HomeMy WebLinkAbout3506_BrantleyCompost_Inspection_20180616t;a Waste Management
ENVI RON MENTAL QUALITY
FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
UNIT TYPE:
Lined
LCID
YW
Transfer
Compost
X
SLAS
COUNTY: FRANKLIN
MSWLF
PERMIT NO.: SWS-3506-COMPOST
Closed
HHW
White
Incin
T&P
FIRM
MSWLF
goods
FILE TYPE: COMPLIANCE
CDLF
TireT&P/
Tire
Industrial
DEMO
SDTF
Collection
Monofill
Landfill
Date of Site Inspection: June 16, 2017
FACILITY NAME AND ADDRESS:
David Brantley & Sons, Inc.
37 Pine Ridge Road
Zebulon, NC 27597
Date of Last Inspection: August 12, 2015
GPS COORDINATES: N: 35.92656 o W: 78.25294
FACILITY CONTACT NAME AND PHONE NUMBER:
Name: Shane Brantley, Owner/Operator
Telephone: 888-817-1904, Cell 919-669-5187
Email address: davidbrantleyandsons(&yahoo.com dbsonsl@gmail.com
Fax: 252-478-4644
FACILITY CONTACT ADDRESS:
Same as above
PARTICIPANTS:
Mary Whaley, NCDEQ, Solid Waste
Shane Brantley, Owner, Operator
STATUS OF PERMIT:
The permit was issued on March 22, 2012. It is a Small type 3 compost facility. The permit expired on March 22,
2017, the permit application was submitted to the Raleigh office in February, 2017.
PURPOSE OF SITE VISIT:
Comprehensive inspection
STATUS OF PAST NOTED VIOLATIONS:
NA
OBSERVED VIOLATIONS:
None
The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance
with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an
administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit,
or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to
enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any
such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules.
Page 1 of 5
FACILITY COMPLIANCE INSPECTION REPORT
Waste Management ENVIRpN MENTAL QUALITY Division of Waste Management
Solid Waste Section
ADDITIONAL COMMENTS:
1. This facility is a Small Type 3 facility and 15A NCAC 13B .1402 (f)(6) states "Small facilities are those that
receive less than 1000 cubic yards of material for composting per quarter, and occupy less than two acres of
land". Shane Brantley is looking at accepting more grease trap waste and knows that if he is getting close to
the 1000 cubic yards of waste/ per quarter, that he must submit an application to the Section to become a Large
Type 3 facility.
2. 15A NCAC 13B .1408 (b) Record Keeping: All facility owners or operators shall record and maintain records
for a minimum of five years. Records shall be available for inspection by Division personnel during normal
business hours and shall be sent to the Division upon request:
(1) Daily operational records must be maintained, which include, at a minimum, temperature data (length of the
composting period) and quantity of material processed;
(2) Analytical results on compost testing
(3) The quantity, type and source of waste received;
(4) The quantity and type of waste processed into compost;
(5) The quantity and type of compost produced by product classification; and
(6) The quantity and type of compost removed for use or disposal, by product classification, and the market or
permitted disposal facility
3. There were just a few unacceptable waste materials including plastic bottles and other misc. plastics, in the
wood chip pile and the working windrow. Remember to remove waste on a frequent basis and dispose of
properly.
4. The whole compost site should be mowed on a regular basis, including the 100 foot property line buffer areas,
in order to facilitate the inspection.
5. It is recommended that the soil on either side of the concrete pad, where the leachate has flowed, be
incorporated into the active windrow on a more frequent basis. These dates should be included with the
dailv log. This was not observed on anv of the logged notes. This was stated in the previous inspection
report.
6. Easily visible permanent markers must be established to show the boundaries of the waste area for the
compost operations. This was commented on in the previous report and markers were still not observed.
7. Insure that a minimum of 25 feet, for emergency vehicle access is maintained around the site. There were
mounds of soil that could possibly obstruct emergency vehicles from getting around the site. It is
recommended that completed piles of compost, that have been sampled and test results were acceptable, be
moved to another area of the property.
8. There were broken down trucks and tanks stored within the buffer area of the site, which must be removed to a
location other than the permitted compost facility.
9. The access road was in good condition.
Please contact me if you have any questions or concerns regarding this inspection report.
Page 2 of 5
t;a Waste Management
ENVI RON MENTAL QUALITY
Environmental Senior Specialist
Regional Representative
FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
Phone: 919-693-5023
Sent on: June 27, 2017 X Email Hand delivery US Mail Certified No. 1j
Copies: Drew Hammonds, Eastern District Supervisor - Solid Waste Section
Jessica Montie, Compliance Officer - Solid Waste Section
Wood chips for mixing with waste
Page 3 of 5
Mixing pad
FACILITY COMPLIANCE INSPECTION REPORT
Waste Management ENVIRpN MENTAL QUALITY Division of Waste Management
Solid Waste Section
Page 4 of 5
FACILITY COMPLIANCE INSPECTION REPORT
Waste Management ENVIRpN MENTAL QUALITY Division of Waste Management
Solid Waste Section
Windrow of mixed wood chips and grease trap waste