Loading...
HomeMy WebLinkAboutSDTF9207_INSP_20190329FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 1 of 2 UNIT TYPE: Lined MSWLF LCID YW Transfer Compost SLAS COUNTY: Wake Closed MSWLF HHW White goods Incin T&P FIRM PERMIT NO.: SDTF-92-07 CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF X FILE TYPE: COMPLIANCE Date of Site Inspection: 03/29/2019 Date of Last Inspection: 11/29/2018 FACILITY NAME AND ADDRESS: Bobby & Carolyn Stallings, and Lee Moore Stallings Septic Service 7132 Hidden Valley Trail Garner, NC 27529 GPS COORDINATES: N: 35.61908 E: -78.59076 FACILITY CONTACT INFORMATION: Name: Bobby & Carolyn Stallings, and Lee Moore Address: Same as above Telephone: 919-779-1074 Email address: stallingsseptics@bellsouth.net PARTICIPANTS: Chester Cobb (DWM), Brett Martin (WCDES), and Bobby Stallings STATUS OF PERMIT: Active EXPIRES: 05/02/2023 PURPOSE OF SITE VISIT: Routine STATUS OF PAST NOTED VIOLATIONS: No violations noted on the previous inspection. OBSERVED VIOLATIONS: NONE The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 2 of 2 ADDITIONAL COMMENTS 1) The required signage is present at the entrance to the facility. 2) Access road was in excellent shape. 3) The tanks were accessible for inspection. 4) The 4 above ground steel tanks appeared to be in compliance with NC Septage Management Rules. No leaks noticed. 5) Septage appears to be handled in at the facility in a way that prevents spills of septage on the ground. No spills noticed at the maximizer or tanks. 6) No odor or vector issues noticed. 7) No change noticed that would affect setback distances. 0BPicture of maximizer. Please contact me if you have any questions or concerns regarding this inspection report. ________________________________________ Phone: (919) 707-8283 . Chester R. Cobb, Environmental Program Consultant Division of Waste Management, NCDEQ Regional Representative Sent on: X Email Hand delivery US Mail Certified No. [ _]