_I Based on previous monitoring events, repairs were deemed necessary to address air intrusion into the system, as well as broken laterals running from wells to monitoring probes. Repairs to the system were made in August 2019 and include: 1. Repair of the drain line running from the flare station to the condensate tank; and, 2. Repair of laterals connecting select monitoring probes to wellfield. Figure 1 (attached) identifies the wellfield and monitoring network, as well as the location of these repairs. The drain line was repaired by excavating around the condensate tank, then removing and replacing the one (1) inch PVCdrain line. Three monitoring probes (P1, P3, and P7) are connected via two (2) inch PVC pipe to extraction wells, allowing vacuum to be pulled on the probes. Previously, these lines were exposed which led to breaks in the line from weather and mowing. Repairs of these lines included repairing broken or disjointed sections of pipe. Once all laterals were determined to be completely jointed, the three (3) laterals were buried. DocuSign Envelope ID: 1E5C5E84-C12A-4FED-8723-F8CC375A1B6B Ms. Drummond January 3, 2020 Page 2 of 4 Wel I field and flare station data are provided in the attached Tables 1 through 6. 0o W 1 through W 10: S+G performed methane (CH4), oxygen (02), carbon dioxide (CO2), and pressure monitoring. S+G observed several wellheads that may require repair or replacement in the near future. S+G is working with the County on a plan for this work. 0o Orifice Plates: S+G continues to evaluate orifice plate sizes at wells W-5, W-7, W- 9, and W-10 during each site visit. LFG flow potential at these locations continues to remain stable, the correct orifice plate sizes are currently installed and no changes were made. 0o Condensate Tank: The condensate tank liquid level was observed and was at an acceptable level during this site visit. S+G performed monitoring of the perimeter LFG monitoring network during each event. Results of monitoring events are included in Attachment 1, and the data indicates several probes had exceedances of the LEL during the monitoring time period. Typically, these were the probes that historically have shown exceedances, and were previously connected to the LFG system. The recurrence of LFG in these areas is likely due to system shut down during repair, as upon completion of the system repairs recorded levels of methane dropped below the LEL. Attachment 2 provides a CH4 concentration graph over time for monitoring wells that have historically had methane present. Monitoring of the current well network will continue, and data will be reported to NCDEQand the County. 010 4 k Od-l". In general, the landfill gas extraction system continues to operate nominally. Operational outages during system repair likely caused the observed LEL exceedances. Methane concentrations observed in the monitoring network returned to levels below the LEL beginning in October, indicating this was a short term condition. S+Gwill continue to monitor the methane concentrations at the site monthly, and advise the County on repairs required to maintain an effective collection system. The next monitoring event is scheduled for January 2020. If you have any questions, or require additional information, please contact us at your earliest convenience at 919-828-0577or bye -mail (address below). DocuSign Envelope ID: 1E5C5E84-C12A-4FED-8723-F8CC375A1B6B Ms. Drummond January 3, 2020 Page 3 of 4 Sincerely, CAR Q� :oFssio• �j%,, o: QQ /Vq�L.'L DocuSigned by: j. SEAL 1//�2C20 E046707 ' z 8813721 B7E5F488... Spencer W. HolIomon, P.E. %,�' '•NGIIv •• �,����' Project Engineer, ext. 134 %,;;� W. IWHO``��.