Loading...
HomeMy WebLinkAbout4501_Henderson_MSWLF_LFG_FID1321660_20190524pENR USE ONLY: t ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #: NC DENR I I Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 26 surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Golder Associates NC, Inc. on behalf of Henderson County Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: David Y. Reedy II Phone: 336-852-4903 E-mail: dreedy@golder.com NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) Henderson County Closed Landfill 191 Transfer Station Drive 45-01 .1600/.0500 May 21, 2019 Hendersonville, NC 28791 Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring ❑ Detection Monitoring Assessment Monitoring Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells 0 Methane gas monitoring data Groundwater monitoring data from private water supply wells ❑ Corrective action data (specify) Leachate monitoring data Surface water monitoring data Other(specify) Notification attached? BX No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration ❑ Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. David Y. Reedy II, PG Senior Hydrogeologist 336-852-4903 Facili present ' Na Title (Area Code) Telephone Number Affix NC Licensed/ Pfpfessignal Geologist Seal Signature Date Golder Associates NC, Inc., 5B Oak Branch Drive, Greensboro, NC 27407 Facility Representative Address C-2862 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 GOLDER May 23, 2019 Ms. Jaclynne Drummond, Hydrogeologist North Carolina Department of Environmental Quality Division of Waste Management - Solid Waste Section 2090 US Highway 70 Swannanoa, North Carolina 28778 828-296-4706 jaclynne.drummond@ncdenr.gov METHANE MONITORING RESULTS — SECOND QUARTERLY EVENT OF 2019 CLOSED HENDERSON COUNTY LANDFILL, PERMIT NO. 45-01 HENDERSON COUNTY, NORTH CAROLINA Dear Jackie, 0839650618.204 Attached are the results from the May 21, 2019, second quarterly methane monitoring event conducted at the above -referenced facility. As shown on the attached Boundary Gas Probe Monitoring Log, methane was not detected above the lower explosive limit (LEL) in any compliance methane monitoring points during the event. Methane was detected above the LEL at assessment methane monitoring well TR-2. No methane was detected in the facility structures during this compliance monitoring event. If you have any questions or concerns, please contact us at 336-852-4903. Sincerely, Golder Associates NC, Inc. David "Dusty" Y. Reedy II, PG Rachel P. Kirkman, PG Senior Hydrogeologist Associate and Senior Consultant Golder Associates NC, Inc. 5B Oak Branch Drive, Greensboro, North Carolina, USA 27407 Engineering Lic. No. C-2862/Geology Lic. No. C-399 T: +1 336 852-4903 F: +1 336 852-4904 Golder Associates NC, Inc. is a licensed user of the Golder trademark, and an associated operating entity. Golder and the G logo are trademarks of Golder Associates Corporation. golder.com Ms. Jaclynne Drummond, Hydrogeologist 0839650618.204 North Carolina Department of Environmental Quality May 23, 2019 CC: Marcus Jones, PE, Director of Engineering, Henderson County, 1 Historic Courthouse Square, Suite 6, Hendersonville, NC 28792. 828-694-6560. majones@hendersoncountync.org Greg Wiggins, Operations Manager, Henderson County, 191 Transfer Station Drive, Hendersonville, North Carolina 28791. 828-694-7982. gwiggins@hendersoncountync.org Attachments: Boundary Gas Probe Monitoring Log — May 21, 2019 Cut-off Trench LFG Vent Monitoring Log — May 21, 2019 Methane Monitoring Location Map Calibration Record gAprojectslhenderson county\0839650618\phase 204 - 2nd qlr Ifg 2019\200 deliverables\252 final issued\0839650618.202-001-r-rev0- Hg_rpt_nov_2018.docx GOLDER BOUNDARY PROBE MONITORING LOG Project Name: Henderson County Landfill Site Contact: Greg Wiggins Starting Temperature: 83°F Starting Barometric Pressure: 27.8 in Ho Monitoring Equipment: GEM 2000 Plus Date: 05/21 /19 Project Number: 0839650618.204 Technician(s): Erik Vasko End Temperature: 82°F End Barometric Pressure: 27.8 in Ha Monitoring Location Time Time Pumped sec (sec) %Methane CH ( a) Carbon Dioxide (CO2) %Oxygen (O2) %Balance Gas Initial ° /° LEL Stabalized ° /° LEL Hydrogen Sulfide (1-12S, ppm) Monitoring Point Status g M13-1 13:41 60 0.0 4.7 14.8 80.5 0 0 0 MSW Compliance Well MP-3 13:31 60 0.0 5.4 12.9 81.7 0 0 0 MSW Compliance Well MP-4 13:22 60 0.1 11.8 4.9 83.2 2 2 0 MSW Compliance Well MP-7 13:08 60 0.0 5.8 10.1 84.1 0 0 0 MSW Compliance Well MP-8 12:51 60 0.0 0.0 20.3 79.7 0 0 0 MSW Compliance Well MP-9 12:58 60 0.0 2.0 17.6 80.4 0 0 0 MSW Compliance Well Activity Building 12:22 200 0.0 0.0 20.5 79.5 0 0 0 Structure Animal Shelter 12:06 200 0.0 0.1 20.6 79.3 0 0 0 Structure Break House 12:19 200 0.0 0.0 20.5 79.5 0 0 0 Structure Bus Garage 12:01 200 0.0 0.0 20.7 79.3 0 0 0 Structure Convenience Center 12:32 200 0.0 0.0 20.5 79.5 0 0 0 Structure Maintenance Shop 12:27 200 0.0 0.0 20.5 79.5 0 0 0 Structure Scalehouse 12:13 200 0.0 0.1 20.6 79.3 0 0 0 Structure Trace Barn 12:44 200 0.0 0.0 20.5 79.5 0 0 0 Structure MP-6 12:37 60 0.0 0.0 20.3 79.7 0 0 0 MSW Assessment Well TR-2 13:03 60 10.4 12.0 12.9 64.7 208 208 0 MSW Assessment Well TR-3 12:40 60 4.2 5.3 17.5 73.0 84 84 0 MSW Assessment Well LFG-101 13:57 60 0.0 0.0 20.4 79.6 0 0 0 C&D Compliance Well LFG-102 13:54 60 0.0 1.7 17.1 81.2 0 0 1 C&D Compliance Well LFG-103 13:50 60 0.0 6.1 12.1 81.8 0 0 0 C&D Compliance Well Completed by: 4 GOLDER CUT-OFF TRENCH LFG VENT MONITORING LOG Project Name: Henderson County Landfill Site Contact: Greg Wiggins Starting Temperature: 83° F Starting Barometric Pressure: 27.8 in Ho Monitoring Equipment: GEM 2000 Plus Project Number: 0839650618.204 Technician(s): Erik Vasko End Temperature: 82° F End Barometric Pressure: 27.8 in Ha Date: 05/21 /19 Monitoring Location Time Time Pumped (sec) ° /° Methane (CH4) % Carbon Dioxide (CO2) ° /° Oxygen (Oz) ° /° Balance Gas Initial %LEL Stabalized %LEL Hydrogen Sulfide (HZS, PPM) Monitoring Point Location Cut -Off Trench Vent 1 13:24 60 10.2 19.6 0.7 69.5 204 204 0.0 Southern Vent Cut -Off Trench Vent 2 13:20 60 0.0 0.0 20.4 79.6 0 0 0.0 Northern Vent Completed by: � v i� GOLDER