Loading...
HomeMy WebLinkAbout6301_Moore_MSWLF_CDLF_LFG_FID1377458_20191125ENR USE ONLY ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #: 'NIC DENR I I Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Golder Associates NC, Inc. (on behalf of Moore County) Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Benjamin S. Draper, PG Phone: 336-852-4903 E-mail: bdraper@golder.com NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) Moore County Landfill 456 Turning Leaf Way 63-01 .0500 November 20, 2019 Aberdeen, NC 28315 Environmental Status: (Check all that apply) Initial/Background Monitoring FJ Detection Monitoring Assessment Monitoring QX Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells ❑X Groundwater monitoring data from private water supply wells Leachate monitoring data ❑ Surface water monitoring data Methane gas monitoring data Corrective action data (specify) Other(specify) Notification attached? B No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. �X Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Benjamin S. Draper, PG Senior Project Geologist 336-852-4903 Facility Repressive Name (Print) _<�7 Title /I-zs-iy re / / / Date Golder Associates NC, Inc., 5B Oak Branch Drive, Greensboro, NC 27407 Facility Representative Address PE C-2862; PG C-399 (Area Code) Telephone Number ���i+�nrne�regr. Affix NC Licenso& feGiA ist Seal 0/ ?. f Y e ` 313 Q44/� NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6)- Facility Name: Moore County Landfill Permit Number: 63-01 Sampling Date: 1 1 /20/ 1 9 Landfill Rule (.0500 or.1600): '0500 Sample Collector Name & Position: Erik Vasko Gas Meter Type & Serial Number: GEM 5000 Field Calibration Date & Time: 1 1 /20/1 9 09:00 Field Calibration Gas Type (15'15 or35/50) Gas Meter Pump Rate: 300 cc/min Gas Meter Calibration Date: 1 1 /20/1 9 35/50 Field Calibration Gas Canister Expiration Date: 2/2 1 /21 0 Ambient Air Temperature: Barometric Pressure (in. or min Hg): 29' 9 Weather Conditions: Fair, winds N at 14mph. Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to %LEL as follows: % methane (by volume)/20 = %LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized °,o LEL % CH4 (volume) % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES GP-9 60 14:03 60 0 0 0.0 21.4 0.5 0 1 Inch Well GP-10 60 13:56 60 18 18 0.9 12.0 4.9 0 1 Inch Well GP-11 60 13:48 60 0 0 0.0 19.5 2.6 0 1 Inch Well GP-12 60 12:47 60 0 0 0.0 20.6 0.2 0 1 Inch Well GP-13 60 13:33 60 0 0 0.0 21.2 0.5 0 1 Inch Well GP-13R 60 13:30 60 0 0 0.0 20.9 1.1 0 1 Inch Well GP-14 60 13:36 60 0 0 0.0 21.0 0.5 0 1 Inch Well GP-14R 60 13:26 60 0 0 0.0 20.2 1.3 0 1 Inch Well GP-15 60 13:07 60 0 0 0.0 11.2 4.6 0 1 Inch Well GP-15R 60 13:19 60 0 0 0.0 20.2 1.1 0 1 Inch Well GP-16 60 13:03 60 0 0 0.0 12.3 8.8 0 1 Inch Well GP-17 60 12:59 1 60 0 0 0.0 1 4.2 10.3 0 1 Inch Well NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true an correct. I am ware that there are significant penalties for making any false statement, representation, or cert' i'ona u th ssibility of a fine and imprisonment. P(A Geologist IGNATURE Ca IIe- C) TITLE Revised -March 6, 2017 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Moore County Landfill Number: 63-01 Sampling Date: 1 1 /20/19 NC Landfill Rule (.0500 or.1600): Sample Collector Name & Position: Erik Vasko .0500 Gas Meter Type & Serial Number: GEM 5000 Gas Meter Calibration Date: Field Calibration Date & Time: 1 1 /20/19 09:00 11 /20/19 Field Calibration Gas Type (15 15 or 35150): 35/50 Field Calibration Gas Canister Expiration Date: 2/21 /21 Gas Meter