HomeMy WebLinkAbout1203_Burke_JohnsRiver_MSWLF_CDLF_LFG_FID1320928_20190516I pENR USE ONLY ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #:
NC DENR I I Environmental Monitoring
Division of Waste Management - Solid Waste Reporting Form
Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Instructions:
Prepare one form for each individually monitored unit.
Please type or print legibly.
Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 26 surface water standards. The notification
must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing
condition, etc.).
Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits.
Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the
facility (NCAC 13B .1629 (4)(a)(i).
Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste
Section, 1646 Mail Service Center, Raleigh, NC 27699-1646.
Solid Waste Monitoring Data Submittal Information
Name of entity submitting data (laboratory, consultant, facility owner):
Joyce Engineering
Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address:
Name: Van Burbach Phone: (336) 323-0092
E-mail: Vburbach@labellapc.com
NC Landfill Rule: Actual sampling dates (e.g.,
Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006)
Johns River 2500 Marsh Trail
Waste Management Facility 12-03 .1600 May 7, 2019
C&D-over-MSWLF Morganton, NC
Environmental Status: (Check all that apply)
❑ Initial/Background Monitoring ❑ Detection Monitoring Assessment Monitoring Corrective Action
of data submitted: (Check all that apply)
Groundwater monitoring data from monitoring wells ❑X
Groundwater monitoring data from private water supply wells
Leachate monitoring data El
water monitoring data
Methane gas monitoring data
Corrective action data (specify)
Other(specify)
Notification attached?
B No. No groundwater or surface water standards were exceeded.
Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water
monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and
preliminary analysis of the cause and significance of any concentration.
�X Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample
values and explosive methane gas limits.
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct.
Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas
levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there
are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment.
G. Van Ness Burbach, Ph.D., P.G. Technical Consultant
Facili a ��n��ve (Print) 000�1Title
Signature Date
2211 W. Meadowview Rd., Ste. 101 Greensboro, NC 27407
Facility Representative Address
C-0782
NC PE Firm License Number (if applicable effective May 1.. 2009)
Revised 6/2009
(336) 323-0092
(Area Code) Telephone Number
Affix NC Licensed/ Professional Geologist Seal
s�•��N CARO��
z�Jcr�9,
SEAL
1349
G G'FOLOG�� ��v
SS
LaBeRa
Powered by oartnershiD.
May 16, 2019
Mr. Miles Champion
Burke County
General Services Director/County Engineer
P.O. Box 219
Morganton, NC 28680
RE: Burke County, Johns River Landfill
Permit Number 12-03
Second Quarterly Landfill Gas Monitoring Report of 2019
Project No. 2181871, Phase 05
Dear Mr. Champion:
On behalf of Burke County, North Carolina, Labella Associates (LABELLA) is submitting the attached
methane monitoring results for Johns River Landfill, Permit Number 12-03. The 2019 second
quarter landfill gas monitoring event was performed on May 07, 2019.
During this event, gas probes GP-1S, GP-1D, GP-2S, GP-21, GP-2D, GP-4, GP-5, GP-6, GP-7, and GP-8
were monitored in accordance with the facility's Landfill Gas Monitoring Plan. Additionally, gas
monitoring points GMP-1 through GMP-7, GMP-7A, GMP-8, GMP-9, GMP-10, GMP-11, GMP-12, GMP-
13 and GMP-14 were monitored. GP-3S and GP-3D were abandoned in February 2018 for
construction of new landfill Phases 2A and 4. The locations of the gas probes and monitoring points
are depicted in Drawing 1. The monitoring data for the gas probes and buildings are summarized in
the attached Landfill Gas Monitoring Data Logs.
Methane was detected above the lower explosive limit (LEL) in gas probes GP-2S, GP-21, GP-2D, GP-4
and GP-5. Gas probes GP-2S, GP-21, and GP-2D are a nested set and are located in close proximity
to waste in the old C&D-over-MSW landfill and are not considered boundary probes. GP-4 is located
between the two landfills and is also not a boundary probe. GP-5 was in exceedance of the LEL for
the third time during this event. GP-5 is located over 500 feet from the nearest property boundary,
and since it is only slightly above the LEL at 5/2% methane, it is unlikely to indicate an exceedance
at the property boundary. GP-5 is located next to a building which we will begin to monitor as an
additional gas monitoring point during each quarterly sampling event.
No exceedances were recorded for any of the other probes, monitoring points, or structures.
