Loading...
HomeMy WebLinkAbout8106_DukeRogers_INSP_20190122FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 1 of 5 UNIT TYPE: Lined MSWLF LCID YW Transfer Compost SLAS COUNTY: Rutherford Closed MSWLF HHW White goods Incin T&P FIRM PERMIT NO.: 8106-INDUS-2009 CDLF Tire T&P / Collection Tire Monofill Industrial Landfill X DEMO SDTF FILE TYPE: COMPLIANCE Date of Site Inspection: January 22, 2019 Date of Last Inspection: April 23, 2018 FACILITY NAME AND ADDRESS: Rogers CCP Landfill James E Rogers Energy Complex (Formerly Cliffside Steam Station) 573 Duke Power Road Mooresboro, N.C. 28114 (828) 657-6314 GPS COORDINATES: N: 35.20534 W: -81.76547 FACILITY CONTACT NAME AND PHONE NUMBER: Patrick Dunn, 980-373-1164, Patrick.Dunn@Duke-Energy.com Ryan Czop, 980-373-2779, Ryan.Czop@duke-energy.com FACILITY CONTACT ADDRESS: Same as above PARTICIPANTS: Shawn McKee – NCDEQ, Solid Waste Section Elizabeth Werner - NCDEQ, Solid Waste Section Larry Frost - NCDEQ, Solid Waste Section David Giachini - NCDEQ, Solid Waste Section Patrick Dunn - Duke Energy Ryan Czop - Duke Energy Scott Saunders - Duke Energy Chuck Cranford – Duke Energy Scott Nordgren – Duke Energy STATUS OF PERMIT: Permit to Construct, Phase I, issued 6/4/2009 Permit to Operate, Phase I, issued 9/7/2012 Permit to Construct, Phase II, issued 9/17/2012 Permit to Construct, Phase II modification, issued 3/19/2014 The Permit to Operate, Phase II, Modification issued June 13, 2016 shall expire September 7, 2020 The Permit to Construct, Phases III and IV are being prepared by Wood. The Section expects submission in February 2019. PURPOSE OF SITE VISIT: Comprehensive Site Inspection STATUS OF PAST NOTED VIOLATIONS: None. OBSERVED VIOLATIONS: None. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 2 of 2 ADDITIONAL COMMENTS The facility is an industrial landfill permitted to receive "Coal combustion residuals" including (but not limited to) fly ash, bottom ash, boiler slag, mill rejects, and flue gas desulfurization residue produced by a coal-fired generating unit destined for disposal generated by any Duke Energy Corporation facilities, as well as geotextiles used in the management of coal combustion products, and vacuum truck waste. The Permit to Operate shall expire September 7, 2020. 1) The facility permit, site plan, and operations plan were discussed during the inspection. Routine operations occur during daylight hours (usually from 7am – 3pm or later as needed). 2) The facility is operated by Charah, Inc. which is responsible for hauling materials to the landfill, daily operations of the landfill, and conducting other associated activities. Charah, Inc. personnel are responsible for daily landfill operations; certified staff are always present when the landfill is in operation. Annual Landfill Operation Plan Training occurred on April 19, 2018. The following Charah personnel are NC Certified Landfill Managers: Walter Fox, NC Manager of Landfill Operations, 13-02M-00092, expires 9/20/19 Chris Emory, NC Manager of Landfill Operations, 13-02M-00079, expires 7/24/19 Charles Bridges, NC Certified Landfill Manager, 17-02M-00306, expires 6/15/20 Camron Smith, NC Certified Landfill Manager, 16-02M-00197, expires 10/14/19 Sam Byrd, NC Certified Landfill Manager, 13-02M-00093, expires 9/20/2019 Ronald Ramey, NC Certified Landfill Manager, 18-02M-00393, exp. 9/6/2021 3) The leachate collection system consists of a geocomposite drainage layer and pipe network to convey leachate to sumps located in each landfill cell. Leachate is pumped from the landfill sumps to a lined leachate basin. From the basin, the leachate is pumped to an existing plant NPDES permitted ash basin located to the northeast of the landfill and is incorporated into the plant’s treatment system. Records of the liquid levels in the leachate collection system were not available at the time of the inspection but were subsequently electronically sent to the Solid Waste Section. Readings are currently being recorded on a weekly basis. Given that § 130A-295.6. (h)(2) states A leachate collection system shall be designed to return the head of the liner to 30 centimeters or less within 72 hours. The design shall be based on the precipitation that would fall on an empty cell of the sanitary landfill as a result of a 25-year-24-hour storm event.... The Department may require the operator to monitor the head of the liner to demonstrate that the head is being maintained in accordance with this subdivision and any applicable rules. The Section recommends the following updates to the recordkeeping:  LCS records are hand written; recording them electronically would improve legibility. The facility should create a comprehensive electronic spreadsheet for the data collected in the last 12 months, for the landfill operation Phases 1, 2, leachate basic and any other pertinent leachate information. The presentation of data should be easily understandable or explained in a comments section. The spreadsheet currently being used at Mayo, which includes levels, flows, etc., would be a good template. The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 3 of 3  Records should clearly indicate the leachate level on the liner in addition to the total depth of liquid recorded in the sumps.  