Loading...
HomeMy WebLinkAbout5803_INSP_20190819NORTH CARnLINAD_E Q�/�� FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section UNIT TYPE: Lined LCID YW Transfer X Compost SLAS COUNTY: MADISON MSWLF PERMIT NO.: 58-03 Closed HHW X White X Incin T&F X FIRM MSWLF goods FILE TYPE: COMPLIANCE CDLF X Tire T&F/ X Tire Industrial DEMO SDTF Collection Monofill Landfill Date of Site Inspection: 8/19/2019 Date of Last Inspection: 7/10/2018 FACILITY NAME AND ADDRESS: Madison County Solid Waste Management Facility 271 Craig Rudisill Road Marshall, NC 28753 GPS COORDINATES: Lat: 35.808860' Long:-82.716745' FACILITY CONTACT NAME, PHONE NUMBER, & EMAIL: Name: Mr. Sam Lunsford Telephone: 828-649-2311 Email address: slunsfordkmadisoncountync.gov FACILITY CONTACT ADDRESS: Same as above. PARTICIPANTS: Kris Riddle, Environmental Senior Specialist, Solid Waste Section (Section) Mark Tipton, Operator, Madison County Solid Waste Department James Ensley, Operator, Madison County Solid Waste Department Rebecca Shook, Scale House/Administration, Madison County Solid Waste Department Megan Gosnell, Scale House/Administration, Madison County Solid Waste Department STATUS OF PERMIT: Active. Permit to Operate issued July 11, 2016 (DIN 26263) includes: 5803-CDLF-1995 Madison County Construction and Demolition (C&D) Unit 2; 5803T-Transfer-2002 Madison County Transfer Station; & 5803-HHW Madison County Solid Waste Household Hazardous Waste (HHW). PURPOSE OF SITE VISIT: Comprehensive Site Inspection. STATUS OF PAST NOTED VIOLATIONS: None. OBSERVED VIOLATIONS: 1. 15A NCAC 02C .0108(o) states: "Each non -water supply well shall have permanently affixed an identification plate. The identification plate shall be constructed of a durable, waterproof, rustproof metal or other material approved by the Department as equivalent and shall contain the following information: (1) well contractor name and certification number; (2) date well completed; (3) total depth of well; (4) a warning that the well is not for water supply and that the groundwater may contain hazardous materials; Page 1 of 8 FACILITY COMPLIANCE INSPECTION REPORT D_E Q�� Division of Waste Management NORTH CAROLINA W,Ift Solid Waste Section (5) depth(s) to the top(s) and bottom(s) of the screen(s); and (6) the well identification number or name assigned by the well owner. " As stated in the previous facility compliance inspection report, dated July 10, 2018, identification plates had been re- installed/maintained on most environmental monitoring wells at the facility (after being painted over), but the identification plates did not contain all the required information (photos #1 & #2). During this inspection it was observed that identification plates had fallen off and were not installed or permanently affixed on environmental monitoring wells at the facility. Additionally, observed identification plates on environmental monitoring wells at the facility did not contain all of the required information (see Tables #1 & #2 below). Table 1: Groundwater Monitoring Wells - Groundwater Monitoring Well #1 Identification plate not installed. Well not locked. Groundwater Monitoring Well #2 Identification plate not installed. Well locked. Groundwater Monitoring Well #3 Identification plate installed. Information complete but barely legible. Well locked. Groundwater Monitoring Well #4 Identification plate installed. Information incomplete. Well locked. Groundwater Monitoring Well #5 Identification plate installed. Information incomplete. Well locked. Groundwater Monitoring Well #6R Flush mounted well. No visible identification plate. Groundwater Monitoring Well #7R Identification plate installed. Information incomplete. Well locked. Groundwater Monitoring Well #8 Identification plate installed. Information incomplete. Well locked. Groundwater Monitoring Well #9 Identification plate not installed. Well locked. Table 2: Landfill Gas (LFG) Monitoring Wells - Landfill Gas Well #1 Identification plate installed. Information incomplete. Well locked. Landfill Gas Well #2 Identification plate installed. Information incomplete. Well locked. Landfill Gas Well #3 Identification plate not installed. Well locked. Landfill Gas Well #4 Identification plate installed. Information incomplete. Well locked. Landfill Gas Well #5 Identification plate installed. Information incomplete. Well locked. Landfill Gas Well #6 Identification plate not installed. Well locked. To achieve compliance, Madison County Solid Waste Management Facility must affix a permanent identification plate to the outer steel casing of all facility environmental monitoring wells as specified in 15A NCAC 02C .0108(o). Post -inspection, the Section contacted Madison County Solid Waste Director, Mr. Sam Lunsford. Mr. Lunsford stated the facility had acquired identification plates for the facility environmental monitoring wells and conducted preliminary maintenance work (collection of historic well installation information for identification plates) to gain compliance with 