� rurnni spencer mithgardnerinc.com Attachments cc: Eric Foster —Avery County file CAR O �• E it SE4 0 SEAL a ,r DocuSignedby: 1369 (' , B9779EBA711F488... yO� FOf O Joan A. Smyth, P.G. A 020 Senior Hydrogeologist ext. 221 ioanCa:t,mithgardnerinc.com H:\Projects\Avery County (NC)\02 AC Compliance\LFG Monitor ing\MS\M2019\ 12 Dec 2019\J my 2019- December 2019 Avery MSW LFG Monitoring Report.docx DocuSign Envelope ID: 1E5C5E84-C12A-4FED-8723-F8CC375A1B6B Ms. Drummond January 3, 2020 Page 4 of 4 This page intentionally left blank. DocuSign Envelope ID: 1E5C5E84-C12A-4FED-8723-F8CC375A1B6B DocuSign Envelope ID: 1E5C5E84-C12A-4FED-8723-F8CC375A1B6B This page intentionally left blank. DocuSign Envelope ID: 1 E5C5E84-C12A-4FED-8723-F8CC375A1 B6B I '"r'.+4 i"++'+1► a � ✓ y, � l�, � �. � *L" y��.w �.'w.#a�,�~:. �, ,•� s'�; ; •*` � �' /` � z w Lj j ` �+44t •' N '. .1 •�' � co o �hL . ty� �. �. �.� r o ARN U ` ~ ok f" • fdo _ • f �1 y * Monitoring Probe •' r 40-60 . y L �, _ +r•'�;•. Lateral Connection COUNTYAVERY �._ to 1� AUTHORITY ■-(23. ACRESram � :� ��. - � y � .� cN ABANDONED IL Lu O, ,41ro z BUILPING � LL 1 �1 ' i a I • '. • O et /h ti� , a < w Existing Drain Line ' ! _ CLOSED AVERY COUNTYMSW .•+ ► ;,• . .o - ' _ ��i ___ o Q w CD O - LANDFILL, ice, .� 7. 7 • • ' '• • • . 0 #, 4" dW klPft �► �� "` zCD ' w f, • ��STING cousTI1 1 SYSTEM1�.or A LEGEND o r� + T� ' ' . 0 EXISTING LANDFILL GAS PROBE * - Location of Drain Line r..... ® s OFFSITE STRUCTURE TO BE Repair � • •^ ■ MONITORED r41, Y ' Q -' �. "` 1 1 • �1 � «. , � ,� •�;�` 'f—� �� p REFERENCES W *. 1. ADJACENT PROPERTIES ARE FROM AVERY COUNTY GIS MAPPING y y o � 1 ' ■ ! 1 • .. � �, DEPARTMENT. a ::_ y = 1• # '^� _• r 2. MONITORING WELL LOCATIONS FROM FIELD SURVEY DATED 1/14/08, BY J CM o w`- Existing Condensate �r ` ` • SURVEYING SOLUTIONS, P.C. — z � tAD + •}3. PROPERTY LINE FROM FIELD SURVEY DATED APRIL 9, 2010, BY o o Z A. sp I Tank y ' ,jr*pd APPALACHIAN PROFESSIONAL LAND SURVEYORS & CONSULTANTS. a = z �- r �:► • 4. LFG PROBES LOCATIONS FROM FIELD SURVEY DATED APRIL 9, 2010, BY z o a R �' �� '�"� !+� APPALACHIAN PROFESSIONAL LAND SURVEYORS & CONSULTANTS. } � . •■ �•; rr j 0. �, • : PROBE P-2, P-3, AND P-9 THROUGH P-13 LOCATIONS WERE NOT . j . • w + •r+ SURVEYED AND ARE APPROXIMATE. a y + o . ��• is •• 0 200' 400' a • • " r a Mo DocuSign Envelope ID: 1E5C5E84-C12A-4FED-8723-F8CC375A1B6B This Page Intentionally Left Blank DocuSign Envelope ID: 1E5C5E84-C12A-4FED-8723-F8CC375A1B6B DocuSign Envelope ID: 1E5C5E84-C12A-4FED-8723-F8CC375A1B6B This page intentionally left blank. DocuSign Envelope ID: 1 E5C5E84-C12A-4FED-8723-F8CC375A1 B6B SMITH GARDNER ' - to 1 •.o• : • 1/ V DqE August 2, 2019 BY BPR DMoeID DAe'Trre CF4 C E2 C2 BJa m ht.-bTp ALre Irit. Batic Resare A4. Setic Resare P4. Dff. RessLre* Frit.:Flcow]P4. RON 94em Ftesare nT d dcV yyyy % % % % deg F i n F 20 in12O i n F-20 3S:fm i n F 20 AVERY-W1 7/30/201913:07 36.0 14.5 9.4 40.1 88 -5.4 -5.4 -1.5 0.0 0.0 -4.3 AVERY-W2 7/30/201913:01 67.1 22.6 1.6 8.7 79 -5.2 -5.2 -1.5 0.0 0.0 -5.2 AVERY-W3 7/30/201912:56 71.0 26.7 0.2 2.1 78 -4.9 -4.9 -1.5 0.0 0.0 -4.9 AVE RY-W4 7/30/201912:48 69.9 24.2 0.8 5.1 89 -5.1 -5.1 -1.5 0.0 0.0 -5.2 AVERY-W5 7/30/201912:37 64.9 31.8 0.6 2.7 88 -5.1 -5.1 1.5 4.0 4.0 -5.1 AVERY-W6 7/30/201912:31 35.9 24.5 0.5 39.1 89 -5.0 -5.0 -1.5 0.0 0.0 -5.1 AVERY-W7 7/30/201912:41 41.5 24.8 0.4 33.3 88 -5.1 -5.1 1.4 0.0 0.0 -5.1 AVERY-W8 7/30/201912:24 35.2 27.0 0.8 37.0 88 -3.9 -3.9 -1.5 0.0 0.0 -4.0 AVERY-W9 7/30/201913:10 52.0 30.7 2.9 14.4 88 -5.4 -5.4 -1.5 0.0 0.0 -5.5 AVERY-W10 7/30/201912:53 25.4 12.6 12.9 49.1 88 -5.1 -5.1 -1.5 0.0 0.0 -5.1 Av-Flare 1 7/30/201914:52 4.0 1.8 19.4 1 74.8 NR -7.4 1 -7.4 1 NR NR NR NR *The differential pressure measurement should be positive. A negative differential pressure may indicate no gas flow. Negative differential pressure can be the result of dirt or water obstructing the pitot tube perforations. Overpul ling by adjacent extraction wells may also result in negative pressure being displayed. NR= not recorded DocuSign Envelope ID: 1 E5C5E84-C12A-4FED-8723-F8CC375A1 B6B SMITH GARDNER ' - to 1 •.o• : • DqE August 29, 2019 BY SCR DMoeID DAe'Trre CF4 C E2 C2 BIa W ht.