Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
7407_Pitt_CandDLandfillInc_20190927_LFG_FID1358626
DENR USE ONLY [:]Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #: NC DENR Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Wood Environment & Infrastructure Solutions, Inc Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Stephen Jeltema Phone: 919.765.9979 E-mail: Stephen. leltema(a)woodplc.com NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) C&D Landfill, inc. 802 Recycling Lane 7407-CDLF-200 .0500 September 26, 2019 Greenville, NC 27834 9 Environmental Status: (Check all that apply) Initial/Background Monitoring ❑X Detection Monitoring Assessment Monitoring Corrective Action T e of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells ❑X Methane gas monitoring data Groundwater monitoring data from private water supply wells ❑ Corrective action data (specify) Leachate monitoring data Surface water monitoring data Other(specify) Notification attached? eX No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. ❑ Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Sheri Knox Project Manager 919.381.9913 ,, Facility Representative Name (Print) Title (Area Code) Telephoo u e rZd ` Affix` is •~(S ogist Seal Signature Date :2 SEAL < 4021 Stirrup Creek Drive, Suite 100, Durham NC 27703 5-85 Facility Representative Address N 0, /7/0 �I y `� .GINE�,'' o F-1253 NC PE Firm License Number if applicable effective May 1, 2009) Revised 6/2009 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: G,06,b L.IZ, l Permit Number: Sampling Date: 1NC Landfill Rule (.0500 or. 1600): Sample Collector Name & Position: chi -0 k- 7ee�r ; e er� Gas Meter Type & Serial Number: Gas Meter Calibration Date: 41?1!n1 Field Calibration Date & Time: Field Calibration Gas Type (15115or 35/50): /� Field Calibration Gas Canister Expiration Date: Gas Meter Pump Rate: lZ 4 Ambient Air Temperature: t%` Barometric Pressure (in. or mm Hg): �G Weather Conditions: _ Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized % LEL % CH4 (volume) % 02 (volume) % CO2 (volume) % H2S# (volume) NOTES ?-/o 30 0 fY" c9 l91, J, 7 % G P o 100 e) 0,0 a, 3 -01P 50 Id7oS 0t0 010 an 70, t Z t -j 3b lo S oto oo a F 6,ce e S67-0 t n —ac ® t9, 6,7 96-17 3-0 0 0,0 Zt I - 3o O o© - %J J?0 AIC 3 0,0 0/0 t9in i g, � 61(-, o - JD //z S' an 0,0 eqxo/ 9, ;(1,-- 3 - -30 1137 1/S— L9,n 0,,0 chi, - 2015 ©, IV a MUA NOTE: If needed, attach additional data fornis to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification incl ing the possibility of a fine and imprisonment. SIGNATURE TITLE Revised — March 6, 2017 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice. This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: 412,-1b 40661 Permit Number: Sampling Date: Zal NC Landfill Rule (.0500 or.1600): •'Dc5 D� Sample Collector Name & Position: rS, ae 1,464-e, 21 K.2�tCyu�� Gas Meter Type & Serial Number:1tft� Gas Meter Calibration Date: Field Calibration Date & Time: M&,// l Sys Field Calibration Gas Type (15/15 or 35/50): /S� Field Calibration Gas Canister Expiration Date: Gas Meter Pump Rate: ?7 /Gr Ambient Air Temperature: '*`� Barometric Pressure (in. or mm Hg):I Weather Conditions: c4elj Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized % LEL % CH4 (volume) % 02 (volume) % CO2 (volume) % H2S" (volume) NOTES Csil —/3 IiI3 k5— oo a O 0 )%i� �t�i -©�o l��o �, ©,o © 16,1 ,© t'-/Z 210 Z400 ®o Gip- Z 7 ©lo ap PPW P- o / ,- o e 6° / o ppw D 30 t 3 V57- t 0 0,p 0,0 17 ,5- �3, aP 02- -AP 1 1 5- ©o b,b 76,3 D, l�-0 410 NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTIONLEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification incl ing the possibility of a fine and imprisonment. SIGNATURE TITLE Revised — March 6, 2017 a REV < W LL < g gk e 3 7s s a s h 5 Z> 2 g $ 3 S Ewa ° U' `Q �� =ter: �`>_, �<a z '� LL• a 3 zo, �2„ s QQ s O 00 VZJ Z Ir 7 - �E - _ 3s�wIL WWo - Est Ea m a co ��;; `\ • \ CD Z -- i Z a > o_ o �_ o 1 (• // \ g p co Cl- ji CD - v CD \ � , i �X R a to C7 t xe�� \\•� t to O_� �\ qb _ C1 CL \� \ � R t cn U ca s (DJ a of ` � m 2 � � CY c):! co Ix IX ! p CD Z, a u w