Respectively, the methane detections and exceedances are summarized in Table 1 and Table 2.
We have included an EMRF and will forward a copy of this report to Jaclynne Drummond with the
NCDEQ Solid Waste Section. This report should be added to the facility's records. The next quarterly
monitoring event is tentatively scheduled for the third quarter of 2019. If we can provide any
additional information please do not hesitate to call me at (336) 323-0092.
2211 W. Meadowview Road #1o1 i Greensboro. NC 27407 p (336) 323-0092
www.LabeLLapc.com
Respectfully submitted,
La Bella Associates
Gretta Eller -Billings
Environmental Staff Consultant
Attachments: Environmental Monitoring Reporting Form (EMRF)
Tables 1 & 2
Landfill Gas Monitoring Logs
Site Map with Gas Monitoring Locations - Drawing 1
cc: Jaclynne Drummond, NCDEQ
Burke Co. -Johns River Landfill
Permit #:
Monitoring Date:
12-03
5/7/2019
Table 1: Methane & Hydrogen Sulfide Detections
LFG
Probe
CH4
(%Vol.)
CH4
(%LEL)
H2S
(%Vol.)
GP-2 S
59.4
1188
0
G P-2 1
58.2
1164
0
GP-2 D
58.1
1162
0
GP-4
59.1
1182
0
G P-5
5.2
104
0
Table 2: Methane Exceedances of the LEL
LFG
Probe
CH4
(%Vol.)
CH4
(%LEL)
GP-2 S
59.4
1188
G P-2 1
58.2
1164
GP-2 D
58.1
1162
GP-4
59.1
1182
G P-5
5.2
104
Notes:
CH4 = Methane. H2S = Hydrogen Sulfide.
%Vol. = Concentration in pecent-by-volume.
%LEL = Concentration as a percent of the LEL.
LEL = Lower Explosive Limit = 5%Vol for Methane.
GP = Gas Probe, permanent installation.
S = Shallow Screen. I = Intermediate Screen. D = Deep Screen.
TGP = Temporary Gas Probe for delineation study.
BOLD = Exceedance.
Burke Co., Johns River Landfill
Permit # 12-03 Labella Associates
NC Division of Waste Management - Solid Waste Section
Landfill Gas Monitoring Data Form
Notice: This form artd an}' it formation attached to it are "Public Records" as defined in NC General Statute 132-1. As such. these documents are
ai•ailable for inspection and examination by any person upon request (YC General Statute 132-6).
FacilityName: 8 urla C0 , :) C YIy1 'c K, vex✓ Permit Number: 12 - 0
Sampling Date: 5—/ 7 / 2 a 19 NC Landfill Rule (.0500 or.1600): o, ) (p 0Q
Sample Collector Name& Position:551G6odr1ik - CNV reld F,-f I-Jn / Asoei - ENS FOA reCN
Gas Meter Type & Serial Number: SDI, 5 00q S NCSOS/ y 9 Gas Meter Calibration Date: 0 w/ I0/ ZO I "1
Field Calibration Date & Time: 51711ll L5'0&D ; S
3-5/socHk/Cei GHy/�O�
Field Calibration Gas Type (15115 or 35/50): <i-% o z Field Calibration Gas Canister Expiration Date: y Y 02 % /) Z/zo?
2o��oper—H25 N S, Io/(o/2olq
Gas Meter Pump Rate: s�O y;„ q-4She r t
Ambient Air Temperature: /�S Barometric Pressure (in. or min Hg):21714 Weather Conditions: _X)S ov-er Ca3r
Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office).
Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume.
Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL.
*Hydrogen Sulfide (H2S) gas monitoring may be required for Construction c& Demolition Landfills (CDLFs). See
individual permit conditions and or Facility LFG monitoring plan.
Location or
LFG Well ID
S ample
Tube
Purge
Time of
Day
Time
Pumped
(sec)
Initial
% LEL
Stabilized
/o LEL
% CH4
(volume)
% 02
(volume)
% CO2
(volume)
% FLS*
(volume)
NOTES
67M -10
1101 Z-
&0
d. o
o. 0
Or O
Zo. 3
0, h.
O
no '
67MP--I/
Y
11.1 1(e
C)
O.0
0.0
o D
10.Z
0.4
o
MI01Z
I7
(QO
D:O
O.`o
0,0.
?0.2
0.1
O
no m LV-�
W 1
(PC)
0-0
118 Z
sq. l
0.0
WO. q
O
, Z s u
C7P--?P
14 28
�a
t�0
ss.1
0.0
yl.
