Loading...
HomeMy WebLinkAboutMO-9471_40913_CA_IAR_20190121_Initial Action Abatement ReportJanuary 21, 2019 Consulting Engineers GEOSC1ENCE GROUP North Carolina Department of Environmental Quality Division of Waste Management 610 East Center Avenue, Suite 301 Mooresville, North Carolina 28115 Attention: Underground Storage Tank Section Reference: Initial Abatement Action Report 1128 Greenwood Cliff Charlotte, North Carolina Geoscience Project No. CH18.0135.EV Incident No. PENDING This Initial Abatement Action Report summarizes the removal of an underground storage tank (UST) that was formerly used to store heating oil for the house at 1128 Greenwood Cliff. Site Name: 1128 Greenwood Cliff UST Owner/Operator: Unknown Consultant: Geoscience Group, Inc. 500 Clanton Road, Suite K Charlotte, North Carolina 28217 (704) 525-2003 Site Location: 1128 Greenwood Cliff Charlotte, North Carolina 28204 Property Owner: D&R Properties of Charlotte, LLC 1131 Harding Place Charlotte, North Carolina 28204 Laboratory: Prism Laboratories, Inc. 449 Springbrook Lane Charlotte, North Carolina 28224 (704) 529-6364 Date Discovered: January 9, 2019 Latitude/Longitude: 35.2111801-80.839580 Quantity of Release: Unknown Cause of Release: Tank Corrosion Source of Release: UST System Contents/Size: Heating Oil, 500-gal. e1116891110g I, Tho5 1AM9 '14. Professional Engineer for Geoscience Group, Inc., do certify that the mfOl*AK�8 As report is corr_ct, and accurate to the best of my knowledge. North o. 035050 Geoscience Group, Inc. is licensed to practice engineering in North Carolina. The certification number of the company is F-0585. Enclosures P..'.../ENV/2o18!135—Berke1WUST/11280osu Rpt.doc 500 Clanton Road Charlotte, North Carolina Telepnone arsirrme NC License Suite K 28217 704.525.2003 '04.525.2051 F-0585 Geoscience Project No. CH18.0135.EV January 21, 2019 Page 2 SITE HISTORYAND CHARACTERIZATION The subject property is a 0.177f acre tract located along the southwestern side of Greenwood Cliff, approximately 140 feet northwest of its intersection with Berkeley Avenue in Charlotte, North Carolina. The site consists of Mecklenburg County Tax Parcel ID No. 12520210. The property is occupied by a one-story house that was built sometime before 1929. The house was converted for commercial use in approximately 1994. The footprint of the house is shown on Figure CHI 8.135-A in Appendix II. The installation and usage dates for the former storage tank (UST-1) are not known. As shown on the Site Layout Figure, No. CH18.135-A, UST-1 was located adjacent to the southern corner of the house. No other USTs have been encountered on Parcel No. 12520210, and no other USTs are known to have been used at the parcel. Based on review of the 1985 Geologic Map of North Carolina, the subject site is located within the Charlotte Belt of the Piedmont Physiographic Province. This Province is generally characterized by igneous intrusive and metamorphic bedrock that is Permian to Ordovician in age. The intrusive rock is typically overlain with a layer of soil and weathered rock, ranging in thickness from 0 to 150 feet. Bedrock within the Charlotte Belt consists primarily of the diorite -granite complex, with the granite appearing to be the predominant component of the complex. According to the Geologic Map, the subject site is underlain with granitic rock. According to the 1967 (Photorevised in 1988) "Charlotte East, North Carolina" United States Geological Survey (USGS) 7.5-minute quadrangle map, the subject site is located between approximately 650 and 662 feet above mean sea level (MSL). The ground surface across the project site generally slopes downward toward the east. The low elevation of 650 feet MSL is located at the eastern property corner and the high elevation of 662 feet MSL is located on the western corner of the site. CLOSURE PROCEDURES Geoscience was on site on January 2 and 3, 