Pump Rate: 300 cc/min 61 OF 29,9 Fair, winds N at 14mph. Ambient Air Temperature: Barometric Pressure (in. or mm Hg): Weather Conditions: Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert °a CH4 (by volume) to ?o LEL as follows: % methane (by volume)/20 = %LEL. *Hydrogen Sulfide (112S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized °o LEL %CH4 (volume) ° /0 02 (volume) o /o CO2 (volume) ° /p H2S * (volume) NOTES MW-6 60 14:08 60 22 22 1.1 17.3 3.9 0 2 Inch Groundwater Well MW-15 60 14:15 60 372 372 18.6 5.9 17.7 0 21nchGmundwaterWellco-tedt.-than. probe GV-33 (Eastern Vent) 60 14:12 60 0 0 4.9 2.5 15.4 0 Gas Vent GV-34 (Western Vent) 60 14:11 60 0 0 0.2 21.1 0.6 0 Gas Vent SCALEHOUSE 60 12:34 90 0 0 0.0 21.1 0.1 0 Building Maintenance Shop 60 12:45 90 0 0 0.0 21.0 0.1 0 Building Transfer Station 60 12:39 90 0 0 0.0 0.0 21.1 0 Bundling Blake Resldenae(C2wl Space) 60 12:10 90 0 0 0.0 0.0 20.5 0 Building The Landtec GEM 5000 has a CH4 accuracy range of +/- 0.3 % NOTE: If needed, attach additional data farms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or c ca ' in dit gke possibility of a fine and imprisonment. RINC Geologist SIGNATURE F Z I Y:VTITLE Revised - March 6, 2017 LEGEND 3 a cri 0 0 w 0 rn M CD O 6 E m Z SW-2 /VECEPATION I IE VEGUATION 07 / 1 GROUND OBSCURED SEE ACCURACY NOTE GROUND OBSCURED SEE ACCURACY NOTE VLILI9 1 MOORE COUNTY CONSULTANT YYYY-M M-DD PG C-399 PREPARED r)nl n OA OCZ �j c— STREAM, POND, AND WETLAND LIMITS EXISTING 10 FT GROUND SURFACE CONTOUR EXISTING 2 FT GROUND SURFACE CONTOUR PROPERTY LINE APPROXIMATE LIMITS OF WASTE _ = EXISTING ROAD POTENTIOMETRIC GROUNDWATER CONTOURS (5 FT. INTERVAL) GROUNDWATER FLOW SEGMENTS MW-1 MONITORING WELL AND IDENTIFICATION '382.42 GP-10 METHANE PROBE AND IDENTIFICATION ❑ SW-1 SURFACE WATER MONITORING POINT AND IDENTIFICATION LANDFILL GAS TRENCH VENTS AND IDENTIFICATION PASSIVE LANDFILL GAS VENTS 0 PW-1 PRIVATE WELL LOCATION AND IDENTIFICATION 4 WETLAND AREA SB-2 SOIL SAMPLE LOCATIONS PZ-2 PIEZOMETERS NOTES 1. TOPOGRAPHIC CONTOUR INTERVAL = 2 FEET 2. GROUNDWATER SURFACE CONTOUR INTERVAL = 5 FEET 3. GROUNDWATER ELEVATIONS MEASURED ON APRIL 2, 2019. 4. GROUNDWATER CONTOURS BASED ON LINEAR INTERPOLATION BETWEEN AND EXTRAPOLATION FROM KNOWN DATA, TOPOGRAPHIC CONTOURS, AND KNOWN FIELD CONDITIONS. THEREFORE, GROUNDWATER CONTOURS MAY NOT REFLECT ACTUAL CONDITIONS. 5. GROUNDWATER CONTOUR LINES SHOW THE WATER TABLE SHAPE AND ELEVATION. THESE CONTOURS ARE INFERRED LINES FOLLOWING THE GROUNDWATER SURFACE AT A CONSTANT ELEVATION ABOVE SEA LEVEL. THE GROUNDWATER FLOW DIRECTION IS GENERALLY PERPENDICULAR TO THE GROUNDWATER SURFACE CONTOURS, SIMILAR TO THE RELATIONSHIP BETWEEN SURFACE WATER FLOW AND TOPOGRAPHIC CONTOURS. 6. PROPERTY BOUNDARY SURVEY BY JAMES L. WRIGHT DATED NOVEMBER 1984. ITS LOCATION IS RELATIVE TO TOPOGRAPHY APPROXIMATE BY HDR ENGINEERING, INC. 7. EXISTING TOPOGRAPHY WITHIN ACTIVE AND PROPOSED LANDFILL PROVIDED BY MATTHEWS LAND SURVEYING & MAPPING, PLLC DATED APRIL 17, 2015 AND JUNE 2018. 8. MONITORING WELLS MW-1 THROUGH MW-5 SURVEYED JUNE 1987 BY S&ME, INC. MONITORING WELLS MW-6 THROUGH MW-16 SURVEYED APRIL 1995, SEPTEMBER 1996, AND APRIL 2003 BY HDR ENGINEERING INC./ ED BUCKNER RLS APRIL 17, 2015. 9. THE LOCATIONS OF LANDFILL GAS TRENCH VENTS ARE APPROXIMATE. 10. GROUNDWATER WELLS MW-11 D, MW-13D, AND MW-16D ARE NOT SCREENED IN THE SHALLOW AQUIFER AND ELEVATION DATA WERE NOT USED IN THE CONSTRUCTION OF GROUNDWATER CONTOURS. 