15A NCAC 02C .0108(o). * For additional information, please see the Section's March 23, 2017, Memorandum titled "Permanent and Temporary Groundwater and Landfill Gas Monitoring Wells, Piezometers, and Probes", which can be located at the following direct document link: httns:Hfiles.nc. gov/ncdea/Waste%2OManaizement/DWM/S W/Field%200nerations/Environmental%2OMonitorina/MW Maint_Requirements.pdf Page 2 of 8 FACILITY COMPLIANCE INSPECTION REPORT D_E Q�� Division of Waste Management NORTH CARnLINA Solid Waste Section Al"W7 WARNING GROUNDWATER • MONITORING WELL ISTAATION NO. DATE: _2X DEPTH FT. WarEw CASING PTH: —w DIA. IN. MOglioglNG WELL'4 SCREEN - TO— SAND: TO —'- — BENTO TE: TO _ - — GROAT TO CAUTION NOT POTABLE WATER 1. Groundwater Monitoring Well #7R. Note: well labeled but incomplete information on identification plate. Identification plate not permanently affixed. 2. LFG Monitoring Well #5 (a.k.a. Gas Probe-5). Note: well labeled but incomplete information on identification plate. Identification plate not permanently affixed. The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. ADDITIONAL COMMENTS 1. On -site August 19, 2019, to review facility records/certifications, observe the convenience center area, observe facility environmental monitoring wells, and inspect the Transfer Station, Scrap Tire/Electronics area, White Goods/Scrap Metal area, Household Hazardous Waste (HHW) area, and the active Construction and Demolition (C&D) Landfill Unit 2. Participants from the facility included Mark Tipton, James Ensley, Rebecca Shook, and Megan Gosnell. 2. Post -inspection, additional research conducted and concluded on August 26, 2019. General/Records Review: 3. The facility's current operating hours are: Monday — Friday: 8:00 a.m. — 4:30 p.m.; and Saturday: 8:00 a.m. — 12:00 p.m. 4. Entrance and access roads were maintained at the facility. Dust suppression efforts appeared to be sufficient during this inspection. Signage was maintained at the facility (photo #3). Page 3 of 8 NORTH CAR()LINAD_E Q�� OepaNnent of Envieonmenbl Wel� FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section 3.Signage at facility entrance. 5. The current Permit to Operate (PTO) and Operations Plan were available for review. 6. Training certifications were reviewed on -site and are listed below: Operator Training Certification Expiration Date James Ensley Transfer Station Operations 6/2023 Lee Mathis Transfer Station Operations 6/2022 James Norton Transfer Station Operations 6/2022 Luther Roberts Transfer Station Operations 6/2022 Operator Training Certification Expiration Date James Ensley Landfill Operator 8/2022 Lee Mathis Landfill Operator 6/2022 Operator Training Certification Expiration Date Sam Lunsford Landfill Manager 12/2022 Mark Tipton Landfill Manager 12/2022 7. Transfer Station municipal solid waste (MSW) is currently transported to the Lakeway Recycling and Sanitation Landfill Facility in Lowland, TN (TN DEC #SNL32-0280) for disposal. Monthly tonnage records for waste received at the facility were reviewed from July 2018 through July 2019. Per these records, in July 2019 the facility accepted, on average, approximately 43 tons -per -day of MSW, and approximately 4.6 tons -per -day of C&D waste. 8. Transfer station and C&D landfill waste screening records were reviewed from 3/25/19 through 8/13/19. As noted, any observed unacceptable wastes were removed from the waste stream, documented, and disposed of properly. Facility personnel currently take photographs in conjunction with the waste screening reports. As observed on -site, the facility is doing an excellent job of waste screening and waste screening documentation procedures. Page 4 of 8 FACILITY COMPLIANCE INSPECTION REPORT D_E Q�� Division of Waste Management NORTH CAROLINA o"'­ t0E ! 'm"""°"""' Solid Waste Section 9. The site -wide Groundwater, Surface Water, and Leachate monitoring network currently consists of nine (9) groundwater monitoring well locations, two (2) surface water sampling locations, and one (1) leachate collection point that function to monitor both the active C&D and closed C&D and MSW landfill facilities on -site. Groundwater, surface water, and leachate monitoring reports for the facility dated June 2019 (for Spring 2019 sampling event) and February 2019 (for Fall 2018 sampling event) were available for review. As required, continue to monitor all groundwater, surface water, and leachate sampling locations and submit monitoring reports to the Section in a timely manner. 10. The site -wide LFG monitoring system includes six (6) wells and two (2) structures (2 measurements in each structure) and serves to function as a methane monitoring system that encompasses both the active C&D and closed C&D and MSW landfill facilities on -site. Quarterly LFG monitoring reports dated 5/8/19, 2/7/19, 11/16/18, and 8/16/18 were available for review. No LFG exceedances for the facility were noted in the monitoring reports. 