2019 to monitor the removal of UST-1. EVO Corporation (EVO) was contracted to remove the tank. Prior to excavation, a vacuum truck was used to remove residual fluids from the tank. Approximately 200 gallons of water mixed with fuel oil were removed from UST-1. The product removed from the tank was transported to EVO's facility for proper disposal. A copy of the Certificate of Disposal for the product are included in Appendix V for your review. The clean overburden on top of the tank was removed and stockpiled on -site. The tank was then removed from the ground. The exterior of the UST-1, shown in Photographs 1 and 2 in Appendix III, exhibited obvious corrosion through holes. The tank was subsequently Geoscience Project No. CHI 8.0135.EV January 21, 2019 Page 3 transported to EVO's facility for proper disposal. A copy of the Tank Disposal Certificate is included in Appendix V. UST-1 was approximately 78 inches long and 46 inches in diameter for an estimated capacity of 500 gallons. SITE INVESTIGATION After removal of the tank, the soils beneath it were examined for indications of a petroleum release. Neither staining nor petroleum odors were noted in the soils beneath UST-1. No free product was encountered in the tank basin. A total of two (2) soil samples (1128 Green-1 and 1128 Green-2) were collected approximately eighteen (18) inches beneath the centerline of the tank near the ends of the tank basin. The approximate locations of the soil samples are depicted on Figure CH18.135-13 in Appendix II. The samples were placed in laboratory -provided containers, packed on ice, and transported in a cooler under appropriate chain -of -custody procedures to Prism Laboratories, Inc. (Prism) of Charlotte, North Carolina for chemical analyses. Each soil sample was analyzed for Gasoline -Range Organics (TPH-GRO) and Diesel -Range Organics (TPH-DRO) using EPA Methods 5030 and 3550, respectively. The results of soil analyses are summarized in Table B-3 in Appendix I. As shown, TPH-DRO was detected in sample 1128 Gree-1 at a concentration of 1,200 mg/kg. This concentration exceeds the 100mg/kg action level established by the UST Section for TPH-DRO. No other result exceeded its respective action level concentration. A copy of the laboratory test report is included in Appendix IV. POTENTIAL RECEPTORS Geoscience conducted a walking survey of the area within 150 feet of UST-1. No potential receptors were noted. Specifically, no water supply wells or surface waters were noted within 150 feet of the release area. CONCLUSIONS Geoscience has observed and documented the closure of a UST formerly located at 1128 Greenwood Cliff in Charlotte, North Carolina. The tank was previously used to store heating oil and was approximately 500 gallons in capacity. The installation and usage dates of the tank are not known. Soil sampling conducted following removal of the UST confirms that the soils immediately beneath the tank have been impacted by a release of petroleum. Soils remain in place that exceed the 100 mg/kg TPH-DRO action level. Given that no water supply wells are located within 150 feet of the release area, Geoscience anticipates that a "No Further Action" determination could be obtained by filing an appropriate "Notice of Residual Petroleum". However, based on the existing soil sample Geoscience Project No. CHI 8.0135.EV January 21, 2019 Page 4 results, the "Notice of Residual Petroleum" would likely include a restriction on the use of groundwater at the site and an excavation restriction in the UST-1 basin area. Additional assessment and/or soil remediation would be required to avoid these restrictions. APPENDIX I Tables: Table B-l: Site History - UST/AST System and Other Release Information Table B-2: Site History - UST/AST Owner/Operator and Other Responsible Party Information Table B-3: Summary of Soil Sampling Results O O 3 c a) C9 00 N r a) E C6 z c a) U C O C C a) a_ C� N O U E C z 1 O N r co C (D a) 2 c� Co O z a� m °c E > r O aEic� a) Co C c a) a)m U) O O •E 0),- O C O m E C O O N ca r O � f06 OQ) N C LO Co O .0 L N a) CU c :3 0 O O E p O cu j O o cc O m C: U X ca a) 3 O O a) 0 U) O C L O O O U U U Q O w E j U D O O > O O c Q d d co C 3 O C Y C V cm C co (Cf U a 0 3 B c aa)i O 0 Q OD N N L d .0 O C N _ co C Z L O Q O +;+ O E � = o a O H U) Q � L M E —Z O 0)W� YI [T N d � co N � m � cu Ri O to CL E to cn 0 cn 4- 0 m E E co W M -I.