0
d.39 3 ur-c-
z Cf��
Y
W
(Po
0.0
I In
s ,
0.0
yO. .S
0
o.zo
P-LZGb(�c}
y
1(0 2
(oo 10.0
11(0'
,SS. 2
d. C)
yl. 9
0
O. Z&
7 -S
`
1&3�
Coo
O.O
10q
-6
D
D,/9 jorev St
CM - q
ke qY
6D
0.0
0.0
6.0
90.1
0.I
O
rlv
nmp
t 41
0
0.0
0.0
CMP-Z 1`
IbSI
(49D 10,C)
10,0
a,
20.3
O,1
0
00
NOTE: 1f needed attach additional data fornis to include additional LFG monitoring data locations for die jacility.
ACM.N LEVELS: Methane: >1.25% by volume (inside structures) AND >i% by volume (at facility boundary)
Hydrogen Sulfide: >1% by volume (inside structures) AND >4% by volume (at facility boundary)
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments
are true and correct. I am aware that there are significant penalties for making any false statement, representation,
or ce ification including the possibili of a fine and imprisonment.
Iry v f�-el I l eck
IGNA TITLE
Revised — March 6, 2017
\C Division of Waste Alanagenient -Solid «aste Section
Landfill Gas Nlonitoring Data Form
Nonce: ihr.;frrrnrandamrr ufornrarnvra;tacheamrrare "Prrhlrt Pdcordi"cisdefinedrn \[ GenrralSurrrrr; 13'4 Is so-.Ir ;b: i r,nr.+rr+ar
cnudcrnle for•nrspecnwr be "I I' person «far+ requer; r\'C Garerul Barure 13 .6.
Facilit} Name: vcOutiju - JahV1 S Permit Number:
Sampling Date: 5—/ ZZ Z019 \C Landfill Rule (.0i00 or.1600):
I7-O3
(e 00
Sample Collector Name cE Position: /. YUISon —EA%y Fejd— l ex_h /:5, Slebdni k " Oj\j
Gas deter TNpe R Serial \umber: 6 sc�o SN :ZSDS/'{p f1 /IQ/Z[�!
/ Gas Meter Calibration Date: Tl
Field Calibration Date & Time. s��14 @DeaSs-
ST/sa Crt coy CN/Cost IZ/V11202Z
Field Calibration Gas T\pe 115 I i or35 i0): y `/• 0 z Field Calibration Gas Canister Expiration Date: bt' &/i Z/Zo2 z
�/ Zoom r 1+2 s
Gas deter Pump Rate: 3�r�`-/I �ir� SfesH,a r His
-Ambient Air Temperature: 7Ds Barometric Pressure (m ormm f1_0: ZS. 6 Weather Conditions: _ 70t '1—p\MrrDS�
Instructions: Under -Location or LFG Well". list monitoring \\ell = or describe monitoring location (e.g.. inside field office).
Attach a test location map or dra%%ino. Report methane readings as both 4o LEL and °o CH t b\ %olume
Con%ert % C'Ha Ihi. volume! to % LEL as follo%%s: % methane (by volume)/20 = % LEL.
*1 Irdrogen Su/ftde (H.S) gas mnnitoring nun be required for Conclr•trclion R D lnalition Lcon(fills (C'[)/ Fc1 ' ,,!e
irrdiriducrl pernlil c•nncfirions and or Farilili LFG nunnitaring plus
[ ouuon or
f tI )CoilIU°
Samp',
F 1Fe
<�me aC
Dr
PStabdried
=pedln
° LFL
--
°° Cllrt
Rolumel
n O'
I,a;um i
n CO.
I ulumcr
--- i —
°n fL\l) CE'-)Pure
I olumrr
Il
7$
Z• 1
O 10.0
(0)0.0
0.0
0,0
17
Z.1
re55v�
o lo.o3
NMP_
17oS
Uv
0.0
0.0
0..0
ZD.3
0.1O
1-7q
(QO
0,0
a
0.0
ZO,7
0,0
o > sire
O no
67
17'��
(0 0
D, 0
a o
Zo, (0
0.0
►�essuev-
O no
C-AMP-q
17 l 7
O
0, O
0. 0
-0.0
0.0
Z0, (o
0, O
rre s s ur-e
0 rio
C-1MP-S
y
1711
Coo
0,0
0,0
O.O
Zo,6
0,0
re ss t
61 me- 7
(O
00
o.o
0.0
20.6
0.0
h v Y`eSS v*-L
OCMP-7A
EZZ
1
(00
0,0
D, 0
0. D
10. {o
0.0
O
1727
l00
O. o
D.O
20.E
D.