11. Asbestos records for the facility were available for review. Per facility records, small quantities of asbestos were disposed at the active C&D Landfill Unit 2 in March and April 2019. The facility was notified prior to receipt of the asbestos and all asbestos was properly disposed per the approved Operations Plan. 12. The facility accepts waste oil, used oil filters, and antifreeze in a designated area located north of the active C&D Landfill Unit 2. These materials are kept under cover. The facility currently contracts with Holston Environmental Services, Inc. located in Waynesville, NC, for waste oil, used oil filters, and antifreeze removal/processing. Per facility records, Holston Environmental Services, Inc. removes material(s) from the facility approximately once per month. 13. The facility accepts used cooking oil which is stored in a containerized vessel located near the maintenance/recycling building. No solid waste issues were observed in this area. The facility currently contracts with Blue Ridge Biofuels located in Asheville, NC, for used cooking oil removal/processing on an as -needed basis. 14. Household recyclables (glass, mixed paper, cardboard, and plastics) are accepted at the facility in roll -off containers located just north of the facility office. Glass recyclables are collected on an as -needed basis by Strategic Materials, Inc. located in Wilson, NC. Mixed paper, cardboard, and plastic recyclables are collected on an as -needed basis by American Recycling of WNC, located in Candler, NC. This area was well maintained and an attendant was on -duty to assist customers. No solid waste issues were observed in this area. 15. Scrap tires and electronics are accepted at the maintenance/recycling building located northwest of the facility office. These materials are kept under cover until they are loaded into a semi -trailer for removal/processing. No solid waste issues were observed in this area. The facility currently contracts with Electronic Recyclers International, Inc. located in Badin, NC, for electronics removal/processing on an as -needed basis. The facility currently contracts with US Tire Recycling LP, located in Concord, NC, for tire removal/processing on an as -needed basis. Scrap tire disposal records were reviewed from l/1/19 to 8/8/19. Scrap tire disposal records were well organized and no issues were noted. 16. White goods and scrap metals are accepted at the facility in a designated area located northwest of the active C&D Landfill Unit 2. (As a convenience for County residents, some scrap metals are accepted in a container at the convenience area located north of the facility office. The scrap metal is transported by facility personnel to the white goods and scrap metals area as needed.) Chlorofluorocarbon (CFC) refrigerants (CFC R-12, R-22, and R-134) are removed by facility personnel on -site. The facility currently contracts with Biltmore Iron and Metal Co. located in Asheville, NC, for white goods and scrap metals removal/processing. No solid waste issues were noted in this area. 17. The Mulching and Grinding Treatment and Processing area at the facility was not active during this inspection. As discussed with site personnel, the facility is currently directing customers with this type of waste material to Riverside Stump Dump, IV (YWN-11-034) for disposal/processing. 18. As self -reported by the facility on July 11, 2019, after an extreme storm event, the historic sediment basin/impoundment on the northern end of the facility (between Surface Water Sampling Location #2 and Groundwater Page 5 of 8 FACILITY COMPLIANCE INSPECTION REPORT D_E Q�� Division of Waste Management NORTH CAROLINA o"' t0E­!�'m"""°"""' Solid Waste Section Monitoring Well #1) was breached. As observed during this inspection, Groundwater Monitoring Well #1 appeared to be unaffected by this event. As discussed at length on -site, continue to maintain this area per the Division of Energy, Mineral, and Land Resources (DEMLR) and the Division of Water Resources (DWR) requirements. Household Hazardous Waste (HHW) Area: 19. The HHW area was locked/access controlled at the time of inspection. HHW wastes were properly stored in a labeled, segregated manner. Paint in the used paint shed was segregated into oil -based and water -based paint areas. The facility currently holds HHW collection events four (4) times per year in April, May, September, and October. Pesticides received during site HHW collection events are collected from the facility by the NC Department of Agriculture and Consumer Services Pesticide Disposal Assistance Program as needed. All HHW records reviewed for this facility appeared to be in order. The Section noted the HHW area at the facility was neat and organized. The Section also recognized that facility employee, Rebecca Shook, had been instrumental in consistently facilitating HHW collection events for the residents of Madison County. Also noted: facility employees Sam Lunsford, Rebecca Shook, Mark Tipton, James Ensley, and James Norton all attended a 3RC HHW Refresher Course since the previous inspection. Continue to maintain the HHW area at the facility as necessary. Transfer Station: 20. The facility currently contracts with Asheville Fire and Safety Co. for fire extinguisher maintenance at the facility. Continue to maintain fire extinguishing equipment at the facility as necessary. 