- Rh 6 co 0 NO ai E co z APPENDIX II Figures: Figure No. CHI 8.135-A - Site Layout Figure No. CH18.135-13 - Sample Location Diagram am [it Approximate Extent of Excavation SCALE: 1" z 10' TE: January 21, 2019 GEOSCIENCL GROUP, INC. CHARLOTTE, NORTH CAROLINA BY: - I J 'DRAWN BY: Mecklenburg Co. 1128 GREENWOOD CLIFF CHARLOTTE, NORTH CAROLINA ANP SAMPLE LOCATION DIAGRAM E NUMBER: CH18.135-B APPENDIX III Site Photographs APPENDIX IV Laboratory Reports Case Narrative PRISM `,. LABORATORIES, INC. Geoscience Group Tom Hassett 500-K Clanton Rd. Charlotte, NC 28217 NC Certification No. 402 Full -Service Analytical & NC Drinking Water Cert No. 37735 Environmental Solutions SC Certification No. 99012 Project: Berkeley Lab Submittal Date: 01/02/2019 Prism Work Order: 9010009 01 /09/2019 This data package contains the analytical results for the project identified above and includes a Case Narrative, Sample Results and Chain of Custody. Unless otherwise noted, all samples were received in acceptable condition and processed according to the referenced methods. Data qualifiers are flagged individually on each sample. A key reference for the data qualifiers appears at the end of this case narrative. Please call if you have any questions relating to this analytical report. Respectfully, PRISM LABORATORIES, INC. a,j Angela D. Overcash VP Laboratory Services Data Qualifiers Key Reference: Reviewed By Terri W. Cole For Angela D. Overcash Project Manager M Matrix spike outside of the control limits. RLM Sample container suspected to have low methanol content. Results possibly biased high. SR Surrogate recovery outside the QC limits. BRL Below Reporting Limit MDL Method Detection Limit RPD Relative Percent Difference * Results reported to the reporting limit. All other results are reported to the MDL with values between MDL and reporting limit indicated with a J. This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 1 of 14 PRISMSample LABORATORIES INC. Full -Service Analytical R Environmental Solutions Receipt Summary 01/09/2019 Prism Work Order: 9010009 Client Sample ID Lab Sample ID Matrix Date/Time Sampled Date/Time Received 1127 Harding-1 9010009-01 Solid 01/02/19 11:21 01/02/19 13:12 1127 Harding-2 9010009-02 Solid 01/02/19 11:25 01/02/19 13:12 1127 Harding-3 9010009-03 Solid 01/02/19 11:45 01/02/19 13:12 1127 Harding-4 9010009-04 Solid 01/02/19 11:50 01/02/19 13:12 1135 Harding-1 9010009-05 Solid 01/02/19 12:00 01/02/19 13:12 1135 Harding-2 9010009-06 Solid 01/02/19 12:03 01/02/19 13:12 1128 Green-1 9010009-07 Solid 01/02/19 13:00 01/02/19 13:12 1128 Green-2 9010009-08 Solid 01/02/19 13:05 01/02/19 13:12 Samples were received at 33.4 degrees C. See case narrative for further information. This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 2 of 14 Summary of Detections P R Full -Service Analytical & I S M Environmental Solutions 01/09/2019 LABORATORIES, INC. Prism Work Order: 9010009 Prism ID Client ID Parameter Method Result Units 9010009-01 1127 Harding-1 Diesel Range Organics `8015C 67 mg/kg dry 9010009-02 1127 Harding-2 Diesel Range Organics '8015C 240 mg/kg dry 9010009-02 1127 Harding-2 Gasoline Range Organics '8015C 26 mg/kg dry 9010009-03 1127 Harding-3 Diesel Range Organics `8015C 72 mg/kg dry 9010009-07 1128 Green-1 Diesel Range Organics '8015C 1200 mg/kg dry 9010009-07 1128 Green-1 Gasoline Range Organics "8015C 41 mg/kg dry This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 