Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
MO-9528_40963_CA_UST-61_20191120_24-Hour Release and UST Leak Reporting Form & Receptor Discussion
UST-61 I 24-Hour Release and UST Leak Reporting Form. For Releases This form should be completed and submitted to the UST Section's regional office following a known or suspected release from an underground storage tank (UST) system. This form is required to be submitted within 24 hours of discovery of a known or in NC suspected release (DWM USE ONLY) Suspected Contamination? (Y/N) Y Facility ID Number N/A Incident # Risk (H,I,L,U) Confirmed GW Contamination? (Y/N) N Date Leak Discovered 11/20/19 Received On Received By Confirmed Soil Contamination ?(Y/N) Y Comm/Non-Commercial? Non-Qgmm. Reported by (circle one): Phone, Fax or Report Samples Taken?(Y/N) Y Reg/Non-regulated? Non -Reg. Region Free Product? (Y/N) N If Yes, State Greatest Thickness N/A INCIDENT DESCRIPTION Incident Name: Wagner Residence Address: 1132 Providence Road County: Mecklenburg City/Town: Charlotte Zip Code: 28207 Regional Office (circle one): Asheville, Mooresville Fayetteville, Raleigh, Washington, Wilmington, Winston-Salem Latitude (decimal degrees): N 35.19222629' Longitude (decimal degrees) : W 80.82473991 ° Obtained by: M GPS Briefly describe suspected or confirmed release: (including but not limited to: nature of release, date of release, amount of release, amount of free product present and recovery efforts, initial responses conducted, impacts to receptors) ❑ Topographic map ❑ GIS Address matching ❑ Other ❑ Unknown Describe location: -Soil contamination discovered by observing surface staining from heating oil floating out of tank following heavy precipitation during storm -TPH results attached -Tank was removed on November 11, 2019 -Soil contamination confirmed beneath UST to be addressed with NRP -Soil contamination at surface removed during Initial Abatement Activities HOW RELEASE WAS DISCOVERED (Release code) (Check one) ❑ Release Detection Equipment or Methods ❑ Visual/Odor ❑ Groundwater Contamination 81 During UST Closure/Removal ❑ Water in Tank ❑ Surface Water Contamination ❑ Property Transfer ❑ Water Supply Well Contamination ❑ Other (specify) SOURCE OF CONTAMINATION Source of Release Cause of Release Type of Release Product Type Released (Check one to indicate primary (Check one to indicate primary (Check one) (Check one to indicate primary product type source) cause) released) M Tank M Spill M Petroleum ❑ Gasoline/ Diesel/ ❑ Diesel/Veg. Oil Kerosene Blend ❑ Piping ❑ Overfill ❑ Non -Petroleum M Heating Oil ❑ Vegetable Oil 100% ❑ Dispenser ❑ Corrosion ❑ Both ❑ Other Petroleum ❑ E10 — E20 ❑ Submersible Turbine Pump ❑ Physical or Mechanical Products ❑ E21 E84 — ❑ Delivery Problem Damage Location ❑ Metals ❑ ❑ E85 E99 ❑ Install Problem (Check one) Other Inorganics — ❑ Other ❑ Other Facility ❑ Other Organics ❑Ethanol 100% ❑ Unknown O Eo1 — Eoe t� Unknown ®Resiaence Definitions presented on reverse Definitions presented on reverse ❑ Other Ownership 1. Municipal 2. Military 3. UnknownOPrivate 5. Federal 6. County 7. State Operation Type 1. Public Service 2. AgriculturalOResidential 4. Education/Relig. 5. Industrial 6. Commercial 7. Mining U01 runn o 1 kuuuo) Page 1 of 2 IMPACT ON DRINKING WATER SUPPLIES Water Supply Wells Affected? 1. Yes ONo 3. Unknown Number of Water Supply Wells Affected Water Supply Wells Contaminated: (Include Users Names, Addresses and Phone Numbers. Attach additional sheet if necessary) 1. 2. 