a,
CMP-5-
A
174
&0
O, O
O, 0
0.0
ZO, 4--,
0.0
>�
p
CAMP-1 S
Y
173-3
foO
O. p
D, p
D.O
ho s
U i r 4 )ceded nrrtrch addrno)a/ dar;r jornrs ra n shale ndJ�)anal LFG mo+urorrng data locarrorrs f%rr die %arrGn
ACTION LF\ Fi.S: Methane: >1.25% b\ \olume (inside structures) AND >51/16 b, %olume (at facility boundan)
Hydrogen Sulfide: >1 % b} %olume (inside structures) AND > {% by tiohrme (at facilit. boundan )
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments
are true and correct. I am aware that there are significant penalties for making any false statement, representation,
or c tif[cation " cludin t�es,�b�ifityafine and imprisonment.
[G\.ETC"RE TITLE
Revised - March 6, 2017
NC Division of Waste Management - Solid Waste Section
Landfill Gas Monitoring Data Form
Vorice: nt, fnr•nt and mrt nrfornamon niac•h__1 ro tt ur2 T011_ R-2, orrl, 'a s dafrrred ur \ C'Gerra•alStrme.•l3'-I arsu.h d_;daa,. ;n:nn,ne
CIAw1ahk for Inspection aml -ranrrnatmn b1 ant person r,po,t reque rt t \ C Gerr rat Stature 13'-6,
Facility Name: "%�ytQf•
}q Permit Number:
Sampling Date: ��% \C Landfill Rule (.0500 or.1600):
Sample Collector Name &: Position: S 151f 6celv1, k.—EN\1 Fetq-Te&j `' - ph — E1VV rEMi iec'\
Gas deter Type R Serial NumberSGbb SN':C� SDS/yet Gas deter Calibration Date:
Field Calibration Date R Time: 5-171)q
3S/so (20 /c0
Field Calibration Gas Type (1 i 15 or 35 i0): q;( D -z Field Calibration Gas Canister Expiration Date: Off: �O/1 Z/ 202 Z
3co MLf�,: 2oopP 1 ZS
Gas deter Pump Rate: n r�SL; r- 40: 10/4 /ZO Iq
-ambient Air Temperature: 70� Barometric Pressure (in. or mm FILI):21• (9Weather Conditions: / 0
Instructions: Under "Location or LFG X1 ell". list monitoring \tell = or describe monitoring location (e.g.. inside field office).
.-Attach a test location map or dra%%incr. Report methane readings as both °° LEL and °° CH4 b\ \olume.
Convert °o C114(hr volume) to % LEL as follows: % methane (by' volume)/20 = % LEL,
Hl'drogen Srrffir/e (HzS) gas nronirorirrg titan he required for Construction & Demolition Landfills tc[)JF.ci Sep
individualpermit conditions crud or f ac'ililI I FG nroniror•irrg plcnr
Loc,ition or
LFG \1 _ll IU
Sample
Tuha
Pure
-rime of
Day
Timr
Pumped
(se1I
Initial
'n LEL
Stabilized
°° LEL
"" C H.
(tolume)
°n U'
(tnlume)
i
"" CU_'
(toLime) (toluntel i \l)rl ti
2.� O ID, of re
C� Ire Y 1735
�� (c�,a
o, o
p.o
1�.�
u„uv, ucnrrtronat aara jornas ro utcrude addmonal LFG utunrtaut; rf rta 1OCattanS 1%t+' rlre facrhn
aC"rIU\ LF% ELS- Methane: >1.25% by %olume (inside structures) AND >5nb b% %olume (at Facilih boundan)
Fhdroeen Sulfide: >1 % by volume (inside structures) AND >4% b% volume (at facility boundan )
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments
are true and correct. I am ;ware that there are sieD
gnificant penalties for making any false statement, representation,
or certification including the possibility' of a fine and imprisonment.