-bTp ALre Irit. Batic Resare A4. Setic Resare P4. Dff. RessLre* Ir7t.:FRIv P4. RON 94em Ftesare nT d dcV yyyy % % % % deg F i n F 20 in12O i n F-20 3 S:fm i n F 20 AVERY-W1 8/13/201913:42 64.5 24.6 2.6 8.3 94 -5.4 -5.4 0.0 0.0 0.0 -5.4 AVERY- W2 8/ 13/ 2019 13: 51 3.7 0.4 19.8 76.1 84 -1.3 -1.3 0.0 0.0 0.0 -5.4 AVERY-W3 8/13/201914:06 65.6 23.8 1.8 8.8 81 -4.9 -4.9 0.0 0.0 0.0 -5.1 AVE RY-W4 8/13/201914:12 0.6 0.2 20.9 78.3 97 -4.0 -4.0 0.0 0.0 0.0 -5.7 AVERY-W5 8/13/201914:39 66.3 29.2 0.7 3.8 90 -5.9 -4.6 0.0 0.9 0.5 -5.9 AVERY- W6 8/ 13/ 2019 14: 35 2.1 0.6 20.1 77.2 89 -1.2 -1.2 0.0 0.0 0.0 -5.7 AVERY-W7 8/13/201914:44 43.7 23.6 0.7 32.0 92 -5.8 -2.7 0.1 0.3 0.3 -6.1 AVERY-W8 8/13/201914:28 35.1 24.5 1.0 39.4 1 92 -4.2 -4.2 0.0 0.0 0.0 -4.2 AVERY- W9 8/ 13/ 2019 13: 38 59.5 29.9 1.6 9.0 94 -5.4 -5.4 0.1 0.3 0.3 -5.7 AVERY-W10 8/13/201914:01 43.6 20.3 7.1 29.0 87 -5.4 -5.4 0.1 0.2 0.2 -5.7 Av-Flare 1 8/13/201915:15 1 14.7 5.3 16.8 63.2 83 1 3.7 1 3.7 1 3.4 1 NR NR 0.3 *The differential pressure measurement should be positive. A negative differential pressure may indicate no gas flow. Negative differential pressure can be the result of dirt or water obstructing the pitot tube perforations. Overpul ling by adjacent extraction wells may also result in negative pressure being displayed. NR= not recorded DocuSign Envelope ID: 1 E5C5E84-C12A-4FED-8723-F8CC375A1 B6B SMITH GARDNER D29E October 1, 2019 BY BPR DMoeID DAe'Trre CF4 C E2 C2 BJa W ht.-bTp ALre Irit. Batic Resare A4. Satic Resare P4. Dff. RessLre* Ir7t.:FRIv P4. RON 94em Ftesare nT d dcV yyyy % % % % deg F i n F 20 in120 i n F-20 3 S:fm i n F-20 AVERY-W1 9/30/201911:09 62.6 26.6 0.2 10.6 89 -30.0 -30.0 -2.7 0.0 0.0 -30.1 AVERY- W2 9/ 30/ 2019 12: 35 0.0 0.0 21.2 78.8 85 - 26.7 - 26.7 -1.5 0.0 0.0 - 26.7 AVERY-W3 9/30/201912:45 0.0 0.0 21.2 78.8 76 -29.0 -29.0 -2.9 0.0 0.0 -29.0 AVE RY-W4 9/30/201912:30 0.0 0.0 21.0 79.0 90 -6.0 -6.0 -0.8 0.0 0.0 -34.1 AVERY-W5 9/30/201912:19 61.5 26.6 0.4 11.5 89 -8.6 -8.6 3.4 6.0 6.0 -34.0 AVERY- W6 9/ 30/ 2019 12: 02 59.3 28.7 0.9 11.1 89 0.0 0.0 -1.5 0.0 0.0 - 37.3 AVERY-W7 9/30/201912:24 7.0 13.7 6.3 73.0 88 -17.8 -17.8 -6.2 0.0 0.0 -35.1 AVERY- W8 9/ 30/ 2019 11: 59 0.0 0.0 1 21.5 78.5 87 - 36.5 - 36.5 -1.3 0.0 0.0 - 36.0 AVERY- W9 9/ 30/ 2019 12: 39 8.6 17.4 5.1 68.9 88 - 32.2 - 32.2 - 0.7 0.0 0.0 - 32.3 AVERY-W10 9/30/201912:47 0.0 0.0 21.2 78.8 87 -30.0 -30.0 -2.9 0.0 0.0 -29.9 Av-Flare 9/30/201913:45 19.9 11.8 12.0 56.3 NR 2.3 NR NR NR NR NR *The differential pressure measurement should be positive. A negative differential pressure may indicate no gas flow. Negative differential pressure can be the result of dirt or water obstructing the pitot tube perforations. Overpul ling by adjacent extraction wells may also result in negative pressure being displayed. NR= not recorded DocuSign Envelope ID: 1 E5C5E84-C12A-4FED-8723-F8CC375A1 B6B SMITH GARDNER ' - Core 1 •.o• LVA : T F 11 • C., V 0• • • % • `+ 0 • • • tt Coma 1 DIE October 30, 2019 BY SCR DMoeID DAe'Trre CF4 C E2 C2 Nance ht.