Loading...
HomeMy WebLinkAbout1201_Burke_Kirksey_MSWLF_LFG_FID1261675_20181203�ENR USE ONL:Y�± [:]PaperReport []Electronic Data - Email CD (data loaded: Yes / No) Doc/Event #: 'NC DENR Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Joyce Engineering, Inc. Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: G. Van Ness Burbach, Ph.D., P.G. E-mail: vburbach@joyceengineering.com Phone: (336) 323-0092 NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or. 1600) October 20-24, 2006) Burke Co. - Kirksey Dr. Landfill Kirksey Drive 12-01 .0500 December 3-4, 2018 Morganton, NC Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring �X Detection Monitoring Assessment Monitoring Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells OX Groundwater monitoring data from private water supply wells Leachate monitoring data ❑ Surface water monitoring data Methane gas monitoring data Corrective action data (specify) Other(specify) Notification attached? e No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. ❑X Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points. dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. G. Van Ness Burbach, Ph.D., PG Sr. Technical Consultant (336) 323-0092 ignature 2211 W. Meadowview Rd., Ste. 101 Greensboro, NC 27407 Facility Representative Address C-0782 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 (Area Code) Telephone Number Affix NC Licensed/ Professional Geologist Seal a°,#'T CARO-�y' SEAS 1349 � G GFOLOG�`� �`'%...NESS ■..I&J 1 E1\3INEEF?11\1G December 13, 2018 Miles Champion, PE General Services Director / County Engineer Burke County P.O. Box 1486 Morganton, NC 28680 RE: Burke County, Kirksey Drive Landfill Permit Number 12-01 Landfill Gas Monitoring Report — Fourth Quarter 2018 Project No. 2180009, Phase 04 Dear Mr. Champion; 2211 West Meadowview Rd. Greensboro, NC 27407 tel: 336/323-0092 fax: 336/323-0093 www.JoyceEngineering.com On behalf of Burke County, North Carolina, Joyce Engineering (JOYCE) is submitting the attached methane monitoring results for Kirksey Drive Landfill, Permit Number 12-01. The 2018 fourth quarter landfill gas monitoring event was performed on December 3-4, 2018. During this event, JOYCE monitored gas probes GP-1, GP-2, GP-3, GP-4, GP-5, and GP-6, and two buildings (Burke County Animal Shelter and Friends for Animals building) in accordance with the Sherriff's office schedule. The approximate locations of the gas probes are depicted in Drawing 1. The monitoring data for the gas probes and buildings are summarized in the attached Landfill Gas Monitoring Data Log. Additionally, Methane detection and Lower Explosive Limit (LEL) exceedances are summarized in the attached Table 1 and Table 2. Methane was detected above the lower explosive limit (LEL) in gas probes GP-3, GP-4, and GP-6. There were no detections and no exceedances in either the County Animal Shelter or the Friends for Animals building, or the remaining gas probes. These results are consistent with previous results. We have included an Environmental Monitoring Report Form (EMRF) and will forward a copy of this report to Jaclynne Drummond with the NCDEQ Solid Waste Section. This report should be added to the facility's records. The next quarterly monitoring event is tentatively scheduled for the first quarter 2019. If we can provide any additional information, please do not hesitate to call me at (336) 323-0092. Sincerely, JOYCE ENGINEERING J Samantha Slebodnik Environmental Field Technician Mr. Miles Champion December 13, 2018 Page 2 of 2 Attachments: Environmental Monitoring Reporting Form Detection and Exceedance Tables Landfill Gas Monitoring Log Drawing 1 — LFG Monitoring Locations Map cc: Jaclynne Drummond, NCDEQ aJLJ r ENGlNEERlNG Burke Co. - Kirksey Dr. Landfill Permit # 12-01 Table 1: Methane Detections - December 3-4, 2018 LFG CH4 CH4 Probe (%Vol.) (%LEL) GP-3 34.1 682 GP-4 53.6 1072 GP-6 60.2 1204 Table 2: Methane Exceedances - September 28, 2018 LFG CH4 CH4 Probe (%Vol.) (%LEL) GP-3 34.1 682 GP-4 53.6 1072 GP-6 60.2 1204 Notes: CH4 = Methane. %Vol. = Concentration in percent -by -volume. %LEL = Concentration as a percent of the LEL. LEL = Lower Explosive Limit = 5%Vol. BOLD = Exceedance Burke Co., Kirksey Dr. Landfill Permit # 12-01 Joyce Engineering \C Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Votice: [III, r,rm _nrd nm urj�rnran-,r; a; t-; lra:l ra n and "Puhh Pr, ur"l,"us da a ;! ru 1l G rrdrar' Sr rt:u1 / '-/ a s st,. h r, _ f- r_ rn u�krf+(d tin• m;pdcuorr an.1 acarrrrnan,nr bs nrit p�rsnn :rra,r r-rqu,� sr r \"(' iienr"or 51anGe 1= _'-5, Facilit\ \ame:y('CD, r K�(� pr; + L Per �CQmit \umber: IZ — 0 1 Sampling Date: \C Landfill Rule (0500 or 16001: 005-Ou Sample Collector \ame & Position: rK, SUb —ENV 1'el�( lac an;�ian $. 