HomeMy WebLinkAbout4501_Henderson_MSWLF_LFG_FID1321660_20190524pENR USE ONLY: t ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #:
NC DENR I I Environmental Monitoring
Division of Waste Management - Solid Waste Reporting Form
Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Instructions:
Prepare one form for each individually monitored unit.
Please type or print legibly.
Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 26 surface water standards. The notification
must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing
condition, etc.).
Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits.
Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the
facility (NCAC 13B .1629 (4)(a)(i).
Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste
Section, 1646 Mail Service Center, Raleigh, NC 27699-1646.
Solid Waste Monitoring Data Submittal Information
Name of entity submitting data (laboratory, consultant, facility owner):
Golder Associates NC, Inc. on behalf of Henderson County
Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address:
Name: David Y. Reedy II Phone: 336-852-4903
E-mail: dreedy@golder.com
NC Landfill Rule: Actual sampling dates (e.g.,
Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006)
Henderson County Closed Landfill 191 Transfer Station Drive 45-01 .1600/.0500 May 21, 2019
Hendersonville, NC 28791
Environmental Status: (Check all that apply)
❑ Initial/Background Monitoring ❑ Detection Monitoring Assessment Monitoring Corrective Action
of data submitted: (Check all that apply)
Groundwater monitoring data from monitoring wells 0 Methane gas monitoring data
Groundwater monitoring data from private water supply wells ❑ Corrective action data (specify)
Leachate monitoring data
Surface water monitoring data Other(specify)
Notification attached?
BX No. No groundwater or surface water standards were exceeded.
Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water
monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and
preliminary analysis of the cause and significance of any concentration
❑ Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample
values and explosive methane gas limits.
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct.
Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas
levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there
are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment.
David Y. Reedy II, PG Senior Hydrogeologist 336-852-4903
Facili present ' Na Title (Area Code) Telephone Number
Affix NC Licensed/ Pfpfessignal Geologist Seal
Signature Date
Golder Associates NC, Inc., 5B Oak Branch Drive, Greensboro, NC 27407
Facility Representative Address
C-2862
NC PE Firm License Number (if applicable effective May 1, 2009)
Revised 6/2009
GOLDER
May 23, 2019
Ms. Jaclynne Drummond, Hydrogeologist
North Carolina Department of Environmental Quality
Division of Waste Management - Solid Waste Section
2090 US Highway 70
Swannanoa, North Carolina 28778
828-296-4706
jaclynne.drummond@ncdenr.gov
METHANE MONITORING RESULTS — SECOND QUARTERLY EVENT OF 2019
CLOSED HENDERSON COUNTY LANDFILL, PERMIT NO. 45-01
HENDERSON COUNTY, NORTH CAROLINA
Dear Jackie,
0839650618.204
Attached are the results from the May 21, 2019, second quarterly methane monitoring event conducted at the
above -referenced facility. As shown on the attached Boundary Gas Probe Monitoring Log, methane was not
detected above the lower explosive limit (LEL) in any compliance methane monitoring points during the event.
Methane was detected above the LEL at assessment methane monitoring well TR-2.
No methane was detected in the facility structures during this compliance monitoring event. If you have any
questions or concerns, please contact us at 336-852-4903.
Sincerely,
Golder Associates NC, Inc.
David "Dusty" Y. Reedy II, PG Rachel P. Kirkman, PG
Senior Hydrogeologist Associate and Senior Consultant
Golder Associates NC, Inc.
5B Oak Branch Drive, Greensboro, North Carolina, USA 27407
Engineering Lic. No. C-2862/Geology Lic. No. C-399
T: +1 336 852-4903 F: +1 336 852-4904
Golder Associates NC, Inc. is a licensed user of the Golder trademark, and an associated operating entity.
Golder and the G logo are trademarks of Golder Associates Corporation. golder.com
Ms. Jaclynne Drummond, Hydrogeologist
0839650618.204
North Carolina Department of Environmental Quality May 23, 2019
CC: Marcus Jones, PE, Director of Engineering, Henderson County, 1 Historic
Courthouse Square, Suite 6, Hendersonville, NC 28792. 828-694-6560.
majones@hendersoncountync.org
Greg Wiggins, Operations Manager, Henderson County, 191 Transfer
Station Drive, Hendersonville, North Carolina 28791. 828-694-7982.