3 of 14 PRISMLaboratory Report Full -Service Analytical & Environmental Solutions 01/09/2019 LABORATORIES INC. Geoscience Group Project: Berkeley Client Sample ID: 1127 Harding-1 Attn: Tom Hassett Prism Sample ID: 9010009-01 500-K Clanton Rd. Prism Work Order: 9010009 Charlotte, NC 28217 Sample Matrix: Solid Time Collected: 01/02/19 11:21 Time Submitted: 01/02/19 13:12 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor Date/Time ID Diesel Range Organics by GC/FID Diesel Range Organics 67 mg/kg dry 9.6 2.6 1 *8015C 1/4/19 19:26 BGB P9A0072 Surrogate Recovery Control Limits o-Terphenyl 76 % 31-123 Gasoline Range Organics by GC/FID Gasoline Range Organics BRL mg/kg dry 8.7 1.9 50 *8015C 1/7/19 20:08 ANG/J P9A0090 Surrogate Recovery Control Limits a,a,a-Trifluorotoluene 120 % 50-137 General Chemistry Parameters % Solids 72.5 % by 0.100 0.100 1 *SM2540 G 1/7/19 14:31 TJY P9A0098 Weight This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 4 of 14 /PRISM Full -Service Analytical s Environmental Solutions LABORATORIES INC. Geoscience Group Project: Berkeley Attn: Tom Hassett 500-K Clanton Rd. Charlotte, NC 28217 Sample Matrix: Solid Laboratory Report 01 /09/2019 Client Sample ID: 1127 Harding-2 Prism Sample ID: 9010009-02 Prism Work Order: 9010009 Time Collected: 01/02/19 11:25 Time Submitted: 01/02/19 13:12 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor Date/Time ID Diesel Range Organics by GC/FID Diesel Range Organics 240 mg/kg dry 92 24 10 *8015C 1/7/19 11:02 BGB P9A0072 Surrogate Recovery Control Limits Gasoline Range Organics by GC/FID Gasoline Range Organics 26 mg/kg dry 8.4 1.8 50 *8015C 1/8/19 9:41 ANGM P9A0090 Surrogate Recovery Control Limits General Chemistry Parameters % Solids 76.2 % by 0.100 0.100 1 *SM2540 G 1/7/19 14:31 TJY P9A0098 Weight This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 5 of 14 /PRISM Full -Service Analytical Environmental Solutions LABORATORIES INC. Geoscience Group Project: Berkeley Attn: Tom Hassett 500-K Clanton Rd. Charlotte, NC 28217 Sample Matrix: Solid Laboratory Report 01 /09/2019 Client Sample ID: 1127 Harding-3 Prism Sample ID: 9010009-03 Prism Work Order: 9010009 Time Collected: 01/02/19 11:45 Time Submitted: 01/02/19 13:12 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor Date/Time ID Diesel Range Organics by GC/FID Diesel Range Organics 72 mg/kg dry 9.1 2.4 1 *8015C 1/4/19 20:40 BGB P9A0072 Surrogate Recovery Control Limits Gasoline Range Organics by GC/FID RLM Gasoline Range Organics BRL mg/kg dry 5.0 1.1 50 *8015C 1/7/19 20:36 ANG/J P9A0090 Surrogate Recovery Control Limits General Chemistry Parameters % Solids 76.9 % by 0.100 0.100 1 *SM2540 G 1/7/19 14:31 TJY P9A0098 Weight This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 6 of 14 /PRISM Full -Service Analytical s Environmental Solutions LABORATORIES INC. Geoscience Group Project: Berkeley Attn: Tom Hassett 500-K Clanton Rd. Charlotte, NC 28217 Sample Matrix: Solid Laboratory Report 01 /09/2019 Client Sample ID: 1127 Harding-4 Prism Sample ID: 9010009-04 Prism Work Order: 9010009 Time Collected: 01/02/19 11:50 Time Submitted: 01/02/19 13:12 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor Date/Time ID Diesel Range Organics by GC/FID Diesel Range Organics BRL mg/kg dry 9.4 2.5 1 *8015C 1/4/19 21:17 BGB P9A0072 Surrogate Recovery Control Limits Gasoline Range Organics by GC/FID Gasoline Range Organics BRL mg/kg dry 7.7 1.6 50 *8015C 1/7/19 21:04 ANG/J P9A0090 Surrogate Recovery Control Limits General Chemistry Parameters % Solids 74.2 % by 0.100 0.100 1 *SM2540 G 1/7/19 14:31 TJY P9A0098 Weight This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 7 of 14 /PRISM Full -Service Analytical s Environmental Solutions LABORATORIES INC. Geoscience Group Project: Berkeley Attn: Tom Hassett 500-K Clanton Rd. Charlotte, NC 28217 Sample Matrix: Solid Laboratory Report 01 /09/2019 