HomeMy WebLinkAboutMO-9448_40883_CA_UST-61_20181025_24-Hour Release and UST Leak Reporting FormUST-61
24-Hour Release and UST Leak Reporting Form.
For Releases This form should be completed and submitted to the UST Section's regional office following a known or suspected release from
an underground storage tank (UST) system. This form is required to be submitted within 24 hours of discovery of a known or
in NC suspected release
(DWM USE ONLY)
Suspected Contamination? (Y/N) Y
Facility ID Number None
Incident # Risk (H,I,L,U)
Confirmed GW Contamination? (Y/N) N
Date Leak Discovered 10/19/2018
Received On Received By
Confirmed Soil Contamination ?(Y/N) Y
Comm/Non-Commercial? Comm
Reported by (circle one): Phone, Fax or Report
Samples Taken?(Y/N) Y
Reg/Non-regulated? Non -regulated
Region
Free Product? (Y/N) Y If Yes, State Greatest
'14"
Thickness
INCIDENT DESCRIPTION
Incident Name: GADO Building
Address: 5318 Morris Field Drive
County: Mecklenburg
Regional Office (circle one): AsheviIl Mooresville ayetteville,
City/Town: Charlotte
7ZIPode: 28208
Raleigh, Washington, Wilmington, Winston- em
Latitude (decimal degrees): 35.212133 Longitude (decimal degrees) :-80.932548
Obtained by:
❑ GPS
Briefly describe suspected or confirmed release: (including but not limited to: nature of release, date of release, amount
of release, amount of free product present and recovery efforts, initial responses conducted, impacts to receptors)
❑ Topographic map
❑ GIS Address matching
® Other Google Maps
❑ Unknown
Describe location:
CLT Airport
Tank discovered during demolition of building. Tank removed on 10/19/2018 by Demolition Contractor and corrosion
holes observed in tank. The tank was used to store heating oil for a boiler until about 1990, when boiler was converted
to natural gas. Soil excavation performed at time of tank removal based on field screening data. Very small amount of
heating oil noted on soil beneath tank.
HOW RELEASE WAS DISCOVERED (Release code)
(Check one)
❑ Release Detection Equipment or Methods ❑ Visual/Odor ❑ Groundwater Contamination
® During UST Closure/Removal ❑ Water in Tank ❑ Surface Water Contamination
❑ Property Transfer ❑ Water Supply Well Contamination ❑ Other (specify)
SOURCE OF CONTAMINATION
Source of Release Cause of Release Type of Release Product Type Released
(Check one to indicate primary (Check one to indicate primary (Check one) (Check one to indicate primary product type
source) cause) released)
®Tank ❑ Spill ®Petroleum ❑ Gasoline/ Diesel/ ❑ DieselNeg. Oil
❑ Piping ❑ Overfill ❑ Non -Petroleum Kerosene Blend e
Heating Oil ❑ Vegetable Oil 100 /o
❑ Dispenser ®Corrosion ❑ Both ❑ Other Petroleum ❑ E10—E20
❑ Submersible Turbine Pump ❑ Physical or Mechanical Products
❑
Damage Location ❑ Metals E21 — E84
❑ Delivery Problem
(Check one) ❑ Other Inorganics ❑ E85 — E99
❑ Install Problem
❑ Other ❑ Other Organics Ethanol 100%
❑Other ® Facility ❑
❑ Unknown
❑ Unknown ❑ Residence ❑ E01 — E09
Definitions presented on reverse Definitions presented on reverse ❑ Other
OWnaLShiD
1 Municipal 2. Military 3. Unknown 4. Private 5. Federal 6. County 7. State
Operation Type
1. Public Service 2. Agricultural 3. Residential 4. Education/Relig. 5. Industrial 6. Commercial 7. Mining (ZED
UST Form 61 (02/08) Page 1 of 2
IMPACT ON DRINKING WATER SUPPLIES
Water Supply Wells Affected? 1. Yes
CD 3. Unknown
Number of Water Supply Wells Affected
Water Supply Wells Contaminated: (Include Users Names, Addresses and Phone Numbers. Attach additional sheet if necessary)
1.
2.
3.
