Loading...
HomeMy WebLinkAboutMO-9472_40914_CA_IAR_20190521_InitialAbatementActionReportConsulting Engineers September 26, 2019 GEOSCIENCE GROUP Ms. Trudy Beverly, L.G. NCDEQ Mooresville Regional Office UST Section 610 East Center Avenue, Suite 301 Mooresville, North Carolina 28115 RE: Initial Abatement Action Report 1139 Harding Place Charlotte, North Carolina 28204 Incident #: N/A Dear Ms. Beverly: Attached is the Initial Abatement Report, the soil sampling results, maps, and photographs. Please contact me at (704) 941-2262 if you have any questions. Facs,miM NC License 704.5252051 F-0585 May 21, 2019 GEQSCIENCE GROUP Consulting Engineers North Carolina Department of Environmental Quality Division of Waste Management 610 East Center Avenue, Suite 301 Mooresville, North Carolina 28115 Attention: Underground Storage Tank Section Reference: Initial Abatement Action Report 1139 Harding Place Charlotte, North Carolina Geoscience Project No. CH18.0135.EV Incident No. N/A This Initial Abatement Action Report summarizes the removal of an underground storage tank (UST) that was formerly used to store heating oil for the house at 1139 Harding Place. Site Name: 1139 Harding Place UST Owner/Operator: Unknown Consultant: Geoscience Group, Inc. 500 Clanton Road, Suite K Charlotte, North Carolina 28217 (704)525-2003 Date Discovered: May 1, 2019 Quantity of Release: Unknown Source of Release: UST Site Location: 1139 Harding Place Charlotte, North Carolina 28204 Property Owner: Well Pappas Berkeley Owner, LLC 4777 Sharon Road, Suite 550 Charlotte, North Carolina 28210 Laboratory: Prism Laboratories, Inc. 449 Springbrook Lane Charlotte, North Carolina 28224 (704)529-6364 Latitude/Longitude: 35.21081/-80.83970° Cause of Release: Tank Corrosion System Contents/Size: Heating Oil, 500-gal, Professional Engineer for Geoscience Group, Inc., do certify that the lie report is correct and accurate to the best of my knowledge. North Cafb}�, ' W`No. 035050 Geoscience Group, Inc. is licensed to practice engineering in North Carolina. The certification number of the company is F-0585. Enclosures P'.../INV/201035-Bakdq/UST/1135a.. Rpt.dec 502 L3ro� Row C^arlc"e Nort" Ca•ohna Teleplone Seite u 2821; 70-t.525 2003 Facsimile NC License 704 525.2051 F-0585 Geoscience Project No. CH18.0135.EV May 21, 2019 Page 2 SITE HLSTORYAND CHARACTERIZATION The subject property is a 0.275t acre tract located along the northeastern side of Harding Place, immediately north of its intersection with Berkeley Avenue in Charlotte, North Carolina. The site consists of Mecklenburg County Tax Parcel ID No. 12520222. The property is occupied by a two house that was built sometime before 1929. The footprint of the house is shown on Figure CH18.135-A in Appendix R. The installation and usage dates for the former storage tank (UST-1) are not known. As shown on the Site Layout Figure, No. CH18.135-A, UST-1 was located adjacent to the northeastern comer of the house. No other USTs have been encountered on Parcel No. 12520222 and no other USTs are known to have been used at the parcel. Based on review of the 1985 Geologic Map of North Carolina, the subject site is located within the Charlotte Belt of the Piedmont Physiographic Province. This Province is generally characterized by igneous intrusive and metamorphic bedrock that is Permian to Ordovician in age. The intrusive rock is typically overlain with a layer of soil and weathered rock, ranging in thickness from 0 to 150 feet. Bedrock within the Charlotte Belt consists primarily of the diorite -granite complex, with the granite appearing to be the predominant component of the complex. According to the Geologic Map, the subject site is underlain with granitic rock. According to the 1967 (Photorevised in 1988) "Charlotte East, North Carolina" United States Geological Survey (USGS) 7.5-minute quadrangle map, the subject site is located between approximately 652 and 664 feet above mean sea level (MSL). The ground surface across the project site generally slopes downward toward the east. The low elevation of 652 feet MSL is located at the southeastern property corner and the high elevation of 662 feet MSL is located on the northwestern corner of the site. CLOSURE PROCEDURES Geoscience was on site on May 1, 2019 to monitor the removal of UST4. EVO Corporation (EVO) was contracted to remove the tank. Prior to excavation, a vacuum truck was used to remove residual fluids from the tank. Approximately 275 gallons of water mixed with fuel oil were removed from UST-1. The product removed from the tank was transported to EVO's facility for proper disposal. A copy of the Certificate of Disposal for the product are included in Appendix V for your review. The clean overburden on top of the tank was removed and stockpiled on -site. The tank was then removed from the ground. The exterior of the UST-1, shown in Photographs 1 through 3 in Appendix Ill, exhibited obvious corrosion through holes at one end of the tank. The Geoscience Project No. CHI8.0135.EV May 21, 2019 Page 3 tank was subsequently transported to EVO's facility for proper disposal. A copy of the Tank Disposal Certificate is included in Appendix V. UST-1 was approximately 93 inches long and 40 inches in diameter for an estimated capacity of 500 gallons. SITE INVESTIGATION After removal of the tank, the soils beneath it were examined for indications of a petroleum release. Minor staining and petroleum odors were noted in the soils beneath the northwestern end UST-1, at the location of the corrosion through holes. No free product was encountered in the tank basin. A total of two (2) soil samples (S-1 and S-2) were collected approximately eighteen (18) inches beneath the centerline of the tank near the ends of the tank basin. The approximate locations of the soil samples are depicted on Figure CH18.135-13 in Appendix II. The samples were placed in laboratory -provided containers, packed on ice, and transported in a cooler under appropriate chain -of -custody procedures to Prism Laboratories, Inc. (Prism) of Charlotte, North Carolina for chemical analyses. Each soil sample was analyzed for Gasoline -Range Organics (TPH-GRO) and Diesel -Range Organics (TPH-DRO) using EPA Methods 5030 and 3550, respectively. The results of soil analyses are summarized in Table B-3 in Appendix L As shown, TPH-DRO and TPH-GRO were detected in sample S-2 at concentrations of 6,300 mg/kg and 210 mg/kg, respectively. These concentrations exceed the 100mg/kg TPH DRO action level and 50 mg/kg TPH-GRO action level established by the UST Section. The results from sample S-1 did not exceed laboratory reporting limits. A copy of the laboratory test report is included in Appendix IV. POTENTLIL RECEPTORS Geoscience conducted a walking survey of the area within 150 feet of UST-1. No potential receptors were noted. Specifically, no water supply wells or surface waters were noted within 150 feet of the release area. CONCLUSIONS Geoscience has observed and documented the closure of a UST formerly located at 1139 Harding Place in Charlotte, North Carolina. The tank was previously used to store heating oil and was approximately 500 gallons in capacity. The installation and usage dates of the tank are not known. Soil sampling conducted following removal of the UST confirms that the soils immediately beneath the tank have been impacted by a release of petroleum. Soils remain in place that exceed the 100 mg/kg TPH-DRO and 50 mg/kg TPH-GRO action levels. Geoscience Project No. CH18.0135.EV May 21, 2019 Page 4 Given that no water supply wells are located within 150 feet of the release area, Geoscience anticipates that a "No Further Action" determination could be obtained by filing an appropriate "Notice of Residual Petroleum". However, based on the existing soil sample results, the "Notice of Residual Petroleum" would likely include a restriction on the use of groundwater at