-bTp ALre Irit. Batic Resare A4. Setic Resare P4. Dff. RessLre* Ir7t.:FRIv P4. RON 94em Ftesare nTd dcV yyyy % % % % deg F inF20 inFPO i n F-20 Ik Sim i n F-20 AVERY-W1 10/24/201911:39 62.0 24.5 2.8 10.7 71 -31.2 -31.2 0.0 0.0 0.0 -32.3 AVERY-W2 10/24/201911:45 63.4 23.3 2.4 10.9 66 -25.8 -26.9 0.0 0.0 0.0 -31.9 AVERY-W3 10/24/201911:52 65.8 26.6 1.8 5.8 65 -29.4 -29.4 0.0 0.0 0.0 -31.8 AVE RY-W4 10/24/201911:56 25.4 8.0 13.2 53.4 78 -6.7 -6.6 0.0 0.0 0.0 -31.7 AVERY-W5 10/24/201911:59 54.7 28.6 1.5 15.2 68 -25.8 -27.7 1.7 2.8 4.1 -31.9 AVE RY- W6 10/ 24/ 2019 12: 03 34.1 16.0 9.8 40.1 76 -1.3 -1.3 0.0 0.0 0.0 - 31.6 AVERY-W7 10/24/201912:06 4.9 15.3 4.0 75.8 76 -5.4 -4.2 3.1 2.2 1.4 -31.8 AVE RY-W8 10/24/201912:13 17.0 21.1 3.4 58.5 67 -32.3 -20.7 0.0 0.0 0.0 -32.3 AVERY-W9 10/24/201911:42 12.7 16.4 4.5 66.4 64 -31.8 -31.8 0.1 0.3 0.2 -31.9 AVERY-W10 10/24/201911:49 13.1 5.8 16.9 64.2 68 -31.5 -31.8 0.1 0.3 0.3 -31.9 Av-Flare 10/24/201912:16 16.0 8.4 13.7 61.9 68 2.3 1.5 1.9 NR NR 0.0 *The differential pressure measurement should be positive. A negative differential pressure may indicate no gas flow. Negative differential pressure can be the result of dirt or water obstructing the pitot tube perforations. Overpul ling by adjacent extraction wells may also result in negative pressure being displayed. NR= not recorded DocuSign Envelope ID: 1 E5C5E84-C12A-4FED-8723-F8CC375A1 B6B SMITH GARDNER /i:1 - Core 1 e o• LVA : T . 11 D29E January 2, 2020 BY SwH DMoeID DAe'Trre CF4 C E2 C2 lbanee ht.-bTp ALre Irit. setic Resare A4. Setic Resare P4. Dff. RessLre* I:tRcow] '4. RON 94em Ftesare nT d dcV yyyy % % % % deg F inF2O inFPO i n F-20 Sim i n F-2O AVERY-W1 11/21/201910:08 57.4 23.6 4.3 14.7 48.2 -32.96 -32.58 0 0 0 -34.13 AVERY-W2 11/21/201910:23 59 21.6 3.8 15.6 57.2 -32.12 -32.12 0 0 0 -33.29 AVERY-W3 11/21/201910:17 58.7 23.8 3.3 14.2 54.5 -32.46 -32.46 0 0 0 -33.51 AVE RY-W4 11/21/201910:29 38.5 24.7 2.7 34.1 58.7 -29.44 -29.44 1.1 3.3 3.31 -32.05 AVERY-W5 11/21/201910:32 39.5 19.2 8.7 32.6 56.7 -0.85 -0.84 0 0 0 -31.96 AVE RY-W6 11/21/201910:36 10.6 19.4 1.4 68.6 57.2 -5.6 -5.56 1.158 0.87 0.87 -32.45 AVERY-W7 11/21/201910:40 46.3 28.9 4.8 20 55.2 -0.04 -0.04 0 0 0 1 -19.95 AVE RY-W8 11/21/201910:42 49.2 29 4 17.8 57.9 -0.04 -0.04 0.002 0 0.64 -9.4 AVERY-W9 11/21/201910:11 7.2 3.3 18.1 71.4 40.2 -33.5 -33.46 0.384 0.62 0.49 -33.6 AVERY-W10 11/21/201910:19 4.6 1.7 21.4 72.3 47.8 -33.42 -33.42 0.367 1 0.48 0.48 -31.6 Av-Flare NR NR NR NR NR NR NR NR NR NR NR NR *The differential pressure measurement should be positive. A negative differential pressure may indicate no gas flow. Negative differential pressure can be the result of dirt or water obstructing the pitot tube perforations. Overpul ling by adjacent extraction wells may also result in negative pressure being displayed. NR= not recorded DocuSign Envelope ID: 1 E5C5E84-C12A-4FED-8723-F8CC375A1 B6B SMITH GARDNER /i:1 i - Core 1 e o• LVA : T . 11 1--mqua .1 D29E January 2, 2020 BY SwH DMoeID DAe'Trre CF4 C E2 C2 lbanee ht.-bTp ALre Irit. setic Resare A4. Setic Resare P4. Dff. RessLre* Ir7t.:FRIv P4. RON 94em Ftesare nTd dcV yyyy % % % % deg F inF2O inFPO i n F-20 Ik Sim i n F-2O AVERY-W1 12/26/201917:45 0 0 21.2 78.8 53.3 -0.01 NR NR 2.05 NR NR AVERY-W2 12/26/201917:38 70 23.6 1.2 5.2 52.4 -6.02 -6.52 0 0 0 -7 AVERY-W3 12/26/201917:36 71.5 26.3 0.8 1.4 53 -6.36 -6.06 0 0 0 -0.04 AVE RY-W4 12/26/201914:56 77.4 22.6 0 0 73 4.89 4.87 0.058 14.57 18.75 -7.09 AVERY-W5 12/26/201914:36 58.5 28 0.7 12.8 71.3 -6.52 -6.82 0.142 1.18 1.21 -6.74 AVERY-W6 12/26/201914:32 67.3 30.4 0.7 1.6 82.6 0.3 0.3 0.017 9.01 9.05 -7.09 AVERY-W7 12/26/201914:42 40.5 21.3 1 37.2 72.9 -4.47 -4.46 0.034 0.14 0.15 -7.09 AVERY-W8 12/26/201917:24 63.1 33.6 0.4 2.9 55 0.19 0.2 0 0 0 -4.92 AVERY-W9 12/26/201917:41 4.9 1.5 19.6 74 52 -6.52 -6.48 0 0 0 -6.74 AVERY-W10 12/26/201917:30 8.7 3.8 18.3 1 69.2 51.5 -6.61 -6.57 1 0.095 0.25 0.25 -0.58 Av-Flare 12/26/201914:07 3.6 1 19.2 76.2 68.3 -16.27 -16.39 16.586 NR NR -0.04 *The differential pressure measurement should be positive. A negative differential pressure may indicate no gas flow. Negative differential pressure can be the result of dirt or water obstructing the pitot tube perforations. Overpul ling by adjacent extraction wells may also result in negative pressure being displayed. NR= not recorded DocuSign Envelope ID: 1 