3. UST SYSTEM OWNER UST Owner/Company Sean Wagner Point of Contact Address 1132 Providence Road City State Zip Code Telephone Number Charlotte NC 28207 (405) 664-1869 UST SYSTEM OPERATOR UST Operator/Company Address Unknown City State Zip Code Telephone Number LANDOWNER AT LOCATION OF UST INCIDENT Landowner Same as UST System Owner Address City State Zip Code Telephone Number Draw Sketch of Area (showing two major road intersections) or Attach Map See Attached Map Person Reporting Incident Ben Robinson Company Paragon Environmental Consultants, InC. Telephone Number(336) 669-6037 Title Geologist Address P.O. Box 157, Thomasville, NC 27361 Date 11-20-2019 UST Form 61 (02/08) Page 2 of 2 Definitions of Sources Tank: means the tank that stores the product and is part of the underground storage tank system Piping: means the piping and connectors running from the tank or submersible turbine pump to the dispenser or other end -use equipment ( Vent, vapor recovery, or fill lines are excluded.) Dispenser: includes the dispenser and the equipment used to connect the dispenser to the piping (e.g., a release from a suction pump or from components located above the shear valve) Submersible Turbine Pump (STP) Area includes the submersible turbine pump head (typically located in the tank sump), the line leak detector, and the piping that connects the submersible turbine pump to the tank Delivery Problem: identifies releases that occurred during product delivery to the tank. (Typical causes associated with this source are spills and overfills.) Other: serves as the option to use when the release source is known but does not fit into one of the preceding categories (e.g., for releases from vent lines, vapor recovery lines, and fill lines) Unknown: identifies releases for which the source has not been determined Definitions of Causes Spill: use this cause when a spill occurs (e.g., when the delivery hose is disconnected from the tank fill pipe or when the nozzle is removed from the dispenser) Overfill: use when an overfill occurs (e.g., overfills may occur from the fill pipe at the tank or when the nozzle fails to shut offat the dispenser) Physical or Mechanical Damage: use for all types of physical or mechanical damage, except corrosion (e.g., puncture of tank or piping, loose fittings, broken components, and components that have changed dimension) Corrosion: use when a metal tank, piping, or other component has a release due to corrosion (e.g., for steel, corrosion takes the form of rust) Installation Problem: use when the problem is determined to have occurred specifically because the UST system was not installed properly Other: use this option when the cause is known but does not fit into one of the preceding categories (e.g., putting regulated substances into monitoring wells) Unknown: use when the cause has not been determined L.RISM Full -Service Analytical Environmental Solutions LABORATORIES, INC. Paragon Environmental Consultants, Inc. Brandon Moore PO Box 157 Thomasville, NC 27361 NC Certification No. 402 NC Drinking Water Cert No. 37735 SC Certification No. 99012 Project: Wagner Residence Lab Submittal Date: 11/13/2019 Prism Work Order: 9110220 Case Narrative 11 /20/19 15:28 This data package contains the analytical results for the project identified above and includes a Case Narrative, Sample Results and Chain of Custody. Unless otherwise noted, all samples were received in acceptable condition and processed according to the referenced methods. Data qualifiers are flagged individually on each sample. A key reference for the data qualifiers appears at the end of this case narrative. Please call if you have any questions relating to this analytical report. Respectfully, PRISM LABORATORIES, INC. a,j Angela D. Overcash VP Laboratory Services Data Qualifiers Key Reference: Reviewed By Angela D. Overcash VP Laboratory Services DO Surrogates diluted out. RLM Sample container suspected to have low methanol content. Results possibly biased high. SR Surrogate recovery outside the QC limits. BRL Below Reporting Limit MDL Method Detection Limit RPD Relative Percent Difference * Results reported to the reporting limit. All other results are reported to the MDL with values between MDL and reporting limit indicated with a J. This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240643 - Charlotte, NC 28224-0643 Phone: 704/529-6364 - Toll Free Number: 1-800/629-6364 - Fax: 704/626-0409 Page 1 of 17 Summary of Detections PRISM Full-Servico Analytical & Environmental Solutions 11/20/2019 .