Loading...
HomeMy WebLinkAbout6013_GreenwayNorthMeckCDLF_20190920_LFGMonReport_FID1358407)hfFt tt�l`1C1' ;: ❑Paper Report -]Electronic Data -Email CD data loaded: Yes / No oc/Event #: NC DENR Envilronmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 1 2-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B ,surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit;' NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information I Name of entity submitting data (laboratory, consultant, facility owner): Greenway Waste Solutions of North Meck, LLC Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Brandt R. Kayser, PG Phone: 914-844-7048 E-mail: brandt@griffinbros.com NC Landfill Rule;: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or',1600)1 October 20-24, 2006) IN hrto Mecklenburg C&D Landfill i(Infill) 15300 Holbrooks Road, Huntersville, NC 60-13 .0590 September 17,2019 Environmental Status: (Check all that apply) E] Initial/Background Monitoring ❑X Detection Monitoring Assessment Monitoring' ! IF Corrective Action T e of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells FX Methane gas monitoring data' Groundwater monitoring data from private water supply wells Corrective action data (specify) Leachate monitoring data ❑ _L Surface water monitoring data Other(specify) Notification attached? [� No. No groundwater or surface water standards were exceeded. �J Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NG Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. ❑X Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification y g p To the best of m knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Brandt R. Kayser, PG Environmental Compliance Officer 914-844-7048 Facility Repr entative Name (Print) Title (Area Code) Telephone Number w __ Affix NC Licen 7i j at sed/ Professional Geologist Seal r c Signature Date B 19505 Liverpool Parkway, Cornelius; NC 28031 ®9+� Tea^ �I 0 �d4i, Facility Representative Address ®(i�r' 6.L c Not Applicable ®� � t. NC PE Firm License Number (if applicable effective May 1, 2009) 6- • Revised 6/2009 `a A. , °b LAG a�d9®oea9 �� METHANE MONITORING FORM Landfill Name: North Mecklenburg Landfill - INFILL Sampler name: M. Ginther Barometric Pressure: 29.33 in Hg Temperature: 75° F Weather conditions: Sunny Instrument: Landtec GEM 5000/G505813 Date: June 4, 2019 Location Time CH4 CH4 LEL 02 CO2 MMW-1 1000 0.0 0.0 14.3 5.1 MMW-2 1035 0.0 0.0 20.6 0.9 MMW-3 1040 24.9 498 8.9 23.1 MMW-4 1045 0.0 0.0 17.1 4.0 MMW-5 1055 0.0 0.0 20.9 0.7 MMW-6 1115 0.0 0.0 17.5 4.1 MMW-7 1125 0.0 0.0 19.0 2.3 MMW-8 1130 0.0 0.0 21.0 0.3 MMW-9 1140 0.0 0.0 19.5 4.9 MMW-10 1150 0.0 0.0 11.3 13.3 MMW-11 1200 9.0 180 14.6 4.8 Scale House 1210 0.0 0.0 21.9 0.1 Comments: CH4 LEL is a calculated value based on 5% CH4 = 100% CH4 LEL NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: IVA L F r,'—p" '( t ' Permit Number: 01 _0 Sampling Date: NC Landfill Rule (.0500 or. 1600): Sample Collector Name &Position: ✓����.�� ��r'��cw�� ltii�a��� Gas Meter Type & Serial Number: ,3 000 t Gas Meter Calibration Date: f c; Field Calibration Date & Time: 0— Field Calibration Gas Type (15115 or 35/50): Field Calibration Gas Canister Expiration Date: Gas Meter Pump Rate: Ambient Air Temperature: -�-rBarometric Pressure iris or mmHg): � ?< Weather• Conditions: Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or Sample Time LFG Well ID Tube Time of Pumped Initial Stabilized % CH4 oho 02 % CO2 % H2S* � •� k i NOTES Purge Day (sec) % LEL % LEL volume (volume) (volume) e � -sre B,yRs' "5 ,.,4• 9 l l ,.i` �•, ;+" y 14 'Al n"-0 = \ r 77 .p,�, ] p ®tee 461 C? mow..®p,,�.'„ a`.t, m �� 5—. r �„�a. ge.� $' � G �` , g bw 4H .m+ �,A Vd . �•",.'�9 .9 r a 'C. �„,/}, . uM1 F °„VL NOTE_ lfneeded. attach additional data forms to include additional LFG monitoring data locations for the facility ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1% by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. SIGNATURE TITLE Revised — March 6, 2017 *, ;, �, � �� ���• * .f •�l •� � , ', �_ LEGEND PROPERTY LINE �� �.. �•• ,'� EXISTING STREAM +- s � _ CLOSED PHASE I AREA METHANE NORTH !� t MONITORING WELL • :�� INFILL AREA +�n METHANE MONITORING WELL ' � '� LANDFILL POINT OF COMPLIANCE - Mw-4a GROUNDWATER MONITORING WELL ,. MW-5 LANDFILL REVIEW BOUNDARY • GROUNDWATER MONITORING WELL SURFACE WATER SAMPLING = sw-� LOCATION (D sw-7 NEW SURFACE WATER SAMPLING � + LOCATION (APPROX) (i) REFERENCE TO INFILL AREA yR' ' i o*- t f i . T +. d ; + - + ' MW-9D(i) 1 y F ■ *. x `4 . ` + 4y ' • Y� S't w FCLOSED PHASE I AREA MW-6Dl-- MW-9 - .D :� 1 ` �.. • ' t [1i i i GREENWAY WASTE SOLUTIONS OF A AV AV NORTH MECK, LCC Civil & Environmental Consultants, Inc. NORTH MECKLENBURG LANDFILL 1900 Center Park Drive - Suite A - Charlotte, NC 28217 HUNTERSVILLE, NORTH CAROLINA REFERENCE Ph: 980.237.0373 - Fax: 980.237.0372 WATER QUALITY MONITORING LOCATION MAP SCALE IN FEET www.cecinc.com 1. AERIAL IMAGERY TAKEN FROM GOOGLE EARTH PRO. DRAWN BY: JKS/PAB CHECKED BY: EHS APPROVED BY: EHS ATTACHMENT: DATED OCTOBER 8, 2016 0 400 800 DATE: FEBRUARY 2018 1 DWG SCALE: 1" = 400' PROJECT NO: 111-370.0001 1