21. As observed during this inspection, repairs to small holes/tears in the interior and exterior transfer station walls had occurred since the previous inspection. As discussed with Mr. Lunsford post -inspection, routine maintenance of the interior transfer station walls (pressure washing to remove dust/grime) is scheduled to occur in Fall 2019. Continue to maintain the interior and exterior walls of the transfer station as necessary (photo #4). 4. Southwestern view of the transfer station building. 22. No unacceptable wastes were observed at this facility. Continue waste screening efforts per the approved Operations Plan. 23. The transfer station tipping floor and transfer trailer loading area (receiving bay) appeared to be maintained during this inspection. As discussed with Mr. Lunsford post -inspection, in addition to daily washing, the tipping floor was recently maintained (pressure washed) as part of routine facility maintenance. As discussed post -inspection, continue to maintain the tipping floor and transfer trailer loading area as necessary. 24. The transfer trailer storage area located southeast of the transfer station appeared to be maintained during this inspection. 25. The leachate collection system grates and trenches were maintained during this inspection. The leachate collection system drains to an approximately 5,000-gallon on -site storage tank. The facility currently contracts with Able Septic Tank Service located in Asheville, NC, for leachate/wastewater removal. Able Septic Tank Service hauls the wastewater Page 6 of 8 FACILITY COMPLIANCE INSPECTION REPORT D_E Q�� Division of Waste Management NORTH CAROLINA °°°°­t0` !Mm"" lW,Ift Solid Waste Section to the Town of Marshall WWTP. Records reveal the tank was last pumped on 4/23/19. Continue to monitor and maintain the leachate collection system at the facility as necessary. 26. Minimal windblown litter was observed at this facility. Continue daily maintenance efforts to remove and properly dispose of windblown litter from this facility. Active C&D Landfill Unit 2: 27. No unacceptable wastes were observed at this facility. Continue waste screening efforts per the approved Operations Plan. 28. As discussed on -site, access to the working face of the active C&D Landfill Unit 2 has been maintained/re-worked since the previous inspection (photo #5). Per facility personnel, maintenance efforts have allowed for safer access to the working face for residential and commercial customers. Additionally, facility personnel currently accompany each customer to the active C&D Landfill Unit 2 working face to ensure proper disposal at this unit (as well as for additional waste screening). As discussed, continue to maintain the working face of the active C&D Landfill Unit 2 to as small an area as possible (photo #6). 5. Southern view of active C&D Landfill Unit 2 access. 6. Southern view of active C&D Landfill Unit 2 working face. 29. Continue to maintain Edge -of -Waste (EOW) markers around the active C&D Landfill Unit 2 as necessary. 30. As discussed during this inspection, continue to maintain cover material at this unit. As the approved Operations Plan states in Section 2.1, "Madison County shall cover the disposed waste with six (6) inches of earthen material at least once a week or when the working area reaches one-half acre in size, or more often as necessitated by the nature of the waste to control disease vectors, fires, odors, blowing litter, water infiltration and scavenging". 31. Continue to maintain storm water/surface water control(s) for the active C&D Landfill Unit 2 unit as necessary. 32. Windblown litter was not observed at this unit. Continue daily maintenance efforts to remove and properly dispose of windblown litter from the active C&D Landfill Unit 2 as necessary. 33. As discussed, continue seasonal vegetative mowing efforts for the active C&D Landfill Unit 2 as necessary. 34. Continue to maintain all erosion control measures at the active C&D Landfill Unit 2 as necessary. 35. All photographs taken by Kris Riddle on August 19, 2019. Page 7 of 8 FACILITY COMPLIANCE INSPECTION REPORT D_E Q�� Division of Waste Management NORTH CAROLINA o"'— t0—! 'm"""°"""' Solid Waste Section Please contact me if you have any questions or concerns regarding this inspection report. Digitally signed by Kris Riddle Kris Riddle Date: 2019.08.27 12:56:15 -04'00' Phone: 828-296-4705 Kris Riddle, Environmental Senior Specialist Division of Waste Management, NC DEQ Regional Representative Sent to Sam Lunsford, on X Email Hand delivery US Mail Certified No. L_A August 27, 2019, via: E-Copies: Deb Aja, Western District Supervisor - Solid Waste Section Page 8 of 8