Loading...
HomeMy WebLinkAboutMO-8166_36757_G_NORR_20190903_Notice of Regulatory RequirementsROY COOPER Governor MICHAEL S. REGAN Secretary MICHAEL SCOTT Director Monroe Oil Company, Inc. Attn: Olin Furr P.O. Box 1109 Monroe, NC 28111-1109 Dear Mr. Furr: NORTH CAROLINA Environmental Quality September 3, 2019 Re: Notice of Regulatory Requirements 15A NCAC 2L .0407(b) Risk -based Assessment and Corrective Action for Petroleum Underground Storage Tanks Amoco #9 7810 Lyles Lane, Concord Cabarrus County Incident Number: 36757 Risk Classification: High The UST Section, Division of Waste Management (DWM), Mooresville Regional Office (MRO) received the July 2019 Groundwater Monitoring Report on August 1, 2019. The Report is incomplete. Monitoring reports should be submitted in accordance with the most recent revised monitoring report template "Corrective Action Monitoring Report" (Task 6.105). See the 4/18/2017 section of the following link for revised monitoring report templates https://deq.nc.gov/about/divisions/waste- management/ust/whats-new#2017. Monitoring Reports requirements are defined in Template 9A. Reports failing to be submitted in accordance with the most recent template requirements are considered incomplete. Please note the following monitoring report requirements: • Site History and Characterization — Provide information on owners and occupants of property within or adjacent to area containing contamination or the area where contamination is expected to migrate and describe land use. Refer to tables (Use Table B-6, Property Owners/Occupants; and Table B-10, Land Use) and refer to land use map. Present information on receptors/potential receptors. Refer to table (Use Table B-5, Public and Private Water Supply Well and other Receptor Information;) and to potential receptor map that clearly identifies water supply wells (municipal or North Carolina Department of Environmental Quality I Division of Waste Management Mooresville Regional Office 1 610 East Center Avenue, Suite 301 1 Mooresville, North Carolina 28115 704.663.1699 public/private wells, etc.) and other potential receptors (surface water bodies, basements, utilities, wellhead protection areas, etc.) within 1500' of the source of the release. Describe current proximity of plumes to potential receptors. Present current information on the provision of bottled water or on the connection of properties to municipal water. Add the groundwater flow direction to the map A site map* and cross -sections illustrating the UST system(s), drawn to scale, should show: Buildings and property boundaries; Streets, roads, highways (labeled); Underground utilities, such as sewer lines and other conduits; basements; and vaults; Monitoring wells, water supply wells, surface water bodies; Location and orientation of current and former UST(s), pumps, product lines, sumps, etc.; Length, diameter and volume of current and former UST(s); Type of material(s) stored in UST(s) (currently and formerly); and North arrow and scale. Map(s)* and geological cross -sections, drawn to scale, depicting all soil analytical results obtained to date, to include: Description of soil and bedrock lithology (as determined by investigation to date); Location and orientation of UST(s)/AST(s), pumps, piping, sumps, etc. (current and former), any known spills, and (if applicable) illustrating any excavation dimensions or remediation system components; Soil sample identification (unique letter and/or numerical code), location, and depth; Soil sample analytical results; Date soil sample collected; Final limits of each stage of excavation for each excavation on site; A general plan depicting the footprint of any soil remediation system installed on site; and Two geological cross -sections, drawn across the contaminated area and intersecting at right angles, showing the vertical distribution of the contaminants in the unsaturated zone. (Indicate vertical and horizontal scale, orientation of each section, location of water table, soil types and lithology, all borings and sample locations represented by the sections, and