Loading...
HomeMy WebLinkAboutSLAS7108_INSP_20190503FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 1 of 4 UNIT TYPE: Lined MSWLF LCID YW Transfer Compost SLAS x COUNTY: Pender Closed MSWLF HHW White goods Incin T&P FIRM PERMIT NO.: SLAS-71-08 CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF FILE TYPE: COMPLIANCE Date of Site Inspection: 05-03-2019 Date of Last Inspection: 07-19-2018 FACILITY NAME AND ADDRESS: Lewis Farms & Liquid Waste, Inc. 8155 Malpass Corner Rd. Currie, NC 28435 GPS COORDINATES: N: 34.57879 E: -78.05368 FACILITY CONTACT NAME AND PHONE NUMBER: Name: Wesley Wooten Telephone: 910-283-9823 Email address: 31TUwesley@lewisfarmsnc.comU31T Fax: 910-283-2500 FACILITY CONTACT ADDRESS: Same as above PARTICIPANTS: John Farnell – DWM STATUS OF PERMIT: Active – expired 02-20-2018 PURPOSE OF SITE VISIT: Routine STATUS OF PAST NOTED VIOLATIONS: None SEE BACK PAGE FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 2 of 4 OBSERVED VIOLATIONS: 1) Septage was observed standing on the surface of Fields ST-1 and ST-2 in several areas as noted in the pictures below. This is a violation of Rule .0842(a)(7) that states “Septage shall be applied to the surface of the land from a moving vehicle in a such a manner as to have no standing liquid or soil disturbance resulting from the waste flow after the discharge is complete.” Any remaining septage ponding needs to be incorporated into the permitted fields or vacuumed up. 2) Area of dead vegetation covered with a coating of grease septage was observed in ST-2 application fields. Crop damage that occurs from applications is a violation of Rule .0842(a)(14) that states “Grease septage shall be diluted at least 1:1 from its concentration when pumped with domestic septage or water if land applied over perennial vegetation. This dilution shall be increased if crop damage occurs…” Any remaining septage needs to be incorporated and then a cover crop established within 30 days. In ST-1 field near SDTF-71-08 NE corner in ST-1 field SEE ADDITIONAL PAGE The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 3 of 4 In ST-1 runoff from picture 1 to NE corner Ponding resulting from runoff in ST-1 field NE corner in ST-2 field with dead vegetation Proper signage ADDITIONAL COMMENTS 1- Site has proper signage 2- Good access road 3- Markers are up and appear to be accurate 4- Septage discharges appear to be within the permitted boundaries of Fields ST-1 and ST-2 5- Several application issues observed. The ponding of septage in both Fields ST-1 and ST-2 is a violation of Rule .0842(a)(7) stated in Observed violations. In the same area of Field ST-2, dead vegetation from grease application is in violation of Rule .0842(a)(14) stated in Observed violations 6- Crops were seen to have been killed 7- No objectionable odors noted 8- Setbacks appear compliant SEE ADDITIONAL PAGE FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 4 of 4 Please contact me if you have any questions or concerns regarding this inspection report. ____________________ Phone: (910) 796-7397 John Farnell Environmental Specialist II Regional Representative Sent on: 05-10-2019 Email Hand delivery x US Mail Certified No. [ 35T_]