Loading...
HomeMy WebLinkAbout1202_Burke_East_MSWLF_LFG_FID1280569_20190215pENR USE ONLY ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #: NC DENR I I Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i)- Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Joyce Engineering Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Samantha Slebodnik Phone: (336) 323-0092 E-mail: sslebodnik@joyceengineering.com NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) East Burke Landfill Rhodhiss Road (SR-1611) 12-02 .0500 February 8, 2019 Rhodhiss, NC Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring ❑ Detection Monitoring ❑ Assessment Monitoring Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells ❑X Groundwater monitoring data from private water supply wells ❑ Leachate monitoring data Surface water monitoring data ❑ Methane gas monitoring data Corrective action data (specify) Other(specify) Notification attached? ❑ No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard. NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. ❑X Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. G. Van Ness Burbach, Ph.D., P.G. Sr. Technical Consultant (336) 323-0092 Facil' e r ive (Print) Title (Area Code) Telephone Number 2 111�Izd* Affix NC Licensed/ Professional Geologist Seal Signature 2211 W Meadowview Rd,, Ste. 101 Greensboro, NC 27407 Facility Representative Address C-0782 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 Date zJcsFo9, SEAL 1349 s G,9 LOG�'R ''••yNFSS aju i `E ENGINEERING February 15, 2019 Mr. Miles Champion Burke County General Services Director/County Engineer P.O. Box 1486 Morganton, NC 28680 RE: Burke County, East Burke Landfill, Permit Number 12-02 Landfill Gas Monitoring Report — First Quarter of 2019 Project No. 2181871, Phase 05 Dear Mr. Champion; 2211 West Meadomiew Rd. Greensboro, NC 27407 tel: 336/323-0092 fax: 336/323-0093 www.JoyceEngineering.com On behalf of Burke County, North Carolina, Joyce Engineering (JOYCE) is submitting the attached methane monitoring results for East Burke Landfill, Permit Number 12-02. The 2019 first quarter landfill gas monitoring event was performed on February 8, 2019. During this event, JOYCE monitored seven gas probes (GP-1, GP-113, GP-2, GP-3, GP-4, GP-5, and GP-6). The approximate locations of the gas probes are depicted in Drawing 1. The monitoring data for the gas probes and buildings are summarized in the attached Landfill Gas Monitoring Data Log. Methane was detected above the lower explosive limit (LEL) in gas probes GP-1, GP-3, and GP-4. No exceedances were recorded for any of the other probes. These detections and exceedances are consistent with previous results and are summarized in Table 1 and Table 2, respectively. We have included an EMRF and will forward a copy of this report to Jaclynne Drummond with the NCDEQ Solid Waste Section. This report should be added to the facility's records. The next quarterly monitoring event is tentatively scheduled for the second quarter of 2019. If we can provide any additional information, please do not hesitate to call me at (336) 323-0092. Sincerely, JOYCE ENGINEERING Gretta A Eller Environmental Staff Consultant Attachments Environmental Monitoring Reporting Form (EMRF) Tables 1 & 2 Landfill Gas Monitoring Log Site Map with Monitoring Locations cc: Jaclynne Drummond, NCDEQ Burke Co. - East Burke Landfill Permit # 12-02 Date: 2/8/2019 Table 1: Methane Detections - February 8, 2019 LFG W CH4 CH4 Probe (%Vol.) (%LEL) GP-1 44.1 882 GP-3 51.4 1028 GP-4 55.9 1118 Table 2: Methane Exceedances - February 8, 2019 LFG CH4 CH4 Probe (%Vol.) (%LEL) GP-1 44.1 882 GP-3 51.4 1028 GP-4 55.9 1118 CH4 = Methane %Vol. = Concentration in pecent-by-volume. %LEL = Concentration as a percent of the LEL. LEL = Lower Explosive Limit = 5% Vol. for Methane. BOLD = Exceedance Burke Co., East Burke Landfill Permit # 12-02 Joyce Engineering NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name:_ &_4'LG Ce. - Ea-sf CXar`c e LF Permit Number: 0 - 0a Sampling Date: -21� Ia61q NC Landfill Rule (.0500 or.1600): 05-00 Sample Collector Name & Position: s• S Ieboc(-ni �_ - f0y Feld lec %n,°U T }(uairb. ' F.,-e (d co s4- k-j Gas Meter Type & Serial Number: (SEA 2000 6A _6AD SI Y Gas Meter Calibration Date Field Calibration Date & Time: -9,/S/o2.019 l2 076o 6-112019 Field Calibration Gas Type (15/15 or35/50): 15-//57 Field Calibration Gas Canister Expiration Date: a5�a0!'i Gas Meter Pump Rate: 36E� Ambient Air Temperature: %yS Barometric Pressure (in. or mm Hg): X-94, Weather Conditions: 60S 4 OwIrAsf Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well [D Sample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized % LEL % CH4 volume (volume) % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES 6P-y 1 6921 Le) 0.6 11 N 957A o-O 33,9 — &1: j6,a 6P- 3 it daa(- &0 0.0 102.1 571.4 6,0 37.4 — ,3LIJ: j6. 7 6 P- oz X 093,2 CaO 10,0 0.0 0, 0 1-3 q, 6 - Bd : v's Y- Ig X 0939 60 0.0 6. 6 6.0 174 .2, 6 — &L 7 ,1 GP- I Y 6g'!D (oo 0.6 C$� 4_lq%/ c,.o �9,s — B_j a26.3 6P- S y oggF Go 0.0 0,0 0.0 3.9 — 79.1 P- 61s1 46 0,0 O. 6 0-0 10 6,2 NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. - - /_2nt� 46"1— Fi-,lj SI ATURE TITLE Revised — March 6, 2017 a NOTES: 1. CONTOURS WERE DIGITIZED FROM THE GRANITE FALLS USGS 7 1/2' QUADRANGLE MAP. 2. WELL ,SURFACE MONITORING POINT AND GAS PROBE LOCATIONS / \ . ARE APPROXIMATE. LEGEND Ij EXISTING 100' TOPOGRAPHIC CONTOUR EXISTING 20' TOPOGRAPHIC CONTOUR APPROXIMATE LIMITS OF WASTE SPENCERJ ,n I �\ APPROXIMATE PROPERTY LINE 7 \ � I ROAD ■I ■` li \ APPROXIMATE CENTERLINE * 1 OF STREAM \ GROUNDWATER MONITORING WELL LOCATION Ar SURFACE MONITORING POINT LOCATION WATER SUPPLY WELL R EXISTING GAS PROBE LOCATION I` PROPOSED GAS PROBE LOCATION \ ! PROPOSED GAS VENT LOCATION J,V2, CRESCENT TIMBER wz w U 0 w = m¢wa� w � x a ❑ ❑ U Q ❑ �a w U ❑ a Z 0o W w N O U4 - mw-1 W 0 p sw-1 z iiwz ® ww-1 �W N�o N C�a GP-6 GP-1 B A GV-3 GRAPHIC SCALE 0 150 300 600 (FEET) Z Z_ a J O a- JZ JQ O LL U Z Q J 0 Lu w0 2 Z w } w co I­_ Q F__Z) a° ww F, - Y r) (if Z D Q 00 J PROJECT NO. 279.1012.05 SCALE AS NOTED DRAWING NO. 1