Loading...
HomeMy WebLinkAbout4101_Guilford_CityofHighPoint_Riverdale_MSWLF_LFG_FID1280881_20190218DocuSign Envelope ID: 997CB724-5BF4-4BBF-9677-71 DDEBF699E8 DENR USE ONLY ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #: NC DENR I IEnvironmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Smith Gardner, Inc. Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Joan A. Smvth. PG Phone: (919) 828 - 0577 x221 E-mail: Joan@smithgardnerinc.com NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) High Point Riverdale Closed MSW Riverdale Drive, High Point, NC 41-01 .0500 February, 15, 2019 Landfill Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring ❑X Detection Monitoring ❑ Assessment Monitoring Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells ❑X Groundwater monitoring data from private water supply wells ❑ Leachate monitoring data El water monitoring data Methane gas monitoring data Corrective action data (specify) Other(specify) Notification attached? e No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. ❑X Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Joan A. Smyth, PG Senior Hydrogeologist (919) 828 - 0577 x221 Name (Print) Title (Area Code) Telephone Number 2/18/2019 Affix NC Licensed/ Professional Geologist Seal Date 14 N. Boylan Ave, Raleigh, NC 27603 Facility Representative Address F-1370 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 a k CARo. ;C� N Fn / DocuSign Envelope ID: 997CB724-5BF4-4BBF-9677-71DDEBF699E8 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these docmnents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: City of High Point Closed Riverdale Landfill Permit Number: 41-01 Date of Sampling: uu t ""' a NC Landfill Rule (.0500 or .1600): .0500 Name and Position of Sample Collector: Seth C. Rickerts - Staff Geologist Type and Serial Number of Gas Meter: ENV100 1510204 Date and Time of Field Calibration: 02/15/20191110 Calibration Date of Gas Meter: 12/2017 Type of Field Calibration Gas (15115 or 35/50): 15/15 Expiration Date of Field Calibration Gas Canister: 12/2018 Pump Rate of Gas Meter: 0.5 LPM Ambient Air Temperature: 44 F Barometric Pressure: 30.10 Hg General Weather Conditions: Partly Sunny Instructions: Under "Location or LFG Well" identify the monitoring wells or describe the location for other tests (e.g., inside buildings). A drawing showing the location of test must be attached. Report methane readings in both % LEL and % methane by volume. A reading in percent methane by volume can be converted to % LEL as follows: %methane by volume = % LEL/20 Location cir LFG Well 11) Sample Tube Purge Time Time Pumped (s) h itial 0ZEL Stabilized 0/aLEL %CH4 by Volume %2 %CO2 Totes 1-1 Watered in LFG 3 >60s 1214 >60s 0 0 0 22.3 07 LFG 4 >60s 1217 >60s 0 0 0 13.5 1.8 LFG 5 >60s 1222 >60s 0 0 0 11.1 3.4 LFG 6 >60s 1226 >60s 90 90 4.5 0.4 25.5 LFG 7 >60s 1307 >60s 2 2 0.1 21.7 1 7-1 >60s 1309 >60s 462 462 23.1 3.5 15.5 7-2 >60s 1305 >60s 0 0 0 22 1.6 7-3 >60s 1258 >60s 10 10 0.5 6.9 14.3 7-4 >60s 1256 >60s 1038 1038 51.9 0 30A LFG 8 >60s 1251 >60s 326 326 16.3 16.4 13.3 LFG 8A >60s 1252 >60s 1272 1272 63.6 0 19.8 LFG 8B >60s 1254 >60s 1150 1150 57.5 0 37.4 8-1 >60s 1249 >60s 648 648 32A 1.2 25.3 8-2 >60s 1248 >60s 127E 1278 63.9 0 34.4 8-3 >60s 1247 >60s 1278 1278 63.9 0 24.7 8-4 >60s 1244 >60s 104 104 5.2 17.5 8.4 8-5 >60s 1242 >60s 866 866 43.3 0.9 14.1 LFG 9 >60s 1240 >60s 948 948 47.4 1.1 33.5 9-1 >60s 1238 >60s 956 956 47.8 0 32.3 LFG 10 >60s 1235 >60s 14 14 0.7 13.6 11.6 Old Maint Bldg >60s 1224 >60s 0 0 0 10.7 2.6 Electrical Shop >60s 1225 >60s 0 0 0 22.1 0.9 If your facility has more gas monitoring locations than there is room on this form, please attach additional sheets listing the same information as contained on this form. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there aresignificanI pemall for making any false statement, representation, or certification including the possibility of a fine and imprisonment. -- Staff Geologist SIGNATURE TITLE DocuSign Envelope ID: 997CB724-5BF4-4BBF-9677-71DDEBF699E8 Q O M O M 0 0 N X E U C O I LM 2 CD N FL z O 2 U c O d L U a� 0 a_ ■■ x t r C'Ali N [/aoil AL ���� .,�, � � � - � ...ALL• �� r� - i O . v .r LFG-6 _ U) N co < o a_ z a co w a LFG-5Iry 04 LFG-3 ^ w _ zr r. s ti LFG-4 l{ » Cl) z . �, i r.f•. .. t i.JRa r` r Q LL 7-3 7-4 LFG-8 g_1 8-3 -r_ 8-5 0 z J Q z LFG-7 �_2 8A 8B 8-2 *{, 8-4 9-1 7.1 # J z m LU d O ' dier LFG-9 y +- - 0 LFG Probes •^ !r • wa * 150 ~ Z �wf z LU N U 300 0 300 U , Feet y __� _ .,x . `r' .IC - .ice ; .Fi ik �5. A C� — J DocuSign Envelope ID: 997CB724-5BF4-4BBF-9677-71 DDEBF699E8 This Page Intentionally Left Blank