11. A STREAM DETERMINATION WAS CONDUCTED ON APRIL 17, 2013 BY A GOLDER ASSOCIATES NC, INC. REPRESENTATIVE. THE STREAM DETERMINATION WAS CONDUCTED USING NCDWQIS "METHODOLOGY FOR IDENTIFICATION OF INTERMITTENT AND PERENNIAL STREAMS AND THEIR ORIGINGS, VERSION 4.11°. 0 200 400 SCALE FEET PROJECT MOORE COUNTY LANDFILL PERMIT NO. 63-01 ABERDEEN, NORTH CAROLINA TITLE GROUNDWATER SURFACE CONTOUR MAP APRIL 2, 2019 11 IE SITE LOCATION MAP NOT TO SCALE GO L D E R DESIGN REVIEW GOLDER ASSOCIATES NC, INC. APPROVED RPK PROJECT No. PHASE DRAWING 0739615018 200 0 0 INSTRUMEP t T CALIBI ATION REPORT Pine Environmental Services LLC Pine Environmental Services, Inc. Instrument ID 41616 Description Gem 5000 Calibrated 11/15/2019 1:40:28PM Manufacturer CES Landtec Model Number GEM5000 Serial Number/ Lot G505251 Number Location North Carolina Department Calibration Specifications Group # 1 Group Name Methane Stated Accy Pet of Reading Nom In Val / In Val In Type Out Val Out Tvp�e 50.00 / 50.00 %Volume 50.00 %Volume Group # 2 Group Name Carbon Dioxide Stated Accy Pet of Reading Nom In Val / In Val In Type Out Val 35.00 / 35.00 %Volume 35.00 8411 Garvey Drive, Suite 113 Raleigh, NC 27614 Toll -free: (866) 646-PINE (7463) State Certified Status Pass Temp °C 20 Humidity % 37 Range Ace % 0.0000 Reading Ace % 3.0000 Plus/Minus 0.00 Fnd As Lft As 51.00 50.00 Range Ace % 0.0000 Reading Ace % 3.0000 Plus/Minus 0.00 Out Tvp_e Fnd As Lft As %Volume 35.70 35.00 Dev% Pass/Fail 0.00% Pass Dev% Pass/Fail 0.00% Pass Group # 3 Range Ace % 0.0000 Group Name Oxygen Reading Ace % 3.0000 Stated Accy Pet of Reading Plus/Minus 0.00 Nom In Val / In Val In Type Out Val Out Type Fnd As Lft As Dev% Pass/Fail 20.90 / 20.90 %Volume 20.90 %Volume 20.90 20.90 0.00% Pass Group # 4 Group Name Carbon Monoxide Stated Accy Pet of Reading Nom In Val / In Val In Type Out Val Out Type 1000.00 / 1000.00 PPM 1000.0C PPM Group # 5 Group Name H2S Stated Accy Pet of Reading Nom In Val / In Val In Type Out Val 50.00 / 50.00 PPM 50.00 Range Ace % 0.0000 Reading Acc % 3.0000 Plus/Minus 0.00 Fnd As Lft As Dev% Pass/Fail 997.00 1,000.00 0.00% Pass Range Ace % 0.0000 Reading Ace % 3.0000 Plus/Minus 0.00 Out Tvp a Fnd As Lft As Dev% Pass/Fail PPM 49.00 50.00 0.00% Pass Pine Environmental Services LLC Windsor Indust ial Park, 92 Norh Main Street, Bldg 20, Windsor, NJ 08561, 800-301-9663 vwr.p ine-envirojunental.com INSTRUMENT CA LIBRA,rJoN REPORT Pine Environmental Services LLC 8411 Garvey Drive, Suite 113 Raleigh, NC 27614 Toll -free: (866) 646-PINE (7463) Pine Environmental Services, Inc. r Instrument ID 41616 Description Gem 5000 Calibrated 11/15/2019 1:40:28PM Test Instruments Used During the Calibration Test Standard ID Description Manufacturer NC 50/35 NC 50 CH4/35 CO2 Gasco MAP-399-5 1/20 NC CO CARBON Pine 1000/H2S50 MONOXIDE/HYDRO GEN SULFIDE Notes about this calibration Calibration Result Calibration Successful Who Calibrated Blaine Bunch Serial Number 1 Model Nuwb(tr Lot Number GP 12126 - = ] ;03 MAP-399-5 BBH-408BST- 1 As Of Cal Entry Date) Next Cal Date / Last Cal Date/ Expiration Date Opened Date 1/20/2020 All instruments are calibrated by Pine Environmental Servio2s LLC according to the manufacturer's specifications, but it is the customer's responsibility to calibrate a id maintain this unit in accordance with the manufacturer's specifications and/or the custorer's own specific needs. Notify Pine Environmental Services LLC of any defect Zvi t Un 24 hours of receipt of equipment Please call 800-301-9663 for Techn cal Assistance Pine Environmental Services LLC Windsor Industrial Park, 92 North Main Street, Bldg 20, Windsor, NJ 08561, 800-301-9663 www.pine-environmental. zo ni