Loading...
HomeMy WebLinkAbout3420_OmnisourceIndusLF_4thComments_SlopeRepairPlan_FID1324599_201907221 Chao, Ming-tai From:Chao, Ming-tai Sent:Monday, July 22, 2019 11:31 AM To:Winegar, James Cc:Stanley, Sherri; Davis, Amy; Heim, Susan A; Kemppinen, Hannu Subject:Comments on Omnisource Kernersville Slope Repair SW # 34-20 Dear Mr. Winegar: The Solid Waste Section completes a review of the received Slope Repair and Grading Plan (FID 1324013) at the above-referenced inactive industrial landfill facility, permit # 3420-INDUS-2005 and has few comments below: 1. According to the “Boundary Data” for Slope Stability Analyses, the restored side slope should be 20.6 degrees, or approximately 2.6 (horizontal) to 1 (vertical) slope. The 2 (horizontal) to 1 (vertical) slope shown on the Slope Profile/ Drawing No. CP-01 is incorrect. Please correct the typo. 2. The CQA Plan (Table 1) and Specifications fail to provide “passing” criterium for each listed test item in Table 1. For example, what is acceptable range for the plastic index (PI) by ASTM D 4318? What is acceptable in-place density and moisture content according to the results from Standard Proctor (ASTM D 698)? What is the minimum shear strength (in term of the cohesion and/or friction angle) of the earthen material according to testing method ASTM D 3080? Please properly address the comments and resubmit the final Slope Repair and Grading Plan. If you have any question of the comments please contact myself. Have a wonderful day.                                                                                                  From: Kemppinen, Hannu <HKemppinen@LaBellaPC.com>   Sent: Tuesday, July 16, 2019 5:28 PM  To: Chao, Ming‐tai <ming.chao@ncdenr.gov>; Stanley, Sherri <Sherri.Stanley@ncdenr.gov>  Cc: Winegar, James <James.Winegar@omnisource.com>; Davis, Amy <ADavis@LaBellaPC.com>  Subject: [External] Omnisource Kernersville Slope Repair SW # 34‐20     Ming-Tai, Chao Environmental Engineer, Solid Waste Section Division of Waste Management North Carolina Department of Environmental Quality 919.707-8251 (Office) Ming.Chao@ncdenr.gov 2 CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to  report.spam@nc.gov    Ming, In the attached we are submitting the insurance adjustor approved plans for the Omnisource Kernersville Facility slope repair. We understand from your June 5, 2019 correspondence that the Section wishes to integrate this  document into the inactive industrial landfill, Permit # 34‐20.  Hannu Kemppinen, PG LaBella Associates | Senior Project Manager 336-790-2252 direct 336-323-0092 office 336-209-7156 mobile 2211 West Meadowview Road, Suite 101 Greensboro, NC 27407 labellapc.com | Your Joyce Engineering Team Under a New Name