UST SYSTEM OWNER
UST Owner/Company
UNKNOWN
Point of Contact
Address
City
State
Zip Code
Telephone Number
UST SYSTEM OPERATOR
UNKNOWN
UST Operator/Company
Address
City
State Zip Code
Telephone Number
LANDOWNER AT LOCATION Or UST INCIDENT
Landowner
Address
CITY OF CHARLOTTE
600 East 4th Street
City
State
Zip Code
Telephone Number
Charlotte
NC
28202
704-359-4789
Draw Sketch of Area (showing two major road intersections) or Attach Map
Person Reporting Incident rr�,y
Company C' lrt2 L av �q�rtrJ �4,�»�2.T
Telephone Number tic 560-9dtF�-
Titlentvi
I Address 9(.c)1 [ilC/�Ct,LrffL- NC, 3236Q
Date 10a� dotg
UST Form 61 (02/08)
Page 2 of z
Definitions of Sources
Tank: means the tank that stores the product and is part of the underground storage tank system
Piping: means the piping and connectors running from the tank or submersible turbine pump to the dispenser or other end -use equipment (Vent, vapor recovery, or fill
lines are excluded.)
Dispenser: includes the dispenser and the equipment used to connect the dispenser to the piping (e.g., a release from a suction pump or from components located above
the shear valve)
Submersible Turbine Pump (STP) Area includes the submersible turbine pump head (typically located in the tank sump), the line leak detector, and the piping that
connects the submersible turbine pump to the tank
Delivery Problem: identifies releases that occurred during product delivery to the tank. (Typical causes associated with this source are spills and overfills.)
Other: serves as the option to use when the release source is known but does not fit into one of the preceding categories (e.g., for releases from vent lines, vapor
recovery lines, and fill lines)
Unknown: identifies releases for which the source has not been determined
Definitions of Causes
Spill: use this cause when a spill occurs (e.g., when the delivery hose is disconnected from the tank fill pipe or when the nozzle is removed from the dispenser)
Overfill: use when an overfill occurs (e.g., overfills may occur from the fill pipe at the tank or when the nozzle fails to shut off at the dispenser)
Physical or Mechanical Damage: use for all types of physical or mechanical damage, except corrosion (e.g., puncture of tank or piping, loose fittings, broken
components, and components that have changed dimension)
Corrosion: use when a metal tank, piping, or other component has a release due to corrosion (e.g., for steel, corrosion takes the form of rust)
Installation Problem: use when the problem is determined to have occurred specifically because the UST system was not installed properly
Other: use this option when the cause is known but does not fit into one of the preceding categories (e.g., putting regulated substances into monitoring wells)
Unknown: use when the cause has not been determined
i
m=
mk
- O;L�
bb
u O Rrndd ftoBd
x as
Cd
/C
ol
�
a
CD
-1r=.Y
W Z
O
00
�
_
�Al
x
ya
co
i-r
7
�E CL
�A�
U
VIOA
�i
a
{.
c'xi*x< _
-
B+M c✓dran Wr.y
_ a
&"d,h Pwv
•. E g
Y
j
�
i
00
el
4 ,t
(�
,ow
OO,Y
Fl}iyA
yv
Zl:=x BaR].�r%ter
�a
b
N
O
CO
6 o d a
c
O
a E
�
� W
�L
c
p
S_
a
E
O
00
M
J
, O
0
LO
U
C7
t
iL
U
V
w
�
•S~-1
'
�
LYalia<e
Neel Rd
W:v'M.e tle�ftd
}-I
O
0
YloHaro Nexl Pd
_- ldln0S8C'1 - -
O25ylyfzeNeA�
D
Beverly, Trudy
From: McDorman, James <James.McDorman@cltairport.com>
Sent: Monday, October 29, 2018 9:28 AM
To: Beverly, Trudy
Cc: Jordan, Jimmy
Subject: RE: [EXT] RE: [External] CLT-Former GADO Building
Hello Beverly,
Yes, we will submit an IAAR upon completion.
Thank you,
JAMES P MCDORMAN P.G. I ENVIRONMENTAL COMPLIANCE COORDINATOR
CHARLOTTE DOUGLAS INTERNATIONAL AIRPORT
m 704-560-9242
cltairport.com
From: Beverly, Trudy [mailto:trudy.beverly@ncdenr.gov]
Sent: Monday, October 29, 2018 9:23 AM
To: McDorman, James; Bowser, Daniel P
Subject: RE: [EXT] RE: [External] CLT-Former GADO Building
EXTERNAL EMAIL: This email originated from the Internet. Do not click any images, links or open any attachments unless you recognize and trust the sender and know
the content is safe. Please forward all suspicious email to bad.mail@charlottenc.gov.
Hi James,
I did get the forwarded UST-61 from Dan. When completed, the Initial Action Abatement Report should be submitted
per the policies below.
Let me know if you have any questions.
