Loading...
HomeMy WebLinkAbout1203_Burke_JohnsRiver_CDLF_MSWLF_LFG_FID1261709_20181204ENR USE ONLY: ❑Paper Report ❑Electronic Data - Email CD data loaded: Yes / No Doc/Event #. NC DENR I IEnvironmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Joyce Engineering Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Samantha Slebodnik E-mail: sslebodnik@joyceengineering.com Facility name: Johns River Waste Management Facility C&D-over-MSWLF Phone: (336) 323-0092 NC Landfill Rule: Facility Address: Facility Permit # (.0500 or .1600) 2500 Marsh Trail 12-03 .1600 Morganton, NC Actual sampling dates (e.g., October 20-24, 2006) December 6, 2018 Environmental Status: (Check all that apply) Initial/Background Monitoring ❑ Detection Monitoring Assessment Monitoring ❑ Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells ❑X Groundwater monitoring data from private water supply wells ❑ Leachate monitoring data 1-1Surface water monitoring data Methane gas monitoring data Corrective action data (specify) Other(specify) Notification attached? e No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. G. Van Ness Burbach, Ph.D., P.G. Technical Consultant (336) 323-0092 Title 2211 W. Meadowview Rd., Ste. 101 Greensboro, NC 27407 Facility Representative Address C-0782 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 (Area Code) Telephone Number Affix NC Licensed/ Professional Geologist Seal �oQ' JC,�FEI 9 SF L j349AIESS U 461LI I ` E1\JGINEEF111\1G December 13, 2018 Mr. Miles Champion Burke County General Services Director/County Engineer P.O. Box 219 Morganton, NC 28680 RE: Burke County, Johns River Landfill Permit Number 12-03 Fourth Quarterly Landfill Gas Monitoring Report of 2018 Project No. 2180009, Phase 04 Dear Mr. Champion; 2211 West Meadowview Rd. Greensboro, NC 27407 tel: 336/323-0092 fax: 3361323-0093 www.JoyceEngineering.com On behalf of Burke County, North Carolina, Joyce Engineering (JOYCE) is submitting the attached methane monitoring results for Johns River Landfill, Permit Number 12-03. The 2018 fourth quarter landfill gas monitoring event was performed on December 6, 2018. During this event, gas probes GP -IS, GP-lD, GP-2S, GP-2I, GP-2D, GP-4, GP-5, GP-6, GP-7, GP-8 as well as gas monitoring points GMP-1 through GMP-14, were monitored in accordance with the facility's Landfill Gas Monitoring Plan. GP-3S and GP-3D were abandoned in February 2018 for construction of new landfill Phases 2A and 4. The locations of the gas probes and monitoring points are depicted in Drawing 1. The monitoring data for the gas probes and buildings are summarized in the attached Landfill Gas Monitoring Data Logs. Methane was detected above the lower explosive limit (LEL) in gas probes GP-2S, GP-2I, GP-2D, and GP-4. Gas probes GP-2S, GP-2I, and GP-2D are a nested set and are located in close proximity to waste in the old C&D-over-MSW landfill. None of these probes are considered to be boundary probes. The concentrations are similar to those detected during previous events. No exceedances were recorded for any of the other probes, monitoring