the site and an excavation restriction in the UST-1 basin area. Additional assessment and/or soil remediation would be required to avoid these restrictions. APPENDIXI Tables: Table B-1: Site History - UST/AST System and Other Release Information Table B-2: Site History - UST/AST Owner/Operator and Other Responsible Party Information Table B-3: Summary of Soil Sampling Results N E m Z C N U C Q z 71, Aa@me�com0 e 0 / E f ` ~ ° 0 L E E A ~ ~ _ ) } { \ / - J { / G a £ w 0 # 0 2 / J 2 o k 2 £ J 2 y } / 2 z APPENDIX H Figures: Figure No. CHI 8.135-A - Site Layout Figure No. CHI 8.135-13- Sample Location Diagram Extent i GEOSCIENCE GROUP, INC. CHARLOTTE, NORTH CAROLINA SCALE: I"= IO' APPROVEW DRAWN BY: Mecklenburg Co. N DATE: May 21, 2019 REVISED: TCH 1139 HARDING PLACE CHARLOTTE, NORTH CAROLINA SAMPLE LOCATION DIAGRAM FIGURENUMBER: CH18.135-B APPENDIX III Site Photographs APPENDIX TV Laboratory Reports i ! 6 Full -Service Analytical & F, R I S M I Environmental Solutions LA00nATORIE$ MG Geoscience Group Tom Hassett 500-K Clanton Rd. Charlotte, NC 28217 NC Certification No. 402 NC Drinking Water Cart No. 37735 SC Certification No. 99012 Project: 1139 Harding Place Lab Submittal Date: 05/01/2019 Prism Work Order: 9050050 Case Narrative 5/13/19 10:36 This data package contains the analytical results for the project identified above and includes a Case Narrative, Sample Results and Chain of Custody. Unless otherwise noted, all samples were received in acceptable condition and processed according to the referenced methods. Data qualifiers are flagged individually on each sample. A key reference for the data qualifiers appears at the end of this case narrative. Please call if you have any questions relating to this analytical report. Respectfully, PRISM LABORATORIES, INC. a, --I Angela D. Overcash VP Laboratory Services Data Qualifiers Key Reference: Reviewed By Angela D. Overcash VP Laboratory Services DO Surrogates diluted out. M Matrix spike outside of the control limits. RLM Sample container suspected to have low methanol content. Results possibly biased high. SR Surrogate recovery outside the CC limits. BRL Below Reporting Limit MDL Method Detection Limit RPD Relative Percent Difference Results reported to the reporting limit. All other results are reported to the MDL with values between MDL and reporting limit indicated with a J. This report should not be reproduced, except in its entirely, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240W - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1.800/529-6364 - Fax: 7041525-0409 PP.ISn A I Full-6ervlce Analytical& Summary of Detections V Environmental Solutions �_ __. ueoanosiEs i.c 05/13/2019 Prism Work Order: 9050050 Prism ID Client ID Parameter Method Result Units 9050050-02 S-2 Diesel Range Organics *8015C 6300 mg/kg dry 9050050-02 S-2 Gasoline Range Organics *8015C 210 mglkg dry This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 7041529.6364 -Toll Free Number: 1-800152"364 • Fax: 7041525-0409 �R I S M I FI1-Service Analytical a Environmental Solutions �'ueo.'acwc Geoscience Group Attn: Tom Hassett 500-K Clanton Rd. Charlotte, NC 28217 Project: 1139 Harding Place Sample Matrix: Solid Laboratory Report 05/13/2019 Client Sample ID: S-2 Prism Sample ID: 9050050-02 Prism Work Order: 9050050 Time Collected: 05/01/19 11:10 Time Submitted: 05/01/19 11:41 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor DateTme ID Diesel Range Organics by GC/FID Diesel Range Organics _ 6300 _ mglkg dry Soo 170 s0 '8015C 5/6/19 11:15 BGB P9E0071 Surrogate Recovery Control Limits o-Terphenyl 0 % 31-123 DO Gasoline Range Organics by GC/FID Gasoline Range Organics 210 mglkg dry _ 16 4.3 _ 100 _ -8015C 513119 16:48 TBL P9E0054 Surrogate Recovery Control Limits a, a, a-Trifluorotoluene General Chemistry Parameters %Solids 70.1 %by 0.100 0.100 1 Weight 120 % 50-137 'SM2540 G 5/9119 9:20 KBS P9E0147 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P,O. Box 