&A' kL�dUNATORIE3, ING Prism Work Order: 9110220 Prism ID Client ID Parameter Method Result Units 9110220-01 TI-6.5 Diesel Range Organics '8015C 8700 mg/kg dry 9110220-01 TI-6.5 Gasoline Range Organics '8015C 63 mg/kg dry 9110220-02 X-1 Diesel Range Organics '8015C 11000 mg/kg dry 9110220-02 X-1 Gasoline Range Organics "8015C 51 mg/kg dry This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240643 - Charlotte, NC 28224-0643 Phone: 704/629-6364 - Toll Free Number: 1-800/629-6364 - Fax: 704/526-0409 Page 3 of 17 PRISM Full -Service Analytical & Environmental Solutions tJ�U�PATORI[S ma Laboratory Report 11 /20/2019 Paragon Environmental Consultants, Inc. Attn: Brandon Moore PO Box 157 Thomasville, NC 27361 Project: Wagner Residence Sample Matrix: Solid Client Sample ID: TI-6.5 Prism Sample ID: 9110220-01 Prism Work Order: 9110220 Time Collected: 11/11/19 10:30 Time Submitted: 11/13/19 08:00 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor DatefTime ID Diesel Range Organics by GC/FID Diesel Range Organics 8700 mg/kg dry 630 180 50 A8016C 11120/19 10:18 ZRC P91<0322 Surrogate Recovery Control Limits o-Terphenyl 0 % 31-123 DO Gasoline Range Organics by GC/FID Gasoline Range Organics 63 mg/kg dry 7.8 2.1 50 A801SC 11/19/19 10:11 TBL P9K0286 Surrogate a,a,a-Trill uorotoluene Recovery Control Limits 85 % 50-137 General Chemistry Parameters % Solids 65.6 % by 0.100 0.100 1 'SM2640 G 11/18/19 7:66 EDV P9K0291 Weight This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240643 - Charlotte, NC 28224-0543 Phone: 704/629-6364 - Toll Free Number: 1-800/629-6364 - Fax: 704/626-0409 Page 4 of 17 F S M I Full -Service Analytical & Environmental Solutions LAeeRRTINiI[S ING Laboratory Report 11 /20/2019 Paragon Environmental Consultants, Inc. Project: Wagner Residence Client Sample ID: X-1 Attn: Brandon Moore Prism Sample ID: 9110220-02 PO Box 157 Prism Work Order: 9110220 Thomasville, NC 27361 Sample Matrix: Solid Time Collected: 11 /11 /19 10:45 Time Submitted: 11/13/19 08:00 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor Date[Time ID Diesel Range Organics by GC/FID Diesel Range Organics 11000 mg/kg dry 690 200 60 '8016C 11/20/19 10:66 ZRC 1291(0322 Surrogate Recovery Control Limits o-Terphenyl 0 % 31-123 DO Gasoline Range Organics by GC/FID Gasoline Range Organics 61 mg/kg dry 9.4 2.6 60 '8015C 11/19/19 9:43 TBL PSK0286 Surrogate Recovery Control Limits a,a,a-Tdfluorotoluene 124 % 50-137 General Chemistry Parameters % Solids 59.8 % by 0.100 0.100 1 'SM2640 G 11/18/19 7:66 EDV P91(0291 Weight This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240643 - Charlotte, NC 28224-0643 Phone: 704/629-6364 - Toll Free Number: 1-800/629-6364 - Fax: 704/626-0409 Page,5 of 17 p p z u m �' z 000 $ c D L o c m n c 3 �L C -0 m m nix N D a ma n p pn 0 n ry - wr m N......___._,...._. D W m m D a 0Ozs2. zS DI Q om I I C) C D1 0 I 4. p v 3 "' ti 0 m N m m00 a vN v0� n CD mo zm nm m 1 �p pro v> �' n ') o � :3 � I U) D l W j m �� c= II ZC �ca 'o c� D p O' v m N ram- a � c I I m' C7A N y m =a m a v �. O C1 -4 m t- OCD ap p 0 o l w O O D I I _ o ❑m w CD n n CD W r 0 D O n yL O1; n a c=i Z Z o , y 'TI U r+ mecca c' z S C! r IID li C m L N vo w o U) C v 0 N 0 G� z r N N m m fl N r D CO h n z ' p rNn -0 .