Document Submittal & UST File Names for Laserfiche Policies:
httos://files.nc.Rov/ncdea/Waste%20Manaeement/DWM/UST/Corrective%2OAction/Electronic%2ODocument%2OSubmi
ttal%20Memo%2OUpdate.pdf
httns://files.nc. tiov/ncdea/Waste%20ManaLyement/D WM/UST/Corrective%2OAction/UST%20file%20names%20for%20
Laserfiche.docx
Have a wonderful day,
Trudy
Trudy Beverly, L.G.
Hydrogeologist, Division of Waste Management
North Carolina Department of Environment Quality
Underground Storage Tanks Section
Corrective Action Branch
Mooresville Regional Office
(704) 235-2182 (Office)
Trudy.Beve rlyPncdenr.eov
+.:' :+. 'X 4 w, Fw : L ' .1, 11 4 .. 'J....1rh &1 ti p■ . %1 •' :: " %
Branch's Underground Storage Tanks Website Address: https://deg.nc.gov/about/divisions/waste-management/ust
Branch's Above Ground Storage Tanks Website Address: https://deg.nc.gov/about/divisions/waste-
management/ust/ast-program
INTERACTIVE MAPS WITH DWM SITES AND PERMITTED FACILITIES:
https://deg.nc.gov/about/divisions/waste-management/waste-management-rules-data/waste-management-gis-maps
File Review Procedures:
https://deg.nc.gov/about/divisions/waste-management/ust/file-review-procedures#mooresville-regional-office
ONLINE ACCESS TO UST SECTION DOCUMENTS (Laserfiche):
https://edocs.deg.nc.gov/WasteManagement/Search.aspx
Document Submittal & UST File Names for Laserfiche Policies:
https://files.nc.gov/ncdeq/Waste%2OManagement/DWM/UST/Corrective%2OAction/Electronic%2ODocument%2OSubmi
ttal%20Memo%20UPdate.pdf
https:Hfiles.nc. izov/ncdeq/Waste%2OManaizement/DWM/UST/Corrective%2OAction/UST%20file%20names%20for%20
Laserfiche.docx
From: McDorman, James [mailto:James.McDorman@cltairport.com]
Sent: Monday, October 29, 2018 9:03 AM
To: Bowser, Daniel P <dan.bowser@ncdenr.gov>
Cc: Beverly, Trudy <trudy.beverly@ncdenr.gov>
Subject: RE: [EXT] RE: [External] CLT-Former GADO Building
Thank you Dan.
JAMES P MCDORMAN P.G. I ENVIRONMENTAL COMPLIANCE COORDINATOR
CHARLOTTE DOUGLAS INTERNATIONAL AIRPORT
m 704-560-9242
cltairport.com
From: Bowser, Daniel P [mailto:dan.bowser@ncdenr.gov]
Sent: Monday, October 29, 2018 8:59 AM
To: McDorman, James
Subject: [EXT] RE: [External] CLT-Former GADO Building
EXTERNAL EMAIL: This email originated from the Internet. Do not click any images, links or open any attachments unless you recognize and trust the sender and know
the content is safe. Please forward all suspicious email to bad.mail(c_r�charlottenc.gov.
James,
I forwarded this to Trudy Beverly, she handles non -regulated UST releases in Mecklenburg County.
Trudy Beverly, LG - Trudy. Beverly@ncdenr.gov
Hydrogeologist
NCDEQ- Division of Waste Management
Underground Storage Tanks Section — Corrective Action Branch
Mooresville Regional Office
610 East Center Ave., Suite 301
Mooresville, NC 28115
Phone: (704) 235-2182 Fax: (704) 663-6040
Thank you,
Daniel P. Bowser, PG
Hydrogeologist
North Carolina Department of Environmental Quality
Underground Storage Tank Section - Corrective Action Branch
(704) 235-2172
dan.bowser anncdenr.aov
610 East Center Ave
Suite 301
Mooresville, North Carolina 28115
Email correspondence to and from this address is subject to the
North Carolina Public Records Law and may be disclosed to third parties.
From: McDorman, James <James.McDorman@cltairport.com>
Sent: Thursday, October 25, 2018 2:35 PM
To: Bowser, Daniel P <dan.bowser@ncdenr.gov>
Subject: [External] CLT-Former GADO Building
� , . • • . ernal email. Do not click links or open attachments unless verified. Send all suspicious email as an attachment to
0
Good afternoon Dan,
Attached please find a completed UST-61 Form for the subject facility. We have removed the tank and are
currently conducting Initial Abatement Actions. Please contact me should you have questions or require
additional information.
Thank you,
JAMES P MCDORMAN P.G. I ENVIRONMENTAL COMPLIANCE COORDINATOR
CHARLOTTE DOUGLAS INTERNATIONAL AIRPORT
m 704-560-9242
cltairport.com