11WGN.TITLE
Revised — March 6, 2017
1i
/ �\x PROTECTED AREA
01
�eoaAow'L1,2 GOOD;
�
-Zzx�z PZ-24 CAR BOAR
------ \k _VTION��
t\> SHOOAN_?_�
\ I
Z-10
\ \\� MW-3 —c
OIL
BATTERIES
CAR OARD /
l � \
1
FACILITY LIMIT-
7
\ -\
_
' E//HOUSE
STREAM S-4 �� \ SC -AC
0, ^ \
��lp STE
O /I MIT
I O ,
\\-21
\
/ GA o-- fVIW- 0 \ \ /
Y WASTC� \ -
-\ / OPOSED
ASTE LIMIT GP- GMP-2
� � o
-3 P-7
GOODS / _� ` \ \ �� WETLAND W3
/ \ /4� GMP-4 / f PZ-3 90 ,080000
IULCH AND nn ccE �A GP-8 /
/ \ � PALLETS �P 2 � � � PZ-5 `/
P 37 1080 Y
/ \ Y BOUNDARY /
\ / � FACILITY � O P -32
\ PROPERTY LINE (TYP I L N E /�B \/ �- + I :: / \ /
PR / B P ASE T SE 5 080—
EDGES
/ WEST AND SOUTH )
TBA
PZ-20
\ \ \ PHASE 1B ,0 � ��ETERY I
MW2 Z-42 NLE
PZ 1 TBA BA
/ I \ OD ` MW 22S SE 4 1
060
� PZ-34
/ /
P -1 \ PHASE 8 I /
\ GP-3 A
/ .-
/ l,llllll I/ GP-2 _ /
W Z-34
NLE \ \
\
\_ � � f
J
/ - \ B PHASE 2 �
/ V- 1 I \�
\ *. 4v loso
I � � � / STREAM S-2 / � 'gyp
GV-02 MW-38 Z 23 I S 3 /
E PZ-19 \ p3 STREAM /
/ O
/ GV-03 0 _ \
\\ / z / G / 0 YR FLOOD IMIT
/ 10
EXISTING PHASE 6 / ° ELEV. 1005.0
\ / / WASTE LIMITS - P _ 2 o J \ / /
�, o P AS� 3 / 7
MP- "" PHAS
PZ-17 PZ- 1 \
I/ 1
1 \ I -14 PZ-18
P LANI!PW1 NLE
\ O
�1 T EA� A J ` /
\
(CP ES LANDFILL
\)ISPO arAREA
, °
\_
WETLAND W2
-g° -9
� URRENTLY EING CLOSED)
/
TING i �
P-11 ` EDI IN
mol
il
�
1100 CEMETERY
-
-1070� _ / / — I / / GV-03 Q GAS VENT
_9 � PROTECTED
MW-12� \ GMP-12 � GAS MONITORING POINT
t� �
/ AREA
_1030 /\/ GP-4 GAS MONITORING PROBE (EXISTING)
\\0 �MW-MW-16SI / GP -
/ l� 7 GAS MONITORING PROBE(PROPOSED)
/ I VE"m / �,40 TBA TO BE ABANDONED FOR CONSTRUCTION
/ OF PHASES 2A AND 4
�.
PZ-12 PIEZOMETER
z� / GPMW-12 MONITORING WELL
Q
0 MW 18 MW 19 / 0 SMP-6 SURFACE WATER SAMPLING POINT
AB =ABANDONED
NLE = NO LONGER EXISTING
(PRESUMED DESTROYED)
GRAPHIC SCALE
0 100 200 400
(FEET)
Y
U
m
O
z
w
U)
U)
LL
O
0
O
U
w
0
z
z
0
L0
w
w
w
Q
0
>
>>00
.L
w
0
0LLI
5
LL, w0>
z z
�r
in Q w w
Q
w = w
O O U Q
Q
O
o
v
VV0
Q ti
00
jZ
N�
w�z �
�
W
�
�0 -,
U
W
OoM
J
°-'
zQmM
�zz
Q
�
w O
U
U
U
�0w
z
Z
W
N
Cl
Z
LL
�o
Z�
wQ
�U
�w =
V
Q
z�
CQ z
G
F_I—
Q D
3:O
O�U
m
Z
2
O
z
Q J
V
Jz
LL 0�
00
Z
Q
J z
O
2
PROJECT NO
277
SCALE
AS SHOWN
DRAWING NO.
LGMP-01
0
ca
J
0
0
c�
J
z
Q
J
w
0
z
Of
O
z
O
2
U)
/Q
V
0
CD
J
W
Q
0
CD
J
U
W
O
Of
CL
N
C
0
U
0
Y
m
J