gwiggins@hendersoncountync.org
Attachments: Boundary Gas Probe Monitoring Log — May 21, 2019
Cut-off Trench LFG Vent Monitoring Log — May 21, 2019
Methane Monitoring Location Map
Calibration Record
gAprojectslhenderson county\0839650618\phase 204 - 2nd qlr Ifg 2019\200 deliverables\252 final issued\0839650618.202-001-r-rev0-
Hg_rpt_nov_2018.docx
GOLDER
BOUNDARY PROBE MONITORING LOG
Project Name: Henderson County Landfill
Site Contact: Greg Wiggins
Starting Temperature: 83°F
Starting Barometric Pressure: 27.8 in Ho
Monitoring Equipment: GEM 2000 Plus
Date: 05/21 /19
Project Number: 0839650618.204
Technician(s): Erik Vasko
End Temperature: 82°F
End Barometric Pressure: 27.8 in Ha
Monitoring
Location
Time
Time Pumped
sec
(sec)
%Methane
CH
( a)
Carbon
Dioxide
(CO2)
%Oxygen
(O2)
%Balance
Gas
Initial
°
/° LEL
Stabalized
°
/° LEL
Hydrogen
Sulfide
(1-12S, ppm)
Monitoring Point Status
g
M13-1
13:41
60
0.0
4.7
14.8
80.5
0
0
0
MSW Compliance Well
MP-3
13:31
60
0.0
5.4
12.9
81.7
0
0
0
MSW Compliance Well
MP-4
13:22
60
0.1
11.8
4.9
83.2
2
2
0
MSW Compliance Well
MP-7
13:08
60
0.0
5.8
10.1
84.1
0
0
0
MSW Compliance Well
MP-8
12:51
60
0.0
0.0
20.3
79.7
0
0
0
MSW Compliance Well
MP-9
12:58
60
0.0
2.0
17.6
80.4
0
0
0
MSW Compliance Well
Activity Building
12:22
200
0.0
0.0
20.5
79.5
0
0
0
Structure
Animal Shelter
12:06
200
0.0
0.1
20.6
79.3
0
0
0
Structure
Break House
12:19
200
0.0
0.0
20.5
79.5
0
0
0
Structure
Bus Garage
12:01
200
0.0
0.0
20.7
79.3
0
0
0
Structure
Convenience Center
12:32
200
0.0
0.0
20.5
79.5
0
0
0
Structure
Maintenance Shop
12:27
200
0.0
0.0
20.5
79.5
0
0
0
Structure
Scalehouse
12:13
200
0.0
0.1
20.6
79.3
0
0
0
Structure
Trace Barn
12:44
200
0.0
0.0
20.5
79.5
0
0
0
Structure
MP-6
12:37
60
0.0
0.0
20.3
79.7
0
0
0
MSW Assessment Well
TR-2
13:03
60
10.4
12.0
12.9
64.7
208
208
0
MSW Assessment Well
TR-3
12:40
60
4.2
5.3
17.5
73.0
84
84
0
MSW Assessment Well
LFG-101
13:57
60
0.0
0.0
20.4
79.6
0
0
0
C&D Compliance Well
LFG-102
13:54
60
0.0
1.7
17.1
81.2
0
0
1
C&D Compliance Well
LFG-103
13:50
60
0.0
6.1
12.1
81.8
0
0
0
C&D Compliance Well
Completed by:
4 GOLDER
CUT-OFF TRENCH LFG VENT MONITORING LOG
Project Name: Henderson County Landfill
Site Contact: Greg Wiggins
Starting Temperature: 83° F
Starting Barometric Pressure: 27.8 in Ho
Monitoring Equipment: GEM 2000 Plus
Project Number: 0839650618.204
Technician(s): Erik Vasko
End Temperature: 82° F
End Barometric Pressure: 27.8 in Ha
Date: 05/21 /19
Monitoring Location
Time
Time Pumped
(sec)
°
/° Methane
(CH4)
% Carbon
Dioxide
(CO2)
° /° Oxygen
(Oz)
° /° Balance
Gas
Initial
%LEL
Stabalized
%LEL
Hydrogen
Sulfide
(HZS, PPM)
Monitoring Point
Location
Cut -Off Trench Vent 1
13:24
60
10.2
19.6
0.7
69.5
204
204
0.0
Southern Vent
Cut -Off Trench Vent 2
13:20
60
0.0
0.0
20.4
79.6
0
0
0.0
Northern Vent
Completed by: � v
i� GOLDER