Loading...
HomeMy WebLinkAboutMO-6731_27502_G_NORR_20180911_NORRROY COOPER Governor MICHAEL S. REGAN Secrerary MICHAEL SCOTT Director Service Distributing Company, Inc. Post Office Box 310 Albemarle, NC 28002 Attn: Robert E. Gresham Dear Mr. Gresham: NORTH CAROLINA Environmental Quality September 11, 2018 Re: Notice of Regulatory Requirements 15A NCAC 2L .0407(b) Risk -based Assessment and Corrective Action for Petroleum Underground Storage Tanks Servco No. 00311 24 North Church Street, Concord Cabarrus County Incident Number: 27502 Risk Classification: High The UST Section, Division of Waste Management (DWM), Mooresville Regional Office (MRO) received the July 19, 2018 Groundwater Monitoring and Corrective Action Performance Reports on July 24, 2018. The reports recommending shutdown of the remediation system at this time, continued semiannual groundwater sampling, and an evaluation of overall plume stability and associated risk to potential receptors be conducted based on the results from the next sampling event (November 2018) was reviewed and approved on September 5, 2018. The paper report copies will be maintained in the MRO. The electronic copies have been loaded to the DWM's electronic document storage system (Laserfiche). The report states: • The results of the laboratory data indicate that the groundwater sample collected from monitoring well MW-IOR was above NCAC 2L standards for benzene. The laboratory analysis further indicates NCAC 2L standards for ethylbenzene and total xylenes were exceeded in the groundwater sample collected from MW-IOR and for naphthalene in the groundwater samples collected from MW-8 and MW-IOR. MTBE exceeded NCAC 2L standards in the groundwater samples collected from MW-9 and MW-IOR; and PCE exceeded the NCAC 2L standard in samples collected from MW-2, MW-4, MW-5, MW-7, MW-9 and MW-12. None of the groundwater samples collected indicated any constituents exceeding Gross Contamination Levels (GCLs). No free product was measured in the gauged monitoring wells during the June 2018 sampling event. E cew 0- f NORTH CAROL!NA� � unry of EmlmmYeHsl 9� r North Carolina Department of Environmental Quality I Division of Waste Management Mooresville Regional 0Mce 1 610 East Center Avenue, Suite 301 1 Mooresville. North Carolina 28115 704.663.1699 • Review of the current data indicates that the predominant groundwater flow at the site is in a northeasterly direction. • Based on previous receptor surveys completed by ECEA, there is one water supply well utilized for irrigation purposes only and located within 250 feet of the subject property. In addition, according to the USGS, the closest surface water body appears to be an unnamed tributary of Three Mile Branch located approximately 500 feet north of the subject property. It appears the surface water is classified as class "C" surface water. Based on the presence of the irrigation well located within 250 feet of the source area, the site is ranked as a "High" risk site. • The soil and groundwater remediation system, consisting of a soil vapor extraction and air sparge system was started on June 28, 2010. The SVE and AS systems were down during the January and March site visits due to electrical issues. The system was operational during the June site visit, but is currently down due to broken belts. The system is currently down awaiting new belts. Based on recovered vapor sampling results, approximately 3.35 pounds of vapor phase hydrocarbons have been recovered. • Current laboratory analytical data indicates that overall dissolved phase hydrocarbon constituents (primarily BTEX and MTBE) continues to occur at the site and are decreasing with some seasonal fluctuations. Remaining constituent levels exceed NCAC 2L standards at multiple locations for various constituents. Per this Notice of Regulatory Requirements: • Continue sampling monitoring wells on a semi-annual basis (next sampling event November 2018). • The remediation system can remain off at present. The operational status of the remediation system will be revisited after the next report review. • The next report should include an evaluation of the overall plume stability and an evaluation of risk to potential receptors. • The next remediation monitoring report is due no later than November 30, 2018. If you have any questions regarding the actions that must be taken or the rules mentioned in this letter, please contact me by email at Trudy. Beverl ncdenr.gov or telephone at (704) 235-2182. Sincerely,,, / Trudy Beverly, L.G. Hydrogeologist Mooresville Regional Office UST Section, Division of Waste Management, NCDEQ cc: Mike Stanforth & Donna Farris, Excel Civil & Environmental Associates, PLLC (via email) Mike Downs, Cabarrus County Manager (via email) NORTH C.4R0.'+1A�E Q� uf F, r,nn eHs 9Nor North Carolina Department of Environmental Quality I Division of Waste Management Mooresville Regional 0Mce 1 610 East Center Avenue, Suite 301 1 Mooresville. North Carolina 28115 704.663.1699 Beverly, Trudy From: Beverly, Trudy Sent: Tuesday, September 11, 2018 2:39 PM To: Mike Stanforth (mstanforth@excelengr.com); Donna Farris (dfarris@excelengr.com) Cc: 'MKDowns@cabarruscounty.us' Subject: Servco 311 - UST Incident #27502 Attachments: MO-6731 _27502_G_NORR_20180911 _NORR.pdf Mike and Donna, Please see the attached Notice of Regulatory Requirements letter for Servco 311 located at 24 North Church Street in Concord, Cabarrus County. Trudy Q�5 Trudy Beverly, L.G. Hydrogeologist, Division of Waste Management North Carolina Department of Environment Quality Underground Storage Tanks Section Corrective Action Branch Mooresville Regional Office (704) 235-2182 (Office) Trudv.Beve rlv(@ncdenr.gov Er7k' d Cprr85'porOiar7 to and from this aGdresS iS subject to the Noah CaralOa Pubko Records Law anal rr;ay be d obscd to third parties. Branch's Underground Storage Tanks Website Address: https://deg.nc.gov/about/divisions/waste-management/ust Branch's Above Ground Storage Tanks Website Address: https://deg.nc.gov/about/divisions/waste- management/ust/ast-program INTERACTIVE MAPS WITH DWM SITES AND PERMITTED FACILITIES: https://deg.nc.gov/about/divisions/waste-management/waste-management-rules-data/waste-management-gis-maps File Review Procedures: https://deg.nc.gov/about/divisions/waste-management/ust/file-review-procedures#mooresville-regional-office ONLINE ACCESS TO UST SECTION DOCUMENTS (Laserfiche): https://edocs.deg.nc.gov/WasteManagement/Search.aspx Document Submittal & UST File Names for Laserfiche Policies: https://files.nc.aov/ncdea/Waste%20Manaaement/DWM/UST/Corrective%2OAction/Electronic%2ODocument%2OSubmi ttal%20Memo%20Update.pdf https://files.nc.eov/ncdea/Waste%20ManaLyement/DWM/UST/Corrective%2OAction/UST%20file%20names%20for%20 Laserfiche.docx