points, or structures. The methane detections and exceedances are summarized in Table 1 and Table 2, respectively. We have included an EMRF and will forward a copy of this report to Jaclynne Drummond with the NCDEQ Solid Waste Section. This report should be added to the facility's records. The next quarterly monitoring event is tentatively scheduled for the first quarter of 2019. If we can provide any additional information please do not hesitate to call me at (336) 323-0092. Mr. Miles Champion December 13, 2018 Page 2 of 2 Sincerely, JOYCE ENGINEERING Samantha Slebodnik Environmental Field Technician Attachments: Environmental Monitoring Reporting Form (EMRF) Tables 1 & 2 Landfill Gas Monitoring Logs Site Map with Gas Monitoring Locations — Drawing 1 cc: Jaclynne Drummond, NCDEQ vLJ i iG ENGINEERING Burke Co. - Johns River Landfill Permit #: Monitoring Date 12-03 12/6/2018 Table 1: Methane & Hydrogen Sulfide Detections LFG CHa CHa H2S Probe (%Vol.) (%LEL) (%Vol.) GP-2 S 58.7 1174 0 GP-2 I 57.6 1152 0 GP-2 D 57.1 1142 0 GP-4 39.6 792 0 Table 2: Methane Exceedances of the LEL LFG CHa a Probe (%Vol.) (%LEL) GP-2 S 58.7 1174 GP-2 I 57.6 1152 GP-2 D 57.1 1142 GP-4 39.6 792 Notes: CH4 = Methane. H2S = Hydrogen Sulfide. %Vol. = Concentration in pecent-by-volume. %LEL = Concentration as a percent of the LEL. LEL = Lower Explosive Limit = 5%Vol for Methane. GP = Gas Probe, permanent installation. S = Shallow Screen. I = Intermediate Screen. D = Deep Screen. TGP = Temporary Gas Probe for delineation study. BOLD = Exceedance. Burke Co., Johns River Landfill Permit # 12-03 Joyce Engineering \C Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form entire: T7lt, f,Pn1 aPd alrl 117f 1.17•It 1 7 -_� 17 .11L' n:fl'.' 'Plll-IlC "I a1 LI 10hle Ior nuPrClent all I _ -a rr n:rlrr-en bi CM n UP13,17 eq',,st ! N ._ r2; < < Slalut, FacilitN Name: OUrb— Cc,, oy✓+ 5 I�IU�r" I Z - o 3 Permit \umber. Sampling Date: r�� Z(1lg \C Landfill Rule (.0500 or.1600). i(0oo Sample Collector\ame& Position: �, �IesUhea -CNU rield Iechn;ciGtrtjebodVli -iC�� `eLhnrC1(nl Gas deter T} & Serial \umber. C'tEM 5cco I SUS y q pe -- L f Gas %leter Calibration Date 014. 120 1 S Field Calibration Date& Time: IZ1S/ 0 0 ) e @ 0500 Field Calibration Gas Type (15 I i or3- - is� c 151,Cn Field Calibration Gas Canister Expiration Date: Oq /Zvz I Gas NIL -ter Pump Rate: 300 wt L mi 1ef#: g352 ��j 29 Ambient IirTemnt perare: U S Barometric Pressure (in nr mm H_c): 17�%eatherCondition,: 5U,,*1(1V -i-• ZQ i5 Instructions: Crider "Location or LFG %t ell'-. list monitoring hell = or describe monitoring location (e.g.. inside field office). Attach a test location map or drak%ing. Report methane readings as both °o LEL and °o CFf4 bt tolume. Conk ert 9,, C H4 (bt rolun7e) to % I_F_L as follotts: % methane (by volume)/20 = % LEL. ` rtfrotuen Sul fide (H2S) lacts lllonifol'ilh Illgt be requirecl %Ot' ('077sIr11clion R Demolition LWhIfYIS /('/)I f,v) SC'e UICIA'ld7ttll Permit conditions C710 Or % acilllt I VG monilonlf , plan L O�it L FG "t, -11 ID Tube Purge rime ,r Day Pumped (,Cc) °Initial LFl SnahiIve: LFl C114 I olumr) „ p 0 °° CO2 olL;mcr I olumr) C-�P- I S C-lP- i O�oi 60 O. o O, o D, O 13. 