1 — CNY F;e1d Te�hrl I C(et n Gas deter T\pz R Serial \umber. C7CM SWO ��111Gas deter Calibration Date: 0'112019 Field Calibration Date R Time: Field Calibration Gas T\pe I I 15 orii 50): Cd Field Calibration Gas Canister Expiration Date: og1zozl Gas Meter Pump Rate: M bin"./! Ambient \it - Temperature: 5 Barometric Pressure (in or ntm FI,,): «eatherConditions SAS -1-5v1trty Instructions: Under "Location or LFG \\ ell". list monitoring \\ell = or describe monitoring location (e._.. inside field office). .-attach a test location map or dra\\inQ. Report methane readines as both °o LEL and °o CH-1 b\ \plume. Com ert °b C'114 (hi "plume) to or, LFL as follm%s: % methane (by volume)/20 = % LEL. 'Hi -drug -en Sulfide (112S) g,r mnrritorit nxn he requirecila" C'on.str-trchinn d Demolition LCUHIfNs /(l)LFct rn,liridtral permit COMUthmS turf or Fctc'ilitt I VG mnniturir;, plun LAtltt,m or LFG \\"ell ID Sample rube Pure -rim,• of Da% Tame Pumped (,Cc) Inrual ', LFL stabilised LFI ° , U14 1%01UITICI "0,FI (�oi_une -- — -- — FL'S' (,olume) I CAP P-1 61P-�O 13675 I L I its 60 (o (0o 0.0 a o C), C) /07Z 0,0) C17o zOq 53, (w- 0.0 314. Z D• I 1Z-77 a � ZI.S f 114 twartis ,) _ d r,+ i,r Jos P, Obe- 7-fGS:r0.0 ns,ro.o w l . i I w r r rr nd,ded attain addittorra! cicrta (onus to nrclude additional LFG monnornr,; dartr 10Ca17anS fiW the rrcthn V r1o" LF\ I. I Methane- >1.25110 b% \olume (inside structures) AND »'!o b\ \plume (at facility boundan) Vl%drogen Sulfide: >1% b), \olume (inside structures) AND >4% b\ \plume (at racilit\ boundan I Certification To the best of m� kno\s ledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aisare that there are significant penalties for making an-, false statement, representation, or certification including the possibilit-, of a fine and imprisonment. — - - � tN v' �i�1d _ f ec�,✓t�CiGcr� ------ SIGNATURE TITLE Rewsed — March 6. 2017 rI C Dig ision of «aste Management - Solid Waste Section Landfill Gas Monitoring Data Form Nonce: 741,I•rm.mdam rr(jorn?cnrrrt_r1vch,2_lronare "PuP6c pe,,, d,'asdelur drn 1( t-e1121-m'5rc111112l='-1 4TSUL/r fh:,_ �.l-tnr-_rr,ne Cl! a l_rble J )r ntsp'?cncrn and = XOM nrr;,;rt bt am Per ,nrr lip 0+? requdsr r\'( i,enerar Strrure /?'-5 Facilit% \ame. gurL CD. F-1 rK�.Si;� Dr' � LF - Permit \umber: Sampling Date: 12- ILI 20 r \C Landfill Rule (.0500 or.1600): _ IZ-bI d-6Uv /S.Sleb �- N '1 Sample Collector \amecE Position: R.Mrr$!J rely �ecJ�,n,i:;an r?r E � Ff�.K1 T2%1fl;(_(C�f1 Gras deter Type R Serial \umber: C71-::M '--000 C7S-D-% 4 Gas Meter Calibration Date: ��7 O 1 S Field Calibration Date R Time: i Z�01 S" � 0;72�5- Field Calibration Gas TNpe H_5 I5 oi-i5 50):�S/.CA j,'/( Field Calibration Gas Canister Expiration Date: d�%/ZD2/ Gas \leter Pump Rate: �L M�- ;, - -a — mbient �irTemperature: 0.5i mni Barometric oriiH ):Cs� 9•9/ <veatherConditions: 3D"S"4`SUnrX, Instructions: Under "Location or LFG «ell' . list monitorin_ \Nell = or describe monitorin_ location (e.g.. inside Field office) .-attach a test location map or draNNing. Report methane readines as both °0 LEL and °o CH1 bN Volume. Com ert 4) ('1I4 (bt volume) to % LEL as folloNNs: % methane {bti -,olume)/20 = % LEL. 1111-drogen Sulfide (112S) Fits monilorirrg mat be required %a• CarslrvN;nn c; DNrr10/rl;vn l_andfr/ls rrrcliridual permit Conditions curd or rUCilrtl ! f G mnnilurin,-, Plum I otat. on or l K Well IU (Sample puFc Pure Time of Da% Time Pumped (,eei Initial ' LEE. Stabilized "o LFl_ " C,114 (wlume) O, (%olume) --_--_ 0.01umci ;- — - -- o (�olume) M)IE P- Y y 0-75-s 0750 0 60 b b, . ,U., 4 -d. bed go. y �--shitrl- bej go, : y i I r r rj nL-',rra nn.rrn a,rcrrrroncrr craru /arms to urclude adduronal LFG ruonnorur; darn for rr?ons I rr the (rc rlrn V -I io N LI N f f is Methane: >1.25% by Volume (inside structures) AND >i% b. Volume (at facilit\ boundan ) Hydrogen Sulfide: >1% by Volume (inside structures) AND >410 by xolume (at facilit} boundary ) Certification To the best of m� knois ledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aisare that there are significant penalties for malting an- false statement, representation, or certification including the possibility of a fine and imprisonment. SIG\.ATL'RE TITLE Revised-Ntarch6 2017