Client Sample ID: 1135 Harding-1 Prism Sample ID: 9010009-05 Prism Work Order: 9010009 Time Collected: 01/02/19 12:00 Time Submitted: 01/02/19 13:12 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor Date/Time ID Diesel Range Organics by GC/FID Diesel Range Organics BRL mg/kg dry 9.1 2.4 1 *8015C 1/5/19 0:23 BGB P9A0072 Surrogate Recovery Control Limits Gasoline Range Organics by GC/FID Gasoline Range Organics BRL mg/kg dry 6.0 1.3 50 *8015C 1/7/19 21:32 ANG/J P9A0090 Surrogate Recovery Control Limits General Chemistry Parameters % Solids 76.8 % by 0.100 0.100 1 *SM2540 G 1/7/19 14:31 TJY P9A0098 Weight This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 8 of 14 /PRISM Full -Service Analytical s Environmental Solutions LABORATORIES INC. Geoscience Group Project: Berkeley Attn: Tom Hassett 500-K Clanton Rd. Charlotte, NC 28217 Sample Matrix: Solid Laboratory Report 01 /09/2019 Client Sample ID: 1135 Harding-2 Prism Sample ID: 9010009-06 Prism Work Order: 9010009 Time Collected: 01/02/19 12:03 Time Submitted: 01/02/19 13:12 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor Date/Time ID Diesel Range Organics by GC/FID Diesel Range Organics BRL mg/kg dry 8.7 2.3 1 *8015C 1/4/19 22:32 BGB P9A0072 Surrogate Recovery Control Limits Gasoline Range Organics by GC/FID Gasoline Range Organics BRL mg/kg dry 6.7 1.4 50 *8015C 1/7/19 22:00 ANG/J P9A0090 Surrogate Recovery Control Limits General Chemistry Parameters % Solids 80.1 % by 0.100 0.100 1 *SM2540 G 1/7/19 14:31 TJY P9A0098 Weight This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 9 of 14 /PRISM Full -Service Analytical s Environmental Solutions LABORATORIES INC. Geoscience Group Project: Berkeley Attn: Tom Hassett 500-K Clanton Rd. Charlotte, NC 28217 Sample Matrix: Solid Laboratory Report 01 /09/2019 Client Sample ID: 1128 Green-1 Prism Sample ID: 9010009-07 Prism Work Order: 9010009 Time Collected: 01/02/19 13:00 Time Submitted: 01/02/19 13:12 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor Date/Time ID Diesel Range Organics by GC/FID Diesel Range Organics 1200 mg/kg dry 190 49 20 *8015C 1/7/19 12:16 BGB P9A0072 Surrogate Recovery Control Limits Gasoline Range Organics by GC/FID Gasoline Range Organics 41 mg/kg dry 8.3 1.8 50 *8015C 1/8/19 2:39 ANGM P9A0090 Surrogate Recovery Control Limits General Chemistry Parameters % Solids 75.1 % by 0.100 0.100 1 *SM2540 G 1/7/19 14:31 TJY P9A0098 Weight This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 10 of 14 /PRISM Full -Service Analytical s Environmental Solutions LABORATORIES INC. Geoscience Group Project: Berkeley Attn: Tom Hassett 500-K Clanton Rd. Charlotte, NC 28217 Sample Matrix: Solid Laboratory Report 01 /09/2019 Client Sample ID: 1128 Green-2 Prism Sample ID: 9010009-08 Prism Work Order: 9010009 Time Collected: 01/02/19 13:05 Time Submitted: 01/02/19 13:12 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor Date/Time ID Diesel Range Organics by GC/FID Diesel Range Organics BRL mg/kg dry 8.5 2.3 1 *8015C 1/5/19 1:38 BGB P9A0072 Surrogate Recovery Control Limits Gasoline Range Organics by GC/FID Gasoline Range Organics BRL mg/kg dry 6.1 1.3 50 *8015C 1/7/19 22:28 ANG/J P9A0090 Surrogate Recovery Control Limits General Chemistry Parameters % Solids 81.9 % by 0.100 0.100 1 *SM2540 G 1/7/19 14:31 TJY P9A0098 Weight This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 11 of 14 P R I IS M Full -Service Analytical Environmental Solutions LABORATORIES, INC. Level II QC Report 1 /9/19 Geoscience Group Project: Berkeley Attn: Tom Hassett 500-K Clanton Rd. Charlotte, NC 28217 Gasoline Range Organics by GC/FID - Quality Control Prism Work Order: 9010009 Time Submitted: 1/2/2019 1:12:OOPM Reporting Spike Source %REC RPD Analyte Result Limit Units Level Result %REC Limits RPD Limit Notes Batch MOON - 5035 Blank (P9A0090-BLK1) Prepared & Analyzed: 01/07/19 Gasoline Range Organics BRL 5.0 mg/kg wet