soil analytical results for each represented sample, and show sections as labeled lines on the map.) Map, drawn to scale, depicting the groundwater and surface water analytical results, should include: Location and orientation of UST(s), pumps, piping, sumps, etc. (current and former); Groundwater sample identification (unique letter and/or numerical code referencing monitoring or water supply well) and location; Date of sampling; Surface water sample identification (unique letter and/or numerical code) and location; and Groundwater and surface water sample analytical results. Please provide the materials needed to complete the Monitoring report within sixty (60) days of the date of this letter. Include text and/or figures for support. Please note that sampling and correction action must be conducted in accordance with the Guidelines for Assessment and Corrective Action for UST Releases. Failure to comply in the manner and time specified may result in the assessment of civil penalties and/or the use of the other enforcement mechanisms. If you have any questions regarding trust fund eligibility or reimbursement from the Commercial or Noncommercial Leaking Petroleum Underground Storage Tank Cleanup Funds, please contact the UST Section Trust Fund Branch at (919) 707-8171. If you have any questions regarding the actions that must D 1E North Carolina Department of Environmental Quality I Division of Waste Management Mooresville Regional Office 1 610 East Center Avenue, Suite 301 1 Mooresville, North Carolina 28115 704.663.1699 be taken or the rules mentioned in this letter, please contact me by email at Trudy.Beverlyykncdenr. og_v or telephone at (704) 235-2182. Sincerely, � 14, ;11w+ Trudy Beverly, L.G. Hydrogeologist Mooresville Regional Office UST Section, Division of Waste Management, NCDEQ cc: Suzie Gibson, EMC Insurance Company, P.O. Box 621210, Charlotte, NC 28262-0120 Joe Beaman & Bill Frederick, Highlands Environmental Solutions, Inc., 8410-D Falls of Neuse Road, Raleigh, NC 27615 (via email) Mike Downs, Cabarrus County Manager (via email) David Troutman, Cabarrus County Health Department (via email) pannwY*�` n�ia.nama aal� North Carolina Department of Environmental Quality I Division of Waste Management Mooresville Regional Office 1 610 East Center Avenue, Suite 301 1 Mooresville, North Carolina 28115 704.663.1644 Beverly, Trudy From: Beverly, Trudy Sent: Tuesday, September 3, 2019 3:48 PM To: William Frederick; Joe Beaman; Mike Downs; David Troutman Subject: Amoco #9 - Incident #36757 — Notice of Regulatory Requirements Attachments: MO-8166_36757_G_NORR_20190903_Notice of Regulatory Requirements.pdf Please see the attached Notice of Regulatory Requirements letter for Amoco #9 (UST Incident #36757) located at 7810 Lyles Lane in Concord, Cabarrus County. Trudy Trudy Beverly, L.G. D- � I E Q, Hydrogeologist, Division of Waste Management North Carolina Department of Environmental Quality UST Section, Mooresville Regional Office 704.235.2182 (Office) Trudy. B everlykncdenr. gov Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Office Mailing Address: 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Branch's Underground Storage Tanks Website Address: ht_pt s://deg.nc.gov/about/divisions/waste-management/ust Branch's Above Ground Storage Tanks Website Address: httns://deg.nc.gov/about/divisions/waste-management/ust/ast-program INTERACTIVE MAPS WITH DWM SITES AND PERMITTED FACILITIES: httns://dca.nc.gov/about divisions/wastc-managcmcnUwaste-management-rules-data/waste-manaeement-gis-mans File Review Procedures: httns://dea.nc.gov/about/divisions/wastc-mana2cmcnt/tist/file-review-nrocedures#mooresville-regional-office ONLINE ACCESS TO UST SECTION DOCUMENTS (Laserfiche): hopsedocs.deq.nc. gov/WasteManagement/Search.aspxx Document Submittal & UST File Names for Laserfiche Policies: hops://files.nc. gov/ncdeq/W aste%2OMana,gement/D WM/UST/Corrective%2OAction/Electronic%2ODocument%2OSubmittal%2OMemo%2OUpdate.pdf https:Hfiles.nc. gov/ncdeq/Waste%2OManagement/DViM/UST/Corrective%2OAction/UST%20file%20namcs%20for%2OLaserfiche.docx