E5C5E84-C12A-4FED-8723-F8CC375A1 B6B /_I1F-AI A alrl woo DocuSign Envelope ID: 1E5C5E84-C12A-4FED-8723-F8CC375A1B6B This page intentionally left blank. DocuSign Envelope ID: lE5C5E84-C12A-4FED-8723-F8CC375A1B6B NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Avery County Closed MSW Landfill Permit Number: 06-01 Date of Sampling: 07/31 /2019 NC Landfill Rule (.0500 or .1600): .0500 Name and Position of Sample Collector: Britton P. Ransom, Project Manager Type and Serial Number of Gas Meter: GEM 2000, 07096 Calibration Date of Gas Meter: 4/2019 Date and Time of Field Calibration: 07/31/2019 - 1030 Type of Field Calibration Gas (15115 or 35/50): 15/15 Expiration Date of Field Calibration Gas Canister- 11/2021 Pump Rate of Gas Meter: 0.5 LPM Ambient Air Temperature: 85 F Barometric Pressure: 29.77 inHg General Weather Conditions: sunny Instructions: Under "Location or LFG Well" identify the monitoring wells or describe the location for other tests (e.g., inside buildings). A drawing showing the location of test must be attached. Report methane readings in both % LEL and % methane by volume. A reading in percent methane by volume can be converted to % LEL as follows: % methane by volume = % LEL✓20 Location or LFG Well ID Sample Tube Purge Tune Time Pumped (s) Initial %LEL Stabilized %LEL 1110'CH4 by Volume %02 %CO2 Notes P-1 >60s 1047 >60s 0 0 0 15.9 5.8 P-2 >60s 1110 >60s 0 0 0 21.5 0 P-3 NM NM NM NM NM NM NM NM P-4 >60s 1134 >60s 0 0 0 20.4 1.5 P-5 >60s 1142 >60s 0 0 0 19.6 11.6 P-6 >60s 1152 >60s 0 0 0 19.7 1.7 P-7 >60s 1159 >60s 4 4 0.2 18.9 2.3 P-8 >60s 1213 >60s 0 0 0 19.0 3.9 P-9 >60s 1057 >60s 0 0 0 19.8 1.3 P-10 >60s 1052 >60s 0 0 0 18.6 2.1 P-11 >60s 1102 >60s 0 0 0 16.1 3.5 P-12 >60s 1207 >60s 0 0 0 21.5 0 P-13 >60s 1403 >60s 0 0 0 10.7 9.1 Airport Structures 0 If your facility has more gas monitoring locations than there is room on this form, please attach additional sheets listing the same information as contained on this form. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. °1, 111, slgne0 oy b1l rens°m ritt ransom °""°°°n,a°same=°5°-5 ° SGCoI°mba. Project Manager mail=6ri0 1 GA 013,3D:ari-04 °aka: 201910.1013:30:08-00'00' SIGNATURE TITLE DocuSign Envelope ID: lE5C5E84-C12A-4FED-8723-F8CC375A1B6B NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Avery County Closed MSW Landfill Date of Sampling: 08/13/2019 Name and Position of Sample Collector: Permit Number: 06-01 NC Landfill Rule (.0500 or .1600): '0500 Spencer W. Hollomon Project Engineer Type and Serial Number of Gas Meter: Envision ENV100 1510204 Date and Time of Field Calibration: 08/13/2019 - 1333 Calibration Date of Gas Meter: 12/2018 Type of Field Calibration Gas (15115 or 35/50): 15/15 Expiration Date of Field Calibration Gas Canister: 10/2020 Pump Rate of Gas Meter: 0.5 LPM Ambient Air Temperature: 78 F Barometric Pressure: 30.00 inHg General Weather Conditions: Overcast Instructions: Under "Location or LFG Well" identify the monitoring wells or describe the location for other tests (e.g., inside buildings). A drawing showing the location of test must be attached. Report methane readings in both % LEL and % methane by volume. A reading in percent methane by volume can be converted to % LEL as follows: % methane by volume = % LEL/20 Locafion or LFG Well ID Sample Tube Purge Time Time Pumped (s) Initial °,ZEL Stabilized °,,ZEL Of CH4 by Vohlme %02 %CO2 Notes P-1 >60s 1609 >60s 2 2 0.1 11.5 8.7 P-2 >60s 1557 >60s 0 0 0 21.8 0.2 P-3 >60s 1702 >60s 1214 1214 60.7 1.6 27.9 P-4 >60s 1551 >60s 0 0 0 20.5 1.1 P-5 >60s 1505 >60s 0 0 0 19.9 1.0 P-6 >60s 1500 >60s 0 0 0 19.7 0.9 P-7 >60s 1451 >60s 4 4 0.2 19.1 1.2 P-8 >60s 1455 >60s 0 0 0 20.2 1.6 P-9 >60s 1544 >60s 0 0 0 20.4 0.7 P-10 >60s 1541 >60s 2 2 0.1 17.4 2.4 P-11 >60s 1547 >60s 0 0 0 16.3 2.5 P-12 >60s 1449 >60s 2 2 0.1 21.6 0.2 P-13 >60s 1603 >60s 0 0 0 10.2 7.9 Airport Structures >60s 1605 >60s 0 0 0 21.9 0.1 If your facility has more gas monitoring locations than there is room on this form, please attach additional sheets listing the same information as contained on this form. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. 4 2� Staff Geologist SIGNATURE TITLE DocuSign Envelope ID: lE5C5E84-C12A-4FED-8723-F8CC375A1B6B NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Avery County Closed MSW Landfill Permit Number: 06-01 Date of Sampling: 09/30/2019 NC Landfill Rule (.0500 or .1600): .0500 Name and Position of Sample Collector: Britton P. Ransom, Project Manager Type and Serial Number of Gas Meter: GEM 2000, 07096 Calibration Date of Gas Meter: 4/2019 Date and Time of Field Calibration: 09/30/2019 - 1045 Type of Field Calibration Gas (15115 or 35/50): 15/15 Expiration Date of Field Calibration Gas Canister- 11/2021 Pump Rate of Gas Meter: 0.5 LPM Ambient Air Temperature: 85 F Barometric Pressure: 27.44 inHg General Weather Conditions: partly cloudy Instructions: Under "Location or LFG Well" identify the monitoring wells or describe the location for other tests (e.g., inside buildings). A drawing showing the location of test must be attached. Report methane readings in both % LEL and % methane by volume. A reading in percent methane by volume can be converted to % LEL as follows: % methane by volume = % LEL✓20 Location or LFG Well ID Sample Tube Purge Tune Time Pumped (s) Initial oloLEL Stabilized %LEL 1110'CH4 by Volume %02 %CO2 Notes P-1 >60s 1109 >60s > 100% > 100% 62.6 0.2 26.6 P-2 >60s 1114 >60s > 100% > 100% 6.7 2.2 23.4 P-3 >60s 1118 >60s > 100% > 100% 71.4 3.5 25 P-4 >60s 1124 >60s 0 0 0 20.4 0.9 P-5 >60s 1129 >60s 0 0 0 20.8 0.4 P-6 >60s 1136 >60s 0 0 0 20.8 0.7 P-7 >60s 1141 >60s 0 0 0 21.4 0 P-8 >60s 1154 >60s 0 0 0 21.2 0.6 P-9 >60s 1057 >60s 0 0 0 20.2 1.1 P-10 >60s 1053 >60s 0 0 0 20.3 0.7 P-11 >60s 1102 >60s 0 0 0 16.0 3.4 P-12 >60s 1145 >60s 1 0 0 0 21.5 0 P-13 >60s 1338 >60s 0 0 0 11.6 7.2 Airport Structures 0 If your facility has more gas monitoring locations than there is room on this form, please attach additional sheets listing the same information as contained on this form. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. °1, 111, slgne0 oy b1l rens°m ritt ransom °""°°°n,a°same=°5°-5 ° SGCoI°mba. Project Manager mail=6ri0 1 GA 013,48:a4-04°m °aka1 201910.1013 40:24-04'00' SIGNATURE TITLE DocuSign Envelope ID: lE5C5E84-C12A-4FED-8723-F8CC375A1B6B NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Avery County Closed MSW Landfill Permit Number: 06-01 Date of Sampling: 10/24/2019 NC Landfill Rule (.0500 or .1600): .0500 Name and Position of Sample Collector: Spencer W. Hollomon Project Engineer Type and Serial Number of Gas Meter: Envision ENV100 1510204 Calibration Date of Gas Meter: 12/2018 Date and Time of Field Calibration: 10/24/2019 1128 Type of Field Calibration Gas (15115 or 35/50): 15/15 Expiration Date of Field Calibration Gas Canister: 10/2020 Pump Rate of Gas Meter: 0.5 LPM Ambient Air Temperature: 60 F Barometric Pressure: 30.30 inHg General Weather Conditions: Sunny Instructions: Under "Location or LFG Well" identify the monitoring wells or describe the location for other tests (e.g., inside buildings). A drawing showing the location of test must be attached. Report methane readings in both % LEL and % methane by volume. A reading in percent methane by volume can be converted to % LEL as follows: % methane by volume = % LEL/20 Locafion or LFG Well ID Sample Tube Purge Time Time Pumped (s) Initial °,ZEL Stabilized °,,ZEL Of4CH4 by Vohlme %02 %CO2 Notes P-1 >60s 1314 >60s 2 2 0.1 21.6 0 P-2 >60s 1252 >60s 2 2 0.1 21.2 0.5 P-3 >60s 1248 >60s 268 268 13.4 7.3 14.4 P-4 >60s 1240 >60s 0 0 0 19.9 1.8 P-5 >60s 1237 >60s 0 0 0 19.7 1.2 P-6 >60s 1232 >60s 0 0 0 20.4 0.5 P-7 >60s 1228 >60s 76 76 3.8 5.7 13.0 P-8 >60s 1223 >60s 2 2 0.1 19.3 2.8 P-9 >60s 1259 >60s 0 0 0 20.5 0.5 P-10 >60s 1256 >60s 0 0 0 20.7 0.3 P-11 >60s 1244 >60s 0 0 0 18.8 1.1 P-12 >60s 1226 >60s 2 2 0.1 20.9 1.8 P-13 >60s 1306 >60s 0 0 0 4.1 12.2 Airport Structures >60s 1308 >60s 0 0 0 21.5 0.0 If your facility has more gas monitoring locations than there is room on this form, please attach additional sheets listing the same information as contained on this form. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. 4�2__ Staff Geologist SIGNATURE TITLE DocuSign Envelope ID: lE5C5E84-C12A-4FED-8723-F8CC375A1B6B NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Avery County Closed MSW Landfill Date of Sampling: 11/21/19 Permit Number: 06-01 NC Landfill Rule (.0500 or .1600): .0500 Name and Position of Sample Collector: Spencer W. Hollomon Project Engineer Type and Serial Number of Gas Meter: Envision ENV100 1510204 Date and Time of Field Calibration: 11/21/2019 930 Calibration Date of Gas Meter: 12/2018 Type of Field Calibration Gas (15/15 or 35/50): 15/15 Expiration Date of Field Calibration Gas Canister: 10/2020 Pump Rate of Gas Meter: 0.5 LPM Ambient Air Temperature: 50 F Barometric Pressure: 28.01 inHg General Weather Conditions: Sunny Instructions: Under "Location or LFG Well" identify the monitoring wells or describe the location for other tests (e.g., inside buildings). A drawing showing the location of test must be attached Report methane readings in both % LEL and % methane by volume. A reading in percent methane by volume can be converted to % LEL as follows: % methane by volume = % LEL/20 Location or LFG Well ID Sample Tube Purge Time Time Pumped (s) Initial a/ZEL Stabilized %LEL %CH4 by Volume %02 %CO2 Motes P-1 >606 1002 >60s 26 26 1 3 22.2 0.2 P-2 >60s 1119 >60s 0 0 0 23 0 P-3 >605 1122 >60s 136 136 6.9 12.7 9.6 P-4 >60s 1105 >60s 0 0 0 22 1 P-5 >60s 1101 >60s 0 0 0 21.5 0.6 P-6 >60s 1056 >60s 2 2 0.1 22.2 0.3 P-7 >60s 1050 >60s 0 0 0 20.1 2.4 P-6 >60s 1046 >60s 4 4 0.2 21.9 1.1 P-9 >60s 1113 >60s 0 0 0 21.6 0.7 P-10 >60s 1115 >60s 0 0 0 21.9 0.5 P-11 >60s 1110 >60s 0 0 0 20.2 1 P-12 >60s 1050 >60s 4 4 0.2 22.1 3.1 P-13 >60s 1131 >60s 0 0 0 4.3 12.5 Airport Structures >60s 1134 >60s 0 0 0 21.3 0 If your facility has more gas monitoring locations than there is room on this form, please attach additional sheets listing the same information as contained on this form. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there ar gnifFcant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Project Engineer 1 ATURE TITLE DocuSign Envelope ID: lE5C5E84-C12A-4FED-8723-F8CC375A1B6B NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Avery County Closed MSW Landfill Permit Number: 06-01 Date of Sampling: 12/26/19-12/27/19 NC Landfill Rule (.0500 or .1600): .0500 Name and Position of Sample Collector: Mary Kennamer Project Engineer Type and Serial Number of Gas Meter: Envision ENV100 1510204 Date and Time of Field Calibration: 12/26/19 1345, 12/27/19 � Calibration Date of Gas Meter: 12/2018 Type of Field Calibration Gas (15115 or 35/50): 15/15 Expiration Date of Field Calibration Gas Canister: 10/2020 Pump Rate of Gas Meter: 0.5 LPM Ambient Air Temperature: 44 F Barometric Pressure: 28.01 inHg General Weather Conditions: Sunny Instructions: Under "Location or LFG Well" identify the monitoring wells or describe the location for other tests (e.g., inside buildings). A drawing showing the location of test must be attached. Report methane readings in both % LEL and % methane by volume. A reading in percent methane by volume can be converted to % LEL as follows: % methane by volume = % LEL/20 Location or LFG Weft ID Sample Tube Purge Time Time Pumped (s) Initial %LEL Stabilized OrZEL 9•aCH4 by Volume %02 %CO2 Notes P-1 >60s 1522 >60s 0 0 0 20.7 0 P-2 >60s 1527 0 0 0 0 20.7 0 P-3 >60s 1530 >60s 0 0 0 20.8 0 P4 >60s 1535 >60s 0 0 0 18.3 2.8 P-5 >60s 905 >60s 0 0 0 20.1 0.6 P-6 >60s 1426 >60s 0 0 0 20.4 0.1 P-7 >60s 1412 >60s 0 0 0 20.6 0 P-8 >60s 1401 >60s 0 0 0 19.9 0.6 P-9 >60s 938 >60s 0 0 0 20.2 0.5 P-10 >60s 929 >60s 0 0 0 19.8 0.4 P-11 >60s 947 >60s 0 0 0 19.9 0.3 P-12 >60s 920 >60s 0 0 0 21.2 0.7 P-13 >60s 1013 >60s 0 0 0 2.6 12.5 Airport Structures >60s 1015 >60s 0 0 0 21 0 If your facility has more gas monitoring locations than there is room on this form, please attach additional sheets listing the same information as contained on this form. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Mary Kennamer Project Engineer SIGNATURE TITLE DocuSign Envelope ID: 1 E5C5E84-C12A-4FED-8723-F8CC375A1 B6B DocuSign Envelope ID: 1E5C5E84-C12A-4FED-8723-F8CC375A1B6B This page intentionally left blank. DocuSign Envelope ID: 1E5C5E84-C12A-4FED-8723-F8CC375A1B6B SMITH GARDNER % CH4 by Volume Installation of V\19 and W10 70.0 A 0 90 i F. Mo WL • C;. A MIR • • • Installation of W9/P3 Installation of P7/W8 and Connection P1/W10 Connection (September 3, 2015) I I I I I I I I 1 I 1 I I I I I I I I I 1 I I By: SWH Date: 1/2/2020 0.0 rl N N i N N N N N N N M M i M' M M M M M M i L!1 L(1 L!1 I 111 L!1 LA L!1 LA I U1 lD lD lD lD lD lD lD kD I lD I, n n 4 n n n n n r, w w w w w w w w > Wrmrmri Mrai T Mi--I Mrl Mri Mrl M z> M O O. . O O. . O. . O. . O � atiOa�z 6 uoac-0 c up c-�agc uoa,,z b c6� a) O aa) M a) O a,o , a, Z O W MaJ n Ow M a) O a) v M a, aagc ��oOaz c�c uoa a agooa aV,oa QV,00� a allo, a agoo, C O a, v �aC O av a C O a1 ry ano0i a,QV,o0—i a ,alloi 0 DocuSign Envelope ID: 1E5C5E84-C12A-4FED-8723-F8CC375A1B6B This Page Intentionally Left Blank Certificate Of Completion Envelope Id: lE5C5E84Cl2A4FED8723F8CC375AlB6B Subject: Please DocuSign: July 2019-December 2019 Avery MSW LFG Monitoring Report.pdf Source Envelope: Document Pages: 28 Signatures: 2 Certificate Pages: 2 Initials: 0 AutoNav: Enabled Envelopeld Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) Record Tracking Status: Original 1/3/2020 11:54:20 AM Signer Events Spencer W. Hollomon spencer@smithgardnerinc.com Smith Gardner, Inc. Security Level: Email, Account Authentication (None) Electronic Record and Signature Disclosure: Not Offered via DocuSign Joan Smyth joan@smithgardnerinc.com Vice President Smith Gardner, Inc. Security Level: Email, Account Authentication (None) Electronic Record and Signature Disclosure: Not Offered via DocuSign In Person Signer Events Editor Delivery Events Agent Delivery Events Intermediary Delivery Events Certified Delivery Events Carbon Copy Events Witness Events Notary Events Envelope Summary Events Envelope Sent Certified Delivered Signing Complete Holder: Spencer W. Hollomon spencer@smithgardnerinc.com Signature EDII"Sil"Id by: 8B13721B7E5F488... Signature Adoption: Pre -selected Style Using IP Address: 24.106.183.110 byyy:,yEDI-Sig"_SId EBA711F S Signature Adoption: Pre -selected Style Using IP Address: 24.106.183.110 Signature Status Status Status Status Status Signature Signature Status Hashed/Encrypted Security Checked Security Checked Docu5�". 6 S E C U R E D Status: Completed Envelope Originator: Spencer W. Hollomon 14 N. Boylan Ave Raleigh, NC 27603 spencer@smithgardnerinc.com IP Address: 24.106.183.110 Location: DocuSign Timestamp Sent: 1/3/2020 11:58:26 AM Viewed: 1/3/2020 11:58:33 AM Signed: 1/3/2020 11:58:44 AM Sent: 1/3/2020 11:58:45 AM Viewed: 1/3/2020 12:10:18 PM Signed: 1/3/2020 12:10:31 PM Timestamp Timestamp Timestamp Timestamp Timestamp Timestamp Timestamp Timestamp Timestamps 1/3/2020 11:58:45 AM 1/3/2020 12:10:18 PM 1/3/2020 12:10:31 PM Envelope Summary Events Completed Status Security Checked Timestamps 1/3/2020 12:10:31 PM Payment Events Status Timestamps