Loading...
HomeMy WebLinkAbout4501_Henderson_MSWLF_LFG_FID1260931_20181119LkE—NR USE ONLY ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #: NC DENR Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Golder Associates NC, Inc. on behalf of Henderson County Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: David Y. Reedy II Phone: 336-852-4903 E-mail: dreedy@golder.com NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) Henderson County Closed Landfill 191 Transfer Station Drive 45-01 .1600/.0500 November 19, 2018 Hendersonville, NC 28791 Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring ❑ Detection Monitoring ❑ Assessment Monitoring ❑X Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells �X Methane gas monitoring data Groundwater monitoring data from private water supply wells Corrective action data (specify) Leachate monitoring data ❑ Other(specify) Surface water monitoring data Notification attached? eX No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. David Y. Reedy II, PG Senior Hydrogeologist 336-852-4903 Title (Area Code) Telephone Number -1 Signature — Date Golder Associates NC, Inc., 5B Oak Branch Drive, Greensboro, NC 27407 Facility Representative Address C-2862 INC PE Firm License Number (if applicable effective May 1, 2009) Re, i—i aionno Affix NC Licensed(PrAgsional Geologist Seal November 29, 2018 Ms. Jaclynne Drummond, Hydrogeologist North Carolina Department of Environmental Quality Division of Waste Management - Solid Waste Section 2090 US Highway 70 Swannanoa, North Carolina 28778 828-296-4706 Project No. 0839650618.202 METHANE MONITORING RESULTS — FOURTH QUARTERLY EVENT OF 2018 CLOSED HENDERSON COUNTY LANDFILL, PERMIT NO. 45-01 HENDERSON COUNTY, NORTH CAROLINA Dear Jackie, Attached are the results from the November 19, 2018, fourth quarterly methane monitoring event conducted at the above -referenced facility. As shown on the attached Boundary Gas Probe Monitoring Log, methane was not detected above the lower explosive limit (LEL) in any compliance methane monitoring points during the event. Methane was detected above the LEL at assessment methane monitoring well TR-3. No methane was detected in the facility structures during this compliance monitoring event. If you have any questions or concerns, please contact us at 336-852-4903. Sincerely, Golder Associates NC, Inc. David "Dusty" Y. Reedy II, PG Rachel P. Kirkman, PG Senior Hydrogeologist Associate and Senior Consultant Golder Associates NC, Inc. 5B Oak Branch Drive, Greensboro, North Carolina, USA 27407 Engineering Lic. No. C-2862/Geology Lic. No. C-399 T: +1 336 852-4903 F: +1 336 852-4904 Golder Associates NC, Inc. is a licensed user of the Golder trademark, and an associated operating entity. Golder and the G logo are trademarks of Golder Associates Corporation. golder.com Ms. Jaclynne Drummond, Hydrogeologist Project No. 0839650618.202 North Carolina Department of Environmental Quality November 29, 2018 CC: Marcus Jones, PE, Director of Engineering, Henderson County, 1 Historic Courthouse Square, Suite 6, Hendersonville, NC 28792. 828-694-6560. majones@hendersoncountync.org Greg Wiggins, Operations Manager, Henderson County, 191 Transfer Station Drive, Hendersonville, North Carolina 28791. 