HomeMy WebLinkAbout5705_INSP_20190924FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management
Solid Waste Section
Page 1 of 2
UNIT TYPE:
Lined MSWLF LCID YW Transfer Compost X SLAS COUNTY: Macon
Closed MSWLF HHW White goods Incin T&P FIRM PERMIT NO.: 57-05
CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF FILE TYPE: COMPLIANCE
Date of Site Inspection: 10/24/2019 Date of Last Inspection: 4/5/2018
FACILITY NAME AND ADDRESS:
B & B Concrete Products, Inc.
1687 Georgia Highway
Franklin, N. C. 28734
GPS COORDINATES: N: 35.15218° W: 83.39338° FACILITY CONTACT NAME AND PHONE NUMBER:
Name: Nelson Bates & Jeremy Decker
Telephone: 828-524-6483
Email address: bbconcrete@frontier.com
FACILITY CONTACT ADDRESS:
Same as above
PARTICIPANTS:
Troy Harrison, Solid Waste Section
Jeremy Decker, B & B Concrete Products, Inc.
STATUS OF PERMIT:
Active Permit Issued: October 24, 2014
Expires: October 24, 2019 PURPOSE OF SITE VISIT: Routine Inspection STATUS OF PAST NOTED VIOLATIONS: N/A OBSERVED VIOLATIONS: N/A
The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules.
FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management
Solid Waste Section
Page 2 of 2
ADDITIONAL COMMENTS
1. This facility is permitted to operate a Small Type III composting facility. 2. The only materials included in the compost pile were wood chips, brush from a grinding operation and grease
from restaurants. The normal composition is 20 yards of grease and 40 yards of chips/brush.
3. Little odor was observed at the pile. No flies or other vectors were observed. 4. The compost is located on top of a 40’ X 40’ concrete pad and leachate normally drains to one side into a drain
which empties into a septic tank. 5. As a reminder, the drain needs to be clear of debris and kept open to allow leachate to drain into the holding
tank. 6. The site is not open to the public. Access is by a single private road that is staffed during working hours.
7. Temperature and other records were kept in the main office and reviewed. Temperatures and turning frequency were observed being recorded. Required temperatures were being achieved. Please contact me if you have any questions or concerns regarding this inspection report. ________________________________ Phone: 828-296-4701 Troy Harrison Environmental Senior Specialist Regional Representative
Sent on: 10/24/2019 X Email Hand delivery US Mail Certified No. [ _]
Copies: NC Solid Waste Section Files