-� + z { z �. m d xK > O 1m j1D -� O r 0 3 0 -a to .. (..> G> (J C > W d C�' Ca © ���m c Ca C' O C>' V t < mm tv Ce -_ c -1 > vm0-1 m X r 0 c N 1 3 0 m m �3 � � �, i m y Z-�" o a O m D m m a p m �. O r m A < .d� G OA cC N N n. zb o55 o ma, o m ;a o o < m m p N x o°�v m OZ m A HO y N n 0 — m Z. n n a❑ W -_I < m A O m 6 O i VD Q mD�C n z z m �. ❑ < a o� D� N X X .._ /� o a� O �5 ! " I C, I <�:> I - I C-, I (:l, I osro z �m3 M m n 0 0 m oEj D 0-0 sF a n °' 3 7w T rD 61 � rA N z O p! �� 1�1✓! al z Ai A O N O D O C/ O x v rn0 A O. � n m? x 7 C UA b CD n m 03 oN to V 2) D v N N u `r � rt, n N 3 's nA 0 a o. < d o m m m vOi fD A i � -4 A ° z 0 �. at�v i r� Z I—' Ky-moo 0 coo �7 m -0. 2 @ ;' N0 Ci tD N a G 7 � A }� fA C, m Y/ f O9 CA to --4 'C1 m r m 0 , s0 i m D r I 0 _ 62 (q m m 0 d0. ` Qr m 0 m m m a p n n p c 3 c m QN�`-xlZ-i (/) z m Z -3 -z-I D = umi 5 CAS P D ri r z m m -I 0< . L n 0� a)I : z mazoAmo� n ���i�noCm� ml N 0 EM I 9 9z K S a �' `' a = z m O C7 ti v m m D v0 ' M to in lO m m a n -n r z I� I ((( {{ o n Z z C l ti Page 17 of 17 W m O O C7 m m a^ � All h y C i t,. ACI Altvt yk v.o M ^s qb w Beverly, Trudy From: Ben Robinson <brobinson8915@gmail.com> Sent: Tuesday, December 3, 2019 8:34 AM To: Beverly, Trudy Subject: Re: [External] Wagner Residence UST-61 External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to report.spam@nc.gov Good morning Trudy, There are no supply wells located within 150' of the release. I apologize for omitting that information. Hope you had a good holiday! Thanks! Ben Robinson, L.G. Paragon Environmental Consultants, Inc. On Mon, Dec 2, 2019 at 1:37 PM Beverly, Trudy <trudy.beverlykncdenr.gov> wrote: Ben, Neither the UST-61 nor the Initial Abatement Report contains receptor information. Are there any water supply wells located within 150' of the release. Thanks, Trudy From: Beverly, Trudy Sent: Monday, December 2, 2019 8:29 AM To: Ben Robinson <brobinson8915@gmail.com> Subject: RE: [External] Wagner Residence UST-61 Received Trudy 1 cc�DEQ 14/1 rlmeneoi €mavnmentJ1 &Wft Trudy Beverly, L.G. Hydrogeologist, Division of Waste Management North Carolina Department of Environmental Quality UST Section, Mooresville Regional Office 704.235.2182 (Office) Trudy. Beverly@ncdenr.gov Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Office Mailing Address: 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Branch's Underground Storage Tanks Website Address: https://deg.nc.gov/about/divisions/waste-management/ust Branch's Above Ground Storage Tanks Website Address: https://deq.nc.gov/about/divisions/waste-management/ust/ast-program INTERACTIVE MAPS WITH DWM SITES AND PERMITTED FACILITIES: https://deg.nc.gov/about/divisions/waste-management/waste-management-rules-data/waste-management-gis-maps File Review Procedures: https://deg.nc.gov/about/divisions/waste-management/ust/file-review-procedures#mooresviIIe-regional-office ONLINE ACCESS TO UST SECTION DOCUMENTS (Laserfiche): https://deg.nc.gov/about/divisions/waste-management/laserfiche Document Submittal & UST File Names for Laserfiche Policies: https://files.nc.pov/ncdeq/Waste%20Management/DW M/UST/Corrective%2OAction/Electronic%2ODocument%2OSubmittal%20Memo%20Update.pdf hiips:Hfiles.nc. gov/ncdegiW aste%2OManagement/D W M/UST/Corrective%2OAction/UST%20file%20names%20for%2OLaserfiche. docx From: Ben Robinson[mailto:brobinson8915@gmail.com] Sent: Wednesday, November 20, 2019 4:37 PM To: Beverly, Trudy <trudy.beverly@ncdenr.gov> Subject: [External] Wagner Residence UST-61 CAUTION: -1 chments unless ou v Hello, !rify. Send all suspicious email as an please find attached to this e-mail the UST-61 for the Wagner Residence, located at 1132 Providence Road, Charlotte, NC 28207. Thank you very much! Ben Robinson, L.G. Paragon Environmental Consultants, Inc.