2 S 1 ' —b�l' 78.E r•es: _ p-o9 Ogo� O ao ao ao -tMP-s O�o'� &0 0, o ej, 0 0,0 I(O.S 0,3 �- bal:g, z -- $o� ao o o (�, 19.o 0,2 ,6. 7 oSo7 &O o,o 0o o.v ►9,► O — � .0 Op- 08Sy B000o©.0 .6ba), z Y 0912 &O O,o c�,o O.o Zo,Coo 0,0 D0 C), � ZI.� d.I d93� 1 &0 0.0 D, 0 O. U Z1 09,7 00 D d (�.0 2z.o O, i - 9Iii C��l -11 IZSS �O on o.o o, 0 21,W O.t „s; — 11:78s — P 62 Coo ( 0 7 2 3q. (o 0 , S �/. s s. --- bell:zg 0S ut t ii nee.le,1 attach addnronal ,ICrtu fw-ni; to I-lude addntonal LFG ntomiornkz data locations f w the fctctlrn A( rioN LF \ F is Methane >1.2i% b% tolunie (inside structures) .-A\D >S",'. bt tolume (at facilit% bonndart ) 11%droizen Sulfide: >1 % b} tolume (inside structures) AND >4% by tolume (at facilitt boundart ) Certification To the best of m� knms ledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making an% false statement, representation, or certification including theJ�possibilith of a fine and imprisonment. S[GN.ATC RE l ��- TITLE Rewsed—March 6 2017 ,IoS a, rWni}o r-d ouTst dt_ \C Division of Waste Management - Solid «ante Section Landfill Gas Monitoring Data Form %otice: 7171sr.rrrr _rrd nrrt 3tr.a ha:l ro rt crra "Purtl, Pd, nr.l, 'crs da rre,l rrr \! c, rr_ r o S1 It , l '-1 a rr _ it n _ l - at_riohlalbrrnspdcnoanndac.nnnraaanl+tantparsontq,o+rr•aq4astr\('i1>rr2,� Sr7r1r;_!:_'-6 Facility Name: u(_ CIO _:30 f\5 Lvee it Number 12 —03 Sampling Date: �ZD�� \C Landfill Rule ( 0500 or.1600). - Q000 Sample Collector\ame&Position: KMesu,W-�NV Fig Iechn,citx lfS, ����{ nik"F�tLt' f";eld ie[�,(liCi�r� Gas Teter Type R Serial Number: C-TC-M SZ�OD���75/yq Gas Meter Calibration Date: 07 Zo 1$ Field Calibration Date & Time: 6 Field Calibration Gas Type I l5 15 or3; 50l: I:5�/CF( /S/. -0 Field Calibration Gas Canister E\piratioln Date: r� b2� Gas deter Pump Rate: 3D1� LIMi !OT # : %35 Z 3 t Ambient 1irTemperature: 2O5 Barometric Pressure (:n urmm I[g): M 17 �teatherConditions: 2015 4-SUf1fj Instructions: L ndor"Location or LFG �t ell". list monitoring \ell = or describe monitoring location (e.g.. inside field office). -attach a test location map or dra«in,. Report methane readings as both °o LEL and °o CH4 b\ volume. Con%ert 3%, (•Ha (hi rohrnre) to °-, I0.. as follo�%s: % methane (bN %olume),'20 = % LEL. 'Hydrogen Suyllrle (H2S) ally t?101111017 . IV nun be required for Cntz,tructicttr K Uenrohtion Landfills I('OLFer 5' e 11011 iclual permit C'onditians Ulld or FcrC•ilr)t If G ntnnituring plun L ocati„n or L F(, 11 zli IU rmpl: Tuhe Pur_o T:me of Da% Time Pumped I,CCI Initial Lt-L Stahil,zed °° LFL °� CFI4 (tnlume) U, °, CO-, — ° \lsiL ti ' Itoiel um ttulumc� m (toluci i r� ,t(Y�) 133-7 (o0 0.0 ll�iZ S7.► 01 JJA,I --- %1;Z.7 :to, oG t-tQ Z5(si Ivey GO 0,0 117 5 -6 7 O. O 5? 2 bal: Z.I f335 CQO 0,0 I ISZ e;?.. D, o yD G P- s Jq03 (0 0 ©. 