828-694-7982. gwiggins@hendersoncountync.org Attachments: Boundary Gas Probe Monitoring Log — November 19, 2018 Cut-off Trench LFG Vent Monitoring Log — November 19, 2018 Methane Monitoring Location Map Calibration Record gAprojects\henderson county\0839650618\phase 202 - Ah qtr Ifg 2018\200 deliverables\252 final issued\0839650618.202-001-r-rev0- Ifg_rpt_nov_2018.docx GOLDER BOUNDARY PROBE MONITORING LOG Project Name: Henderson County Landfill Site Contact: Grea Wiaains Starting Temperature: 58° F Project Number: 0839650618.202 Technician(s): Erik Vasko End Temperature: 63° F Starting Barometric Pressure: 27.8 in Hg End Barometric Pressure: 27.8 in Hg Monitoring Equipment: GEM 2000 Plus Date: 11/19/18 Monitoring Location Time Time Pumped (sec) %Methane (CH4) Carbon Dioxide (CO2) %Oxygen (Oz) %Balance Gas Initial ° LEL /° Stabalized ° /° LEL Hydrogen Sulfide (H2S, ppm) Monitoring Point Status MP-1 13:43 60 0.0 7.4 12.2 80.4 0 0 0.0 MSW Compliance Well MP-3 15:49 60 0.0 7.0 13.4 79.6 0 0 0.0 MSW Compliance Well MP-4 15:06 60 0.0 6.2 11.8 82.0 0 0 0.0 MSW Compliance Well MP-7 14:53 60 0.0 10.9 5.7 83.4 0 0 0.0 MSW Compliance Well MP-8 14:47 60 0.0 3.6 16.5 79.9 0 0 0.0 MSW Compliance Well MP-9 14:38 60 0.0 4.4 15.8 79.8 0 0 0.0 MSW Compliance Well Activity Building 14:08 200 0.0 0.0 21.3 78.7 0 0 0.0 Structure Animal Shelter 12:49 200 0.0 0.0 20.8 79.2 0 0 0.0 Structure Break House 14:12 200 0.0 0.0 21.4 78.6 0 0 0.0 Structure Bus Garage 12:56 200 0.0 0.0 20.8 79.2 0 0 0.0 Structure Convenience Center 13:03 200 0.0 0.0 20.7 79.3 0 0 0.0 Structure Maintenance Shop 15:55 200 0.0 0.0 21.2 78.8 0 0 0.0 Structure Scalehouse 12:42 200 0.0 0.0 21.0 79.0 0 0 0.0 Structure Trace Barn 14:33 200 0.0 0.0 21.3 78.7 0 0 0.0 Structure MP-6 15:43 60 0.0 0.0 21.0 79.0 0 0 0.0 MSW Assessment Well TR-2 14:24 60 0.0 2.4 19.0 78.6 0 0 0.0 MSW Assessment Well TR-3 14:28 60 34.3 34.9 0.3 30.5 686 686 1.0 MSW Assessment Well LFG-101 13:34 60 0.0 0.6 19.9 79.5 0 0 0.0 C&D Compliance Well LFG-102 13:28 60 0.0 3.6 14.8 81.6 0 0 0.0 C&D Compliance Well LFG-103 13:20 60 0.0 11.0 9.1 79.9 0 0 0.0 C&D Compliance Well Completed by: Erik Vasko GOLDER CUT-OFF TRENCH LFG VENT MONITORING LOG Project Name: Henderson Site Contact: G Starting Temperature: 58' F Starting Barometric Pressure: 27.8 in Hg Monitoring Equipment: GEM 2000 Plus Landfill Date: 11 /19/18 Project Number: 0839650618.201 Technician(s): Erik Vasko End Temperature: 63' F End Barometric Pressure: 27.8 in Ha Monitoring Location Time Time Pumped (sec) o /o Methane (CHa) % Carbon Dioxide (CO2) o /o Oxygen (OZ) o /o Balance Gas Initial o LEL /o Stabalized o LEL /o Hydrogen Sulfide (H2S, PPM) Monitoring Point Location Cut -Off Trench Vent 1 15:15 60 2.5 5.5 1.5 90.5 50 50 0.0 Southern Vent Cut -Off Trench Vent 2 15:18 60 17.2 13.6 8.4 60.8 344 344 1.0 Northern Vent Completed by: Erik Vasko ,,,> GOLDER r TRACE BARN EW 2 EW�EW a Q 1 ❑ Ci1T-OFF TRENCH VENT 2 - PA \ [ Alf 6 28 ❑2 W. ❑ 5 � u� V I 7 1 CLOT CUT-OFF TRENCH VENT 1 E Ew- 7 t E - , gEMOLI LANDFILL, CLO VI ATEMP 1 L DOSED C6 f 4 ' AST Hi E f o i �3 Ew - , ❑ to 1 r I LOSE e EANON , E / o MP-3 -45 W- w' P j ❑EW-I9 , ti dd❑ 199t r 4 PRIVAT ROPE LEGEND EXISTING 10 FT, CONTOUR EXISTING 2 FT. CONTOUR — - - — PROPERTY LINE — — — LIMITS OF WASTE STREAM BUFFER •'^^^^'^+ 7REELINE EXISTING ROAD FENCE -----,------ LFG COLLECTION PIPING ......... LFG CUT-OFF TRENCH Mw•8 COMPLIANCE MONITORING WELL s mw-1 NON COMPLIANCE MONITORING WELLS . MP-6 COMPLIANCE METHANE MONITORING WELLS A MP8 ASSESSMENT METHANE MONITORING WELLS ❑ BRA SURFACE WATER MONITORING POINT Q EVV-29 LFG EXTRACTION WELL CONVERTED TO PASSIVE VENTING NOTES 1. TOPOGRAPHIC CONTOUR INTERVAL = 2 FEET 2. COORDINATE SYSTEM IS N.C. STATE PLANE GRID. 3. TOPOGRAPHIC DIVIDING LINE DIVIDES THE SASE MAP TOPOGRAPHIC CONTOURS FROM LANDSAT TOPOGRAPHIC CONTOURS. LANDSATTOPOGRAPHICCONTOLRSHAVCASCONTOUR INTERVAL. 4. RECORDS WERE UNABLE TO BE LDCATED FOR LFG EXTRACTION WELLS EW-XI THROUGH EW-Xi AND WERE GIVEN IDENTIFICATION NAMES UNTIL SUCH TIME THAT RECORDS ARE FOUND. 5. LOCATION OF CCMFLIANCE METHANE MONITORING WELL MP-4 ISAPPROXIMATE. REFERENCE I. BASE MAP PROVIOEO BY CAMP DRESSER & MCKEE FROM PREVIOUS wATER QUALITY MONITORING REPORTS. 