240543 - Charlotte, NC 28224-0543 Phone: 7041529.6364 -Toll Free Number: 1-800/529-6364 - Fax: 7041626-0409 �3RISM I Full -Service Analytical Environment al SolutionstlDaS �`LA60XMONF$IXF Geoscience Group Attn: Tom Hassett 500-K Clanton Rd. Charlotte, NC 28217 Project: 1139 Harding Place Diesel Range Organics by GC/FID - quality Control Batch P9E0071 - 3546 Level II QC Report 5113119 Prism Work Order: 9050050 Time Submitted: 5/1/2019 11:41:OOAM Reporting Spike Source %REC RPD Result Limit Units Level Result %REC Limits RPD Limit Notes Blank (P9EO071-BLK1) _ Prepared &Analyzed: 05/03/19 Diesel Range Organics BRL 7.0 mg/kg wet - -- -- - Surrogate: a-Teiphenyl 1.18 mg/kg wet 1.333 89 31-123 LCS (P9E0071-BS1) _ _ _ & Analyzed: 05/03/19 Diesel Range Organlcs 64.2 7.0 m g/kg wet _Prepared 66.67 96 - - 46-126 Surrogate: o-Terphenyl 1.49 mg/kg wet 1.333 112 31-123 LCS Dup (P9E0071-BSD7) Prepared Analyzed: 05/03/19 Diesel Range Organics 64.0 7.0 mg/kg wet _&_ 66.67 96 _ 46-126 0.4 20 _— Surrogate: o-Terphenyt 1.42 m 9&8 wet 1.333 106 31-123 Sample Extraction Data Prep Method: 3646 Lab Number Batch Initial Final DataTme 9050050-01 P9E0071 30.02 g 1 mL 05/03/19 10:65 9050050-02 P9E0071 30.04 g 1 mL 05/03/19 10:65 Prep Method: 5030B Lab Number Batch Initial Final Daternme 9050050-01 P9E0054 4.69 mL 5 mL 05/03/19 7:53 9050050-02 P9E0054 4.58 mL 5 mL 05/03/19 7:53 This report should not be reproduced, except in its entirety, without the written consent of Prism Labomtodes, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 7041529-6364 - Toll Free Number: 1.8001529.6364 - Fax: 7041525-0409 APPENDIX V Disposal Documents -�nrc-�vc CORPORATION 1703 Vargrave street Wwton-Sefem, NO 27107 Ph 335-725-M44 im 338-7254R44 TANK DISPOSAL CERTIFICATE Tank Owner: Well Pappas Berkeley Owner, LLC Site Address: 1139 Harding Place Charlotte, NC Description of Tanks: Tank Size of Tank Contents Number 1 550 Gallons #2 Fuel Oil Transporter: Evo Corporation EC Project #: 051907 Disposal Certification: Evo Corporation does hereby certify that the above named storage tank was transported to Foss Recycling, 3459 Thomasville Road, Winston-Salem, NC for proper disposal and recycling. Signature CORPORATION. 1703 Vargrave Street Winston-6alern, NO 27107 ph 336-725-SW fax 336-725-6244 CERTIFICATE OF DISPOSAL Evo Corporation does hereby certify that 275 gallons of product received on 5/1/2019 from: Generator: Well Pappas Berkeley Owner, LLC Originating at: 1139 Harding Place Charlotte, NC EC Waste ID #: 051907 has been disposed of by Evo Corporation in a manner approved by the North Carolina Department of Environmental Quality. Signature Thomas W. Hammett CEO Evo Corporation EVO CORPORATION 1703 Vargrave Street, Winston-Salem, NC 27107 www.evocorp.net NON -HAZARDOUS MATERIALS MANIFEST Load # AA Generator. Well PaPPas Berkeley Owner, LW Site Address 139 Harding P1 City/State: �'harl�rtlp Ht' n �nw No. . 81167 Phone: 704-44DO-3493 Contact: J;m % hnM2Chpr Gross Weight (Ibs): Material: Product Empty Weight (Ibs): Contaminant: Fael Oil Net Weight (lbs): Quantity a115" Tons Drums Pails Sacs Yards Other: ' wl:; ,EN Transporter:Eyo Corporation Phone: 336-725-5844 Truck #: Contact: Tony-Dis'her As the transporter, I certify that the materials described above being shipped under this non -hazardous materials manifest are properly classified, packaged, labeled, secured and are In proper condition for transport In commerce under the applicable regulations governing transportation, and I hereby receive this material for delivery to the facility designate. EVO CORPORATION Evo Project #: 051907 1703 Vargrave Street Phone: Q38) 725-5844 Winston-Salem, NC 27107 Contact: Tony Disher I certify that the carrier has delivered the materials described above to this facility, and I hereby accept this material for treatment and/ gr�disposal_Ir� a manner that has been authorized by the State of North Carolina. Etio Corporation, 2008 EC-302