Surrogate: a,a,a-Trifluorotoluene 5.00 mg/kg 5.000 100 50-137 LCS (P9A0090-BS1) Prepared & Analyzed: 01/07/19 Gasoline Range Organics 48.9 5.0 mg/kg wet 50.00 98 41-138 Surrogate: a,a,a-Trifluorotoluene 5.15 mg/kg 5.000 103 50-137 LCS Dup (P9A0090-BSD1) Prepared & Analyzed: 01/07/19 Gasoline Range Organics 52.7 5.0 mg/kg wet 50.00 105 41-138 7 Surrogate: a,a,a-Trifluorotoluene 5.15 mg/kg 5.000 103 50-137 Matrix Spike (P9A0090-MS1) Source: 9010009-01 Prepared & Analyzed: 01/07/19 Gasoline Range Organics 105 6.9 mg/kg dry 69.00 BRL 152 41-138 Surrogate: a,a,a-Trifluorotoluene 3.35 mg/kg 5.000 67 50-137 Matrix Spike Dup (P9A0090-MSD1) Source: 9010009-01 Prepared & Analyzed: 01/07/19 Gasoline Range Organics 114 6.9 mg/kg dry 69.00 BRL 166 41-138 9 Surrogate: a,a,a-Trifluorotoluene 5.15 mg/kg 5.000 103 50-137 20 M 34 M This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 12 of 14 P R 1 S M Full -Service Analytical s Environmental Solutions LABORATOR, Geoscience Group Project: Berkeley Attn: Tom Hassett 500-K Clanton Rd. Charlotte, NC 28217 Diesel Range Organics by GC/FID - Quality Control Level II QC Report 1 /9/19 Prism Work Order: 9010009 Time Submitted: 1/2/2019 1:12:OOPM Reporting Spike Source %REC RPD Analyte Result Limit Units Level Result %REC Limits RPD Limit Notes Batch P9AO072 - 3546 Blank (P9A0072-BLK1) Diesel Range Organics Surrogate: o-Terphenyl LCS (P9A0072-BSI) Diesel Range Organics Surrogate: o-Terphenyl LCS Dup (P9AO072-BSD1) Diesel Range Organics Surrogate: o-Terphenyl Matrix Spike (P9A0072-MS1) Diesel Range Organics Surrogate: o-Terphenyl Matrix Spike Dup (P9A0072-M Diesel Range Organics Surrogate: o-Terphenyl Prepared & Analyzed: 01/04/19 BRL 7.0 mg/kg wet 0.932 mg/kg wet 1.333 70 31-123 Prepared & Analyzed: 01/04/19 70.4 7.0 mg/kg wet 66.67 106 46-126 1.14 mg/kg wet 1.333 86 31-123 Prepared & Analyzed: 01/04/19 65.5 7.0 mg/kg wet 66.67 98 46-126 7 1.08 mg/kg wet 1.333 81 31-123 Source: 9010009-01 Prepared & Analyzed: 01/04/19 152 9.6 mg/kg dry 91.76 67.3 92 50-117 1.69 mg/kg dry 1.835 92 31-123 Source:9010009-01 Prepared &Analyzed: 01 /04/19 137 9.6 mg/kg dry 91.82 67.3 76 50-117 10 1.52 mg/kg dry 1.836 83 31-123 Sample Extraction Data Prep Method: 3546 Lab Number Batch Initial Final Date/Time 20 24 9010009-01 P9A0072 30.06 g 1 mL 01/04/19 12:05 9010009-02 P9A0072 30.06 g 1 mL 01/04/19 12:05 9010009-03 P9A0072 30.02 g 1 mL 01/04/19 12:05 9010009-04 P9A0072 30.03 g 1 mL 01/04/19 12:05 9010009-05 P9A0072 30.05 g 1 mL 01/04/19 12:05 9010009-06 P9A0072 30.07 g 1 mL 01/04/19 12:05 9010009-07 P9A0072 30.05 g 1 mL 01/04/19 12:05 9010009-08 P9A0072 30.09 g 1 mL 01/04/19 12:05 Prep Method: 5035 Lab Number Batch Initial Final Date/Time 9010009-01 P9A0090 3.96 g 5 mL 01/07/19 14:57 9010009-02 P9A0090 3.89 g 5 mL 01/07/19 14:57 9010009-03 P9A0090 6.47 g 5 mL 01/07/19 14:57 9010009-04 P9A0090 4.38 g 5 mL 01/07/19 14:57 9010009-05 P9A0090 5.46 g 5 mL 01/07/19 14:57 9010009-06 P9A0090 4.63 g 5 mL 01/07/19 14:57 9010009-07 P9A0090 3.99 g 5 mL 01/07/19 14:57 9010009-08 P9A0090 5.02 g 5 mL 01/07/19 14:57 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704/529-6364 - Toll Free Number: 1-800/529-6364 - Fax: 704/525-0409 Page 13 of 14 n is D N (7 u n CD m G) v N u T N ci r n N 0 r 7 (D d t7 m G O D 11 O (D O m N (/1 W O 2 CD m CA. v i _ _ cncnmm-0 Z pcn o 0 3 C a a a 3 �_ w J 3 r r CL CL m m cn n C:3 v C, !r S Mm O O m ❑❑ C y (n fn U F cn - -. - m �' r-+ s s S C'1 i z y 7 7 v y z -n S 0) C z� y O c c c O= >0 1O10 (` ' S 's S LS - O I SS y j C m m 3 1 n y F. U0, .� i - •� D x 1 ` Dy J xa v:, 1 I , I , n o C -1 t0 M 0 r 30 1`� t� m D m I�. RI Z 1m M O❑ c> a° Vn 00 1 _ 1 nm y K n D m m 0)i< _ �- _ 0 .r Z c g <r° O p d ic ADcmim m S ❑❑ v „ -I c ❑ mD m: p �ay3 .� G nz 0 Dm M. (n 7C iR ny f 3 ° 0 1 c'M m + �zFA cn C: C) N m N Cl d .m.. 0 x C- W r� G m m ill 1 Oo m lD y c d C 3 3 O n � m O Z .