0— (0 0 Q 00 Z0,Q 1 1,3 6'MP-2 Y Iqm, (00O,0 z —ball ;7s,s Cz -7 1�109 (00 O,0 0,C) ©, lg,Z 3,.7 — al:79,1 pes, o.o CAP-8 ly lz (o O. 0 0,0 0,0 18, g ), ,3 --9.5,e5., fi 0.0s 6MP--3 (oo go f� o 0 21. �. ► � h 1 , 7Y y -- i C�M1Q- y Y J SY 3 (00 O, o 0. D U,. o Z1, s o, I res., - �� 7� � — CT�I - J Y I ss � o D. 0 0, � �. O Z1, s O. ► _ ibq Is 79', y — L�Nc -1 1(0 o O. 0 0.0 ©. 0 21. q 0,1-- -, . � •� „�_,<<, �,,,..�„ u,nrnrt/uur ucrnr rornrs ra nrcnrne ud.rnwrral Lf•G monrta urg data locutions Jnr r)ra jcrcrlrn V rio,, L1 F I Methane >1.25% by %olume (inside structures) .AND »"S, b\ %olume (at facilit} boundan ) Fkdroaen Sulfide: >1% bl. %olume (inside structures) AND >-i'ib b} volume (at facility boundar<) Certification To the best of my knois ledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aicare that there are significant penalties for making and false statement, representation, or certification including the possibilih of a fine and imprisonment. SIGN.ATCRE TITLE Revised —March 6, 2017 1i / �\x PROTECTED AREA 01 �eoaAow'L1,2 GOOD; � -Zzx�z PZ-24 CAR BOAR ------ \k _VTION�� t\> SHOOAN_?_� \ I Z-10 \ \\� MW-3 —c OIL BATTERIES CAR OARD / l � \ 1 FACILITY LIMIT- 7 \ -\ _ ' E//HOUSE STREAM S-4 �� \ SC -AC 0, ^ \ ��lp STE O /I MIT I O , \\-21 \ / GA o-- fVIW- 0 \ \ / Y WASTC� \ - -\ / OPOSED ASTE LIMIT GP- GMP-2 � � o -3 P-7 GOODS / _� ` \ \ �� WETLAND W3 / \ /4� GMP-4 / f PZ-3 90 ,080000 IULCH AND nn ccE �A GP-8 / / \ � PALLETS �P 2 � � � PZ-5 `/ P 37 1080 Y / \ Y BOUNDARY / \ / � FACILITY � O P -32 \ PROPERTY LINE (TYP I L N E /�B \/ �- + I :: / \ / PR / B P ASE T SE 5 080— EDGES / WEST AND SOUTH ) TBA PZ-20 \ \ \ PHASE 1B ,0 � ��ETERY I MW2 Z-42 NLE PZ 1 TBA BA / I \ OD ` MW 22S SE 4 1 060 � PZ-34 / / P -1 \ PHASE 8 I / \ GP-3 A / .- / l,llllll I/ GP-2 _ / W Z-34 NLE \ \ \ \_ � � f J / - \ B PHASE 2 � / V- 1 I \� \ *. 4v loso I � � � / STREAM S-2 / � 'gyp GV-02 MW-38 Z 23 I S 3 / E PZ-19 \ p3 STREAM / / O / GV-03 0 _ \ \\ / z / G / 0 YR FLOOD IMIT / 10 EXISTING PHASE 6 / ° ELEV. 1005.0 \ / / WASTE LIMITS - P _ 2 o J \ / / �, o P AS� 3 / 7 MP- "" PHAS PZ-17 PZ- 1 \ I/ 1 1 \ I -14 PZ-18 P LANI!PW1 NLE \ O �1 T EA� A J ` / \ (CP ES LANDFILL \)ISPO arAREA , ° \_ WETLAND W2 -g° -9 � URRENTLY EING CLOSED) / TING i � P-11 ` EDI IN mol il � 1100 CEMETERY - -1070� _ / / — I / / GV-03 Q GAS VENT _9 � PROTECTED MW-12� \ GMP-12 � GAS MONITORING POINT t� � / AREA _1030 /\/ GP-4 GAS MONITORING PROBE (EXISTING) \\0 �MW-MW-16SI / GP - / l� 7 GAS MONITORING PROBE(PROPOSED) / I VE"m / �,40 TBA TO BE ABANDONED FOR CONSTRUCTION / OF PHASES 2A AND 4 �. PZ-12 PIEZOMETER z� / GPMW-12 MONITORING WELL Q 0 MW 18 MW 19 / 0 SMP-6 SURFACE WATER SAMPLING POINT AB =ABANDONED NLE = NO LONGER EXISTING (PRESUMED DESTROYED) GRAPHIC SCALE 0 100 200 400 (FEET) Y U m O z w U) U) LL O 0 O U w 0 z z 0 L0 w w w Q 0 > >>00 .L w 0 0LLI 5 LL, w0> z z �r in Q w w Q w = w O O U Q Q O o v VV0 Q ti 00 jZ N� w�z � � W � �0 -, U W OoM J °-' zQmM �zz Q � w O U U U �0w z Z W N Cl Z LL �o Z� wQ �U �w = V Q z� CQ z G F_I— Q D 3:O O�U m Z 2 O z Q J V Jz LL 0� 00 Z Q J z O 2 PROJECT NO 277 SCALE AS SHOWN DRAWING NO. LGMP-01 0 ca J 0 0 c� J z Q J w 0 z Of O z O 2 U) /Q V 0 CD J W Q 0 CD J U W O Of CL N C 0 U 0 Y m J