2. WELLS MP-?, MPS, AND MP-R WERE SURVEYED BY REGIONAL LAND SURVEYING. INC. ON JUNE 1 T. 2C T5. L SITELOCATIONAP N TO S D 150 300 SCALE FEET PRCJECT HENDERSON COUNTY HENDERSON COUNTY CLOSED MSVV AND C&D LANDFILL ����CLIENT ���::::::PERMIT#45-01 �_ONSULTANTPG C-399 YYYY-MM•DD 2G16.09.12 717— _ METHANE MONITORING LOCATION MAP �v PREPARED MAK s G a L D E R DESIGN DYR REVIEW DYR PROJECT No. DRAVUk- GOLDER ASSOCIATES NC, INC. APPROVED RPK 08396506 1 INSTRUMENT CALIBRATION REPORT Pine Environmental Services LLC 8411 Garvey Drive, Suite 113 Raleigh, NC 27614 Toll -free: (866) 646-PINE (7463) Pine Environmental Services, Inc. Instrument ID 8665 Description Landtec GEM-2000 + Calibrated 11/9/201810:35:29AM Manufacturer CES Landtec State Certified Model Number GEM2000+ Status Pass Serial Number/ Lot GM08581 Temp °C 19.2 Number Location North Carolina Humidity % 46 Department Calibration_ Specifications Group # 1 Range Ace % 0.0000 Group Name Methane Reading Ace % 3.0000 Stated Accy Pet of Reading Plus/Minus 0.00 Nom In Val / In Val In Type Out Val Out Type Fnd As Lft As Dev% Pass/Fail 50.00 / 50.00 %Volume 50.00 %Volume 47.00 50.00 0.00% Pass Group # 2 Range Ace % 0.0000 Group Name Carbon Dioxide Reading Ace % 3.0000 Stated Accy Pet of Reading Plus/Minus 0.00 Nom In Val / In Val In Type Out Val Out Type Fnd As Lft As Dev% Pass/Fail 35.00 /-35.00 %Volume 35.00 %Volume 34.50 35.00 0.00% Pass Group # 3 Range Ace % 0.0000 Group Name Oxygen Reading Ace % 3.0000 Stated Accy Pet of Reading Plus/Minus 0.00 Nom In Val / In Val In Type Out Val Out Type Fnd As Lft As Dev% Pass/Fail 20.90 / 20.90 %Volume 20.90 %Volume 20.80 20.90 0.00% Pass Group # 4 Range Ace % 0.0000 Group Name Hydrogen Sulfide Reading Ace % 3.0000 Stated Accy Pct of Reading Plus/Minus 0.00 Nom In Val / In Val In Type Out Val Out Type Fnd As Lft As Dev% Pass/Fail 25.00 / 25.00 PPM 25.00 PPM 20.00 25.00 0.00% Pass Group # 5 Range Ace % 0.0000 Group Name Carbon Monoxide Reading Ace % 3.0000 Stated Accy Pet of Reading Plus/Minus 0.00 Nom In Val / In Val In Type Out Val Out Type Fnd As Lft As Dev% Pass/Fail 50.00 / 50.00 PPM 50.00 PPM 52.00 50.00 0.00% Pass Pine Environmental Services LLC Windsor Industrial Park, 92 North Main Street, Bldg 20, Windsor, NJ 08561, 800-301-9663 www.pine-envirorimental.com INSTRUMENT CALIBRATION REPORT Pine Environmental Services LLC Pine Environmental Services, Inc. Instrument ID 8665 Description Landtec GEM-2000 + Calibrated 11/9/201810:35:29AM Test Instruments Used During the Calibration Test Standard ID Description Manufacturer Model Number NC 4 GAS 20.9 FBH-412-6 EX 5/19 NC 50/35 MAP-3 99-5 1 /20 NC 4 GAS 20.9 Gasco 32211 FBH-412-6 EX 5/19 8411 Garvey Drive, Suite 113 Raleigh, NC 27614 Toll -free: (866) 646-PINE (7463) Serial Number / Lot Number FBH-412-6 NC 50 CH4/35 CO2 Gasco GP 12126 - 31803 MAP-399-5 Notes about this calibration Calibration Result Calibration Successful Who Calibrated Ryan Williamson As Of Cal Entry Date Next Cal Date / Last Cal Date/ Expiration Date Opened Date 5/19/2019 1/20/2020 All instruments are calibrated by Pine Environmental Services LLC according to the manufacturer's specifications, but it is the customer's responsibility to calibrate and maintain this unit in accordance with the manufacturer's specifications and/or the customer's own specific needs. Notify Pine Environmental Services LLC of any defect within 24 hours of receipt of equipment Please call 800-301-9663 for Technical Assistance Pine Enviromnental Services LLC Windsor Industrial Park, 92 North Main Street, Bldg 20, Windsor, NJ 08561, 800-301-9663 www.pine-envirorirnental.com