- = 7 m fA my L z m r N itl N .a ❑❑ y 3 m O 3 CD CD a O C c c = 0 CD m m N W, G o ❑� B w a �' r _ — T' n <mQ° d a To m z ccn N iA� w U) S O Z y ❑❑ W y A a rm r 11 D D S D A 3 W Z Z Zn �y m -1O to (D ❑ N O Z (D y 220 0 N O N O ID - •< 9 7 fo M :3OCL Z Z W N N ❑ A 1xi, AC r' i 1;M0 nAna W ❑ ❑� 5 mm ? i ;z (a yD 0>a� a co 7Q z52 mm,p ❑Y =C m < y fq(D �v m Z. (C) a y oa`ivaD <yd °Dj ❑ ❑ 0 y Zz 0l< n v 30O-CL ❑ r rvfl�, ID co r E r] y (�' z C) P Q w gr n m n = r D p CL yc _v am M m n n 0 0 .�. O0 m I z m v °v y m m p D (A 3 (A- p zm I DI JCD�. m 3- — 0 o f Q3 c3 c� o C C G z 5��- Z I m (n, p r CD m n seQ ° 3 . -. �_ n M A �A V 7 4 d oca N .�+ z - z d � m �. o� g♦♦♦may G1 No V♦ ?3 gym �_. 0�x IOU tr-q� T7 G P l- i V-ti -0 + xd m C - + rC 4O C:. N O cn CD 7 S (A0 fD 0 m C. °°C. w D V O p1 0) o w w ia° µ a< ° m c ° �• < m m 0) IID OD y' N 2 .Oe y 0 0 - - 0CL w D a=d f/r d n -i ° -1 W ^� m y 0 m 3 N Z r c W y m °`j. 'm o 0 m C 70 m JJ A � 1 r m 0 r m m r C) a m z o c 0 x m m v0�yi�D 0`�•3 1 r" O a a UM) 'm cn -mzD c?gay=Mm- o 5 o < J� 7 N = J (n <. -, �L O v mW in rn 0 2 m G o z O z D Paae 14 of 14 4k APPENDIX V Disposal Documents M RIVEI E, CCRPOR.ATION 1703 Vargrave Street Winston-Salem, NC 27107 Ph 336-725-5844 fax 336-725-6244 Tank Owner: D & R Properties of Charlotte,.LLC Site Address: 1128 Greenwood Cliff Charlotte, NC Description of Tanks: Tank Size of Tank Contents Number 1 500 Gallons #2 Fuel Oil Transporter: Evo Corporation EC Project #: 011909 Disposal Certification: Evo Corporation does hereby certify that the above named storage tank was transported to Foss Recycling, 3459 Thomasville Road, Winston-Salem, NC for proper disposal and recycling. Signature 1703 YnmYe Street Winston-Sakq, NC 27107 Ph 33B-726-W44 felt 336-725-6244 Evo Corporation does hereby certify that 200 gallons of nonhazardous contaminated water received on 1 /2/2019 from; Generator: D & R Properties of Charlotte, LLC Originating at: 1128 Greenwood Cliff Charlotte, NC EC Waste ID #: 011909 has been disposed of by Evo Corporation in a manner approved by the North Carolina Department of Environmental Quality. Signature Thomas W. Hammett n" r► CORPORATION Street,EVO i NON -HAZARDOUS, ... # Manifest No. 11245 GENERATOR INFORMATION I Generator: ' • Site Address: t City/State: Contact:, Zach D.aniel Gross Weight (lbs): Empty Weight (Ibs): Net Weight (Ibs): Quantity MATERIAL DESCRIPTION / QUANTITY / WEIGHT Material: A... / �r tot Contaminant: Tons Drums Pails Sacs Yards Other: TRANSPORTER INFORMATION Transporter: Phone: Truck #: Contact: __ :m As the transporter, I certify that the materials described above being shipped under this non -hazardous materials manifest are properly classified, packaged, labeled, secured and are in proper condition for transport in commerce under the applicable regulations governing transportation, and I hereby receive this material for delivery to the facility designate. Driver Signature: „� f Date: FACILITY INFORMATION �7 , breet } t 1 :' • 'I' " t t NC Evo Project #: 11209 Phone: Contact: I certify that the carrier has delivered the materials described above to this facility, and I hereby accept this material for treatment and/X gsposal in,a m�apuqJbat has been authorized by the State of North Carolina. Facilitv Siqnature: Date: / / a Evo Corporation, 2008 Beverly, Trudy From: Beverly, Trudy Sent: Wednesday, June 19, 2019 3:44 PM To: Tom Hassett Subject: RE: [External] RE: Pdf Copies of Reports - 1128 Greenwood Cliff, Charlotte and 1127 Harding Place, Charlotte Great. Thanks for the update. Trudy DE 'V iIRTH CH�AR LINA Depa—Mienl,um mental Many\ Tn* 'tea Lam. UST Sva6u, Momaylle RgJa d Offim (7 235,2182 (O mo-SOMMMMirm Email correspondences to arxJ from this address is subject to the North Carolina Public records Law and may be disclosed to third parties. From: Tom Hassett [mailto:thassett@geosciencegroup.com] Sent: Wednesday, June 19, 2019 3:40 PM To: Beverly, Trudy <trudy.beverly@ncdenr.gov> Subject: RE: [External] RE: Pdf Copies of Reports - 1128 Greenwood Cliff, Charlotte and 1127 Harding Place, Charlotte External email. Do not click links or open attachments unless you verify. Send all suspicious email as an tachment to report.spam@nc.gov No problem. As a heads up, we've excavated impacted soils at these two sites. I should have those reports out before the end of this week. Thomas C. Hassett, P.E. Senior Engineer GEOSCIENCE GROUP, INC. 500-K Clanton Road Charlotte, NC 28217 (704) 941-2262 - Office (704) 525-2051 - Fax (704) 506-5446 - Mobile From: Beverly, Trudy <trudy.beverly@ncdenr.gov> Sent: Wednesday, June 19, 2019 3:34 PM To: Tom Hassett <thassett@geosciencegroup.com> Subject: RE: [External] RE: Pdf Copies of Reports - 1128 Greenwood Cliff, Charlotte and 1127 Harding Place, Charlotte Received. Thanks Tom! Trudy itc D EC1101 NORTH GAROLIhiA Department of Emimnmental Quality I Lam. '64q&3;;of A'M4PMM varsel YouluOI= (7" 23S,21i2 (OR* TFudy.1wfrhditda M-V Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Tom Hassett [mailto:thassett@geosciencegroup.com] Sent: Wednesday, June 19, 2019 3:20 PM To: Beverly, Trudy <trudy.beverly@ncdenr.gov> Subject: [External] RE: Pdf Copies of Reports - 1128 Greenwood Cliff, Charlotte and 1127 Harding Place, Charlotte • External email. Do not click links or open attachments unless you verify. Send all suspicious email as an chment to report.spam@nc.gov Trudy, Here are copies of the reports. Thanks for sending the submittal info. Thomas C. Hassett, P.E. Senior Engineer GEOSCIENCE GROUP, INC. 500-K Clanton Road Charlotte, NC 28217 (704) 941-2262 - Office (704) 525-2051 - Fax (704) 506-5446 - Mobile From: Beverly, Trudy <trudy.beverly@ncdenr.gov> Sent: Tuesday, June 18, 2019 1:42 PM To: Tom Hassett <thassett@geosciencegroup.com> Subject: Pdf Copies of Reports - 1128 Greenwood Cliff, Charlotte and 1127 Harding Place, Charlotte Hey Tom, I am reviewing the 1128 Greenwood Cliff, Charlotte and 1127 Harding Place, Charlotte Initial Action Abatement reports. Neither report included a cd with a pdf copy of the report. Please email me a pdf copy of each report. Future UST submittals should be in accordance with the following policies. Document Submittal & UST File Names for Laserfiche Policies: https://files.nc. gov/ncdeg/W aste%20Management/D W M/U ST/Corrective%2OAction/Electronic%2ODocument%2OSubmittal %20Memo%20Update.pdf his:Hfiles.nc.gov/ncdeq/WasteD/o20Management/DWMiUST/CorrectiveD/`2OAction/USTD/`20fileD/o20names%20for%2OLasfiles.nc.gov/ncdeq/Waste%20Management/DWMiUST/Corrective%2OAction/UST%20file%20names%20for%2OLas erfiche.docx Thank you for your assistance, Trudy rp* , Lam. D�-.E '"4 "m of `v A&wpmm 1W 10, XT & Deparlment of Environmenlal pvahty Lmail correspondence to and from this address is subject to the North Carolina Public Reccxds Law arKJ may be disclosed to third parties. Office Mailing Address: 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Branch's Underground Storage Tanks Website Address: h!Ws:Hdeq.nc.gov/about/divisions/waste-management/ust Branch's Above Ground Storage Tanks Website Address: https://deq.nc.,gov/about/divisions/waste-management/ust/ast- program INTERACTIVE MAPS WITH DWM SITES AND PERMITTED FACILITIES: httns://dea.nc. gov/about/divi si ons/waste-management/waste-management-rules-data/waste-management-gis-mans File Review Procedures: https://deq.nc. gov/about/divi sions/waste-management/ust/file-review-procedures#mooresville-regional-office ONLINE ACCESS TO UST SECTION DOCUMENTS (Laserfiche): httDs:Hedocs.dea.nc. rLov/WasteManaLyement/Search.asDx Document Submittal & UST File Names for Laserfiche Policies: https://files.nc. gov/ncdeq/Waste%20Management/DWM/UST/Corrective%20Action/Electronic%20Document%20Submittal %20Memo%20Update.pdf hllps:Hfiles.nc.gov/ncdeq/Waste%20Mana,gement/DWM/ JST/Corrective%20Action/UST%20file%20names%20for%20Las erfiche.docx