Time between recorded readings should be no more than 72-hours to demonstrate that the head on the liner is being maintained below statutory requirements. 4) The camera inspection of the LCS was completed 7/26/2018, issues were noted. 5) Weekly logs of rainfall events and landfill inspections for erosion & sediment problems were reviewed during the inspection. Permit dated 3/16/2009. 6) Dust control records were reviewed during the inspection. They were well organized and appeared to be complete. 7) The facility has an active stormwater permit which expires on 9/30/2020. Self-inspections are up to date. 8) Monthly density records were reviewed during the inspection. They were well organized and appeared to be complete. 9) Vacuum Truck records were reviewed during the inspection. They were well organized and appeared to be complete. No issues were noted. 10) Between January 1, 2018 and December 31, 2018, a total of 45,309.37 tons were landfilled in Phase I and 267,275.08 tons were landfilled in Phase II. The top of Phase 1 is currently being used for FGD storage (per Section approval). A net of 7,640.28 tons were added to Phase I during 2018 and 36,777.72 tons were reclaimed to be used in wallboard manufacturing. Phases 3 and 4 are have a tentative construction date in 2019 pending a Permit to Construct. 11) No ash was being received from other facilities at the time of the inspection. Unit 5 was not operating at the time of the inspection. Unit 6, which is duel fuel unit next fall (gas and coal), was operating using coal. 12) Basin 1-4 – excavation is complete and wastewater treatment and retention basin system is nearing completion where the basins were previously located. 13) Financial assurance documentation for the facility was reviewed during the inspection. The financial assurance was submitted by Duke Energy Carolina on March 26, 2018. The approved financial assurance includes $4,847,922 for closure, $1,995,161 for post-closure care, and $2,000,000 for potential assessment and corrective action. 14) Samples from groundwater monitoring wells MW-1S, MW-1D, MW-2S, MW-2D, MW-3S, MW-3D, TW-1S, TW-1D and TW-2 are collected semi-annually and analyzed for the Appendix I constituent list. Surface water samples are collected from two locations (SW-1 and SW-2) from Suck Creek which is south of the landfill. Sampling was last performed on October 16, 2017 and April 24-25, 2018. 15) The edge of waste is identified with permanent markers which are yellow and are being well maintained. The edge of liner markers on the outside perimeter of the landfill are on the top of the perimeter berm, 6.5-ft. outside of the actual edge of waste. Edge of waste markers are placed on top of the interior berms that separate each of the cells. 16) The perimeter stormwater ditches are free of exceisive sediments and are well maintained. 17) The access roads for the landfill are well maintained. 18) There was no evidence observed during the inspection of any leachate seeps or breakouts on the landfill. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 4 of 4 Vegetation on the side slopes of the landfill was well established and was being well maintained. 19) The top of Phase 1 (gypsum storage) appears to have had no attention since the last rain event. Regular inspection of Phase I, repairs to erosion riles, chimney drain surroundings, dust control, should be done routinely. 20) Phase 2 (active ash area) appears to be well maintained. Dust is being well controlled in the active areas of the landfill. Water trucks not in use at the time of the inspection because it was actively raining. Active waste placement in Phase II. Bottom ash berms surrounding chimney drain. 21) Trucks leaving the landfill wash exit through a wheel wash manned by staff using powerwashers to remove ash from the sides of the trucks. 22) There was no evidence of significant ponded water on the landfill though recent rain was still evident. Grading in all active areas appeared to be sloped towards the chimney drains and into the leachate collection system. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 5 of 5 Please contact me if you have any questions or concerns regarding this inspection report. _ Phone: 919-707-8284 Shawn McKee Environmental Senior Specialist Regional Representative Sent on: February 11, 2019 Email: X Hand delivery US Mail Certified No. [ _] Copies: Ed Mussler, Section Chief, Solid Waste Section Jason Watkins, Field Operations Branch Head, Solid Waste Section Elizabeth Werner, Permitting Hydrogeologist, Solid Waste Section Larry Frost, Engineering Project Manager, Solid Waste Section David Giachini, Engineering Project Manager, Solid Waste Section